Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 36

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  railroad
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available remote Alternative structures of railroad subgrade protective layers
EN
Structural improvement of the upper zone of railroad subgrade, designed based on local geotechnical testing, may not always prove adequate to the actual geotechnical conditions observed in field during construction. When such discrepancies occur, it is necessary to adopt and install alternative solutions. The article presents two basic protective layer structures (single- and double-layer) that increase the bearing capacity of the upper zone of railroad subgrade, as well as three most popular alternative solutions (layer of increased thickness, geogrid-reinforced layer and double-layer structure with the bottom layer consisting of hydraulically-stabilized soil). The analysis included the influence of introduction of such alternative structures on the decrease in the required minimum real values of secondary deformation modulus of subgrade observed in static plate load tests before structural improvement that would still enable one to obtain the target modulus values after installation of the chosen alternative solution. Conditions of use and applicability of the analyzed alternative structures in various geotechnical conditions are also discussed. Two analyzed structures – i.e. single layer of increased thickness and single geogrid-reinforced layer – are usable when small differences occur between the design and actual field values of secondary deformation moduli. The structure incorporating a layer of hydraulically-stabilized soil is usable in the case of considerable deficiency in secondary deformation moduli of the subgrade.
PL
Konstrukcje wzmocnień górnej strefy podtorza, projektowane na podstawie wyników punktowych geotechnicznych badań podłoża, nie zawsze są adekwatne do stwierdzonych na budowie rzeczywistych warunków gruntowych. Konieczne jest wówczas przyjęcie i zastosowanie odpowiednich konstrukcji zamiennych. W artykule przedstawiono dwie podstawowe konstrukcje wzmocnień górnej strefy podtorza (dwu- i jednowarstwową) oraz trzy najczęściej stosowane rozwiązania zamienne (konstrukcję o zwiększonej grubości, konstrukcję zbrojoną geosiatką oraz konstrukcję z warstwą gruntu stabilizowanego spoiwem hydraulicznym). Przeanalizowano wpływ zastosowania wymienionych konstrukcji zamiennych na możliwość zmniejszenia wymaganych wartości wtórnych modułów odkształcenia gruntów podtorza przed wzmocnieniem, pozwalających na osiągnięcie docelowych wartości po zastosowaniu danego wzmocnienia. Omówiono warunki stosowania rozpatrywanych konstrukcji zamiennych oraz ich przydatność w zależności od występujących na budowie warunków gruntowych. Dwie z analizowanych konstrukcji – o zwiększonej grubości oraz zbrojona geosiatką – są przydatne w przypadku wystąpienia małych różnic pomiędzy rzeczywistymi a projektowymi wartościami wtórnych modułów odkształcenia gruntów podtorza. Konstrukcja z warstwą gruntu stabilizowanego spoiwem hydraulicznym jest użyteczna w razie stwierdzenia na budowie znacznego niedoboru wartości wtórnych modułów odkształcenia gruntów podtorza.
2
Content available remote Metoda ruchomej cięciwy do wyznaczania krzywizny osi toru
PL
W pracy podjęto kwestię wyznaczania krzywizny osi toru kolejowego w celu stworzenia możliwości określenia charakterystyk geometrycznych pomierzonej trasy. Wykorzystano przy tym nową koncepcję wyznaczania krzywizny metodą zmiany kątów nachylenia ruchomej (wirtualnej) cięciwy, na podstawie znajomości współrzędnych kartezjańskich danego rejonu trasy. Weryfikacja zaproponowanej metody, przeprowadzona na jednoznacznie zdefiniowanych modelowych układach geometrycznych torów, wykazała całkowitą zgodność uzyskanych wykresów krzywizny z wykresami stanowiącymi podstawę uzyskania odpowiadającego rozwiązania geometrycznego. Zastosowanie metody ruchomej cięciwy do wyznaczania krzywizny eksploatowanego toru kolejowego wykazało, że uzyskane wykresy krzywizny różnią się wyraźnie od wykresów dla układów modelowych; mają one mniej regularny, oscylacyjny charakter, co wynika z występujących deformacji toru oraz błędu pomiarowego. Nie przeszkadza to jednak, żeby na takiej podstawie można było oszacować podstawowe parametry geometryczne pomierzonego układu.
