Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 38

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ultrasonografia
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available Czy ultrasonograf to współczesny stetoskop?
PL
Autor porównuje zasadę działania następujących technik diagnostycznych: ultrasonografii, osłuchiwania oraz opukiwania. W konkluzji stwierdza, że ultrasonografia to nowoczesna forma opukiwania.
EN
The author compares the principles of operation of the following diagnostic techniques – ultrasound, auscultation and percussion. He concludes that ultrasound is a modern form of percussion.
PL
Kontrola jakości aparatury ultrasonograficznej budzi wiele kontrowersji. W Polsce opiera się ona na błędnym założeniu, że ultrasonografia jest nieszkodliwa, nie powinna zatem podlegać takiej kontroli jak metody diagnostyczne bazujące na promieniowaniu jonizującym. Powyższe nie eliminuje jednak potrzeby prowadzenia testów kontroli jakości. Kryterium braku szkodliwości nie zmienia faktu, że nieprawidłowe funkcjonowanie systemu obrazowania może stanowić zagrożenie dla zdrowia i życia pacjentów ze względu na błędną diagnozę. W artykule zaproponowano schemat postępowania w zakresie oceny ultrasonografów, sond, protokołu pomiarowego oraz uzyskanych wyników i weryfikacji poprawności rejestracji obrazu.
EN
The quality control of the ultrasound equipment is controversial. In Poland, it is based on the erroneous assumption that ultrasonography is harmless, therefore it should not be subject to such control as diagnostic methods based on ionizing radiation. However, the above does not eliminate the need to conduct quality control tests. The non-harmfulness criterion does not change the fact that improper functioning of the imaging system may pose a threat to the health and life of patients due to incorrect diagnosis. The article proposes a procedure for the assessment of ultrasound scanners, probes, measurement protocol, the obtained results and verification of the correctness of image registration.
3
Content available remote Deep learning on ultrasound images of thyroid nodules
EN
Due to safety, easy accessibility, noninvasively and cost-effectiveness of ultrasound imaging, this technology becomes one of the main contributors for analyzing thyroid nodules. However, interpretation of ultrasound images is a challenging task that subjects to the radiologist’s prior medical knowledge and observational skills. There is a significant need for reliable, objective, and automated approaches for the meaningful assessment of ultrasound images. Many areas of machine learning including computer vision and image processing have been revolutionized by the recent advances in the field of deep learning. The current study systematically reviews the existing literatures and evaluates technical characteristics of the deep learning applications on the ultrasound images of thyroid nodules. In this review, all of the included studies have been published from 2017 to 2020 indicating the recent growing interest in the utilization of deep learning-based techniques for assessment of ultrasound images of thyroid nodules. Although deep learning has demonstrated potential for analyzing thyroid nodules’ ultrasound images, this review highlights several existing barriers that need to be addressed in future works such as dealing with data limitation, generating public and valid datasets, and determining standard evaluation metrics. This survey outlines several methods (e.g., data augmentation and transfer learning) recently proposed to address similar challenges in other fields. Furthermore, to improve the diagnostic accuracy of the deep learning models, utilization of complementary information with multi-modal images are suggested.
PL
W ciągu ostatnich kilku dziesięcioleci ultradźwięki znalazły szerokie zastosowanie w diagnostyce obrazowej. Ten artykuł przeglądowy omawia potencjalne efekty biologiczne związane z propagacją ultradźwięków w tkankach i podaje fizyczne podstawy wprowadzonych indeksów mechanicznego MI i termicznego TI zgodnych z Output Display Standard (ODS). W praktyce klinicznej otrzymywane wyniki są kompromisem pomiędzy jakością obrazu a możliwością systemu uzyskiwania zadowalających obrazów głęboko leżących struktur tkankowych – wyboru dokonuje się, biorąc pod uwagę minimalizację bioefektów. Moce wyjściowe ultrasonografów są regulowane i ograniczane do określonych poziomów. Bezpieczne dawki ultradźwiękowe wyznacza się według określonych zasad, a na ekranie wyświetlane są związane z nimi wielkości. Wielkości te określają możliwości wystąpienia zmian mechanicznych i termicznych w tkankach i dlatego mają znaczenia kliniczne. Wprowadzone wskaźniki – mechaniczny MI i termiczny TI uwzględniają fizyczny mechanizm oddziaływania między ultradźwiękami i biologiczną tkanką, który zależy od czasowych i przestrzennych parametrów pola akustycznego generowanego przez głowice ultradźwiękowe. Przewidywany wzrost temperatury określa się, stosując trzy różne modele tkankowe: homogeniczny, warstwowy i układ kość/tkanka.
