Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 71

Liczba wyników na stronie
first rewind previous Strona / 4 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  system ocieplania
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 4 next fast forward last
PL
W artykule poruszono problematykę realizacji ociepleń ETICS z tynkami o niskim współczynniku odbicia światła. Dokonano przeglądu krajowych i zagranicznych zaleceń dotyczących ograniczeń w stosowaniu ciemnych tynków na elewacjach budynków oraz przedstawiono studium przypadku dla nowo realizowanego budynku wielorodzinnego.
EN
The article presents the problem of implementing ETICS insulation with plasters with a low light reflectance coefficient. A review of domestic and foreign recommendations regarding restrictions on the use of dark plasters on building facades was made and a case study was presented.
PL
W artykule zaprezentowano zagadnienie związane z krajowymi wytycznymi w zakresie mocowania warstwy izolacji termicznej za pomocą zaprawy klejącej do podłoża ściennego w systemie ETICS. Przedstawiono wymagania i zalecenia dotyczące klejenia termoizolacji na przestrzeni ostatnich ponad 30 lat, z dyskusją odnośnie rekomendacji przyjmowania grubości warstwy klejącej płyty izolacji termicznej do ściany.
EN
The article presents the issue related to national guidelines for attaching the thermal insulation layer with an adhesive mortar to the wall substrate in the ETICS system. Requirements and recommendations for gluing thermal insulation over the last 30 years are presented, with a discussion on the recommendations for the thickness of the adhesive layer of the thermal insulation board to the wall.
5
Content available remote Włókna celulozowe w systemach ociepleń
6
Content available remote Oczekiwane zmiany przepisów dotyczących jakości ocieplenia ETICS
PL
Pogarszanie izolacyjności cieplnej na skutek zawilgacania i biodegradacji w przypadku fasad ocieplanych ETICS następuje niejednokrotnie już w pierwszych latach eksploatacji. Przekłada się to na zmniejszenie efektywności energetycznej polskiego budownictwa, w którym ETICS jest dominujący. Prowadzone przeze mnie od prawie trzech dekad badania wskazują, że w wielu przypadkach już w momencie przekazywania budynków do użytkowania nie są spełnione wymagania dotyczące ciepłochronności. W artykule przedstawiono powody występowania wad skutkujących postępującym w czasie zwiększaniem zapotrzebowania na ciepło do ogrzewania. Wzorem wielu europejskich krajów wymagania stawiane elewacjom w zakresie trwałości powinny być doprecyzowane i rozszerzone o odporność na biodegradację. Z inspiracji członków Grupy Roboczej ds. krajowych inteligentnych specjalizacji (KIS 5 Inteligentne i energooszczędne budownictwo) przedstawiono propozycję oczekiwanych zmian prawnych, które mogłyby przynieść wymierne korzyści w poprawie efektywności energetycznej budynków.
EN
The deterioration of thermal insulation due to moisture and biodegradation in the case of ETICS insulated facades often occurs in the first years of operation. This transfers into a reduction in the energy efficiency of the Polish constructions, in which ETICS is dominant. The research carried out by the author for almost three decades shows that in many cases the requirements for thermal insulation are not met already at the moment of handing over the buildings to use. The article presents the reasons for the occurrence of defects resulting in the increasing heat demand for heating over time. Following the example of many European countries, the requirements for façades in terms of durability should be specified and extended to include resistance to biodegradation. Inspired by the members of the Working Group for national smart specializations (KIS 5 Smart and energy-efficient construction), the article presents a proposal for the expected legal changes that could bring tangible benefits in improving the energy efficiency of buildings.
