Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 36

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  studnia
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The objective of this study is to assess the threat of contaminating groundwater originating from the first exploitative aquifer level in the municipality of Bodzentyn within the Świętokrzyskie Voivodship. The analysis included 23 representative groundwater intakes from MHP 816 Bodzentyn sheet. The various potential sources of groundwater contamination were identified. The intrinsic vulnerability of the first aquifer to contamination and the water recharge area were determined. In the results intakes potentially threatened by anthropogenic pollution were indicated. Providing information on the potential risks of groundwater contamination will help better plan environmental and decision-making activities in this area. The results can serve as a basis for policy development, land use and sustainable resource management in the municipality of Bodzentyn.
PL
Celem niniejszego opracowania jest ocena zagrożenia zanieczyszczeniem wód podziemnych pochodzących z pierwszego eksploatowanego poziomu wodonośnego w gminie Bodzentyn na terenie województwa świętokrzyskiego. Analizą objęto 23 reprezentatywne ujęcia wód podziemnych z arkusza MHP 816 Bodzentyn. Zidentyfikowano różne potencjalne źródła zanieczyszczenia wód podziemnych. Określono wewnętrzną podatność pierwszego poziomu wodonośnego na zanieczyszczenie oraz obszar zasilania. W wynikach wskazano ujęcia potencjalnie zagrożone zanieczyszczeniami antropogenicznymi. Dostarczenie informacji na temat potencjalnego ryzyka zanieczyszczenia wód podziemnych pomoże lepiej zaplanować działania środowiskowe i decyzyjne na tym obszarze. Wyniki mogą służyć jako podstawa do rozwoju polityki, zagospodarowania przestrzennego i zrównoważonego zarządzania zasobami w gminie Bodzentyn.
EN
Purpose: This article aims to investigate the impact of polymer type and concentration in the fracturing fluid on the size and permeability of fractures during hydraulic fracturing. The aim is to predict the conductivity and productivity of the formed fractures in order to evaluate the cumulative gas production. Design/methodology/approach: The influence of polymer concentration in the fracturing fluid on the size and permeability of fractures was studied using the GOHFER software from Haliburton. Findings: The results of the study show that by combining the effect of increasing fracture size and decreasing the permeability of the proppant, a gas flow rate increase of 3.5 times was achieved. Research limitations/implications: High polymer concentrations lead to reduced permeability due to the accumulation of polymer residues and polymer skin. Practical implications: The conducted study on the impact of polymer concentration in the fracturing fluid on the size and permeability of fractures will allow for a more qualitative hydraulic fracturing process. Originality/value: This article presents how the concentration and type of polymer affect the width, thickness, length, and conductivity of fractures during hydraulic fracturing.
EN
Purpose: The objective of this article is the analysys of methods for preventing and eliminating hydrates formations, classifying them and choosing the best ones for use in underground gas storage facilities. Comprehensive measures for the stable operation of gas storage facilities in the presence of conditions for the occurrence of hydrates formations were developed. Zones, being potentially prone to the hydrates formation during the gas storage facilities operation were identified. Design/methodology/approach: The operational parameters of gas storage wells during gas withdrawal are analyzed. The identified wells were operated under difficult conditions due to the deposition of hydrates on the wellheads, in flowlines and process equipment of gas storage facilities. The places of the highest hydrates accumulation on underground gas storages were determined: from the bottomhole of wells to the gas purification unit of the gas gathering station. Hydrate-prone zones were identified by computational fluid dynamic (CFD) modeling at the location of regulating choke installations in underground gas storage facilities. Findings: The zones of the greatest hydrates accumulation on underground gas storages were determined: from the bottomhole of wells to the gas purification unit of the gas gathering station. The analysis of the methods used in gas storage facilities of Ukraine to prevent and eliminate hydrates formation was out. A set of measures was proposed to prevent the hydrates formation in storage facilities to ensure their stable operation. Based on the Euler approach (Mixture model) by CFD modeling, zones prone to hydrates formation were determined at the installation site of regulating chokes in underground gas storages. The influence of the degree of fittings opening on the location of potential zones prone to hydrates formation was estimated. The gas-dynamic processes in the internal cavity of the gas pipeline at the installation site of the control fittings were studied and their influence on the distribution of bulk particles of the gaseous and liquid phases was established. Based on the studies performed, it was recommended to change periodically the mode of well operation for a certain time by opening or closing the regulating choke under favorable conditions for the formation of hydrates, especially at low ambient temperatures. Research limitations/implications: The obtained results of experimental studies and calculations showed that in order to solve the problem of hydrates formation at gas storage facilities, it is advisable to use diverse measures through the introduction of modern intelligent systems for monitoring and controlling the technological process. Further refinement of the algorithm of the proposed monitoring and control system with its approbation in production was provided. Practical implications: The results of the experimental studies and CFD modeling carried out allowed providing a more reasonable approach to the application of various available methods and measures to prevent hydrates formation in underground gas storage facilities. This approach made it possible to develop new effective ways and measures to prevent such complication. Originality/value: Based on the conducted experimental studies and modeling, the major zones prone to hydrates formation in underground gas storages were determined. The developed measures will allow timely detection and prevention of hydrates formation at gas storage facilities are original.