EN
The paper adresses the issue of determining the curvature of the axis of the railway track in order to enable the determination of the geometrical characteristics of the measured route. A new concept of determining the curvature was used by the method of changing the angles of inclination of a moving (virtual) chord based on the knowlege of the Cartesian coordinates of a given region of the route. The verification of the proposed method, carried out on unambiguosly defined model geometric track layouts, showed the complete agreement of the obtained curvature diagrams with the diagrams constituting the basis for obtaining the corresponding geometric solution. The use of the moving chord method to determine the curvature of the operated railway track showed that the obtained curvature plots clearly differ from those for model layouts; they have a less regular, oscillating character, which results from the track deformation and measurement error. However, this does not prevent the possibility of estimating the basic geometrical parameters of the measured layout on this basis.
EN
Geotechnical examinations of the subgrade are conducted before its rehab, repair or upbringing works. Due to variability of parameters of the subgrade soil over time, and limited scope of such examinations, the geotechnical model of the subgrade, identified based on test results, is inevitably characterised by uncertainty. The actual soil conditions are identified as part of geotechnical checks performed during repair or upbringing building works. Using these test results, subgrade soil parameters are then checked for conformance with their design values. In case any discrepancy is found, or the ensuing inadequacy of the design construction of protective layers in the actual soil conditions, appropriate revised constructions are designed and implemented. This paper describes and compared the five most frequently used types of revised constructions of protective layers of the subgrade, whose parameters are adjusted to the prevailing local soil conditions. For each type of construction, its material requirements were analysed, as well as its required volume of earth works and its execution unit cost were identified. Upon this basis, the discussed protective layer revised constructions' efficiency and their recommended application conditions were determined, depending on their prevailing actual soil conditions.
PL
Artykuł dotyczy analizy podkładek podpodkładowych (USP) i mat podpodsypkowych (UBM), które są stosowane w podsypkowych konstrukcjach dróg szynowych jako izolatory wibroakustyczne. Rozpatrywano cztery rodzaje USP i dwa UBM. Przedstawiono wyniki badań laboratoryjnych, które zostały wykorzystane jako parametry wejściowe do modelu mechanicznego konstrukcji. Omówiono autorski model mechaniczny konstrukcji o czterech stopniach swobody (4DoF).
EN
The present paper is dedicated to the analysis of under sleeper pads (USP) and under ballast mats (UBM), which are resilient elements used in the ballasted track systems as vibration isolators. Four types of USP and two types of UBM are considered. The authors present results of laboratory tests which are then used as input values in the mechanical model of the structure. An original four-degree-of-freedom (4DoF) mechanical model of the system is presented.
PL
W artykule przedstawiono najczęstsze przyczyny występowania braku pełnych efektów wzmocnienia podtorza warstwą ochronną czyli niedoboru wartości geotechnicznych parametrów odbiorczych podtorza (modułów odkształcenia i wskaźników zagęszczenia). Omówiono sposoby rozpoznawania tych przyczyn i metody ich eliminacji. Zaprezentowano autorski algorytm umożliwiający szybkie zdiagnozowanie przyczyn występowania deficytu wartości geotechnicznych parametrów odbiorczych podtorza oraz dobór i wdrożenie odpowiednich działań naprawczych.
EN
The article presents the most common causes of incomplete effects of protective layer application or reduction of the required geotechnical parameters values of a subgrade (the module of base deformation and the density rate). There were discussed various methods of recognizing the causes and eliminating them. The article presents the author’s algorithm, which enables the quick diagnosis of the reasons for the subgrade acceptance parameters deficit as well as the selection and implementation of appropriate corrective actions.
PL
W artykule przedstawiono najczęstsze przyczyny występowania problemów z uzyskaniem wymaganych wartości parametrów odbiorczych podtorza z warstwą ochronną (modułów odkształcenia i wskaźników zagęszczenia). Omówiono sposoby ich rozpoznawania. Zaprezentowano metody eliminacji ograniczeń i niepowodzeń, umożliwiające uzyskanie pełnych efektów wzmocnienia podtorza warstwą ochronną. Na przykładach zaprezentowano sposób postępowania w przypadku braku pełnych efektów zastosowania warstwy ochronnej.
EN
The article presents the most common causes of problems with obtaining the required parameter values of a subgrade with a protective layer during the technical acceptance (the module of base deformation and the density rate). There were discussed various methods of recognizing them. The methods eliminating the limitations and problems allowing to obtain full effects of the subgrade reinforcement with the protective layer were presented. Moreover, the way of proceeding in case of lack of full protective layer application effects was presented in examples.
