Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 23

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  steam generator
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available remote Modelling and an adaptive fuzzy logic controller of solar thermal power plant
EN
This article aims to model and control a solar thermal power plant. The modeling and the dynamic behavior of the system have been well studied and carried out the variation of the exchanger temperature by acting on different parameters, such as the length, the exchange surface, and the exchange coefficient. A comparison was made between conventional PI control and an advanced AFLC-PI fuzzy logic-based control to drive the steam turbine. This advanced command improves the system's robustness with respect to internal disturbances (parametric variations) and external disturbances (sudden pressure variations).
PL
Celem artykułu jest modelowanie i sterowanie elektrownią słoneczną. Modelowanie i dynamiczne zachowanie systemu zostały dobrze zbadane i przeprowadzono zmianę temperatury wymiennika poprzez oddziaływanie na różne parametry, takie jak długość, powierzchnia wymiany i współczynnik wymiany. Dokonano porównania między konwencjonalnym sterowaniem PI a zaawansowanym sterowaniem opartym na logice rozmytej AFLC-PI do napędzania turbiny parowej. To zaawansowane polecenie poprawia odporność systemu na zakłócenia wewnętrzne (zmiany parametryczne) i zewnętrzne (nagłe zmiany ciśnienia).
EN
The article presents a model of a steam generator based on mass and energy balance equations, heat transfer coefficients, criterion relations and Peclet’s law. The presented model was applied to a steam generator without and with an economizer for a PWR/EPR nuclear power plant. Based on the calculations, the steam pressure at the outlet of the steam generator without the economizer is 74.17 bar, and for the model with the economizer it is 77.2 bar. The pressure difference for these two variants, based on the calculations, was therefore 3 bar. Higher steam pressure at the outlet of the steam generator translates into a greater enthalpy drop in the turbine and greater power generated by the steam turbine and the efficiency of the entire nuclear power plant. Based on the economic calculations carried out for 60 years of operation of a nuclear power plant with four steam generators, the profit from the use of the economizer amounted to about PLN 0.6 billion.
3
Content available remote Metody generacji kontrolowanych stężeń par sarinu
PL
Przedstawiono metody generowania par sarinu, które opracowano i przebadano w Wojskowym Instytucie Chemii i Radiometrii (WIChiR). Porównano trzy metody generacji par sarinu: z zastosowaniem kapilary, metalowego naczynia generacyjnego oraz z wykorzystaniem roztworów sarinu w odpowiednich rozpuszczalnikach alifatycznych. Stężenia próbek gazowych były analizowane z wykorzystaniem GC-FPD. Dokonano analizy każdej z metod pod kątem stabilności generacji par sarinu.
EN
Three potentially stable methods of generating sarin vapour were compared using (i) a capillary, (ii) solns. of sarin in suitable aliphatic solvents and (iii) a metal vessel and liquid sarin. The gas sample concns. were analyzed using the GC-FPD. The best results were obtained for the method (iii), which showed high repeatability and stability of the generated sarin concn. over time and was characterized by increased work safety.
EN
The presented work investigates a method for developing hard-to-recover hydrocarbon reserves based on a downhole electrothermal steam generator, which is distinguished by energy efficiency, resource conservation and environmental safety. The paper presents an overview of downhole electro-thermal equipment that improves the quality of thermal treatment of the bottom-hole zone of high-viscous oil formations by separating steam in an electric steam generator and increasing its dryness, wherein thermal energy in the oil-formation medium affects all its components and completely changes ties and filtration conditions. This is expressed in a decrease in the viscosity of oil, its increased mobility, weakening of structural-mechanical properties, improvement of the conditions for capillary imbibition, and, as a result, an increase in the displacement factor and the final oil recovery. A simulation of the reservoir temperature field was performed by setting the heat flow in the ANSYS software package to understand the thermal processes in the steam generator and to more accurately determine the necessary heating parameters for a given water flow rate. The temperature field of the reservoir simulation after the heat treatment of the bottom-hole zone was conducted in the software package Femlab 3.5. The proposed simulation models can help in the development of the physical model and further research. This technology is environmentally friendly and does not emit emissions into the atmosphere.