PL
Obecnie nadal zdarzają się sytuacje sprzyjające odkrywaniu cennych obiektów historycznych, zagubionych pośród historycznej oraz nowej zabudowy miast. Przykładem takiego odkrycia może być odnalezienie w centrum Opola ponad 200-letniej studni. Nie jest do dziś dokładnie znana historia powstania studni i budynku, w którym się znajduje. W latach sześćdziesiątych XX wieku, przy okazji porządkowania jednej z piwnic nieistniejącego już obiektu pochodzącego z przełomu XVIII i XIX wieku, odnaleziono naczynie ze srebrnymi monetami. Ponad 50 lat później, z inicjatywy pasjonatów historii miasta Opola, podjęto próbę przywrócenia tego unikatowego obiektu do życia, lecz zamierzenie to zrealizowano dopiero na przełomie lat 2018 i 2019. W artykule omówiono proces rewitalizacji pozostałości budowli, w której odnaleziono studnię, zaproponowane rozwiązania o charakterze ratunkowo-naprawczym oraz przebieg prac związanych z oczyszczeniem i nadbudowaniem studni.
EN
At present, there are still situations which favor the discovery of valuable historical objects, lost among the historical and new buildings of the cities. An example of such a discovery can be the finding of an over 200-yearold well in the center of the old town of Opole. The exact history of the well and the building in which it is located is still unknown. In the 1960s, while cleaning one of the cellars of a currently non-existent building, dating from the turn of the eighteenth and nineteenth centuries, a vessel with silver coins was found. More than fifty years later, on the initiative of enthusiasts of the history of the city of Opole, an attempt was made to bring this unique structure back to life, but this intention was realized only at the turn of 2018 and 2019. This paper presents the process of revitalization of the remains of the building in which the well was found, the proposed rescue and repair solutions and the course of works related to the cleaning and vertical extension of the well.