7
PL
W artykule przedstawiono najczęstsze przyczyny występowania problemów z uzyskaniem wymaganych wartości parametrów odbiorczych podtorza z warstwą ochronną (modułów odkształcenia i wskaźników zagęszczenia). Szczegółowo omówiono różne sposoby ich rozpoznawania. Wskazano ograniczenia i uwarunkowania badań dla rozpoznania przyczyn braku efektu wzmocnienia podtorza warstwą ochronną. Zaprezentowano metody eliminacji ograniczeń i niepowodzeń umożliwiające uzyskanie pełnych efektów wzmocnienia podtorza warstwą ochronną.
EN
The article presents the most common causes of problems with obtaining the required parameter values of a subgrade with a protective layer during the technical acceptance (the module of base deformation and the density rate). There were discussed in detail various methods of recognition. Pointed the limitations and determinants of the research to recognize the reasons for the lack of the reinforcement effect of the subgrade with the protective layer. Presented methods that eliminates the limitations and problems allowing to obtain full effects of the subgrade reinforcement with the protective layer.
PL
W artykule opisano najczęstsze przyczyny występowania problemów z uzyskaniem wartości parametrów odbiorczych podtorza z warstwą ochronną. Przedstawiono klasyfikację przyczyn z wydzieleniem czterech ich zbiorów: pogorszenie warunków gruntowo-wodnych, błędy projektowe, błędy wykonawcze oraz ograniczenia konstrukcyjno-wykonawcze. Podano różne sposoby rozpoznawania przyczyn i wskazano metody ich eliminacji umożliwiające uzyskanie pełnych efektów wzmocnienia podtorza warstwą ochronną.
EN
This article describes the most common causes of problems encountered in obtaining the subtraction parameters of a subgrade with a protective layer. The classification of the causes with the separation of four collections is described: deterioration of soil and water conditions, design errors, implementation errors and structural and executive constraints. Different methods for recognizing causes and eliminating them were given. These methods allow obtaining the full effects of subgrade’s reinforcement with protective layer.
PL
W artykule opisano najczęstsze przyczyny występowania problemów z uzyskaniem wartości parametrów odbiorczych podtorza z warstwą ochronną. Dokonano próby klasyfikacji przyczyn z wydzieleniem czterech ich zbiorów: pogorszenie warunków gruntowo-wodnych, błędy projektowe, błędy wykonawcze oraz ograniczenia konstrukcyjno-wykonawcze. Podano sposoby rozpoznawania przyczyn i wskazano zalecenia wykonawcze umożliwiające zmniejszenie prawdopodobieństwa wystąpienia niekorzystnych zjawisk mających wpływ na stan odkształcalności i zagęszczenia podtorza z warstwą ochronna.
EN
The article presents the most common causes of problems with acquiring expected parameters of a subgrade with a protective layer. A classification attempt was made by extracting four sets of the causes: a decrease of soil and water conditions, errors done at design, errors at construction site and technological limitations. Methods for inquiring about the problems’ causes are given, together with recommendations for the subgrade and the protective layer construction. The recommendations aim to minimise an occurrence probability of adverse phenomena influencing deflection and compactness state of the subgrade and the protective layer.
PL
W artykule omówiono proces przebudowy górnej strefy podtorza podczas jego naprawy lub modernizacji, z uwzględnieniem badań geotechnicznych do projektu i podczas wykonawstwa na budowie oraz sposobów obliczania konstrukcji stosownych wzmocnień. Na tej podstawie przedstawiono możliwości zastępowania zaprojektowanej konstrukcji inną równoważną jej postacią, gdy występują ograniczenia geometryczne lub techniczne, wcześniej (przed projektem) nie rozpoznane.
EN
This paper discusses the process of reconstruction of the railroad subgrade upper zone during its repair or modernization. The following aspects were taken into account: geotechnical tests for the project, tests carried out during works on the construction site and methods of calculating required reinforcement. On this basis, the possibility of replacing designed construction with other equivalent form was shown, when there are geometric or technical restrictions, which were not recognized earlier (before the project).
11
Content available remote Zależność stanu zagęszczenia podtorza od stanu jego odkształcalności
PL
W artykule omówiono sposób wykonywania i opracowywania wyników pomiarów odkształcalności podtorza. Przedstawiono wymagane wartości modułów odkształcenia oraz wskaźników zagęszczenia i odkształcenia. W celu określenia głębokości strefy oddziaływania płyty próbnej w podtorzu przeprowadzono analizę stanu naprężenia i odkształcenia uwarstwionego podtorza. Podano wnioski dotyczące stosowalności normowych zależności wartości wskaźnika odkształcenia i wskaźnika zagęszczenia.