7
Content available remote Klasyfikacja imperfekcji cieplnych systemu ETICS
PL
W artykule przedstawiono problematykę występowania imperfekcji strukturalnych złożonych systemów ociepleń ścian zewnętrznych. Analiza ilościowa nieprawidłowości, bazująca na badaniach in situ, którą przeprowadziłem, umożliwiła zaproponowanie klasyfikacji imperfekcji cieplnych systemu ETICS w postaci defektów i dyslokacji cieplnych, także z niekontrolowaną infiltracją powietrza. Znajomość charakterystycznych wielkości, które je opisują, pozwala na powiązanie ich z rzeczywistą izolacyjnością termiczną ścian zewnętrznych.
EN
The article dealsn with the issues related to the occurrence of structural imperfections of complex wall insulation systems. The aim of the work is to determine the influence of ETICS imperfections on the thermal protection condition of external walls. Additionally, a classification of thermal defects and dislocations,which constitute an irregularity in the implementation of ETICS systems, along with uncontrolled air infiltration occurring in selected cases, was proposed. The knowledge of the characteristic quantities describing them allows to correlate them with the actual thermal insulation of external walls.
8
Content available remote Detekcja defektów cieplnych systemu ETICS w warunkach quasi-stacjonarnych
PL
W artykule przedstawiono wstępne wyniki badań rozkładu temperatury na powierzchni ściany zewnętrznej z imperfekcjami systemu ETICS, prowadzonych w quasi-stacjonarnych warunkach pomiarowych. Badania wykazały zmianę rozkładu temperatury w obrębie defektów cieplnych o zróżnicowanych szerokościach oraz nieznaczny wpływ występującej dyslokacji cieplnej. Uzyskane wyniki wskazują na konieczność prowadzenia dalszych pomiarów w warunkach rzeczywistych.
EN
The article presents preliminary results of tests of temperature distribution on the surface of an external wall with imperfections of the ETICS system, carried out in quasi-stationary measurement conditions. The research showed a change in the temperature distribution within thermal defects of different widths and a slight influence of the occurring thermal dislocation. The obtained results indicate the necessity to conduct further measurements in real conditions.
PL
Sektor budowlany należy do gałęzi gospodarki o istotnym wpływie na środowisko. Wykorzystuje ogromne ilości zróżnicowanych surowców, wytwarza znaczne ilości odpadów i emituje znaczne ilości gazów cieplarnianych do atmosfery. Redukcja zużycia energii i emisyjności budynków, dekarbonizacja istniejących źródeł energii oraz optymalizacja wykorzystania energii odnawialnej, a także zminimalizowanie śladu węglowego materiałów i robót budowlanych to konieczność, aby przeciwdziałać zmianom klimatycznym. To również plan minimum dla zapewnienia zrównoważonego rozwoju społecznego. Dotychczasowa polityka środowiskowa w sektorze budowlanym jest niewystarczająca a wynika to, przede wszystkim, z obecnie obowiązujących regulacji prawnych. Ocena wyrobów budowlanych w zakresie siódmego wymagania podstawowego, dotyczącego zrównoważonego wykorzystania zasobów naturalnych, jest dobrowolna, a co za tym idzie niemal zawsze pomijana. Narzędzia do oceny jakimi są m.in. deklaracje środowiskowe III typu [Type III Environmental Product Declarations - EPDs] wyrobów budowlanych nie są powszechnie stosowane. Co więcej, dokumenty te są słabo rozpoznawalne wśród konsumentów, co świadczy o ciągle niewystarczającej świadomości ekologicznej. Dodatkowo, pojawiające się różnice wartości wskaźników oddziaływania środowiskowego określanych w deklaracjach środowiskowych III typu, wynikające ze zróżnicowanego podejścia w wyznaczaniu granic systemu czy jakości dostępnych danych generycznych, nie sprzyjają prawidłowemu rozwojowi wiedzy o wpływie materiałów budowlanych na środowisko. W niniejszej pracy przeprowadzono analizę oddziaływania środowiskowego cementu będącego składnikiem zapraw klejących, stosowanych w złożonych zestawach izolacji cieplnej ETICS. Badania prowadzono w zakresie czterech wskaźników, tj. globalnego współczynnika ocieplenia [GWP], potencjału zakwaszenie gleby i wody [AP], potencjału eutrofizacji [EP] oraz potencjał tworzenia ozonu troposferycznego [POCP].
