Taking under consideration, that reliable transmission of energy is fundamental to proper operation of national power grid, quality control is essential for newly installed and in-service cable connections. It is known that routine tests (insulation coordination) completely check the quality of a power cable and accessories at the manufacturer. Nevertheless, the risk of problems with the delivery and installation of accessories can affect the quality of a newly installed power cable circuit. Based on international experience gathered on various power grids over the past 20 years, this article focuses on the use of non-destructive testing for after-installation - and diagnostic tests of all types of transmission cables. This document discusses in particular various actual aspects of testing new connections as well as the condition assessment of service aged HV power cables.
PL
Wiadomo, że podczas standardowych badań fabrycznych (koordynacja izolacji) jakość elektroenergetycznych kabli, a także osprzętu kablowego jest w pełni oceniana przez producenta. Niemniej jednak ryzyko problemów z dostawą i montażem poszczególnych elementów linii kablowej może wpłynąć na jakość nowo zainstalowanej linii. Obecne normy IEC są standardami sformułowanymi głównie przez producentów i nie zawierają odpowiednich zaleceń badań linii kablowych nowo zainstalowanych oraz już eksploatowanych, które by pozwoliły wykryć wady spowodowane wyżej wymienionymi problemami. Przyjęte w tych normach procedury badań odbiorczych skutkują tym, że przebicie/uszkodzenie może wystąpić tylko w przypadku bardzo poważnych wad (bardzo rzadko). Oznacza to, że w sytuacji braku uszkodzenia badanej linii podczas próby odbiorczej nie można wykryć wady w jakimś odcinku kabla lub w osprzęcie. Dlatego, w przeciwieństwie do norm IEC, standardy IEEE 400 i IEEE 400.4 zalecają po zainstalowaniu linii kablowej przeprowadzanie prób napięciowych połączonych z monitorowaniem wyładowań niezupełnych (WNZ), np. stosując napięcie ciągłe lub tłumione napięcie prądu przemiennego (DAC). W przypadku ciągłych napięć przemiennych, z powodu wysokiego poziomu zakłóceń elektromagnetycznych pojawiających się w wyniku generowania rezonansowych napięć przemiennych (ACRT), zgodnie z IEC 60270 wykrywanie WNZ nie jest wystarczająco czułe, aby można było zastosować tą metodę do wykrywania WNZ w izolacji kabli i we wszystkich typach osprzętu kablowego (czyli w głowicach i mufach). W przeciwieństwie do metody ACRT użycie metody DAC zapewnia, oprócz przeprowadzenia próby napięciowej, również bardzo czułe i zgodne z normą IEC 60270 wykrywanie WNZ w całym systemie kablowym. W oparciu na międzynarodowych doświadczeniach – zebrane w ciągu ostatnich 15 lat z badań przeprowadzonych w różnych sieciach energetycznych, w artykule skoncentrowano się na zastosowaniu metody DAC do badań odbiorczych i diagnostyki wszystkich rodzajów kablowych linii przesyłowych. Na praktycznych przykładach przedstawiono różne ważne aspekty badania nowych linii, a także dokonywanie oceny stanu elektroenergetycznych linii kablowych, będących w eksploatacji, wynikające z wieloletniego stosowania układów probierczych DAC w praktyce.
EN
It is known that using factory routine tests (insulation coordination) the quality of a power cable as well as the accessories is fully tested at the manufacturer. Nevertheless the risk of accessories parts delivery and installation problems may influence the quality of a newly installed power cable circuit. The current IEC standards are manufacturers'standards and they do not provide adequate recommendations for after-lying testing and demonstration of above-mentioned problems. A breakdown may occur only in case of extremely serious defects during the after-laying test (very seldom). This means that in a no-breakdown situation the presence of defects in cable parts or in accessories cannot be excluded. Therefore in contrast to the IEC standards the standards IEEE 400 and IEEE 400.4 recommend partial discharge monitored testing e.g. by continuous or damped AC voltages (DAC). In case of continuous AC voltages due to the high level of EM disturbances occurring by on-site generation of resonant AC voltages (ACRT), the PD detection in accordance to IEC 60270 is not sensitive enough to be used for PD detection in cable insulation and in all types of cable accessories. In contrast to ACRT the use of DAC provides in addition to voltage withstand test also very sensitive and IEC 60270 conform PD detection of the complete cable circuit. Based on the international experiences as collected in the last 15 years at different power grids this contribution focuses on the use of DAC for after-laying testing and diagnosis of all types of transmission power cables. In particular supported by practical examples different important aspect of testing new connections as well as condition assessment of service aged power cables will be mentioned in this paper.
EN
The ageing of double base (DB) rocket propellants, as a consequence of the chemical reactions and physical processes that take place over time, has a signifcant effect on their relevant properties, such as chemical composition and mechanical and ballistic properties. The changes to relevant properties limit the safe and reliable service life of DB rocket propellants. Accordingly, numerous research efforts have been undertaken to fnd reliable methods to measure the changes caused by ageing in order to assess the quality of DB rocket propellants at a given moment of their lifetime, and to predict their remaining service lifetime. In this work we studied the dynamic mechanical properties of DB rocket propellant artifcially aged at temperatures of 80, 85 and 90 °C, in order to detect and quantify changes in the dynamic mechanical properties caused by ageing, and to investigate the possibilities for the prediction of service lifetime. Dynamic mechanical properties were studied using a dynamic mechanical analyser (DMA). The results obtained have shown that ageing causes signifcant changes in the storage modulus (E´), the loss modulus (E˝) and the tan δ curves’ shape and position. These changes are quantifed by following some characteristic points on the E´-T, E˝-T, and tan δ-T curves (e.g. glass transition temperatures; storage modulus, loss modulus and tan δ at characteristic temperatures, etc.). It has been found that the monitored parameters are temperature and time dependent, and that they can be shown to be functions of the so called ‘reduced time of artifcial ageing’. In addition, it has been found that, on the basis of known changes in viscoelastic properties as a function of time and ageing temperature, and the known kinetic parameters of the ageing process, it is possible to calculate (determine) the change in the properties at any ageing temperature provided that the mechanism of the ageing process does not change. Unfortunately, the use of kinetic parameters obtained by artifcial ageing at high temperatures (above 60 °C) for the prediction of the propellant lifetime will not give reliable results, because the mechanisms of ageing at 85 °C and 25 °C are not the same.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.