EN
The following paper discusses the method of exercise and development of measurement results of subgrade deformability. It shows the required values of the modules of deformation as well as density and deformation indexes. The analysis of stress and deformation of laminar subgrade has been made in order to determine the depth of interaction zone on a test plate in a subgrade. Presented conclusions regard the applicability of normative dependencies on the value of both deformation index and density index.
12
Content available Konserwacja i naprawa dróg szynowych
PL
Utrzymanie w stanie pełnej przydatności eksploatacyjnej nawierzchni i torów zapewnia spokój i bezpieczeństwo ruchu pociągów z prędkością zgodną z rozkładem jazdy. Ważną rolę w tym względzie odgrywa odpowiednia diagnostyka, która zapewnia dostrzeżenie w porę wszelkich usterek, braków i niedokładności, umożliwiając ich bezzwłoczne usunięcie.
PL
Celem przeprowadzonych badań była ocena zanieczyszczenia występującego wzdłuż linii kolejowej zlokalizowanej na obrzeżach Warszawy, poprzez określenie zawartości wybranych metali ciężkich w wierzchniej warstwy gleby i mchu (Pleurozium schreberi). Badania zostały przeprowadzone w południowej części Warszawy (centralna Polska) w trzech punktach pomiarowych: przed przejazdem kolejowym, i za przejazdem w kierunku północnym. Próbki gleby i mchu zostały pobrane w każdego punktu w odległościach 1, 10, 20 i 30 m od linii kolejowej. Oznaczenia zawartości metali ciężkich wykonano metodą spektroskopii absorpcji atomowej (ASA). Spośród analizowanych punktów najwyższą zawartość Cu, Zn, Ni i Pb w glebie odnotowano w odległości 1 m od szlaku kolejowego. Odczyn (pH) gleby miał najniższą wartość w odległości 30 m (punkt pomiarowy A i B) natomiast najwyższą w odległości 1 m, natomiast wartości EC były najwyższe w punkcie pomiarowym A (okolice stacji kolejowej). Maksymalne zawartości metali ciężkich (Cu, Zn, Ni) w mchu (Pleurozium schreberi) występowały w bezpośredniej bliskości szlaku kolejowego.
EN
The purpose of the studies was to assess environmental contamination alongside railway lines in the suburbs of Warsaw by determining the concentrations of selected heavy metals in surface layer of soil as well as moss (Pleurozium schreberi). The studies were conducted in the southern part of Warsaw (central Poland) in three sampling points: before the railway station, and after the station to the northbound. Soil and moss samples were taken from each of these sites at distances of 1, 10, 20 and 30 m from the railroad. Heavy metals were analyzed using flame atomic absorption spectrometry (AAS). The highest Cu, Zn, Ni, and Pb contents in soil were found 1 m from the railroad at each of the analyzed sites. pH was lowest at 30 m (sampling points A and B), and highest at 1 m whilst EC value was highest in sampling point A (near railway station). Maximum contents of heavy metals (Cu, Zn, Ni) in Pleurozium schreberi moss were most often present in the direct proximity of the railroad tracks.
PL
Artykuł o znaczeniu wartości wtórnych modułów odkształcenia podtorza w procesie jego modernizacji, o przyczynach ograniczeń ich stosowania i o poprawności rozumienia próbnych obciążeń podtorza. Na dwóch przykładach wskazano ograniczony zakres stosowania testu odkształcalności podtorza, w przypadku występowania w podłożu gruntów o małej wytrzymałości oraz niestateczności nasypu.
EN
A paper is about the importance of secondary distortion modules of railway subgrade in the process of modernization, about reasons of the limited scopes and the correctness of understanding subgrade load tests. Two examples prove the limited scope of the distortion test of railway subgrade in case of presence in the subgrade low-strength soils and embankment instability.
15
Content available remote Stosowalność wyników badań odkształcalności podtorza
PL
Referat jest głosem w dyskusji o znaczeniu wartości wtórnych modułów odkształcenia podtorza w procesie jego modernizacji. Ogólnie prezentuje sposób przeprowadzania obliczeń i analizy wyników badań oraz głębokości oddziaływania płyty próbnej. Na przykładzie wykazano ograniczony zakres stosowania testu odkształcalności podtorza w przypadku występowania w podłożu gruntów o małej wytrzymałości.
EN
In this paper we take part in a discussion about the importance of secondary distortion modules of railway subgrade in the process of modernization. A method of performing calculations and analysis of research results and the depth of working area of the test plate was presented in a general way. An example proves the limited scope of the distortion test of railway subgrade in case of presence in the subgrade low-strength soils.
