EN
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and the possibility of reuse of washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of washings drainage into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of washings from the analysed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. Washings were subjected to sedimentation and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
EN
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and possibility of reusing the washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of drainage of washings into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of the washings from the analyzed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. The washings were sedimented and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
PL
Przedstawiono wpływ rodzaju złóż filtracyjnych, stanowiących wypełnienie filtrów w układach oczyszczania wody basenowej, na jakość i możliwość zagospodarowania popłuczyn. Badaniami objęto 4 obiegi basenowe, w których zastosowano złoża: piaskowe, piaskowo-antracytowe, szklane oraz okrzemkowe. Stopień zanieczyszczenia popłuczyn oceniono na podstawie badań fizyczno-chemicznych i bakteriologicznych próbek popłuczyn. Rozważono możliwość odprowadzania popłuczyn do środowiska naturalnego, a wyniki badań porównano z dopuszczalnymi wartościami wskaźników zanieczyszczeń dla ścieków odprowadzanych do wód lub ziemi. Bezpośrednie zagospodarowanie popłuczyn z analizowanych filtrów okazało się niemożliwe przede wszystkim ze względu na duże zawartości zawiesin ogólnych oraz chloru wolnego. Z tego względu popłuczyny poddano sedymentacji, a wodę nadosadową intensywnemu mieszaniu. W wyniku tych procesów jakość popłuczyn uległa znacznej poprawie. Pozwoliło to planować uzupełnianie instalacji wody basenowej o układy zagospodarowania popłuczyn.
PL
Oceniono możliwości zastosowania procesu koagulacji objętościowej do oczyszczenia popłuczyn z instalacji uzdatniania wody w pływalni krytej. Efektywność wybranych koagulantów glinowych wstępnie zhydrolizowanych (zakres dawek: 0,5÷3,0 mgAI/dm3) oceniono w oparciu m.in. o zawartość zawiesin ogólnych oraz stężenia ogólnego węgla organicznego (OWO) w próbkach przed i po procesie koagulacji. Badane koagulanty wykazywały bardzo wysoką skuteczność w usuwaniu mętności (od 93% do 97%). Większość z badanych próbek popłuczyn po koagulacji charakteryzowała się zawartością zawiesin ogólnych, która pozwala na odprowadzenie ich do środowiska, (tj. poniżej 35 mg/dm3). Dodatkowo, zastosowanie koagulantu PAX 16 pozwoliło na obniżenie stężenia OWO w popłuczynach o ponad 60%. Za optymalną uznano dawkę PAX 16-0,5 mgAI/dm3. Pozostałe koagulanty wykazywały zróżnicowaną efektywność oczyszczania popłuczyn, która zależała od ich dawki. Zastosowanie procesu koagulacji popłuczyn w obiegach uzdatniania wody basenowej, daje możliwość ograniczenia ilości odprowadzanych ścieków do systemów kanalizacyjnych i ich bezpieczne odprowadzanie do środowiska. Niezbędna jest jednak indywidualna analiza jakości fizykochemicznej i objętości popłuczyn.
EN
The paper presents the possibilities of using a volumetric coagulation process to purification the backwashing water from a water treatment plant in an indoor swimming pool. The effectiveness of selected pre-hydrolyzed aluminium coagulants (in the dose of 0.5÷3.0 mgAI /dm3) was evaluated based on the amount of total suspended solids and the concentration of total organie carbon (TOC) in samples before and after the coagulation process. The coagulants tested showed high efficiency in removing turbidity (from 93 to 97%). Most of the tested samples of post-coagulum washings were characterized by the content of the total suspension, which would allow them to be discharged into the environment (less than 35 mg/dm3). In addition, the PAX 16 coagulant contributed to lowering the TOC concentration by more than 60% (throughout the range of doses used). The dose of PAX 16-0.5 mgAI/dm3) was considered as an optimal. Other coagulants showed varying effectiveness, highly dose dependent. The coagulation process may allow to limit the discharge of wastewater from the swimming pool facility and to discharge the washings into the environment in safety way. However, an individual analysis of physicochemical quality and volume of washings is indispensable.