PL
Zastosowanie nowoczesnych, wielokanałowych systemów chemicznego i fotochemicznego generowania par umożliwia selektywne wydzielanie wielu pierwiastków z próbki analitycznej i efektywne ich wprowadzanie, wraz z aerozolem, do źródeł atomizacji/wzbudzenia/jonizacji.
EN
Introduced through policy instruments, as well as due to increase awareness of and demand for energy, alternative, renewable energy sources are becoming increasingly popular and necessary. The growing market and standards are forcing producers of renewable energy sources to constantly improve the quality of their products. Biomass trigenerators are one way of obtaining such energy, both in the form of electricity, heat and cold. These are elements generating steam by burning various solid, liquid or gaseous fuels of organic origin. Rotating machines in the form of turbines or steam engines are used to generate electricity. Unfortunately, they are particularly exposed to steam impacts associated with discontinuous work. This article presents the monitoring and prevention system for such impacts. It is based on the analysis of the frequency spectrum of vibrations of such generators and can be used to implement a trigenerator control system that will reduce the influence of such impacts. With proposed diagnostic system, the efficiency and life span of a Renewable Energy Source can increase significantly.
PL
Proces suszenia bibułki tissue w maszynach z osłonami gazowymi wiąże się z koniecznością skutecznego odzyskiwania ciepła z wilgotnych spalin usuwanych do atmosfery. Ponieważ temperatura usuwanych spalin często przekracza 300°C, warto wykorzystać tak wysoką temperaturę do wytworzenia pary w pierwszym stopniu rekuperacji ciepła. Aby było możliwe wytwarzanie pary o ciśnieniu pozwalającym na użycie jej do ogrzewania cylindra Yankee, temperatura usuwanych spalin powinna być co najmniej o kilkadziesiąt stopni wyższa od temperatury nasycenia pary wprowadzanej do cylindra Yankee. Jest to podstawowy warunek opłacalności zabudowy wytwornicy pary.
EN
Tissue drying process in machines with gas fired hoods is connected with the necessity of effective heat recovery from moist flue gas discarded to atmosphere. Since the temperature of discarded flue gas often exceeds 300ºC it is worth to make use of such high temperature for steam generation on the first stage of heat recovery. In order to generate steam of pressure enabling its use to Yankee cylinder heating, the temperature of discarded flue gas should be at least several dozen higher than the saturation temperature of steam entering Yankee cylinder. It is the prerequisite of profitable steam generator installation.
8
Content available remote A novel concept of H2/O2 steam generator
EN
This paper presents an idea of hydrogen utilization to steam generation to drive a turbine and produce electricity or to supply a condenser as an element of a heating system. Electrolysis process is considered as a source of hydrogen as well as oxygen. Hydrogen combustion with a stoichiometric ratio of pure oxygen produces steam at very high temperature. Steam temperature can be controlled by mixing the generated steam with liquid water injected into the steam generator. The details of the prototype H2/O2 steam generator are presented. The concept of the test stand – consisting of the electrolysis unit, H2/O2 steam generator and steam condenser, is described.