EN
Ultrasounds have found widespread use in imaging diagnostics over the past few decades. This review article combines the reports on the biophysical effects and provides the rationale behind the mechanical index (MI) and thermal index TI complying with Output Display Standard (ODS). In clinical practice, the obtained diagnostic results are a compromise between the quality of the image and the possibility of a system of obtaining satisfactory images of deep-lying tissue structures – the choice is made taking into account the minimization of bioeffects. The output powers of ultrasonographs are regulated and limited to specific levels. Safe ultrasonic doses are determined according to specific rules, and the screen displays the associated quantities. These quantities determine the possibility of mechanical and thermal changes in the tissues and therefore have clinical significance. The introduced indexes MI and TI take into account the physical mechanism of interaction between ultrasounds and biological tissue, which depends on the temporal and spatial parameters of the acoustic field generated by ultrasound transducers. The predicted temperature increase is determined using three different tissue models: homogeneous, layered and bone/tissue interface.
PL
W artykule przedstawiono procedurę badania ultrasonografi cznego FAST oraz eFAST.
EN
The ultrasound examination procedure FAST and eFAST is presented in the article.
PL
Badania z zastosowaniem środków kontrastujących znacznie poszerzają możliwości ultrasonografii jako metody diagnostycznej. Autor przedstawił podstawy fizyczne, mechanizmy obrazowania oraz opisał możliwości zastosowania ultrasonografii z wykorzystaniem środków kontrastujących.
EN
Studies using contrast agents significantly expand the possibilities of ultrasonography as a diagnostic method. The author presented physical fundamentals, imaging mechanisms and described possibilities of using Contrast Enhanced Ultrasound.
PL
Badania ultrasonograficzne z wykorzystaniem zjawiska propagacji fali ścinającej w ośrodkach o różnej impedancji akustycznej – oporności tkanek w czasie przechodzenia przez nie fali mechanicznej – ultradźwiękowej, są w stanie wykazać metodami obrazowymi obecność zmian, które mogą być stwierdzone jedynie w badaniach histopatologicznych. Autor przedstawia podstawy fizyczne, mechanizmy obrazowania oraz podstawowe zastosowania metody.
EN
Ultrasound examinations, using the shear wave propagation phenomenon in medium with different acoustic impedance – tissue resistance during the passing of a mechanical wave – ultrasound wave, are able to show, by means of imaging methods, the presence of changes that can be found only in histopathological studies. The author presents physical fundamentals, imaging mechanisms and basic applications of the modern ultrasound examination method.
PL
W ciągu ostatnich trzydziestu lat dokonał się znaczący postęp w diagnostyce obrazowej narządu wzroku. Dzięki innowacyjnym technologicznie aparatom oraz rozwojowi zaawansowanych programów informatycznych, obrazy zwizualizowanych tkanek mają dziś bardzo dobrą jakość. Możliwe jest wizualizowanie struktur wewnętrznych oka z bardzo dużą precyzją, co umożliwia precyzyjną diagnostykę we wczesnym stadium choroby, a także monitorowanie wielu procesów chorobowych [1]. Nowoczesne technologie umożliwiają osiągnięcie rozdzielczości na poziomie fotoreceptora, co pomaga w lepszym zrozumieniu podstaw choroby i pozwala na tworzenie nowych metod leczniczych. Oko jest unikalnym narządem, który dzięki swej budowie pozwala na nieinwazyjne wykonanie badań nie tylko przedniej części oka, ale i tylnego jej bieguna, czyli siatkówki i nerwu wzrokowego [2].
