Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  waste water treatment plant
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Morocco’s Atlantic coast, faces significant anthropogenic disturbances, leading to pollution in its waters used for various purposes. The primary objective of this study is to shed light on how the depollution project, a crucial part of the Bouregreg valley development plan, has influenced the coastal area of the city. This has been achieved through a comprehensive analysis of the water quality, focusing on both physico-chemical characteristics and bacteriological aspects. Thirteen specific physico-chemical parameters and fecal pollution indicators were meticulously monitored along the coastline. The goal was to gain insights into how water quality has changed over time and across different locations. The results of this investigation have revealed the substantial impact of the Wastewater Treatment Plant (WWTP) on the area, with varying degrees of efficiency observed, such as 63.04% for turbidity, 52.21% for BOD5, and 40% for organic matter.
EN
Pharmaceuticals and personal care products (PPCPs) discharged into environment has several adverse impacts. PPCPs are widely utilised for veterinary as well as cosmetic and personal health reasons. These are members of the expanding class of substances known as Contaminants of Emerging Concern (CECs). Antibiotic resistance in the environment and garbage generated by PPCP endanger life. The World Health Organisation (WHO) now recognises antibiotic resistance as a significant global health problem due to the expected increase in mortality caused by it. In the past ten years, mounting data has led experts to believe that the environment has a significant impact on the development of resistance. For human diseases, the external environment serves as a source of resistance genes. It also serves as a major pathway for the spread of resistant bacteria among various habitats and human populations. Large-scale DNA sequencing methods are employed in this thesis to better comprehend the dangers posed by environmental antibiotic resistance. The quantification of the number is an important step in this process. Metagenomic measurement of the number of antibiotic resistance genes in various contexts is a crucial step in this process. However, it’s also crucial to put this data into a broader context by integrating things like taxonomic information, antibiotic concentrations, and the genomic locations of found resistance genes.
PL
W artykule przedstawiono rozwiązanie zastosowane w Hamburgu przy rozbudowie oczyszczalni ścieków. Z uwagi na brak miejsca drugą część oczyszczalni ścieków zbudowano po przeciwnej stronie rzeki Elby. Przesył ścieków zrealizowany jest tam poprzez syfon o konstrukcji żelbetowej. Projektanci chcąc zapewnić bezpieczeństwo zaproponowali usytuowanie syfonu w gruntach nieprzepuszczalnych, co wiązało się z jego zagłębieniem na około 80 m poniżej poziomu terenu. W przeciwieństwie do rozwiązania zastosowanego w oczyszczalni Czajka w Warszawie, gdzie w tunelu zainstalowano dwie rury GRP do przesyłu ścieków, w Hamburgu ścieki płyną całym przekrojem żelbetowego tunelu syfonowego. O jakości projektu zrealizowanego w roku 1986 w Hamburgu świadczy jego bezawaryjna praca od 34 lat.
EN
In the paper the solution applied in Hamburg in the process of extending waste water treatment plant was presented. Due to limited space available the second part of the waste water treatment plant was built on the other side of the River Elbe. The waste water is transferred there by the siphon tunnel made of reinforced concrete. In order to ensure the safety of the construction the designers suggested the installation of the siphon tunnel in impermeable soils, which required its installation around 80 meters below ground surface. In contrast to the solution applied in Czajka where two GRP pipes are placed in the tunnel, in Hamburg waste water is transferred by the whole reinforced concrete siphon tunnel cross section. The good quality of the siphon tunnel project carried out in 1986 is confirmed by its trouble free operation for 34 years.
EN
The characteristics of Polish rural agglomerations indicate that only 32% of these areas are villages typified by compact buildings where the use of a collective sewage system is economically justified. In other areas, it is necessary to apply solutions that allow for the sewage utilization in place of their creation and safe discharge into the environment, e.g. in the form of home systems based on biological processes, e.g. in soil-plant systems. The purpose of the work was to determine the soil-plant efficiency of wastewater treatment with the use of so-called energy plants. The experiment was conducted in 2012–2014 in lysimeters at a depth of 130 cm and 100 cm in diameter. These were submerged in the ground, filled with sand clay and equipped with installations enabling the drainage of gravity water in the form of lysimeter effluents. Two species of plants were used: Miscanthu giganteus and Sida hermaphrodita (L.) Rusby. They were irrigated with pretreated domestic sewage (variant I – 1200 mm year−1 and variant II – 1600 mm year−1). For irrigation, sewage from a group of buildings inhabited by six families was used. Raw domestic sewage was discharged into the tank, consisting of four chambers, which constituted a relatively good level of pre-cleaning. For the irrigation of plants in the experiment, pre-treated sewage was used. In order to determine the effectiveness of wastewater treatment in the soil-plant environment, the concentrations of the following components were determined in the effluents: TSS, BOD5, COD, Ntot. The quantities of pollutants contained in the sewage were characterized by considerable variability, especially in relation to COD (390.6– 1583.0 mg O2 dm−3) and Ntot (47.0–250.2 mg N dm−3).