PL
Wobec faktu wyczerpywania się zasobów kopalnych nośników energii oraz dążenia do minimalizacji emisji CO2 (gospodarka zeroemisyjna), koniecznym staje się opracowanie koncepcji oraz konstrukcji technicznych, bazujących na OZE oraz innych, niekonwencjonalnych nośnikach energii. Perspektywicznym substytutem konwencjonalnych paliw kopalnych jest wodór, coraz powszechniej stosowany w energetyce oraz w układach typu Power2Gas. Znane są rozwiązania techniczne wykorzystania wodoru w ogniwach paliwowych, których przeznaczeniem jest generowanie energii elektrycznej. Innymi, znanymi rozwiązaniami są: wykorzystywanie wodoru do współspalania paliw konwencjonalnych w silnikach spalinowych czy palnikach przeznaczonych dla paliw płynnych, przegrzewaczach pary wodnej czy w parowych obiegach turbinowych. Wodór może być wytwarzany przy użyciu wielu technologii. Metodą perspektywiczną wydaje się proces elektrolizy wody, w którym źródłem energii elektrycznej są OZE. W koncepcji Power2Gas wytwarzanie wodoru na drodze elektrolizy jest szczególnie atrakcyjne ze względu na fluktuacje zapotrzebowania na energię elektryczną. W przypadku braku zapotrzebowania na energię elektryczną wytwarzaną przez turbiny wiatrowe czy systemy fotowoltaiczne nie zachodzi konieczność wyłączania tych układów z sieci, tylko przekierowanie wytwarzanej energii do zasilania elektrolizerów. Wytworzone w wyniku elektrolizy wodór oraz tlen mogą zostać zmagazynowane w zbiornikach ciśnieniowych i zużywane według potrzeb zdefiniowanych przez konstrukcję odbiorników sieci Power2Gas, np. silniki wewnętrznego spalania czy przegrzewacze pary. Prototypowa, wodorowa wytwornica pary składa się z elektrolizera oraz właściwej wytwornicy pary. Elektrolizer ma na celu symulację sieci Power2Gas, zaś wytwornica pary służy do produkcji pary w wyniku spalania mieszaniny wodoru i tlenu. Wodorowa wytwornica pary jest więc węzłem cieplnym, do którego podłączone są odbiorniki ciepła w celu jego utylizacji. Ponieważ w prototypowej instalacji zastosowano elektrolizer bezprzeponowy, do wytwornicy pary doprowadzana jest mieszanina wodoru oraz tlenu i nie ma potrzeby stosowania dodatkowego utleniacza, np. w postaci powietrza atmosferycznego. Tak więc jedynym produktem spalania jest para wodna, która wraz z wtryskiwaną do wytwornicy pary mgłą wodną krąży w zamkniętym obiegu pierwotnym wytwornicy pary przez wymiennik ciepła, zawór odwadniający, zbiornik kondensatu oraz pompę wody, dostarczającą wodę ze zbiornika kondensatu do dysz mgłowych, zainstalowanych w wytwornicy pary. Takie rozwiązanie techniczne wyklucza więc emisję CO2, NOx, SOx. Wytwarzanie pary wodnej jako nośnika ciepła odbywa się dzięki wtryskowi mgły wodnej do komory spalania wodoru oraz tlenu. Strumienie wytworzonej pary wodnej z mgły wodnej oraz pary powstałej wskutek spalania mieszaniny wodorowotlenowej, mieszają się ze sobą i razem stanowią nośnik ciepła, który jest dostarczany do wymiennika ciepła. Stopień suchości wytwarzanej pary wodnej jest zależny od temperatury spalania mieszaniny wodorowo-tlenowej oraz od strumienia masowego dostarczanej wody przez dysze mgłowe do wytwornicy pary. Regulacja strumienia masy wody odbywa się przez załączanie (lub wyłączanie) z pracy poszczególnych dysz mgłowych oraz zmianę ciśnienia wody na rozdzielaczu doprowadzającym wodę do dysz mgłowych.
PL
Tramwaje do dziś stanowią najpowszechniejszy środek komunikacji miejskiej. Jednym z miast w Polsce, szczycących się najdłuższym funkcjonowaniem tramwajów elektrycznych jest Elbląg, gdzie stałe kursowanie rozpoczęło się w 1895 r. Było to wówczas miasto o olbrzymiej dynamice rozwoju przemysłu. Pierwsze linie komunikacyjne zabezpieczały dowóz robotników do zakładów, łączyły stację kolei żelaznej z przystanią statków, wiodły także do podmiejskich terenów rekreacyjnych. Dla zabezpieczenia sieci tramwajowej w prąd wybudowano pierwszą w mieście elektrownię, zlokalizowaną w centrum Elbląga. Firmie tramwajowej zezwolono też na sprzedaż prądu przedsiębiorstwom i odbiorcom indywidualnym, oświetlenie ulic i placów miejskich. Gwałtowny przypływ odbiorców prądu spowodował w początku lat 20. XX w. przejęcie przedsiębiorstwa przez samorząd oraz budowę nowej, znacznie większej elektrowni miejskiej.