EN
Estimation of thermal response of tumoral tissue to the hyperthermia treatment is an important factor for increasing the effectiveness of therapeutic method. In this study, focused ultrasound (FU) is used to produce irreversible thermal damage for the treatment of benign thyroid tumor. To this end, a multi-layer model of the neck including internal organs from the skin toward the thyroid gland is exposed to ultrasound irradiation at powers of 3 W, 5 W, and 7 W and at the frequency of 3 MHz. It is observed that the acoustic pressure is noticeably increased by considering different neck's internal organs. The temperature profile is obtained by taking into account the non-Fourier thermal response for the thyroid gland. The thermal wave model and dual phase lag model are utilized along with the traditional Pennes bio-heat transfer model. Studying the temperature profile at 3 W power by non-Fourier thermal models illustrates that the maximum temperature with time delays of 11.32, 5.66 and 2.86 s is 20.51%, 14.1% and 8.65% lower than the corresponding value by the Fourier model. Deviation from the Fourier results is increased for higher powers of transducer. It is also inferred that in the presence of time delays, temperature variation in the focal area becomes smoother. Effect of non-Fourier heat transfer is studied on the area of necrotic tumoral region. It is concluded that region with irreversible thermal damage shrinks by considering the phase lags in the way that in 3 W power and 5.66 s time delay, no necrosis of the thyroid nodule is observed.
10
Content available Kontrola jakości w ultrasonografii
PL
Kontrola jakości w rentgenodiagnostyce funkcjonuje już od wielu lat. Weryfikacja parametrów fizycznych urządzeń radiologicznych pozwoliła na poprawienie stanu technicznego aparatury rentgenowskiej oraz jakości wykonanych badań. Przy coraz większym zastosowaniu fal ultradźwiękowych pojawia się ryzyko postępującej degradacji, która może ingerować w jakość obrazu, a co za tym idzie – może wpływać na diagnozę medyczną. Wykonując testy rutynowe, możemy obserwować stopniowe zmiany w pracy systemu, co pomoże wykryć wcześniej problemy w prawidłowym funkcjonowaniu systemu. Testy mogą pomóc w procesie podejmowania decyzji o wymianie lub zamówieniu nowych sond. W przypadku aktualizacji systemów lub zmiany modalności systemu, testy potwierdzają poprawność działania urządzenia. Testy dają pewność, że system działa w sposób spójny i prawidłowy. Podczas użytkowania ultrasonografów może dochodzić do częściowej degradacji systemów z powodu ich transportu np. z oddziału na oddział. Wydaje się zatem, iż warto jest zainteresować się sprawnością ultrasonografów jako jednych z podstawowych narzędzi diagnostycznych w placówkach ochrony zdrowia. Istnieje kilka międzynarodowych zaleceń dotyczących kontroli jakości aparatów ultrasonograficznych. Niektóre z nich opracowane zostały kilkanaście lat temu, inne doczekały się już aktualizacji. W artykule przytoczono przykładowe testy urządzeń USG, zgodnie z zaleceniami towarzystw międzynarodowych, a następnie przedstawiono własne propozycje testów aparatury.
