The paper presents a finite control set model predictive current control FCS-MPC for reluctance synchronous motor (RSM). A detailed mathematical description of the maximum range of current ripple amplitude is presented, taking into account the most accurate model of a synchronous reluctance motor containing four inductance components. The experimental studies carried out indicate the correct analytical mathematical model to determine the amplitude of current ripples, both for low and high switching frequencies of the SiC MOSFET’s.
PL
W artykule przedstawiono sterowanie predykcyjne prądami synchronicznego silnika reluktancyjnego. Przedstawiono szczegółowy opis matematyczny pozwalający na wyliczenie maksymalnego zakresu tętnień prądu, z uwzględnieniem najdokładniejszego modelu synchronicznego silnika reluktancyjnego zawierającego cztery składowe indukcyjności. Przeprowadzone badania eksperymentalne wskazują na poprawny analityczny model matematyczny w celu wyznaczenia amplitudy tętnień prądu, zarówno dla niskich jak i wysokich częstotliwości kluczowania tranzystorów przekształtnika.
EN
The present paper investigates the feasibility of utilizing the simplified prediction model for finite control set model predictive current control (FCS-MPCC) applied to reluctance synchronous motors (RSMs). The FCS-MPCC exhibits torque and current ripples, and a crucial consideration is the reduction of these ripples by increasing the switching frequency. The algorithm’s computational complexity is tied to the accuracy of the adopted model. Two approaches with varying levels of accuracy in predicting current dependencies concerning changes in the inductance of the RSM are investigated. The findings highlight the potential of employing simplified fixed inductance values for efficient control in drive systems, particularly those amenable to high switching frequencies.
EN
Many researchers have made great efforts to develop DC converter designs, to study how to increase voltage gain with low voltage stress and low ripple current. This paper proposed a DC-DC converter with a high conversion ratio, low voltage stress, and low ripple current based on the combination of two parallel boost converters. Using the interleaving approach, two converters, an inductor-coupled converter, and a conventional converter are connected on both sides of the input source to reduce the ripple of the source current, and the load is shared between them. Voltage gain and voltage stresses across power semiconductors were determined using steady-state analysis. In addition, Input current and output voltage ripple were analyzed. The inductors of this converter operate in continuous conduction mode (CCM). Higher voltage gain does not entail maximum duty cycle levels, which eliminates issues such as diode reverse recovery. The use of a passive clamp circuit reduces the voltage stress of the switch. This allows the use of low-voltage rated switches with low "on-case" impedance, which increases overall system efficiency. Theoretical analysis and mathematical relationships were performed. Finally, to validate the theoretical calculations, this converter was simulated in MATLAB / SIMULINK program. The results were good and largely identical to the theoretical calculations.
PL
Wielu badaczy włożyło wiele wysiłku w opracowanie konstrukcji konwerterów prądu stałego, aby zbadać, jak zwiększyć wzmocnienie napięcia przy niskim napięciu napięciowym i niskim prądzie tętnienia. W artykule zaproponowano konwerter DC-DC o wysokim współczynniku konwersji, niskim naprężeniu napięciowym i niskim prądzie tętnienia opartym na połączeniu dwóch równoległych konwerterów boost. Stosując podejście z przeplotem, dwa konwertery, konwerter sprzężony z cewką indukcyjną i konwerter konwencjonalny są połączone po obu stronach źródła wejściowego w celu zmniejszenia tętnienia prądu źródłowego, a obciążenie jest między nimi dzielone. Wzmocnienie napięciowe i naprężenia napięciowe w półprzewodnikach mocy określono za pomocą analizy stanu ustalonego. Ponadto przeanalizowano tętnienia prądu wejściowego i napięcia wyjściowego. Cewki indukcyjne tego przetwornika działają w trybie przewodzenia ciągłego (CCM). Wyższe wzmocnienie napięcia nie pociąga za sobą maksymalnych poziomów cyklu pracy, co eliminuje problemy, takie jak odzyskiwanie wsteczne diody. Zastosowanie pasywnego obwodu zaciskowego zmniejsza naprężenie napięciowe przełącznika. Pozwala to na stosowanie przełączników niskonapięciowych o niskiej impedancji „w obudowie”, co zwiększa ogólną wydajność systemu. Przeprowadzono analizę teoretyczną i zależności matematyczne. Ostatecznie, aby zweryfikować obliczenia teoretyczne, konwerter ten został zasymulowany w programie MATLAB / SIMULINK. Wyniki były dobre iw dużej mierze identyczne z obliczeniami teoretycznymi.