EN
The construction sector is one of the branches of the economy with a significant impact on the environment. It uses a vast amount of different raw materials. Also, it produces substantial amounts of waste and emits high amounts of greenhouse gases into the atmosphere. Reducing the energy consumption and emissivity of buildings, decarbonizing existing energy sources, optimizing the use of renewable energy, and minimizing the carbon footprint of materials and construction works are imperative to counteract climate change. It is also a minimum plan for ensuring sustainable social development. The current environmental policy in the construction sector is insufficient and it results from the legal regulations currently in force. Assessment of construction products for the seventh basic requirement, sustainable use of natural resources, is voluntary and almost always neglected. Assessment tools, such as Type III Environmental Product Declarations [EPDs] for construction products, are not widely used. Moreover, these documents are poorly recognizable among consumers, proving that there is still insufficient environmental awareness. In addition, the emerging differences in environmental impact indicators values specified in environmental declarations, resulting from using differentiated approaches in setting system boundaries or the quality of available generic data, do not support the proper development of knowledge about the impact of construction products on the environment. In this work, an analysis of the environmental impact of cement, which is a component of adhesives used in the External Thermal Insulation Composite System [ETICS], was carried out. The study on four indicators, i.e., global warming potential [GWP], soil and water acidification potential [AP], eutrophication potential [EP], and tropospheric ozone formation potential [POCP], was performed.
PL
W celu określenia wpływu wzajemnego połączenia zróżnicowanych izolacji cieplnych w systmie ETICS na stan ochrony cieplno-wilgotnościowej zrealizowano badania w skali laboratoryjnej.
EN
In order to determine the influence of the mutual connection of different thermal insulations in the ETICS system on the condition of thermal and humidity protection, laboratory scale tests were carried out.
PL
W artykule przedstawiono wyniki obliczeń numerycznych ścian zewnętrznych ocieplonych styropianem z dodatkową barierą ogniową w postaci wełny mineralnej. Założono dwa rodzaje warstwy konstrukcyjnej, wykonanej w postaci monolitycznej żelbetowej i z bloczków z autoklawizowanego betonu komórkowego. W wyniku obliczeń otrzymano rozkłady temperatury w przekroju ściany, z wyznaczeniem charakterystycznych wartości w miejscach szczególnych. Dla przyjętych założeń wykazano nieznaczne zróżnicowanie temperatury na wewnętrznej powierzchni ściany oraz duże wartości czynnika temperaturowego fRsi.
EN
The article presents the results of numerical calculations of external walls insulated with polystyrene with an additional fire barrier in the form of mineral wool. Two types of construction layer were established, made of monolithic reinforced concrete and autoclaved aerated concrete blocks.As a result of the calculations, temperature distributions in the cross-section of the wall were obtained, with their characteristic values in specific places. For the assumptions made, a slight temperature variation on the inner surface of the wall and high values of the temperature factor fRsi were demonstrated.
PL
Popularne systemy ocieplania ścian zewnętrznych składają się z dwóch podstawowych warstw: termoizolacyjnej i wierzchniej – dekoracyjno-ochronnej, nakładanej na materiał do izolacji cieplnej. Termoizolację łączy się z ocieplaną ścianą najczęściej przez: przyklejenie przy użyciu zaprawy klejącej, masy klejącej albo kleju poliuretanoweg oraz zamocowanie przy użyciu łączników mechanicznych. Warstwą mającą kontakt z otoczeniem zewnętrznym jest tynk cienkowarstwowy, którego grubość przyjmuje się z przedziału od 1 do 5 mm w zależności od oferowanego na rynku systemu. Technologia wykonywania ocieplenia nie jest skomplikowana, jednak z praktyki budowlanej wynika, że w trakcie eksploatacji ujawniają się różne wady tynków, a przyczyna ich wystąpienia często nie jest jednoznaczna. Autorzy artykułu, po wykonaniu wielu ekspertyz warstw elewacyjnych budynków, chcieliby zwrócić uwagę na strukturę wewnętrzną tynku cienkowarstwowego i jego nieciągłości, by szukać w nich przyczyn występujących wad.
