Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  testy korozyjne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
Amorphous materials based on magnesium are new materials for potential biomedical application, especially for new implants, as they bear resemblance to titanium implants. Mg66Zn30Ca4 alloy has specific properties, especially mechanical and corrosive, therefore, it has biomedical application as its properties are better than that of other materials. The following paper describes amorphous alloy based on magnesium, properties and shows how to produce amorphous samples of Mg66Zn30Ca4.
2
Content available remote Microstructure and properties of CoCr alloys used in prosthetics procedure
EN
Purpose: The aim of this work was to define the influence of manufacturing technology on the chemical composition, surface topography, physicochemical and electrochemical properties of CoCr alloys obtained by casting technology and Direct Metal Laser Sintering. Design/methodology/approach: This work presents microstructural and chemical compositions obtained by scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDS). Additionally, corrosion pitting analysis and roughness measurement were conducted on the samples. Findings: On the basis of the investigations, it can be stated that the prosthetic restorations are different depending on the type manufacturing technology. Based on the obtained results it was found that the structures of both materials are chemically inhomogeneous. The investigated alloy exhibited similar polarization curve character. Practical implications: The rapid prototyping methods are a new technology used for getting details e.g. by CAD/CAM procedure. Using Direct Metal Laser Sintering (DMLS) method can simplify the technology of producing prosthetics restrictions and is an alternate way for standard casting technology. Originality/value: The paper presents comparative research of two Co-Cr alloys, from which the samples were obtained in conventional casting and DMLS technology.
PL
W badaniach analizowano antykorozyjne i tribologiczne właściwości powłok cynkowych nanoszonych na żeliwo (GJL-250) i stal (DC01). Porównywano następujące rodzaje powłok cynkowych: galwaniczną (PN-EN ISO 4042), ogniową (PN-EN ISO 10684) i płatkową (PN-EN ISO 10683). Prezentowane wyniki są efektem drugiego etapu eksperymentu, który dotyczył badań tribologicznych, analizy mikrostruktury powłok cynkowych przy zastosowaniu mikroskopu optycznego w miejscach uszkodzeń i oceny zmniejszenia odporności korozyjnej na skutek uszkodzenia powłoki cynkowej. Badania korozyjne prowadzono w komorze solnej, w mgle obojętnej NaCl (wg PN-EN ISO 9227). Stwierdzono, iż odporność na korozję powłok naniesionych na stal jest znacznie większa niż powłok naniesionych na żeliwo. Powłoka cynku płatkowego jest najbardziej odporna na zużycie ścierne, ale pomimo tego jej odporność korozyjna istotnie maleje po teście tribologicznym. Powłoki galwaniczna i ogniowa są mniej odporne na mechaniczne uszkodzenia, jednakże fakt ten nie przekłada się znacząco na ich odporność korozyjną.
EN
The research work compares anticorrosion and tribological properties of different zinc coatings created on cast iron (GJL-250) and steel (DC01). The following methods of zinc coating were applied: galvanic (PN-EN ISO 4042), hot-dip (PN-EN ISO 10684) and lamellar (PN-EN ISO 10683. Presented results are an effect of the second stage of experiment which refers to: tribological laboratory research, metallographic analysis of zinc coating microstructure in damaged areas, with the use of optical microscope, and the evaluation of the decrease in corrosion resistance as the result of destruction the continuousness of zinc layer. The corrosion research was conducted with the salt chamber with neutral NaCl (PN-EN ISO 9227). It was stated that corrosion resistance of coatings put on steel is much more higher than this one tested on cast iron. The lamellar coating is the most resistant to mechanical damage but beside this it’s corrosion resistance decreases essentially after the friction test. Galvanic and hot – dip coatings are less resistant to mechanical damage but this fact not affects their corrosion resistance significantly.
PL
W artykule przedstawiono nowo opracowane laboratoryjne stanowisko badawcze przeznaczone do badań korozyjnych, które składa się z pieca grzewczego L/05/12, precyzyjnej wagi laboratoryjnej PS 210/C/2 oraz programatora. Zaprezentowano możliwości badawcze stanowiska oraz wybrane wyniki badań wysokotemperaturowych testów korozyjnych materiałów powłokowych.
EN
The new elaborated laboratory research stand for the corrosion tests was presented. The furnace L/05/12 and the laboratory precision Libra PS 210/C/2 for the basie construction of the stand are used. The research capabilities of the stand and the selected investigation results of experimental high tem­perature corrosion tests of the chosen corrosion resistance coatings were presented.