PL
Eksploatacja obiektów basenowych związana jest z wysokimi kosztami. Racjonalna gospodarka wodno-ściekowa, uwzględniająca zagospodarowanie wody z popłuczyn, jest sposobem na obniżenie kosztów odprowadzania ścieków do kanalizacji. W pracy przedstawiono możliwości odprowadzenia popłuczyn z 5 różnych obiegów basenowych, do środowiska naturalnego. Na podstawie analiz fizyczno-chemicznych próbek popłuczyn określono ich jakość. Wyniki badań porównano z dopuszczalnym stopniem zanieczyszczeń w ściekach odprowadzanych do wód lub ziemi (DzU 2014, poz. 1800). Badania wykazały, że popłuczyny nie mogą być bezpośrednio odprowadzane do wód lub ziemi głównie ze względu na dużą zawartość zawiesin, chloru i wysokie wartości ChZT. Zastosowany, w warunkach laboratoryjnych, proces sedymentacji pozwolił na obniżenie ilości zawiesin i wskaźnika ChZT poniżej wartości dopuszczalnych. 2 godzinny czas sedymentacji wpłynął na zmniejszenie stężenia chloru. Przedstawiono również możliwości zagospodarowania wody nadosadowej oraz oszczędności wynikające z jej zagospodarowania.
EN
Exploitation of swimming pool facilities relates to high costs. Rational water and sewage management, considering the management of water from sewage, is a way to reduce the costs of sewage disposal to the sewerage system. The paper presents the possibilities of draining washings from 5 different swimming pools to the natural environment. Based on physical and chemical analyses of washings samples, their quality was determined. The results of the tests were compared with the permissible degree of pollution in wastewater discharged into water or soil (Journal of Laws 2014, item 1800). Studies have shown that washings cannot be directly discharged into water or soil mainly due to high content of suspended solids, chlorine content and high COD values. The sedimentation process, applied under laboratory conditions, has allowed the amount of suspensions and COD to be reduced below the limit values. 2-hour sedimentation time reduced chlorine concentration. The possibilities of management of the supernatant water and savings resulting from its management were also presented.
EN
The main purpose of the research is to show the possibility of using washings after applying simple processes and devices. It is being considered whether they may be drained to watercourses, to the ground, used for watering plants, sprinkling tennis courts and playing fields, flushing toilets or recycled into pool systems. The research concept consisted of comparing the results of physico-chemical analysis of washings samples with the limit values for pollutants in wastewater discharged to water and ground. The research was carried out for 20 pool water treatment plants. It has been shown that the concentration of TSS (total suspended solids) and free chlorine in washings are the main parameters preventing their drainage to the natural environment. The processes of sedimentation or sedimentation assisted by coagulation allow to reduce the TSS concentration below the limit value and leaving the washings to stand for up to several hours or subjecting them to a few minutes of aeration decreases the concentration of free chlorine to an acceptable level. The obtained research results allow to assume that the management of washings in all tested swimming pools would be possible after applying a settler or a settling tank with a coagulant chamber and then a chamber for aeration.
EN
The paper presents usefulness of membrane processes (ultrafiltration (UF) and nanofiltration (NF)) for treatment of backwashing water of pool water system. The backwashings were taken from circulations located in two indoor facilities from pools of various functionalities. Moreover, the used samples had different quality in terms of physical and chemical parameters. The test used various membranes, both in respect of the polymer that they were made of and their separation capacity. Transport and separation properties of ultrafiltration (MW and V5) and nanofiltration (DK and HL) membranes were specified. Furthermore, backwashing water samples before and after membrane process treatment were subjected to Microtox® toxicity test. The conducted processes helped to reduce turbidity and specific absorbance at UV254nm 1m , both during ultrafiltration as well as nanofiltration.Much higher hydraulic performance was observed in ultrafiltration membranes. After each filtration cycle a Microtox® toxicity test was carried out which revealed reduced washings toxicity in relation to bacteria in all tested samples.
