Topical matter of power supply for today is effective increase in the reliability of power supply in medium voltage overhead power systems by sectioning of lines with switching devices, such as disconnectors, controlled disconnectors or sectioning points. In such schemes, the manual approach to emergency management is used. This kind of schemes can be used where the overhead power lines are. Protective device on the outgoing feeder is switched off as soon as damage occurs in any area. As a result, all consumers of the line lose power for a long time. Remotely operated disconnectors or remote controlled sectioning points can also be installed instead of manual line disconnectors. This process of damage localization differs only in that all switching operations are performed remotely. Decision on switching is made by the dispatcher, constant communication with each controlled element of the network is necessary, otherwise it becomes virtually uncontrollable and the entire effect of remote control of disconnectors is eliminated.
PL
W artykule omówiono nowe oraz niedoceniane, rzadko używane funkcje reklozera KTR 27 (Rec25_Al1) firmy Tavrida Electric. Szerzej przedstawiono nowe funkcje oraz ciekawe aplikacje, poprawiające ciągłość zasilania odbiorców.
EN
The article describes new and underrated, rarely used functions of Tavrida Electric KTR27 (Rec25_Al1) recloser. New features and interesting applications improving the continuity of supply of consumers are presented in more detail.
PL
Chcąc spełnić wymóg bezprzerwowej dostawy energii elektrycznej do odbiorcy końcowego, istotne jest zapewnienie bezawaryjnej pracy systemu elektroenergetycznego, co nie zawsze jest możliwe do spełnienia z uwagi na występowanie zakłóceń zwarciowych, które to powodują pojawienie się nieplanowanych przerw zasilania. Istotnym zadaniem elektroenergetycznej automatyki zabezpieczeniowej jest ograniczenie skutków działania awarii wywołanych np. przepływem prądu zwarciowego (automatyka eliminacyjna) oraz ograniczenie do absolutnego minimum obszaru odbiorców pozbawionych zasilania (automatyka restytucyjna). Aby obie automatyki mogły prawidłowo zadziałać oraz spełnić powierzoną im rolę w sposób prawidłowy, konieczne jest jej właściwe sparametryzowanie (dobór progów oraz czasów opóźnienia zadziałania), ale i również późniejsze zbadanie w celu weryfikacji poprawności jej działania, zgodnie z oczekiwaniami projektowymi. W artykule przedstawiono procedurę testowania popartą wynikami badań dla pojedynczego punktu zabezpieczającego, jak i również kompletnego systemu automatycznej rekonfiguracji sieci na przykładzie systemu REZIP. Na potrzeby badania automatyki REZIP wykorzystano wyniki symulacji zwarciowych fragmentu sieci SN, zastępując tym samym potrzebę wykonywania rzeczywistych prób zwarciowych w systemie elektroenergetycznym.
EN
In order to meet the requirement of uninterruptible supply of electricity to the end user it is important to ensure failure-free operation of the system, which is not always possible to achieve due to the occurrence of short-circuit disturbances, which cause unplanned power outages. An important task of the electrical power system protection & automation is to limit effects of faults caused e.g. by the flow of short-circuit current (elimination type automatics) and limitation to the absolute minimum of the area of customers deprived of power supply (restitution automatics). That both automatics systems can work properly and fulfill their task correctly and fulfill their role in a proper way, it is necessary to parameterize them properly (selection of thresholds and tripping delay times), but also testing in order to verify the correctness of its operation in accordance with the design expectations. The paper presents testing procedure supported by test results for a single protection point as well as for the complete system of automatic network reconfiguration on the example of the REZIP system. For the purpose of testing the REZIP automatics, the results of short-circuit simulations were used of a fragment of the MV network, thus replacing the need to perform actual short-circuit tests in the power system.
PL
Artykuł przedstawia zbiór automatyk i funkcji reklozera KTR 27 (Rec25_Al) firmy Tavrida Electric. Omawia szerzej kluczowe funkcje zaimplementowane w najnowszej wersji oprogramowania reklozera.
EN
The article presents a group of automatics and functionalities of Tavrida Electric KTR 27 (Rec25_Al) recloser. It describes in more detail the key functions implemented in the latest version of recloser software.
EN
This paper presents the influence of distributed generation DG and reclosers placement on the reliability of distribution network. The brute force method and evolutionary algorithm were used to solve the optimization task. The placement of the switches was determined independently using two criteria. The first criterion is the reserve factor, while the second criterion is the SAIDI index. The proposed methods were tested on a real medium voltage distribution system in two variants of operation: with and without.