EN
Purpose: The purpose of this work is to consider the complications that arise while operating gas condensate wells, in particular, the accumulation of hydrocarbon condensate, formation and condensation water at wells and flowlines, to develop a method for removing liquid from wells and flowlines before it entering a gas treatment unit and being treated with surfactants and to develop a method for the foam destruction in the gas-liquid flow. Design/methodology/approach: The operational parameters of gas-condensate wells of the Yuliivske oil and gas condensate field (OGCF) have been analysed. Wells have been identified that are operated in difficult conditions due to the accumulation of the liquid at the bottom hole and in flowlines. The volume of the liquid accumulated at the bottom hole of gas condensate wells is estimated. The quantity of surfactants, the volume and concentration of the solution required to remove the liquid were calculated individually for each well. The program of experimental researches has been made. The efficiency of the application of surfactant solution was experimentally determined and a positive result was achieved in the form of an increase in production by 10%. A new approach to the use of surfactant solution, as well as the foam destruction, has been proposed. The studies were performed within the framework of research and development work by the specialists of the Ukrainian Scientific Research Institute of Natural Gases. Findings: Comprehensive measures are proposed to increase the efficiency of gas condensate wells operation. They are monitoring of operational parameters of wells by pressure and temperature gauges installed at the wellhead and at the inlet gas pipelines of the gas treatment unit; calculation of the volume of accumulated fluid in the wellbore and flowline; installation of a complex of automated feeding a surfactant solution of both in the annulus of the wells and in the flowline. For this purpose, two options for the complex and and have a different principle of operation. To prevent foam from entering the gas treatment unit, a method of its destruction has been proposed. The implementation of the proposed comprehensive measures will allow controlling the well operation mode, timely liquid removal from the well and the flowline and ensure stable hydrocarbon production. Research limitations/implications: The obtained results of laboratory and experimental studies have shown that using a surfactant solution is reasonable to remove the liquid from gas condensate wells. To increase the efficiency of the measure, a new method of feeding surfactant solution was developed by installing a unit for automated feeding (UAF) of a surfactant solution at the mouth. Practical implications: The results of laboratory tests allow using a surfactant solution reasonably in order to remove the liquid from gas condensate wells, as well as possible further destruction of foam in the gas-liquid flow for increasing both the efficiency of the extraction and production volume. Originality/value: On the basis of previously performed experimental research, it has been established that it is advisable to use a surfactant solution to remove the liquid from gas condensate wells and flowlines. A new method of removing liquid from gas condensate wells and flowlines has been developed, as well as a method of destroying foam in a gas-liquid flow, which are original and can be implemented.
EN
Purpose: The purposes of this article are to study the effective ways of increasing the hydraulic efficiency of gas gathering pipelines of the Yuliivskyi oil and gas condensate production facility (OGCPF); to calculate the operation efficiency of gas gathering pipelines of the Yuliivskyi OGCPF and develop a set of measures to monitor their condition and improve their hydraulic characteristics; to investigate the technology of cleaning the inner cavity of flowlines of gas-condensate wells with foam, to perform the feasibility study on the prospects of its application in practice. Design/methodology/approach: The technology of cleaning the inner cavity of flowlines of gas-condensate wells with foam was investigated to objectively evaluate its application and determine the effectiveness of this measure. The research was carried out within the framework of research and development work by the specialists of the Ukrainian Scientific Research Institute of Natural Gases. Findings: The results of production studies showed that due to cleaning the flowlines of gas-condensate wells (No.85 and No.60) from the accumulation of liquid, the coefficients of their hydraulic efficiency increased by 12% and 7%, respectively. Measures taken to clean the inner cavity of the flowlines from liquid have proven their efficiency and can be recommended for other flowlines of wells at other production fields. Research limitations/implications: Based on the characteristics of gas gathering pipelines, it is reasonable to conduct experimental studies on the use of the proposed technology of cleaning the inner cavity with foam in the case of increasing its multiplicity. Practical implications: Using the wells of the Yuliivske oil and gas condensate field as case studies, the operating parameters were measured and the pressure losses along the length of the flowlines were calculated. According to the results of calculations at two wells (No.85 and No.60), a significant excess of the actual value of the flow friction characteristic over the theoretical value was established. To reduce excessive pressure losses due to the presence of liquid and improve the hydraulic characteristics of the wells, their inner cavities were cleaned using foam with the expansion ratio from 40 to 100. Originality/value: It is important to note that the advantages of foam piston include: ease of use, no occurrence of hydraulic shocks and preventing stuck during movement in the gas pipeline, application in both straight and inclined sections, no wear of the elements of the cleaning equipment, a rather efficient cleaning of gas pipelines.