PL
W pracy określono przydatność procesów membranowych (ultrafiltracji UF i nanofiltracji NF) do oczyszczania popłuczyn filtracyjnych z instalacji wody basenowej. Popłuczyny zostały pobrane z obiegów zlokalizowanych w dwóch obiektach krytych, o różnym przeznaczeniu niecek. Próbki charakteryzowały się zróżnicowaną jakością, opisaną parametrami fizykochemicznymi. Badania prowadzono z wykorzystaniem różnych membrany, zarówno pod względem tworzącego ich polimeru, jak i zdolności separacyjnych. Wyznaczono właściwości transportowo-separacyjne membran UF (MWi V5) i NF (DK i HL). Dodatkowo próbki popłuczyn, przed i po procesie membranowym poddano przesiewowemu testowi toksycznościMicrotox®. Odnotowano obniżenie ilości substancji wpływających na mętność wody oraz związków organicznych wyrażonych wskaźnikiem absorbancji w UV254nm 1m , zarówno w procesach ultrafiltracji, jak i nanofiltracji. Znacznie wyższą wydajnością hydrauliczną odznaczały się membrany ultrafilracyjne. We wszystkich przeprowadzonych cyklach filtracyjnych stwierdzono obniżenie toksycznych właściwości popłuczyn w stosunku do bakterii Aliivibrio fischeri w teście Mirotox®.
PL
W pracy przedstawiono wyniki badań, na podstawie których określono możliwość odprowadzenia popłuczyn, powstałych w wyniku płukania złóż filtracyjnych w systemie oczyszczania wody basenowej, do pobliskiej rzeki. Na podstawie analiz fizyczno-chemicznych próbek popłuczyn określono stopień ich zanieczyszczenia. Wyniki badań porównano z zaleceniami dotyczącymi dopuszczalnego stopnia zanieczyszczeń w ściekach odprowadzanych do wód lub ziemi (DzU 2014, poz. 1800) i wymaganiami pozwolenia wodnoprawnego wydanymi dla analizowanego obiektu basenowego. Analiza wyników badań popłuczyn surowych (niepoddanych obróbce) wykazała, że bezpośrednie ich odprowadzenie do rzeki jest niemożliwe przede wszystkim ze względu na duże stężenie chloru wolnego oraz ilość zawiesin ogólnych. Analiza wyników badań popłuczyn poddanych procesowi sedymentacji lub koagulacji objętościowej w warunkach laboratoryjnych pozwoliła zaprojektować system odprowadzenia wody nadosadowej do rzeki. Warunkiem „zrzutu” wody nadosadowej do rzeki będzie konieczność zastosowania zbiornika buforowego, osadnika lub systemu wspomagającego sedymentację zawiesin w popłuczynach np. poprzez zastosowanie koagulacji objętościowej, a następnie odprowadzanie zagęszczonych ścieków do kanalizacji sanitarnej.
EN
The paper presents the results of studies on determining of the possibility of discharge washings, as a result of rinse filter beds in the swimming pool water treatment system, to the river. Based on the physical and chemical analysis of washings samples the degree of their contamination was determined. The results were compared with the recommended acceptable level of pollutants in wastewater discharged to water or soil (OJ 2014, item 1800) and with the requirements of the water permit issued for the analyzed swimming pool. The obtained results for raw washings (untreated) showed that direct discharge of washings into the near located river is impossible, especially due to the high concentration of free chlorine and the amount of total suspended solids (TSS). Analysis of the results of washings subjected to the process of sedimentation or coagulation in the laboratory helped design the system supernatant water drain into the river. The condition of such management would be to use a buffer tank, settling tank or supporting system to sedimentation of suspended solids, e.g. the use of coagulation and then the draining of concentrated sewage into the sanitary sewage system.
EN
The article presents the possibilities of employing an integrated flocculation/ultrafiltration system in the treatment of washings generated upon the rinsing of filter beds in pool water installations. Single ultrafiltration process was used as a comparator. Flocculation was carried out using commercial dialuminium pentahydroxychloride solution widely used at pool facilities for the removal of contaminants in flocculation processes. The studies consisted in determination of correlations between the conditions of the flocculation process (variable doses of Al3+ ions: from 4 to 280 mg/L) and the transport/separation characteristics of ultrafiltration membranes. Flocculation was performed at different temperatures of washings i.e. 8, 21, and 30°C for each of the pre-defined doses. Ultrafiltration was highly capable of reducing the turbidity of washings and removing a large group of contaminants as determined by turbidimetry and UV254 absorbance measurements. The studies revealed that the best transport/ separation characteristics of ultrafiltration membranes were obtained in a system in which ultrafiltration was performed following flocculation of washings carried out at 21°C using a 40 mgAl3+/L solution. The turbidity was reduced by ca. 99% and UV absorption was reduced by ca. 94% while the relative volumetric stream of the permeate increased by more than 35% (as compared to the filtration of washings in a single-process system). Membrane ultrafiltration significantly increased the quality of the waste stream consisting of washings from the pool water installation. Pre-processing of washings is required before ultrafiltration in order to limit the blocking of membrane pores. Flocculation may be one of such pre-processing methods.