EN
Electrical trams are, until today, the most common transport mode in middle and large cities. Due to the specific production of electricity, which generates not so high cost per one carriage, it have gained a general acceptance over a hundred years ago. One of cities in Poland with the longest functioning of electric trams is Elblag, where regular shuttle began in 1895. Back then, Elblag was the city with enormous dynamics of industrial development, the headquarter of region’s biggest shipbuilding and engineering company and numbers of other factories. First lines of trams in Elblag covered the transport of workers to factories, connected the railway station with harbor and also soon led their way to suburban recreational areas. In order to cover the infrastructure, the city has built the first power station, that was located in the center of Elblag. It was equipped in the steam engines which were locally produced by Schichau concern and electrical parts produced by initial executor of concession for carriage - Berliner company UEG. Soon the tramway’s company were also allowed to sell power to smaller companies and individuals, so well as lightning the streets and city squares. Although the profitability of passenger services was not large and due to the war, revolution and poverty also became problematical, the sudden burst of other power recipients reversed the role of power and in concequence led to takeover the tramway company by local authorities in 1920 and the construction of brand-new and larger munticipial power plant.
EN
Since the development of the first oil fields on the Norwegian Continental Shelf, the petroleum industry in Norway has been making continuous progress in oil production engineering. With greater environmental awareness and increasing taxation of NOx and CO2 emissions, the economic pressure has been rising in recent decades. The energy demand for o shore oil and gas production is high. With a view to improving power generation on offshore oil and gas installations, four models of dierent power cycles were investigated: a simple cycle gas turbine (currently the default option), a compact combined cycle with enhanced fuel utilization, a steam injection gas turbine cycle as an innovative solution, and a state of the art combined cycle for onshore applications as a reference cycle. Special requirements for o shore installations are discussed and sizing was identified as the major criterion. The power demand of an oil platform and its change during dierent states in field life were analyzed. To complete the simulations, the models were set to off-design conditions and the part-load behavior was investigated. The plant layouts were laid out and visualized with 3D CAD models.
EN
The prediction of radiation doses obtained during dismantling of steam generator represents one of the most crucial issues within the process of decommissioning of nuclear installations. Given the fact that in Slovakia the nuclear power plant VI in Jaslovské Bohunice is currently being decommissioned, represents the analysis of the segmentation of steam generator an actual issue. In this paper, the proposed dismantling methodology together with the results of calculations is given. Also the complex analysis of the influence of different distance of workers carrying out the dismantling as well as the influence of the time on the total collective effective dose is carried out. The results of this analysis show that the obtained doses are below the legislative limits and thus the main consequences can be applied in the process of VI nuclear power plant decommissioning.
PL
Przewidywanie dawek promieniowania na które narażona jest obsługa w trakcie demontażu generatora pary reprezentuje jedną z najbardziej kluczowych problemów w ramach procesu likwidacji obiektów jądrowych. Mając na względzie fakt, że na Słowacji elektrownia jądrowa VI w Jaslovské Bohunice jest obecnie wycofywana z ruchu, analiza segmentacji generatora pary stanowi aktualny problem. W pracy zaproponowano metodologię demontażu i podano rezultaty obliczeń. Także złożona analiza wpływu różnych odległości pracowników przeprowadzających demontaż jak również wpływ czasu na całkowitą efektywną zespołową dawkę promieniowania jest przeprowadzony. Wyniki tej analizy pokazują że przyjęte dawki są poniżej limitów wyznaczonych normami i zatem główne konsekwencje mogą być stosowane w procesie demontażu jądrowej elektrowni VI.