EN
Recently, the use of electrolyzers for hydrogen production through water electrolysis is of great interest in the industrial field to replace current hydrogen production pathways based on fossil fuels (e.g. oil, coal). The electrolyzers must be supplied with a very low DC voltage in order to produce hydrogen from the deionized water. For this reason, DC-DC step-down converters are generally used. However, these topologies present several drawbacks from output current ripple and voltage gain point of view. In order to meet these expectations, interleaved DC-DC step-down converters are considered as promising and interesting candidates to supply proton exchange membrane (PEM) electrolyzers. Indeed, these converters offer some advantages including output current ripple reduction and reliability in case of power switch failures. In addition, over the last decade, many improvements have been brought to these topologies with the aim to enhance their conversion gain. Hence, the main goal of this paper is to carry out a thorough state-of-the-art of different interleaved step-down DC-DC topologies featuring a high voltage gain, needed for PEM electrolyzer applications.
EN
The effect of space vector modulation algorithm on magnitude of current vector ripples was considered on the mathematical model of a three-level three-phase voltage inverter with symmetric active inductive load. Limitations on the use of such inverters as a power supply for precision drive of optical telescopes were specified.
EN
This paper describes a discrete adaptive state feedback controller used to load current control in terms of variable DC voltage of inverter. Controller was designed by using linear quadratic optimization method. Adaptive LQR was used because of non-stationarity of the control system caused by Voltage Matching Circuit - VMC. Gain values of the adaptive controller were approximated by using an artificial neural network. The VMC was realized as an additional buck converter integrated with the main inverter. As the load of the 2-level inverter a 3-phase symmetric RL circuit was used. Simulation tests show the behavior of the load current regulation during DC bus voltage level step changes. The dependence between current RMS value and inverter DC bus voltage level was also shown. Simulation test was made by using Matlab Simulink and PLECS software.
EN
This paper describes a discrete adaptive linear quadratic regulator used to load current control in terms of variable DC voltage of inverter. Controller was designed by using linear quadratic optimization method. Adaptive LQR was used because of non-stationarity of the control system caused by Voltage Matching Circuit - VMC. Gain values of the adaptive controller were approximated by using an artificial neural network. The VMC was realized as an additional buck converter integrated with the main inverter. As the load of the 2-level inverter a 3-phase symmetric RL circuit was used. Simulation tests show the behavior of the load current regulation during DC bus voltage level step changes. The dependence between current RMS value and inverter DC bus voltage level was also shown. There were also made a comparison of the traditional 2-level inverter structure with the modified structure uses VMC. Simulation test was made by using Matlab Simulink and PLECS software.
8
Content available remote Ripple estimation in active power filters
EN
The paper presents the analytical method of ripple estimation in active power filters. The method is based on an average model of PWM voltage source inverter. The formulae for the ripple magnitude are derived for single-phase and three-phase three-leg structures. Numerical examples for filters generating third and fifth order harmonics are presented. The example with reactive component of fundamental harmonic is considered as well.
PL
Przedstawiono analityczną metodę estymacji tętnienia prądu wynikającego z przełączeń obwodu w aktywnych filtrach energetycznych. Metoda opiera się na uśrednionych modelach z modulacją PWM. Odpowiednie formuły analityczne zostały opracowane dla układu jednofazowego i trójfazowego. Wykonano obliczenia dla układu generującego trzecią i piątą harmoniczną oraz układu generującego składową bierną harmonicznej podstawowej.
9
Content available remote Ripple Analysis for Three-Phase Four-Leg Active Power Filters
EN
The paper presents the analytical method of ripple estimation in active power filters. The method is based on an average model of PWM voltage source inverter. The formulae for the ripple magnitude are derived for three-phase four-leg structures. The numerical example for filters generating third order harmonics is presented.
PL
Przedstawiono analityczną metodę estymacji tętnienia prądu wynikającego z przełączeń obwodu w aktywnych filtrach energetycznych. Metoda opiera się na uśrednionych modelach z modulacją PWM. Odpowiednie formuły analityczne zostały opracowane dla układu trójfazowego czteroprzewodowego. Wykonano obliczenia dla układu generującego trzecią harmoniczną prądu.