EN
Swimming pools are very expensive, in terms of operation, sports facilities. Therefore, investors and managers of these facilities are looking for methods of reducing the costs of their use. One of the proposed methods is the managing of washings previously discharged to the sanitary sewage system. The assessment of possibilities for reuse of washings from swimming pool filtration system is based on the limits of basic indicators of pollutants in wastewater discharged to water and soil (temperature, pH, TSS, BOD5, COD, TN, TP, free chlorine). The conducted research of washings quality from 26 tested swimming pools have shown that washings quality is dependent on the operating conditions of the pool circuit, including the filter cycle duration and types of filter bed. A direct discharge to water or soil may be impossible due to excessive amounts of total suspended solids (above 35 mg/dm3) and free chlorine concentration (above 0.2 mg Cl2/dm3). However, the quality of supernatant water of washings subjected to sedimentation in the laboratory shows that the washings are suitable for reuse. The installation of settling tanks in swimming pool facilities could relieve the sewage systems and allow for the discharge of supernatant water to surface waters or for the irrigation of green areas in an environmentally friendly way.
PL
W pracy przedstawiono możliwość wykorzystania membranowego procesu ultrafiltracji do oczyszczania popłuczyn z instalacji basenowych. Badania obejmowały proces jednostkowy ultrafiltracji oraz zintegrowany układ napowietrzanie-ultrafiltracja, który pozwolił na częściowe usunięcie zanieczyszczeń występujących w nadawie. Porównano membrany o zróżnicowanym materiale polimerowym oraz różnej wartości granicznej masy molowej cut-off. Określono wpływ zastosowanego procesu wstępnego na zdolności transportowo-separacyjne membran o różnych własnościach fizyczno-chemicznych. Uzyskano wysoką wydajność hydrauliczną we wszystkich prowadzonych filtracjach (w zakresie od 1,23·10-5 do 1,40·10-7 m³/m²·s). W zakresie usuwania mętności badane układy charakteryzowały się współczynnikiem usunięcia przekraczającym 90%. Odnotowano znaczące usunięcie grupy zanieczyszczeń opisanych przez wskaźnik ogólny, tj. absorbancję w nadfiolecie UV254. Przeprowadzone badania wykazały możliwość wykorzystania ultrafiltracji do odzysku wody basenowej z popłuczyn poprocesowych.
EN
The paper presents the possibility of using the membrane ultrafiltration process for the treatment of washings from pool water systems. The tests included a unit ultrafiltration process and airing-ultrafiltration integrated system which partly removed contamination from the feed material. Membranes of various polymere materials and molar mass cut-off were compared. This helped to determine the influence of the used initial process on transport and separation abilities of the membranes of different physical and chemical features. High hydraulic performance was obtained in all performed filtration actions (1.23·10-5 ÷ 1.40·10-7 m³/m²·s). In respect of fighting turbidity, all tested systems had a removal rate of more than 90%. It was also noted that a significant amount of contamination described by the general indicator, which is specific UV254 absorbance, was removed. The tests proved that ultrafiltration can be used for recovery pool water from post-process washings.
PL
Baseny to bardzo drogie pod względem eksploatacji obiekty sportowe, dlatego też osoby zarządzające tymi obiektami szukają sposobów na obniżenie kosztów ich użytkowania. Jednym z nich jest zagospodarowanie popłuczyn dotychczas odprowadzanych do kanalizacji sanitarnej. Oceny możliwości zagospodarowania popłuczyn odprowadzanych z filtracyjnych instalacji basenowych dokonano na podstawie dopuszczalnych wartości podstawowych wskaźników zanieczyszczeń w ściekach odprowadzanych do wód i ziemi (pH temperatura, zawiesiny ogólne, ChZT, BZT5, Pog, Nog, chlor wolny). Badania jakości popłuczyn z 26 basenów wykazały, że ich jakość jest zależna od warunków eksploatacji danego obiegu basenowego, m.in. długości cyklu filtracyjnego i rodzaju złoża. Parametrami uniemożliwiającymi bezpośrednie zagospodarowanie popłuczyn były zbyt duża zawartość zawiesin ogólnych (≥ 35 mg/dm3) oraz stężenie chloru wolnego (≥ 0,2 mg Cl2/dm3). Jakość wód nadosadowych powstałych w wyniku sedymentacji popłuczyn wskazuje na ich przydatność do zagospodarowania. Zastosowanie w obiektach basenowych odstojników popłuczyn umożliwiłoby odciążenie systemów kanalizacji i odpływ wód nadosadowych do wód powierzchniowych lub ich wykorzystanie do nawadniania terenów zielonych w sposób bezpieczny dla środowiska.