EN
A steam generator in a nuclear power plant with a light water reactor is a heat exchanger, in which the heat is being transferred from the primary to the secondary loop (it links the primary and secondary loops). When the power plant is running, the inlet parameters (temperatures and mass flow rates) on both sides of the steam generator can change. It is important to know how the changes of these parameters affect the steam generator performance. The complexity of the processes taking place in the steam generator makes it difficult to create a simulator reflecting its performance under changed conditions. In order to simplify the task, the steam generator was considered as a ‘black box’ with the aim of examining how the changes of the inlet parameters affect the changes of the outlet ones. On the basis of the system (steam generator) response, a simple mathematical model of the steam generator under variable load conditions was proposed. In the proposed model, there are two dimensionless parameters and three constant coefficients. A linear relation between these dimensionless parameters was obtained. The correctness of the model was verified against the data obtained with a steam generator simulator for European Pressured Reactor and AP-600 reactors. A good agreement between the proposed model and the simulator data was achieved.
PL
W ramach projektu Lider realizowanego na Politechnice Lubelskiej została opracowana konstrukcja generatora pary wodnej oparta o wtryskiwacz wody. Przedmiotowy generator pary będzie wykorzystywany w badaniach do zasilania elektrolizera w parę wodną o określonych parametrach (temperaturze i ciśnieniu). Użyte środowisko projektowania bryłowego 3D Catia v5 R20 posiada możliwość generowania dokumentacji w formatach akceptowalnych przez programy służące do dynamicznych obliczeń przepływowych CFD. Objętość modelu komory parowej została poddana przestrzennej dyskretyzacji na elementy skończone. Kształt komory parowej elektrolizera został zoptymalizowany pod względem wielkości i kształtu (przede wszystkim gorącego denka) w celu generowania homogenicznego (w wyniku dobrego mieszania) strumienia pary wodnej. Możliwość zapewnienia stabilnego w czasie przepływu pary jest kluczowa w zapewnianiu optymalnych warunków pracy wysokotemperaturowego elektrolizera HTPEM (ang. High Temperature Proton Exchange Membrane) oraz rzutuje w znacznym stopniu na utrzymanie jego sprawności na odpowiednim poziomie.
EN
The purpose of this paper is to verify the construction assumptions for the regulator of water vapor flow in dynamic and static water vapor flow. The software owned to calculate compressible flow (CFD) - AVL FIRE enables completing this task, namely to develop geometric and mathematical models, and to do simulation calculation. The main problem to be solved is to determine the design parameters of water vapor flow which ensure the required dosing precision.The calculations allow for the verification of the construction assumptions for the control system.
EN
Article presents design and construction considerations on supercritical (once-through) steam generator using high and very high temperature reactor cores as heat source. Helical-coil steam generators are preferred over other types of design thanks to their increased heat transfer rate and compactness. Applicable modernised Rankine cycle and changes in thermophysical parameters of water in the neighbourhood of critical and pseudocritical points are examined. Correlations determining heat transfer coefficient are analysed in order to select the most applicable among them. Critical design aspects of such a supercritical nuclear steam supply system are discussed.
PL
Omówiono wybrane zagadnienia konstrukcji i projektowania przepływowych wytwornic pary współpracujących z rektorami wysoko i bardzo wysoko temperaturowymi. Wytwornice pary o powierzchni wymiany ciepła w formie koncentrycznych spiral wielozwojowych są preferowanym typem dzięki intensyfikacji wymiany ciepła, której towarzyszy redukcja wymiarów zewnętrznych. Przedstawiony został stosowny obieg Rankine’a oraz przeanalizowane zmiany parametrów termofizycznych wody w otoczeniu punktu krytycznego i pseudokrytycznych. Artykuł zawiera analizę i uzasadnienie doboru korelacji określających intensywność procesu przejmowania ciepła przez wodę w stanie nadkrytycznym oraz stosowne poprawki umożliwiające stosowanie jej w przypadku omawianego typu konstrukcyjnego wytwornicy pary.