EN
Popular external wall insulation systems consist of two basic layers: thermal insulation and rendering system, connected to the insulated wall by means of adhesive layer and mechanical fasteners. The contact layer with the surroundings is a finishing coat, the thickness of which ranges from 1 to 5 mm, depending on the system offered on the market. The technology of wall insulation is not complicated, but construction practice shows, that many finishing coat defects are revealed during the exploitation, and the reason for their occurrence is not clear. The authors of the article, after making many expert opinions of the rendering systems of buildings, would like to draw attention to the internal structure of the thin-layer plaster and its discontinuities, in order to look for the causes of the defects in them.
16
Content available remote Odporność na uderzenie ETICS z wełną mineralną i okładziną nieciągłą
PL
W artykule zaprezentowano wyniki badania odporności na uderzenie systemu ociepleń ETICS z wełną mineralną lamelową (TR80) oraz zwykłą (TR10). Okładzinę stanowiły płytki klinkierowe oraz płytki cięte z cegieł ceramicznych. Badania przeprowadzono po cyklach hydrotermicznych oraz zamrażania-rozmrażania. Zastosowano nowe podejście do badania odporności na uderzenie z użyciem ciał twardych i miękkich. Na podstawie uzyskanych wyników testowane rozwiązania sklasyfikowano w najwyższej I kategorii użytkowania. Nie zaobserwowano wpływu rodzaju materiału termoizolacyjnego ani rodzaju płytek okładzinowych na rozpatrywaną właściwość.
EN
The paper presents the results of the impact resistance tests of ETICS made with the use of lamella (TR80) and regular (TR10) mineral wool. The cladding was made of clinker tiles and tiles cut from ceramic bricks. The tests were carried out after hydro-thermal and freeze-thaw cycles. A new approach was used to test the impact resistance with the use of hard and soft bodies. Based on the results, the tested solutions were classified in the highest category I of use. No influence of the type of thermal insulation material or the type of cladding tiles on the considered property was observed.
PL
W artykule przedstawiono oszacowanie oddziaływań i aspektów środowiskowych złożonych zestawów izolacji cieplnej ETICS z warstwą izolacyjną wykonaną z płyt ekspandowanego polistyrenu (EPS) lub wełny mineralnej (MW), pokrytych zaprawą do wykonywania warstwy zbrojonej oraz tynkiem silikonowo-silikatowym. Wskaźniki oddziaływania środowiskowego obliczono, wykorzystując metodę oceny cyklu życia (LCA). Analiza obejmowała moduły od A1 do A3, tj. od wydobycia surowców aż do gotowego wyrobu dostarczonego do bramy fabryki. Porównanie wartości wskaźników charakterystyk środowiskowych dotyczących wyprodukowania ETICS z płytami EPS lub MW wskazuje, że układy z wełną mineralną stanowią większe obciążenie dla środowiska.
EN
The paper shows the results of the estimation of environmental impacts and aspects of external thermal insulation composite system (ETICS) with expanded polystyrene (EPS) or mineral wool (MW) boards covered with an adhesive for a base coat and silicone-silicate render as the top layer. The environmental impact indicators of the considered systems were calculated using the Life Cycle Assessment (LCA) method. Analysis has covered modules from A1 to A3, i.e., from raw material extraction to the finished product delivered to the factory gate. Comparing the values of the environmental characteristics indicators for the production of ETICS with EPS or MW boards shows that systems with mineral wool constitute a more significant burden on the environment.
first rewind previous Strona / 4 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.