PL
W artykule zaprezentowano podstawowe informacje dotyczące siłowni typu ORC, technologii, której celem jest konwersja ciepła odpadowego na prąd elektryczny. Główną zaletą tego typu układów jest możliwość stosowania technologii w małej skali, do tak zwanej generacji rozproszonej, w dość szerokim zakresie temperatur i mocy źródła ciepła napędowego. W pierwszej części pracy przedstawiono wyniki obliczeń teoretycznych efektywności pracy podkrytycznej niskotemperaturowej siłowni ORC zasilanej ciepłem odpadowym powstałym w procesie chłodzenia silnika wysokoprężnego służącego do wytwarzania energii elektrycznej. Źródłem energii napędowej (paliwem) dla tego silnika jest biogaz wytwarzany w oczyszczalni ścieków. W dalszej części artykułu przedstawiono podstawowe informacje o praktycznym znaczeniu: przykładowe parametry układów ORC dostępnych w ofercie komercyjnej, takie jak: zakres mocy, parametry źródła ciepła napędowego, przykładowe ceny jednostkowe układów ORC.
EN
In the article are presented the most essential information about ORC power plants. The purpose of using this technology is conversion of waste thermal heat (of renewable) to electricity. The main advantage of this type of systems is the ability to use in small scale – so called distributed generation, in quite a wide range of temperatures and power of waste heat sources. In the first part of the work are present the results of a theoretical analysis of the efficiency of low-temperature subcritical ORC power plant powered with waste heat emitted from IC gas engine. Source of propulsion energy (fuel) for this engine is biogas produced in the waste water treatment plant. Later in this article are shown the information with practical sense: sample parameters of ORC systems available in commercial offerings such as the range of power parameters of the heat source, power output of ORC and the sample unit prices of ORC systems.
EN
The paper presents the analysis and evaluation of six sewage treatment plants. The effectiveness of wastewater treatment was assessed for the following treatment facilities: Barcza (O1), Opatow (O2), Ostrowiec (O3), Starachowice (O4), Sandomierz (O5) and Piaseczno (O6). The evaluation of plant operation was based on the amount of reduction of five selected pollution indicators: BOD5, COD, total suspension, total nitrogen and total phosphorus. In addition, COD/BOD5 ratios were determined, the reliability coefficient (RC) was calculated and the degree of use of sewage treatment plant capacity, in relation to pollutant loads, was assessed. The paper also analyzes the non uniformity coefficient that characterizes variation in sewage flow.
PL
W pracy przedstawiono analizę oraz ocenę funkcjonowania sześciu oczyszczalni ścieków. Ocenie efektywności systemu oczyszczania poddano oczyszczalnie ścieków Barcza (O1), a także w Opatowie (O2), Ostrowcu Świętokrzyskim (O3), Starachowicach (O4), oraz w Sandomierzu (O5) i Piasecznie (O6). Oceny poprawności działania oczyszczalni oparto na wielkości redukcji 5 wybranych wskaźników zanieczyszczeń: BZT5, ChZT, zawiesina ogólna, azot ogólny i fosfor ogólny. Poza tym dokonano obliczeń stosunku ChZT/BZT5, jak i również obliczono współczynnik niezawodności WN oraz stopień wykorzystania przepustowości oczyszczalni ścieków ze względu na ładunki zanieczyszczeń. W pracy przeanalizowano również wartość współczynnika nierównomierności, który charakteryzuje zmienność dopływu ścieków.
PL
Przedstawiono przykład żelbetowego zbiornika oczyszczalni ścieków, w którym wystąpiły rysy na powierzchni ściany zewnętrznej, spowodowane zbyt długą przerwą między betonowaniem fundamentu i ściany zbiornika.
EN
Cracking of external cylindrical wall of RC container as a consequence of too long break time between concreting of the foundation and the wall is presented.
PL
Podano podstawowe informacje dotyczące zrealizowanych, budowanych bądź modernizowanych oczyszczalni ścieków, stacji uzdatniania wody i zakładów unieszkodliwiania odpadów komunalnych.
EN
Basic information is presented about waste water treatment plants, water treatment stations and solid waste treatment plants which either have been completed, are now under construction or being modernized.
9
Content available remote Occurrence of acidic pharmaceuticals in the Warta River in Poland
EN
The occurrence of five acidic pharmaceuticals (ibuprofen, naproxen, ketoprofen, diclofenac, bezafibrate and clofibric acid) in the Warta River in Poland has been discussed. A significant effect of the effluents of Wastewater Treatment Plants (WWTPs) on the quality of recipient water has been shown. Diclofenac, ibuprofen, naproxen, and ketoprofen were found in all samples collected along the Warta River at average concentrations of several ng L-1'. Average concentration of the above pharmaceuticals in raw sewage entering wastewater plants was at the level of a few μg L-1. The efficiency of pharmaceuticals' removalfrom the raw sewage was very high and reached 97-100%. Diclofenac was the only compound, which exhibited a significant resistance towards the treatment (< 65%), and accordingly its concentration in the recipient water was the highest. Solid phase extraction (SPE) was use for separation of pharmaceuticals from the water phase and HPLC-ESI-MS/MS system was applied for the analysis.