PL
Artykuł prezentuje efektywność odbioru wody na ujęciu infiltracyjnym dla Bydgoszczy studniami eksploatowanymi, pompami głębinowymi, lewarami i drenażami zbiorczymi. Opisano przebieg eksploatacji i postęp kolmatacji w zależności od konstrukcji studni z pompami, lewarowych i drenaży zbiorczych. Porównano zużycie energii elektrycznej w tych trzech metodach poboru wody infiltracyjnej. Zasięg kolmatacji rejestrowano inspekcjami TV, pomiarami w pompowaniach strefowych i metodami geofizycznymi. Po 9 latach eksploatacji można stwierdzić, że tak zaprojektowany odbiór wody obniżył koszty eksploatacji w zakresie energii i opłat środowiskowych. Obserwacje procesów kolmatacji na filtrach studziennych i odpowiednio projektowane renowacje pozwalają aktualnie utrzymać wydatek jednostkowy studni na poziomie ok. 100% z okresu budowy.
EN
The paper presents the effectiveness of an artificially recharged well field system in Bydgoszcz, consisting of pump and siphon wells plus drains. The course of exploitation and the progress in clogging, depending on the well construction (pump, siphon, or drain wells), is described. Energy consumption for these three water extraction methods are compared. The clogging range was observed by camera inspections, zone pumping tests, and geophysical methods. After nine years of exploitation, it is possible to assume that the designed system saves the energy consumption and environmental charges. Observations of clogging processes and appropriate well rehabilitations enable to maintain nearly 100% of the new well-specific capacity.
PL
Celem prowadzonych badań była analiza jakości i wartości użytkowej wody w studni kopanej położonej na terenie zagrody wiejskiej w zlewni Jeziora Wydmińskiego. Badania prowadzono w okresie od czerwca 2016 do maja 2018 roku w gospodarstwie rolnym w miejscowości Sucholaski (województwo warmińsko-mazurskie). Jest to studnia kopana o głębokości 3,75 m, która w minionym okresie była używana jako ujęcie wody pitnej, a obecnie jest tylko dodatkowym źródłem wody wykorzystywanej na potrzeby gospodarstwa (podlewanie roślin i pojenie bydła). Przeprowadzone badania wykazały, że w wodzie ujmowanej ze studni występują wysokie stężenia zanieczyszczeń mineralnych, wśród których dominowały, m.in. azotany(V) oraz jony potasu. Złą jakość wody potwierdzają również wskaźniki określające ogólną ilość składników chemicznych zawartych w wodzie, tj. przewodnictwo elektrolityczne właściwe (EC) oraz suma składników rozpuszczonych (TDS). Świadczy to o niewystarczającym zabezpieczeniu studni i przenikaniu zanieczyszczeń do wody z najbliższego jej otoczenia. W przeszłości studnia była źródłem wody pitnej, jednak ze względu na wysokie stężenia zanieczyszczeń chemicznych obecnie woda czerpana z tego ujęcia jest niezalecana do spożycia. Ponadto długotrwałe nawadnianie gleby i roślin analizowaną wodą może pogorszyć warunki glebowe oraz zmniejszyć potencjał plonotwórczy upraw. Wynika to w głównej mierze z bardzo dużych stężeń jonów potasu.
EN
The aim of the research was to analyze the quality and utility value of water in a dug well located in the farmstead in the Wydminskie Lake catchment. The analysis of chemical indicators of water in a backyard well located on the rural area was conducted from June 2016 to May 2018 in a farmstead in Sucholaski (Warmian-Masurian Voivodeship). It is a dug well with a depth of 3.75 m. Once it was used as a drinking water intake, now it is an additional source of water used for the needs of the farm. The research carried out showed in the water drawn from the well there are high concentrations of mineral pollutions, among which dominated, nitrates(V) and potassium ions. Poor water quality is also confirmed by indicators determining the total amount of chemical components contained in water e.g.: electrolytic conductivity (EC) and total dissolved solids (TDS). This indicates insufficient protection of the well and penetration of pollution to water from the environment. In the past, the well was a source of drinking water, however, due to high concentrations of chemical pollution, currently the water drawn from this intake is not recommended for consumption. In addition, long-term irrigation of soil and plants with the analyzed water may worsen soil conditions and decrease crop yield potential. This is mainly due to very high concentrations of potassium ions.