PL
W artykule przedstawiono wpływ generacji rozproszonej i lokalizacji reklozerów na niezawodność sieci dystrybucyjnej. Zastosowano algorytm przeglądu zupełnego oraz algorytm ewolucyjny. Lokalizację reklozerów ustalono stosując dwa kryteria: współczynnik rezerwowania oraz wskaźnik SAIDI. Obliczenia zrealizowano dla rzeczywistej sieci średniego napięcia.
PL
Realizacja funkcji zabezpieczeniowych zaimplementowanych w terminalach zabezpieczeniowych reklozerów pozwala na skuteczną ochronę sieci dystrybucyjnych średnich napięć przed skutkami występujących w nich zakłóceń. Terminale zabezpieczeniowe tych urządzeń powinny być poddawane cyklicznym badaniom eksploatacyjnym w celu sprawdzenia poprawności ich działania. Zastosowanie w reklozerach niekonwencjonalnych przetworników pomiarowych wymusza niestandardową konstrukcję wejść pomiarowych terminali zabezpieczeniowych, dostosowaną do poziomu sygnałów wyjściowych z zastosowanych przetworników pomiarowych. Determinuje to konieczność zastosowania interfejsów testowych przeznaczonych dla danego typu reklozera. Interfejsy te przetwarzają sygnały generowane przez tester zabezpieczeń do poziomu dostosowanego do wejść pomiarowych terminali zabezpieczeniowych zastosowanych w reklozerach. Rozwiązanie to zmienia podejście do procesu badania terminali zabezpieczeniowych reklozerów i w pewnych przypadkach może być przyczyną dodatkowych błędów mających wpływ na ocenę poprawności ich działania. W związku z tym w artykule scharakteryzowano tok postępowania przy testowaniu terminali zabezpieczeniowych reklozerów oraz zidentyfikowano potencjalne problemy, które mogą pojawić się w trakcie tych działań.
EN
Realization of implemented protection functions in relays of reclosers allows for effective protection of medium voltage distribution networks against the disturbances effects. The protection terminals of these devices shall be subject to cyclic testing in order to verify the correctness operation. Application in this devices unconventional measurement transducers require a non-standard construction of measurement inputs of protection terminals. This determines the use of test interfaces dedicated to a given type of recloser. These interfaces process the signals generated by the protection tester to the level adjusted to the terminal’s measurement inputs used in reclosers. This solution changes approach to the process of testing reclosers and in some cases may give rise to additional errors, having an impact to the assessment of correctnes their operation. Therefore, the article describes the procedure for testing the protection terminals of reclosers and identifies the following potential risks the problems that may arise in the course of these activities.
PL
Instytut Elektroenergetyki Politechniki Poznańskiej i firma Relpol podjęły współpracę nad realizacją koncepcji tzw. reklozera ziemnozwarciowego. Urządzenie to, ze swojego założenia, ma mieć możliwość łączenia prądów obciążenia linii oraz wyłączania zwarć doziemnych w sieci SN. Kluczowe aspekty pracy takiego reklozera mają dotyczyć przede wszystkim maksymalnej skuteczności wykrywania i szybkiego wyłączania zwarć doziemnych za pomocą typowego rozłącznika, czyli urządzenia znacznie tańszego jak w przypadku typowego pełnowartościowego reklozera. W artykule przedstawiono również parametry urządzenia sterującego (CZIP - SRZ), które wyposażono w odpowiednie algorytmy pomiarowe i decyzyjne oraz w istotne funkcje sterowania rozłącznikiem. Omówiono wyniki badań, które wykonano w warunkach laboratoryjnych oraz w trakcie eksperymentu zrealizowanego w rzeczywistej sieci 15 kV.
EN
Institute of Electrical Power Engineering of Poznan University of Technology and Relpol S.A. have started cooperation on the implementation of the earth fault recloser concept. This device, according to the idea, is supposed to have possibility of connecting line load currents and switching off earth faults in the MV network. The key aspects of such a recloser’s work are to primarily focus on the maximum effectiveness of detecting and quickly switching off earth faults by means of a typical switch disconnector, i.e. a much cheaper device as in the case of a typical full-value recloser. The article also presents the parameters of the control device (CZIP - SRZ), which are equipped with the appropriate measurement and decision algorithms as well as important control functions of the disconnector. Discussed are the results of the tests, which were carried out in laboratory conditions and during the experiment carried out in a real 15 kV network.