PL
W pracy przedstawiono wyniki badań nad obecnością w rzece Warcie pięciu farmaceutyków o charakterze kwasowym: ibuprofenu, naproksenu, diklofenaku, bezafibratu i kwasu klofi-browego. Związki te dostają się do środowiska najczęściej wraaze ściekami komunalnymi, ponieważ część z nich odporna na procesy biodegradacji nie ulega całkowitej eliminacji w trakcie procesów oczyszczania. Diklofenak, ibuprofen, naproksen i ketoprofen wykryto we wszystkich próbkach wody średnio na poziomie ng L-1. Średnie stężenie powyższych farmaceutyków w nieoczyszczonej wodzie przed oczyszczalniami było na poziomie kilku μL-1. Skuteczność usuwani a badanych farmaceutyków w oczyszczalni ścieków wynosiła około 97-100%, jedynie w przypadku diklofenaku była niższa niż 65%. W pracy zastosowano technikę SPE do ekstrakcji i zatężania próbek oraz układ analityczny HPLC-ESI- MS/MS.
EN
Wastewater treatment has become a very important aspect of environmental protection. The main goal of a wastewater treatment plant (WWTP) is to reduce the level of waste-water pollution. The application of AT (artificial intelligence) techniques in wastewater treatment provides an alternative way of operating complex process, helps to reduce energy consumption and to improve the efficiency of the equipment. Modern control systems developed in the recent years are often based on complex mathematical models of the processes, which allow one to develop an optimized treatment strategy. However, they require the knowledge of several parameters that are not commonly measured in a WWTP or they are not measured with often enough for control purposes. One of them is COD (chemical oxygen demand). The procedure of its measurement is long and thus problematic. !n this work we have proposed a new approach to the COD control system and its further improvement applying FNN (fuzzy neural network). The main goal was to shorten and simplify determination of COD based on the on-line parameter. The developed approach is expected to be successfully applicable in the real time system control.
PL
Oczyszczanie ścieków jest jednym z ważniejszych aspektów ochrony środowiska. Nowoczesne systemy kontroli w oczyszczalniach ścieków pozwalają na poprawę jakości procesu oczyszczania redukując jednocześnie koszty. Systemy kontroli i optymalizacji, jakie od kilku lat opracowuje się dla oczyszczalni ścieków, bazujązazwyczaj na skomplikowanych modelach matematycznych. Kluczowym problemem w zastosowaniu tych systemów jest duża liczba parametrów, które nie są zazwyczaj mierzone lub częstotliwość pomiarówjest nicwystarczającaz punktu widzenia systemów kontroli. ChZT (chemiczne zapotrzebowanie na tlen) jest jednym z takich parametrów. Odgrywa on kluczową rolę w modelowaniu procesów osadu czynnego, jednakże, ze względu na długi czas analizy, jego zastosowanie w układzie kontroli jest utrudnione. W tej pracy określono sposoby s/ybkiego wyznaczania przybliżonej wartości ChZT na podstawie innych parametrów z zastosowaniem rozmytych sieci neuronowych.
PL
Rząd RP udzielił rządowi ChRL kredyt w wysokości 85 min USD. Przedstawiono propozycję jego wykorzystania w projekcie polsko-chińskim dotyczącym ztewniowej gospodarki wodno-ściekowej.
EN
The Polish government has given a credit of 85 mln US do!, to the government of ChPR. There have been presented proposal that that credit should be utilized in the framework of the Polish-Chinese project concerning water and waste water management in river basins.
PL
Artykuł przedstawia plan finansowy dotyczący budowy kanalizacji i oczyszczalni ścieków w gminie Jedlińsk k. Radomia oraz analizę rentowności tej inwestycji z punktu widzenia gminy jako jednego z inwestorów i późniejszego użytkownika i beneficjenta urządzeń.
EN
The paper presents the financial plan concerning building of the sewage system and waste water treatment plant in the commune Jedlińsk in the neighbourhood of Radom and the analysis of profitability of the projekct from the point of view of the commune as one of the investors and later on the user and incumbent of the plant.
PL
Przedstawiono ocenę ekonomicznej efektywności budowy oczyszczalni ścieków i kanalizacji opartą na procedurze stosowanej w krajach Unii Europejskiej i zaleconą przez Brytyjski Fundusz KNOW-HOW.
EN
The paper presents evaluation of the economic effectiveness of building a waste water treatment plant and sewerage system based on procedure being used in the European Union and recommended by the British Fund KNOW-HOW.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.