PL
Rozwój gospodarczy miast stawia przed konstruktorami trudne zadania. Jednym z wielu problemów jest posadowienie nowego budynku w zwartej zabudowie. W artykule przedstawiono własne rozwiązanie tego zagadnienia. Zaproponowano podziemny układ konstrukcyjny jako mieszany stalowo-żelbetowy. Wyznacznikiem bezpieczeństwa jest trwałość i niezawodność konstrukcji.
EN
The economic development of cities poses constructors difficult task. The paper presents a new own solution to this problem. The newly designed underground structural system was proposed as a mixed: steel – reinforced concrete. Durability and quality in terms of reliability of the structure, which is a measure of safety is the overarching goal of this publication. In this case, the repairing were made during the design stage.
EN
In spite of the abundance of water resources in the watershed of Khenchela region, the strong urban growth and the expansion of agricultural land resulted in a considerable increase in water needs. This fact exposed groundwater and surface vulnerability to an overlooked growing pollution. In this vein, this study aims to determine the global quality of groundwater oriented to drinking water supply in Khenchela city. It focuses particularly on looking for minerals, nutrients and salt concentration and to assess their spatial and temporal variability. This area has been the subject of several previous studies due to the importance of its watershed (hydrology, geology, geomorphology, bacteriology...). The dosage of the considered parameters revealed vulnerability of water of the North and the North Western part of the watershed to the strong mineralization and excess of organic minerals. This requires in the short term an obligation to treat this water before distribution. A permanent monitoring and the use of other evaluation means for quality protection of this vulnerable resource have been taken into account.
PL
Mimo obfitości zasobów wodnych w zlewni regionu Khenchela, intensywna urbanizacja i powiększanie obszaru gruntów rolniczych znacząco zwiększyło zapotrzebowanie na wodę. Mając to na uwadze, podjęto badania nad jakością wód gruntowych przeznaczonych do zasilania miasta Khenchela w wodę pitną. Skupiono się na stężeniu związków mineralnych, pierwiastków biogennych i soli oraz na ich przestrzennej i czasowej zmienności. Ze względu na znaczenie zlewni obszar badań był przedmiotem kilku wcześniejszych studiów nad hydrologią, geologią, geomorfologią i bakteriologią. Mierzone parametry ujawniły podatność wód północnej i północnozachodniej części zlewni na mineralizację i nadmiar substancji mineralnych. Wymaga to uzdatniania wody przed jej dystrybucją. Rozważono także stały monitoring i inne metody oceny w celu ochrony jakości tych wrażliwych zasobów.
EN
Uranium concentrations in groundwater taken from private drilled wells have been never determined in Poland, implying a lack of available data to quantify the human exposure to U through drinking water consumption, especially in rural areas influenced by mining activities. The main aim of the study was the assessment of human health risk related to the consumption of well waters containing U, collected from selected rural areas of the Lower Silesian region (Poland). The random daytime (RDT) sampling method was applied to the collection of well waters from three control study areas (CSA): Mniszków (CSA-A), Stara Kamienica/M. Kamienica/Kopaniec (CSA-B) and Kletno (CSA-C). The analyses of RDT samples were performed by validated method based on inductively coupled plasma mass spectrometry (ICP-MS). Uranium concentration ranges in well waters and the estimated geometric means for individual control study areas were: 0.005-1.03 μg/L and 0.052 μg/L (CSA-A), 0.027-10.6 μg/L and 0.40 μg/L (CSA-B), and 0.006-27.1 μg/L and 0.38 μg/L (CSA-C). The average and individual chronic daily intakes (CDI) of U by drinking water pathway (adults/children) were in the ranges of: 0.0017-0.013/0.0052-0.040 μg · kg-1 · day-1 and 0.0002-0.90/0.0005-2.71 μg · kg-1 · day-1. The average %TDI and ranges of individual %TDI (adults/children) were: 0.17%/0.52% and 0.02-3.4%/0.05-10.3% (CSA-A), 1.3%/4.0% and 0.09-35%/0.27-106% (CSA-B), and 1.3%/3.8% and 0.02-90%/0.06-271% (CSA-C). The estimated average CDI values of U through well water are significantly lower than the TDI (1 μg · kg-1 · day-1), while for individual CDI values the contribution to the TDI can reach even 90% (adults) and 271% (children), indicating essential human health risk for children consuming well water from private drilled wells located in CSA-B and CSA-C (5.3% of total number of samples collected).