PL
Celem artykułu jest analiza możliwości wykorzystania wysokotemperaturowego ogniwa paliwowego typu PEM (HTPEM) w trybie pracy elektrolizera. W artykule zaprezentowano także stan wiedzy w dziedzinie elektrolizerów oraz ogniw paliwowych.
EN
This article aims to analyze the possibility of using high-temperature PEM fuel cells (HTPEM) in cell mode. The article contains a description of the current state of knowledge in both fields of electrolyzers and fuel cells.
17
Content available remote Mechanizm uszkodzenia połączeń gwintowych kolektorów wytwornicy pary
EN
Examination results and their interpretation is presented for the explanation of the mechanism of cracks occurring in the threaded holes and bolts of the cover - flange connections of the nuclear power plant steam generator collector. The factors that initiate the failures have been established, while considering the influence of both the components of water penetrating from the primary circulation to the secondary circulation, as well as the grease used in bolt - flange threaded connections during assembly.
PL
W artykule przedstawiono model układu gazowo parowego zintegrowanego ze zgazowaniem biomasy. Przedstawiono dwa modele generatorów gazu wykorzystujących reaktory równowagowe. Model układu gazowo parowego zbudowano z prostej turbiny gazowej oraz układu parowego, zbudowanego z turbiny parowej kondensacyjnej oraz jednociśnieniowego kotła odzyskowego. Wyznaczono podstawowe parametry układu między innymi sprawności oraz moce poszczególnych modułów układu. Analizę parametrów przeprowadzono dla różnych konfiguracji wymienników ciepła oraz dla różnych wartości ciśnienia w kotle odzyskowym.
EN
The paper displays computer model of biomass integrated gasification combined cycle. Two models of gas generator reactors were presented. The models are made up of equilibrium reactors. For this models a gas composition was determined and compared to empirical data. Combined cycle consist of simple gas turbine and steam cycle composed of condensing steam turbine and 1-pressure heat recovery steam generator. The main parameters of the system such as energy efficiency and power were determined. Analysis were carry out for different configurations of heat exchangers and for different values of steam pressure in stem generator.
PL
Wykorzystanie surowców odnawialnych jako paliw w wytwarzaniu energii elektrycznej w przemyśle jest korzystny zawsze wtedy, jeżeli w odnośnej technologii przemysłowej surowce odnawialne są już wykorzystywane. Praktykowane jest to od dłuższego czasu szczególnie w branży przemysłu papierniczego, przetwórstwa drzewnego oraz w przemyśle cukrowniczym. W zaplanowanej i wykonanej przez firmę Siemens elektrowni na biomasę Monopoli (południowe Włochy) wykorzystywane są oprócz zrębków drewnianych również pozostałości z przetwarzania oliwek. Elektrownia będzie dostarczać moc elektryczną na zaciskach ok. 11,3 MW. Elektrownia jest zrealizowana zgodnie z koncepcją konstrukcji modułowej SiecoLine BioPower i została wykonana w formule "pod klucz" przez firmę Siemens. W chwili przygotowywania niniejszego opracowania system znajduje się w końcowej fazie uruchamiania.
PL
Omówiono teoretyczne zależności dotyczące cyrkulacji czynnika roboczego w parowniku jako kryterium bezpiecznej pracy części ciśnieniowej kotła. Przedstawiono przeprowadzone badania wybranego kotła - metodykę pomiarową, wyniki, wnioski i zalecenia. Na tym tle rozważono czynniki wpływające na poziom minimum technicznego, związane z konstrukcją, sposobem eksploatacji i stanem technicznym kotła.
EN
Theoretical relations concerning the circulation of the working medium in the steam generator as a criterion of safe operation of the pressurised boiler part are discussed. Presented are investigations of chosen boiler - measurement methodology, results, conclusions and recommendations. At this background are deliberated factors, connected with design, way of operation and technical state of the boiler, influencing the level of the technical minimum.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.