EN
Swimming pools are very expensive in terms of exploitation sports facilities, therefore managers of these facilities are looking for methods of reducing the costs of their use. One of the proposed method is the managing of washings previously discharged to the sanitary sewage system. The assessment of possibilities of washings reusing from swimming pool filtration system is based on the limits of basic indicators of pollutants in wastewater discharged to water and soil (temperature, pH, TSS, BOD5, COD, TN, TP, free chlorine). The conducted research of washings quality from 26 tested swimming pools have shown that washings quality is dependent on the operating conditions of the circuit pool, including the filter cycle duration and types of filter bed. The parameters which prevents direct management washings were too high content of total suspended solids (≥ 35 mg/dm3) and the concentration of free chlorine (≥ 0.2 mg Cl2/dm3). Quality washings subjected to sedimentation indicates its usefulness for rational management. The application in swimming pools settling tanks allows discharge sewage systems and drainage supernatants to surface waters or using to irrigation green areas in an environmentally safe way.
PL
Wieloletnie badania doświadczalne prowadzone podczas płukania sieci wodociągowej metodą ukierunkowanego przepływu przyczyniły się do weryfikacji zależności między jakością popłuczyn a zasobami osadów w rurociągach, parametrami płukania, krotnością wymiany wody i zasięgiem oddziaływania wymuszenia przepływu wody w sieci. Stwierdzono, że wypłukiwanie osadów z rurociągów kształtuje się najpierw według krzywej gwałtownie rosnącej (pierwsza lub druga wymiana wody), a następnie opadającej, ponieważ po osiągnięciu maksimum zawartości zanieczyszczeń w popłuczynach obserwuje się wyraźnie malejącą tendencję do ich wypłukiwania wraz z upływem czasu płukania. Ilościową ocenę skuteczności wypłukiwania osadów z sieci wodociągowej wykonano na podstawie ich zawartości w próbkach popłuczyn. Wykazano, że maksimum zawartości zanieczyszczeń w popłuczynach warunkuje rodzaj, skład i wiek osadów oraz prędkość płukania i długość drogi przepływu popłuczyn.
EN
Many years' experiments performed during flushing of the water-pipe network by the method of unidirectional water flow have contributed substantially to the verification of the interactions among the quality of the washings, accumulation of deposits in the pipes, the parameters of flushing, the number of water exchange cycles, and the range of influence of forced water flow. It has been found that, at the beginning, the flushing of the deposits out of the water-pipe network proceeds according to the rapidly rising curve (the first or the second water exchange cycle) and then according to the falling curve. This is so because at the point in time when the pollutant content of the washings reaches the maximal value, an evidently downward trend sets on in the flushing of the pollutants out of the water-pipe network. The efficiency of flushing was quantified based on the pollutant content of the washings. It has been demonstrated that the maximal pollutant content of the washings is influenced by the type, composition and age of the deposits, as well as by the velocity of flushing and the length of washings flow.
EN
The article includes technological calculations of the parameters of volume and weight balance of washings from iron and manganese removers. Research results of the variability distribution of dry substance in washing waters have been presented in the function of duration of filter washing, as well as results of sediment settling research. The conducted research allowed to optimise the frequency and duration of washing, and as a result to improve the efficiency of settling tank functioning. It also contributed to a less consumption of water for the station’s technological purposes.
EN
Potential applications of concentrating tables were earlier investigated and the results of tests and analyses were summarised during former conferences. The prototype inertial-resilient drive system was of particular importance. Designs of generators utilising dynamic excitations employed in concentrating tables are compared in this paper. The operating principle and design options of these vibrating machines are outlined.
EN
Selected components of physical-chemical contents of tested washings. Thickening of unconditioned and polyelectrolytes-conditioned washings. Influence of polyelectrolytes dose and sort on the agglomerates sedimentation speed.