PL
Stężenia uranu w wodach gruntowych pobieranych z prywatnych studni wierconych nie były dotąd badane w Polsce. W związku z tym, brak jest jakichkolwiek danych pozwalających na określenie narażenia ludzi na uran, związanego z konsumpcją wody przeznaczonej do spożycia, w szczególności na obszarach wiejskich, na terenach których prowadzono działalność górniczą. Głównym celem niniejszej pracy była ocena ryzyka zdrowotnego związanego z konsumpcją wód studziennych zawierających uran, pobieranych z wytypowanych obszarów wiejskich Dolnego Śląska (Polska). Do pobierania próbek wód studziennych z trzech obszarów badań kontrolnych (CSA): Mniszków (CSA-A), Stara Kamienica/M. Kamienica/Kopaniec (CSA-B) i Kletno (CSA-C), została zastosowana metoda RDT (ang.: Random DayTime). Analizy próbek RDT przeprowadzono za pomocą zwalidowanej metody opartej na spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS). Zakresy stężeń uranu w wodach studziennych i wyznaczone średnie geometryczne stężenia U w przypadkach poszczególnych obszarów wynosiły: 0,005-1,03 μg/L i 0,052 μg/L (CSA-A), 0,027-10,6 μg/L i 0,40 μg/L (CSA-B) oraz 0,006-27,1 μg/L i 0,38 μg/L (CSA-C). Średnie i indywidualne chroniczne dzienne pobrania (CDI, ang. Chronic Daily Intake) uranu związane z konsumpcją wody przeznaczonej do spożycia (dorośli/dzieci) zawarte były odpowiednio w zakresach: 0,0017-0,013/0,0052-0,040 μg · kg-1 · dzień-1 i 0,0002-0,90/0,0005-2,71 μg · kg-1 · dzień-1. Wyznaczone średnie i zakresy indywidualnych procentowych udziałów wartości CDI w tolerowanym dziennym pobraniu (TDI=1 μg · kg-1 · dzień-1, ang. Tolerable Daily Intake) (dorośli/dzieci) wynosiły: 0,17%/0,52% i 0,02-3,4%/0,05-10,3% (CSA-A), 1,3%/4,0% i 0,09-35%/0,27-106% (CSA-B) oraz 1,3%/3,8% i 0,02-90%/0,06-271% (CSA-C). Wyznaczone średnie wartości CDI uranu są znacząco niższe od ustalonej wartości TDI, podczas gdy w przypadkach indywidualnych wartości CDI ich udział w TDI może osiągać nawet 90% (dorośli) i 271% (dzieci), implikując istotne zagrożenie zdrowia dzieci spożywających wodę z prywatnych studni wierconych na obszarach CSA-B i CSA-C (5,3% całkowitej ilości pobranych próbek).
14
Content available Efektywność studni odwadniających
PL
Systemy przemysłowe zużywają na przepompowanie cieczy ponad 20 % energii elektrycznej produkowanej na świecie. Wykorzystanie potencjału pompowego przy minimalnych nakładach energetycznych wymaga właściwego doboru poszczególnych elementów składowych systemu i dostosowanie parametrów pracy urządzeń do warunków środowiskowych. W przypadku studni ujęciowych i odwadniających oznacza to konieczność wpasowania parametrów systemu pompowo-tłocznego do własności geohydraulicznych ośrodka wodonośnego. W artykule omówiono sposób oznaczania charakterystyk sprawności poszczególnych elementów składających się na system pompowo-tłoczny oraz sposób określania przebiegu charakterystyki sprawności studni. W końcowej części pracy poddano analizie dwa różne przypadki studni odwadniających pełniących odmienne funkcje w systemie odwodnienia kopalni odkrywkowej węgla brunatnego.