11
EN
Ultrasonography has proved its usefulness in the evaluation of joint inflammations caused by rheumatoid arthritis. The illness severity is scored by human examiners based on their experience, but some discrepancies in the final diagnosis and treatment frequently occur. Therefore, the main aim of this work is the elaboration of an automatic method of the localization of finger joint inflammation level in ultrasound images. In this paper we propose a novel, fully automated framework for synovitis region segmentation. In our approach we compare several bones and joint localization methods based on the seeded region growing technique, which is combined with different speckle noise filtering algorithms. This technique extracts a region from the image using some predefined criteria of similarity between initially selected point and the pixels in its neighborhood. The seed point is localized automatically as the darkest patch within a small region between two detected finger bones close to the joint. The region affected by synovitis is found using the adopted criterion of homogeneity based on a patch to patch similarity measure. The obtained results exhibit a satisfying accuracy in comparison with the annotations prepared by an expert and the results delivered by semi-automatic methods that require manual bones delineation.
EN
Ultrasound imaging is widely used for breast lesion differentiation. In this paper we propose a neural transfer learning method for breast lesion classification in ultrasound. As reported in several papers, the content and the style of a particular image can be separated with a convolutional neural network. The style, coded by the Gram matrix, can be used to perform neural transfer of artistic style. In this paper we extract the neural style representations of malignant and benign breast lesions using the VGG19 neural network. Next, the Fisher discriminant analysis is used to separate those neural style representations and perform classification. The proposed approach achieves good classification performance (AUC of 0.847). Our method is compared with another transfer learning technique based on extracting pooling layer features (AUC of 0.826). Moreover, we apply the Fisher discriminant analysis to differentiate breast lesions using ultrasound images (AUC of 0.758). Additionally, we extract the eigenimages related to malignant and benign breast lesions and show that these eigenimages present features commonly associated with lesion type, such as contour attributes or shadowing. The proposed techniques may be useful for the researchers interested in ultrasound breast lesion characterization.
PL
Ultrasonografia Dopplerowska jest jednym z najlepszych sposobów diagnozy zmian miażdżycowych oraz szczegółowej kontroli patologii zmian ścian naczyń krwionośnych. Wykonanie badania wymaga szeregu czynności wykonywanych współbieżnie, m.in. analizy obrazów USG oraz ręcznego sporządzania notatek na potrzeby podsumowania badania. Analiza problemu wykazała, że przebieg badań ultrasonograficznych może zostać częściowo zautomatyzowany przez dedykowane oprogramowanie, co przedstawia niniejszy artykuł.
EN
Doppler ultrasonography is one of the best ways of diagnosing the atherosclerosis and inspecting the details of the vessel wall pathology. Carrying out the examination requires plenty of activities that have to be done simultaneously, i.a. analysing the USG images and manually taking notes to the examination report. The analysis of the problem enables stating that the Doppler ultrasound examination can be partially automated with the aid of dedicated software system, what is the point of the article.
EN
Images of different sections of the examined tissue, and in the result, the spatial image of the examined organ on the flat screen of the monitor, are obtained using the mobile apparatus head, which is moved by the physician over the patient’s body surface. The obtained image exactly reproduces the reality, but its interpretation always depends on the physician. Only the proficient knowledge of anatomy enables the correct interpretation of the image. For example, a cyst looks like a homogeneous dark spot with regular shape and smooth edges, while the tumour has a heterogeneous structure, visible as different shades of grey and ragged edges. Of course, the interpretation of the image is not always as simple as that, and therefore, among the professionals it is considered, that good diagnostics is more important than even the most modern equipment. However, the technology and methodology of processing and visualization of images is not without significance. By using the wavelet filtration to transform original images – their photointerpretation becomes easier, and more accurate.
PL
Obraz różnych przekrojów badanej tkanki, a w efekcie przestrzenny obraz badanego narządu na płaskim ekranie monitora, uzyskuje się dzięki ruchomej głowicy aparatu, którą przesuwa lekarz po powierzchni ciała chorego. Uzyskany obraz wiernie odtwarza rzeczywistość, jednak jego interpretacja zawsze należy do lekarza. Jedynie dobra znajomość anatomii pozwala prawidłowo zinterpretować obraz. Przykładowo torbiel wygląda, jak jednorodna ciemna plama o regularnym kształcie i gładkich brzegach, natomiast guz nowotworowy ma strukturę niejednorodną, widoczną jako różne odcienie szarości i poszarpane brzegi. Oczywiście nie zawsze interpretacja obrazu jest tak prosta i dlatego wśród specjalistów uważa się, że dobry diagnostyk jest ważniejszy od najnowocześniejszego sprzętu. Jednakże nie bez znaczenia pozostaje technologia i metodyka opracowywania – wizualizacji obrazów.