PL
W artykule omówione zostały wybrane elementy inteligentnych sieci elektroenergetycznych: rozdzielnice średniego napięcia oraz reklozery. Zwrócono uwagę na poprawne nazewnictwo oraz elementy zapewniające bezpieczeństwo w czasie eksploatacji sieci inteligentnych, w szczególności rozdzielnic i reklozerów.
EN
The article discusses the selected elements of intelligent power grids: medium voltage switchgear and reclosers. Attention has been paid to the correct naming and safety features for the operation of intelligent networks, in particular medium voltage switchgears and reclosers.
9
EN
Distribution system operators (DSOs) are now undertaking intensive actions aimed at increasing the degree of medium voltage (MV) grid automation. One of the means to accomplish this task are reclosers. The use of these devices enables improved reliability of electricity supplies to recipients by automatic separation of the disturbance-affected grid portion (then – differently than previously – recipients connected to the rest of the grid can be supplied with electricity). In addition, with the appropriate functional connection of these devices, it is possible to develop master systems for grid operation monitoring and control. Therefore, the paper compares the functionality and parameters of reclosers made by selected manufacturers in terms of assessing their suitability for the development of extensive restitutive automation systems.
PL
Operatorzy systemów dystrybucyjnych (OSD) podejmują obecnie intensywne działania mające na celu zwiększenie stopnia automatyzacji sieci średnich napięć (SN). Jednym ze środków umożliwiających realizację tego zadania są reklozery. Zastosowanie tych urządzeń umożliwia poprawę niezawodności dostaw energii elektrycznej do odbiorców poprzez automatyczne wydzielenie fragmentu sieci objętego zakłóceniem (wówczas – odmiennie niż dotychczas – odbiorcy przyłączeni do pozostałej części sieci mogą być zasilani w energię elektryczną). Ponadto, przy odpowiednim powiązaniu funkcjonalnym tych urządzeń, istnieje możliwość konstruowania nadrzędnych systemów nadzoru i sterowania ruchem sieciowym. W związku z tym w artykule porównano funkcjonalność i parametry reklozerów wybranych producentów pod kątem oceny ich przydatności do tworzenia rozbudowanych systemów automatyki restytucyjnej.
PL
W artykule dokonano porównania metod pomiaru prądu przez konwencjonalne przekładniki prądowe oraz poprzez sensory prądowe. Szczególną uwagę zwrócono na konstrukcję, dokładność przetwarzania oraz zakres wartościowy transformacji tych urządzeń. Ponadto przedstawiono wyniki badań dotyczące dokładności przetwarzania cewki Rogowskiego stosowanej w napowietrznych wyłącznikach próżniowych.
EN
The paper presents a comparison of current measurement methods by conventional current transformers and current sensors. Special attention has been focused on construction, accuracy and the range of transformation. In addition, shows the results of Rogowski coil accuracy used in reclosers.
PL
Poprawa ciągłości dostawy energii elektrycznej, realizowanej za pośrednictwem sieci średniego napięcia, znajduje się w centrum zainteresowania przedsiębiorstw energetycznych. W artykule przedstawiono analizę wpływu instalowania w głębi sieci średniego napięcia reklozerów na jej niezawodność. Przedstawiono, jaki wpływ mają zainstalowane reklozery na wartości niedostarczonej energii elektrycznej i skrócenie czasu lokalizacji zakłóceń w analizowanej sieci średniego napięcia rejonu energetycznego.
EN
Improvement of continuity of the electrical energy supply, being realized by means of the medium-voltage power network, attracts interest of the energetic companies. The paper presents the analysis of influence of the reclosers, being installed deeply in the medium-voltage network, on its reliability. Two principal effects of applying the reclosers in the considered medium-voltage network have been analysed: decrease of the unsupplied electrical energy value, and diminution of the disturbance localization time.
EN
These new generation devices which are being tried for the first time in our country are low cost, can be used instead of output cells of transformer centers which are in medium-voltage lines experiencing problems of expropriation, offer the maximum level of security, don’ t require maintenance for 20 years and offer an easy opportunity to intervene. In addition, protecting the working efficiency of these new products’ electricity transmission lines and distribution systems are evaluated in this study.
PL
W artykule opisano zastosowanie sekcjonalizerów i reklozerów w sieci elektroenergetycznej, jako urządzeń o stosunkowo niskich kosztach utrzymania i dobrych parametrach ochrony linii. Omówiono warunki działania urządzenia w praktyczny zastosowaniu.