EN
To pump liquids, the industrial systems consume more than 20% of electricity produced in the world. Realizing the pumping potential with minimal energy expenditures requires a proper selection of particular components of the system as well as adapting the devices’ parameters to the environmental conditions. In the case of intake and drainage wells this implies a necessity to fit the parameters of the pumping system to the geo-hydraulic properties of the aquifer. This paper describes a method of determining efficiency characteristics of various elements of the pumping system as well as a method for determining the characteristics and efficiency of the well. Two different cases of drainage wells, performing different tasks in the drainage system of an open-pit lignite mine were analyzed in the final part of the study.
PL
W pracy przedstawiono wyniki badań jakości wód podziemnych w studniach głębinowych oraz kopanych w wybranych miejscowościach na terenie gminy Komarówka Podlaska w woj. lubelskim. Obszar ten jest szczególnie narażony na zanieczyszczenia związkami azotu pochodzącymi z działalności bytowej i gospodarczej człowieka, głównie rolniczej. Próbki wody pobierano trzykrotnie w 2013 r. i oznaczono w nich: NO3 , NO2 , NH4 , Cl, SO4 , Fe, Mn, pH, przewodność elektrolityczną oraz bakterie z grupy coli i coli typu kałowego. Z przeprowadzonych badań wynika, że wody ze studni głębinowych są w znacznym stopniu zanieczyszczone głównie żelazem i manganem. Wody ze studni kopanych zawierają ponadnormatywne stężenia manganu i siarczanów. Tylko w dwóch spośród ośmiu badanych studni stwierdzono podwyższoną zawartość azotanów (64 i 119 mg dm-3). Ponadto analizowane wody charakteryzowały się bardzo niską jakością mikrobiologiczną. Wyniki analiz wskazują na zanieczyszczenia wody przez ścieki bytowe. Większość prób wody nie spełniała wymogów Rozporządzenia Ministra Zdrowia z 2007 r. pod względem jakości mikrobiologicznej. Należy niezwłocznie podjąć działania mające na celu poprawę jakości wód użytkowanych przez mieszkańców gminy Komarówka Podlaska.
EN
The paper presents the results of groundwater quality in deep wells and dug in selected villages in the municipality of Komarówka Podlaska in Lublin province. This area is particularly exposed to pollution by nitrogen compounds derived from economic activities and living conditions of people, mostly agricultural.Water samples were collected three times in 2013 and assayed for both: NO3 , NO2 , NH4 , Cl, SO4, Fe, Mn, pH, electrolytic conductivity as well as coli forms and faecal coliforms. The study shows that water from deep wells are heavily contaminated mainly with iron and manganese. Water from dug wells contain oversize concentrations of manganese and sulfates. Only in 2 from 8 researched wells elevated was observed higher concentration of nitrate (64 and 119 mg dm-3). In addition, the water is characterized by a very low microbiological quality. The results of analysis indicate show that water is polluted by domestic waste water. Most of the water samples did not meet the requirements of the Regulation of the Minister of Health in 2007 in terms of microbiological quality. You should immediately take action to improve the quality of water used by the residents of the municipality Komarówka Podlaska.
16
PL
W artykule opisano realizację projektu wykonania 10 głębokich otworów studziennych na przedpolu Szczerców dla KWB Bełchatów. W sierpniu 2011 r. spółka PNiG Kraków, specjalizująca się w wierceniach naftowych, przystąpiła do realizacji projektu. Zastosowano nową technologię wiercenia studni odwodnieniowych. Po raz pierwszy w Polsce wykorzystano technologię przerabiania i wiercenia rurami okładzinowymi – tzw. casing drilling. Prace wykonywano w trudnych warunkach geologicznych i technicznych.