PL
Od 1 stycznia 2015 r. zaczął obowiązywać nowy pakiet technicznych specyfikacji interoperacyjności. Do tych dokumentów odwołuje się wiele znowelizowanych w ostatnich latach krajowych ustaw i rozporządzeń. Opisano wybrane grupy parametrów określonych w nowych TSI Infrastruktura, których znaczenie w projektowaniu dróg kolejowych uznano za najistotniejsze.
EN
1.01.2015 a new set of Technical Specifications of Interoperability began to be obligatory. These documents have greater meaning because some national laws and orders, which were amended in last years, include references to them. There were described in short some chosen groups of the technical parameters listed in the new TSI Infrastructure, which are considered to be the most important in the process of railroads’ designing.
PL
W artykule przedstawiono dwie najczęściej stosowane metody obliczania wzmocnień górnej strefy podtorza. Z wykorzystaniem metody modułu ekwiwalentnego zaprezentowano sposób opracowania wykresów zależności grubości warstwy ochronnej od właściwości gruntów podtorza. W analizie uwzględniono trzy podstawowe parametry uzyskiwane z badań podtorza – stopnie plastyczności i zagęszczenia oraz wtórny moduł odkształcenia. Przedstawiono przykładowe wykresy zależności grubości pojedynczej warstwy ochronnej z materiału o module odkształcenia 200 MPa od właściwości gruntów podtorza.
EN
This paper presents two the most frequently used methods of calculating reinforcements of the upper zone of railway subgrade. The way, how to develop graphs of the relationship between the thickness of protective layer and soil properties using the method of equivalent modulus was presented in the paper. The analysis includes three basic parameters obtained from the railway subgrade tests: liquidity indexes, density indexes and values of secondary distortion modulus. This paper presents exemplary graphs of the relationship between the thickness of a single protective layer build of a material having a compressibility modulus equal to 200 MPa and subgrade soil properties.
PL
W artykule zaprezentowano wyniki wyznaczenia współrzędnych przebiegu trasy kolejowej metodami aproksymacji wielomianowej i interpolacji krzywą kubiczną na podstawie pomiarów czasu rzeczywistego GPS, zrealizowanych z wykorzystaniem polskiej aktywnej sieci geodezyjnej ASG-EUPOS. Rozważania teoretyczne poparte zostały praktycznym przykładem aplikacyjnym opartym na zrealizowanych pomiarach inwentaryzacyjnych zmodernizowanego odcinka toru kolejowego relacji Somonino – Gdańsk.
EN
The article presents results of defining railway route course position using methods of polynomial approximation and cubic spline interpolation based on real time GPS measurements supported by active geodetic network ASG-EUPOS. Mathematical basis of the received solution are presented as well. Theoretical considerations were backed by an example of their application in order to illustrate railway route course present on 06.11.2010. Moreover, the article covers an issue of the output data’s spatial resolution and its effect on accuracy of linear models defined on its basis.
19
PL
W artykule podjęto próbę oszacowania niepewności pomiarowych występujących w trakcie wyznaczania wartości modułów odkształcenia. Opisano sposób wyznaczania niepewności w pomiarach pojedynczych i seryjnych. Z wykorzystaniem przykładowych wyników badania odkształcalności podłoża obliczono niepewności pomiarowe. Na podstawie przeprowadzonej analizy opracowano wnioski.
EN
The paper presents a trial of the estimation of measurement uncertainties in calculation of the subgrade deflection modulus and the distortion rate. A method of calculation of the uncertainty for single measurements and series of measurements is shown. The measurement uncertainties were computed with the use of example examination of the subgrade distortion. Finally, some conclusions from the conducted analysis have been drawn.
20
Content available remote Projektowanie wzmocnień podtorza według jego właściwości
PL
W referacie przedstawione są dwa główne sposoby obliczania wzmocnień górnej strefy podtorza stosowane w PKP. Omówiono sposoby określania parametrów geotechnicznych gruntów podtorza do projektów wzmocnień. Podano przykłady opracowania wykresów zależności grubości warstwy ochronnej od właściwości gruntów w podtorzu. Na podstawie analizy dopuszczalnych obciążeń gruntów i obciążeń od nawierzchni omówiono przydatność podtorza do budowy warstw ochronnych.
EN
This paper presents two main methods of calculating the reinforcements of the railway subgrade used in Polish State Railways (PKP). Ways of determining geotechnical parameters of the railway subgrade soil in order to designing reinforcements were discussed. The article gives examples of developing a graph of the relationship between the thickness of protective layer and soil properties. The usefulness of the subgrade for construction of protective layers was discussed on the basis of analysing permissible load on the subgrade and permissible load on the track.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.