PL
Mięśnie w obrębie kompleksu lędźwiowo-miedniczno-biodrowego pełnią rolę podtrzymującą dla narządów miednicy mniejszej, odpowiadają za kontyngencję pęcherza oraz pełnią funkcję mięśni oddechowych. Mięśnie dna miednicy są również uważane za ważną część mechanizmu stabilizacji głębokiej kręgosłupa. U pacjentów z zaburzeniami funkcji mięśni dna miednicy mamy do czynienia z dolegliwościami bólowymi w obrębie kręgo-słupa lędźwiowego i miednicy, z objawami nietrzymania moczu oraz z zaburzeniami toru oddychania. Celem pracy jest przedstawienie metodyki zastosowania obrazowania ultrasonograficznego w ocenie funkcji mięśni dna miednicy. Ultrasonografia staje się coraz bardziej popularna w pracy fizjoterapeutów, zarówno w diagnostyce zaburzeń mięśni głębokich kompleksu lędźwiowo-miednicznego jak i jako narzędzie służące do biofeedbacku podczas terapii.
EN
The muscles of the lumbopelvic region play a significant role in musculoskeletal function as well as continence and respiration. The pelvic floor muscles also provide trunk stability. In patients with failure of pelvic floor muscles function we observe low back pain, incontinence and breathing disorders. The aim of this study was to present the methodology of ultrasound evaluation of pelvic floor muscles. Ultrasonography becomes popular in physiotherapy practice both in evaluation of lumbopelvic complex dysfunction and as a biofeedback tool during the therapy.
PL
Zapotrzebowanie na specjalistyczną opiekę medyczną w dzisiejszych czasach staje się coraz większe. Dodatkowo obserwowany jest rosnący niedobór lekarz w większości krajów na całym świecie. Rozwiązaniem takiej sytuacji wydaje się być telemedycyna. Projekt ReMeDi ma na celu zbudowanie systemu robotycznego do zdalnej diagnostyki medycznej, który będzie wspierać lekarza poprzez umożliwienie zdalnej obecności przy wykorzystaniu inteligentnych i autonomicznych funkcji poznawczych. Ten artykuł skupia się na interfejsach systemu ReMeDi przeznaczonych do zdalnej ultrasonografii i prezentuje prace wykonane w ciągu dwóch lat trwania projektu.
EN
Nowadays the demand for specialized medical care becomes higher. Additionally increasing deficit of physician is observed in majority of countries worldwide. The solution for such a situation seems to be telemedicine. The ReMeDi project is aimed to developa robotic system for remote medical diagnostics, which can support physician by enhancing the (tele-) presence with intelligent cognitive autonomous features. This paper focuses on the interfaces of the ReMeDi system which are dedicated for remote ultrasonography and presents the work done during the two years of the project.
17
Content available remote Rodzaje sond w ultrasonografii
PL
W obrazowaniu ultrasonograficznym stosuje się fale ultradźwiękowe o częstotliwościach od pojedynczych MHz do ok. 30 MHz. Jeżeli nie jest wymagana wysoka rozdzielczość, jak np. w badaniu jamy brzusznej, używa się niskich częstotliwości – ich tłumienie jest stosunkowo niewielkie, co umożliwia wykonanie badań struktur zlokalizowanych głębiej wewnątrz ciała. Jeśli jednak zależy nam na wysokiej rozdzielczości, np. podczas obserwacji zmian rakowych skóry lub oka, gdzie zasięg fali może być krótki, zachodzi konieczność stosowania fal o najwyższych częstotliwościach. Miarą sprawności zamiany energii elektrycznej w energię akustyczną jest współczynnik sprzężenia elektromechanicznego.