PL
W artykule przedstawiono rozwiązanie ustalonego dopływu wody do studni niezupełnej, wykonanej w jednorodnej i ortotropowej warstwie o swobodnym zwierciadle wody. W obliczeniach uwzględniono swobodną powierzchnię wypływu w studni i możliwość piętrzenia wody przez rurę nadfiltrową. Warstwa wodonośna ma poziomo wykształcony spąg i może być zasilana wodami infiltracyjnymi. Rozwiązanie wykonano w formie programu w arkuszu kalkulacyjnym Excel przy wykorzystaniu metody różnic skończonych. Bazuje ono na równaniu przepływu wód podziemnych Laplace’a w układzie współrzędnych logarytmiczno-walcowym. Program umożliwia obliczanie dopływu wody do studni, zeskoku hydraulicznego, zasięgu leja depresji oraz generuje wykresy położenia zwierciadła wody w funkcji odległości od studni. Wstępne testy wskazują na zgodność wyników uzyskiwanych za pomocą omawianego programu z niektórymi wynikami opisywanymi w literaturze. Program jest udostępniany nieodpłatnie na stronie internetowej www.ig.pwr.wroc.pl/zaklady/ZGiWM pod nazwą studnia_zw_swob.xls.
EN
The article presents a solution for steady-state water in flow to an incomplete well located in a homogeneous and orthotropic unconfined water table aquifer. The calculations take account of the surface of seepage in the well and a possibility of lifting water with a well-casing pipe. The aquifer has a horizontal bottom and can be recharged with in filtration waters. The solution was produced in the form of a programme written in Excel spreadsheet with a use of the finite difference method. It is based on Laplace groundwater flow equation in the logarithmic-cylindrical coordinate system. The program enables the calculation of water in flow to a well, the height of seepage face, the size of the depression cone, and it generates graphs of water table position as a function of distance from the well. The preliminary tests demonstrate the consistence of the results obtained by means of the discussed programme with results described in literature. The programme is available free of charge from the website www.ig.pwr.wroc.pl/zaklady/ZGiWM at studnia_zw_swob.xls.
18
Content available remote Studnie fundamentowe. Część 3. Zapełnianie i przeszkody
PL
Zapełnianie studni z wodą przy braku specjalistycznego sprzętu było kłopotliwe. Zwykle betonowano pod wodą część studni, a resztę na sucho po wypompowaniu wody. Problemy pojawiały się przy przeszkodach takich jak głazy i pnie drzew. Pompowanie wody ułatwiało wydobywanie gruntu, ale powodowało napływ gruntu z zewnątrz.
EN
Filling up the wells, without special equipment, was problematic. Usually, part of the well was concreting under water and the remaining part in dry after water pumping out. The problems appeared at obstacles such as stones and timber trunks. Water pumping facilitated soil excavation but it caused flow in external soil.
19
Content available remote Studnie fundamentowe. Część 2. Opisy wykonania
PL
Wykonywanie studni fundamentowych przy braku mechanizacji wymagało dużo wysiłku i czasu. Do wydobywania gruntu, najczęściej z wody, stosowano koszyki skórzane, łopaty indyjskie, świdry, bagrownice łańcuchowe i kubłowe. Problemy pojawiały się przy przeszkodach, takich jak głazy i pnie drzew. Pompowanie wody ułatwiało wydobywanie gruntu, ale powodowało napływ gruntu z zewnątrz. Niekiedy wykonywanie studni trwało 2 lata.
EN
Construction of foundation wells in time with lack of mechanization were effort an time consuming. Leather baskets, Indian shovels, drills, chain and bucket dregers were used for soil excavation. The problems appeared at obstacles such as stones and timber trunks. Water pumping facilitated soil excavation but it caused flow in external soil. Sometimes, the well were constructed even two ears.
20
Content available remote Studnie fundamentowe. Część 1. Opisy rozwiązań
PL
Studnie budowano od dawna jako sposób głębokiego fundamentowania mostów. Studnia zagłębia się zwykle pod swoim ciężarem podczas stopniowego wybierania gruntu wewnątrz studni. Budowano studnie drewniane, drewniano-betonowe (dwa płaszcze drewniane wypełniane betonem), betonowe, żelbetowe, żeliwne, a potem stalowe i stalowo-betonowe.
EN
Wells have been constructed since a long time as the way of deep bridge foundation. Usually, well immerse into soil under its weight during progressive soil excavation inside the well. Various types of well have been constructed, such as timber, timber-concrete (two timber tubes with concrete between), concrete, iron, steel and steel-concrete wells.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.