The analysis of eyes movements is a crucial part of eyes examination performed by clinicians. One of the characteristic type of eyes movements is a saccade. Its accurate detection is the base for further processing including the estimation of saccade parameters such as velocity, amplitude and duration. This paper presents averaging of optokinetic nystagmus (OKN) cycles that allows comparing and detecting different types of nystagmus phenomena. In order to average the OKN cycles the ENG signal needs to be processed. The saccade detection function is used to find the location of saccades in OKN waveform allowing the ENG signal to be divided into cycles. The resulting cycles are aligned using the Fourier shift method and then averaged providing the OKN cycle model, which can be used for evaluating the eyes at different movement conditions.
3
Content available Uśrednianie sygnałów
PL
W artykule przedstawiono przykłady autonomicznych wirtualnych układów do prezentacji wybranych metod uśredniania sygnałów w dziedzinie czasu i częstotliwości. Układy są realizowane przy wykorzystaniu zintegrowanego graficznego środowiska programowania systemów pomiarowych DASYLab i stosowane w dydaktyce podstaw cyfrowego przetwarzania sygnałów.
EN
This article presents some examples of virtual instruments (VI) for presentation selected methods of signal averaging in time and frequency domain. The instruments are based on the graphical programming environment DASYLab and are used in didactics of digital signal processing.
EN
One of the methods applied to detect pinion or gear wheel damage is an analysis of a signal synchronously averaged by the rotation period of a pinion shaft or gear shaft, respectively. For technical reasons, it is often impossible to record the reference signal directly connected with the diagnosed wheel in industrial conditions. The signal is then connected with a rotating element available outside the gear. As a result of torsional vibration in a system of shafts or gear casing vibration in a place where the shaft's angular position sensor is fixed, or in consequence of a too slowly rising reference signal edge, a synchronizing impulse occurs at wheel's angular positions varying by an insignificant value. This paper presents the usefulness of time-delay estimation methods in the process of vibration signals' synchronous averaging.
PL
Jednym ze sposobów wykrywania uszkodzeń zębnika lub koła jest analiza sygnału uśrednionego synchronicznie odpowiednio okresem obrotu wału zębnika lub koła. W warunkach przemysłowych ze względów technicznych często nie jest możliwe rejestrowanie sygnału odniesienia związanego bezpośrednio z diagnozowanym kołem. Wtedy sygnał ten wiąże się z dostępnym na zewnątrz przekładni elementem wirującym. Na skutek drgań skrętnych w układzie wałów, drgań korpusu przekładni w miejscu mocowania czujnika położenia kątowego wału i często zbyt wolno narastającego zbocza sygnału referencyjnego impuls synchronizujący występuje przy położeniach kątowych koła różniących się o niewielką wartość. W niniejszym artykule przedstawiono przydatność metod estymacji przesunięcia czasowego w procesie uśredniania synchronicznego sygnałów drganiowych.
EN
Left ventricular hypertrophy (LVH) in course of the systemic hypertension is found as independent risk factor for arrhythmias and sudden cardiac death. The aim of our study was to evaluate signal averaged ECG of the P-wave (SAP ECG) as a tool to measure the atrial electrical instability in hypertensive patients (pts) with concentric LVH. Study group included 39 pts with mild to moderate primary hypertension. Patients were divided into two group: with concentric LVH and without LVH; LVH was diagnosed by echocardiography (ECHO). By ECHO there were additionally measured the internal end-diastolic diameters and areas of left and right atria (LA, RA, LAar, RAar). From SAP ECG the P duration (hfP), the root-mean-square of the last 20 msec of the averaged and filtered atrial signal (RMS2o) were calculated. By the 12-lead ECG the P duration (Pd) was calculated. Supraventricular arrhythmias were recorded during 24-hour ambulatory ECG monitoring. Results: Duration of hfP was significantly longer in pts with than without LVH (121.8+/-13.0 vs 112.8+/-8.4 msec; p < 0.02). RMS20 was similar in both groups. Pd from standard ECG was increased (114+/-13 vs 107+/-7 msec; p < 0.05) in pts with than without LVH. Supraventricular arrhythmia occurred more frequent in pts with LVH. Conclusion: SAP ECG in hypertensive pts with concentric LVH may be a good tool to evaluate atrial electrical instability.
PL
Celem badań była ocena możliwości wykorzystania uśrednionego EKG załamka P dla pomiaru przedsionkowej niestabilności elektrycznej u chorych z nadciśnieniem i przerostem lewej komory. Przebadano 39 chorych z nadciśnieniem, których podzielono na dwie grupy: z przerostem lewej komory i bez przerostu. Na podstawie uśrednionego i filtrowanego przedsionkowego sygnału EKG obliczono długość załamka P oraz wartość skuteczną(RMS2o) sygnału w końcowych 20 ms. Dla porównania długość załamka P wyznaczono również z 12-kanałowego standardowego EKG. Stwierdzono znamiennie (p < 0,02) większą długość załamka P u chorych z przerostem lewej komory (121,8+/-13,0 ms) w stosunku do chorych bez przerostu (112,8+/-8,4 ms). Wartość skuteczna RMS2o była w obu grupach zbliżona. Długość załamka P wyznaczona z 12-odprowadzeniowego EKG była również znamiennie (p < 0,05) dłuższa u chorych z przerostem (114+/-13 ms) w porównaniu z chorymi bez przerostu (107+/-7 ms). Wyniki badań potwierdzają możliwość wykorzystania uśrednionego sygnału EKG załamka P do oceny przedsionkowej niestabilności elektrycznej.
6
Content available remote Signal averaging and variability estimation in high resolution ECG
EN
The ECG signal digitised with a high resolution level (HR ECG) is a non invasive way more and more used in clinical centres to analyze heart electrical activity. The Signal Averaging technique is commonly used to eliminate the noisy part of the recordings. A synthesis of some of our published works is presented with the aim to take into account both the repetitivity and the variability of cardiac signals coming from HR ECG. Signal averaging is analysed specially when the ideal case of equal shape and equal width signals cannot be assumed. The measure of shape or shape and width differences is applied both to the natural variability to improve averaging and to variations induced by external agents such as the action of a drug.
PL
Elektrokardiografia o wysokiej rozdzielczości (HR-EKG) jest coraz bardziej popularną nieinwazyjną metodą analizy elektrycznej czynności serca w wielu ośrodkach klinicznych. Technika uśredniania sygnałów jest powszechnie stosowana do eliminacji składowej szumu w zarejestrowanych sygnałach. W pracy przedstawiono syntezę kilku wybranych opublikowanych wcześniej prac, które uwzględniały aspekty powtarzalności jak i zmienności sygnałów elektrokardiograficznych rejestrowanych techniką o wysokiej rozdzielczości. Uśrednianie sygnałów jest analizowane głównie w przypadku gdy nie można założyć równości kształtu i szerokości cykli sygnału. Wskaźnik różnic kształtu lub kształtu i szerokości został zastosowany zarówno w przypadku naturalnej zmienności w celu poprawy uśredniania oraz dla zmian wywołanych środkami zewnętrznymi takimi jak działanie leków.