EN
New classes of singular fractional continuous-time and discrete-time linear systems are introduced. Electrical circuits are example of singular fractional continuous-time systems. Using the Caputo definition of the fractional derivative, the Weierstrass regular pencil decomposition and Laplace transformation the solution to the state equation of singular fractional linear systems is derived. It is shown that every electrical circuit is a singular fractional systems if it contains at least one mesh consisting of branches with only ideal supercondensators and voltage sources or at least one node with branches with supercoils. Using the Weierstrass regular pencil decomposition the solution to the state equation of singular fractional discrete-time linear systems is derived. The considerations are illustrated by numerical examples.
6
Content available remote Charakterystyka odporności korozyjnej galwanicznych powłok Zn-Ni
PL
Przeprowadzone badania miały na celu określenie odporności korozyjnej galwanicznych powłok Zn-Ni w atmosferze mgły solnej. Charakterystykę przeprowadzono w 5% NaCl w komorze solnej KÖHLER model HK 400. Czas trwania testu wynosił 96 godzin. Badania przeprowadzono dla powłok osadzonych na podłożu ze stali ST3S z kąpieli amoniakalnej przy j = -10 i -30 mAźcm-2. Dla otrzymanych powłok Zn-Ni określono skład fazowy i chemiczny oraz przeprowadzono badania morfologii powierzchni z wykorzystaniem mikroskopu skaningowego. Badania strukturalne wykazały, że otrzymane powłoki charakteryzują się występowaniem tylko jednej fazy (Ni2Zn11). Dla stosowanych gęstości prądowych skład chemiczny powłok mało zależy od warunków prądowych ich otrzymywania, a zawartość niklu w badanych powłokach Zn-Ni wynosi około 17 %. Badania strukturalne powłok po testach korozyjnych w komorze solnej wykazały obecność dodatkowej fazy Zn5(OH)8Cl2źH2O na powierzchni powłok. Obecność tej fazy świadczy o tworzeniu na powierzchni powłok Zn-Ni pasywnej warstewki zwiększającej odporność korozyjną powłok.
EN
Zn-Ni galvanic coatings have been deposited under galvanostatic conditions (j = -10 and -30 mAźcm-2) an alkaline bath on ST3S steel surface . It was stated, that chemical composition of obtained coatings small dependent on the galvanic conditions. The content of nickel in Zn-Ni coatings was in the range 15-17%. Surface morphology studies were performed using a scanning microscope. The chemical composition of the coatings was determined by EDXS. The results of structural investigation of the obtained coatings by the X-ray diffraction method show, that as-deposited Zn-Ni coatings consist of Ni2Zn11 phase. After NNS test Zn-Ni coatings consist of Ni2Zn11 and Zn5(OH)8Cl2źH2O phase. The corrosion resistance of the coatings was examinated in 5% NaCl solution. In order to compare corrosion properties of Zn-Ni as-deposited, Zn-Ni after NNS test and Zn coatings the potentiodynamic technique were used. It was found, that higher corrosion resistance of Zn-Ni coatings results from improved protective properties of the corrosion products layer what is caused by addition of nickel in zinc matrix. It was stated that corrosion resistance of the Zn-Ni coatings after salt spray test is higher in comparison with the as-deposited coating what could be attributed to the presence of Zn5(OH)8Cl2źH2O phase formed on the coating surface.
PL
W artykule przedstawiono wyniki badań laboratoryjnych szybkości procesów korozyjnych zachodzących w rurach wydobywczych odwiertów naftowych na skutek prowadzenia zabiegów kwasowania. Przebadano korozyjność stosowanych obecnie cieczy kwasujących, porównano stopień ochrony inhibitorów korozji i wskazano najbardziej skuteczne. Przeprowadzone zostały korozyjne testy zanurzeniowe z użyciem kuponów metalowych, wykonanych z 3 odmian wytrzymałościowych stali, stosowanych często na materiał rur wydobywczych. Roztwory testowe stanowiły sporządzone laboratoryjnie ciecze kwasujące z dodatkiem inhibitora korozji i środka powierzchniowio-czynnego, których skład wybrano na podstawie przeglądu cieczy wykorzystywanych obecnie w kraju do przeprowadzania zabiegów kwasowania odwiertów.
EN
Issues of laboratory test corrosion processes in tubes as a results of oil wells acidizing were submitted in this article. Corrosivity of acidizing fluids currently use were tested, grades of inhibitors protection were compared and the best inhibitors were indicated. Laboratory tests were performed on immersed metal coupons made of 3 types of steel with different mechanical strength, which were often used on tubulars. The acidizing fluids with additions of corrosion inhibitors and surface-active agents were prepared in the laboratory and their compositions were chosen on the basis of fluids which presently use for the procedure of well acidizing in our country.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.