18
Content available remote Kliniczne zastosowanie pomiarów ultrasonograficznych
PL
Pomiary wykonywane w ultrasonografii mogą decydować o rozpoczęciu lub niepodejmowaniu leczenia. Istnieje zatem konieczność wykonywania pomiarów na niezależnych fantomach, co zauważyli już Amerykanie, Anglicy oraz kilkanaście towarzystw naukowych z innych państw. Stowarzyszenia zawodowe przygotowały swoje zalecenia do kontroli jakości w ultrasonografii, niestety Polska, na chwilę obecną, jeszcze takich nie opracowała.
19
PL
W artykule omówiono wybrane zagadnienia dotyczące wykorzystania fal ultradźwiękowych w inżynierii biomedycznej. W wielu przypadkach ultrasonografia jest jedyną możliwą do zastosowania metodą obrazowania, a nowoczesne ultrasonografy są złożonymi urządzeniami sterowanymi komputerowo. W pierwszej części pracy opisano wybrane zastosowania ultrasonografii w położnictwie. Wykorzystanie efektu przesunięcia dopplerowskiego umożliwia wykrycie ruchu narządu odbijającego wiązkę ultradźwięków i może zostać użyte do nieinwazyjnego wykrywania uderzeń serca płodu. Przedstawiono różne rodzaje prezentacji pozyskiwanych danych. W drugiej części pracy skupiono się na dezintegracji kamieni nerkowych za pomocą ultradźwiękowych fal uderzeniowych. Omówiono problematykę jednoczesnego generowania i ogniskowania fal ultradźwiękowych oraz precyzyjnej lokalizacji kamieni nerkowych. Poruszono również kwestię bezpiecznego stosowania ultradźwięków na potrzeby diagnostyki medycznej, skupiając się na środkach ochrony przed szkodliwym wpływem „hałasu” ultradźwiękowego i na bezpieczeństwie badań ultradźwiękowych.
EN
This paper describes the selected problems concerned with the common use of ultrasounds in biomedical engineering. The modern USG units are the complex computer-controlled devices. In a lot of cases ultrasonography is only one method which may be safely used in medical imaging. Firstly, some selected applications of ultrasonography in obstetrics are presented. Different kinds of the acquired data presentation are described. Secondly, specific questions concerning disintegration of the kidney stones by the use of the ultrasonic shock waves are mentioned. Safe applying the ultrasounds has been also raised, focusing on the means of the protection from the harmful influence „noise” of ultrasounds and on the safety of ultrasonic investigations.
20
Content available remote Ultrasonografia w Polsce
PL
Ultrasonografia jest obecnie najczęściej stosowaną i najłatwiej dostępną diagnostyczną techniką obrazowania narządów człowieka. Jest szczególnie istotna w procesie badań przeglądowych mających na celu szybkie wykrywanie zagrożeń we wstępnym okresie rozwoju choroby, a nie tylko w procesie diagnostyki postępów choroby i jej leczenia. Po niespełna czterdziestu latach od pierwszych nieśmiałych zastosowań ultrasonografii wartość sprzedaży aparatury ultrasonograficznej w Europie wyniosła ponad 35% całkowitej wartości sprzedanej aparatury obrazowej. Badania globalnego rynku, prowadzone przez tak renomowane firmy jak BCC Market Research and Forecasting, In Medica-IMS Medical czy Global Industry Analysts Inc., przewidują dalszą ekspansję rynku sprzętu ultradźwiękowego z dzisiejszych 6-7 miliardów dolarów do nawet 27 miliardów dolarów w 2016 roku. To potężne i wymagające światowe przedsięwzięcie. Jego sukces lub porażka bezpośrednio dotyka każdego z nas – pacjentów oczekujących obiektywnej oceny stanu narządów wewnętrznych.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.