Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 94

Liczba wyników na stronie
first rewind previous Strona / 5 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  quantitative analysis
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 5 next fast forward last
EN
The prevalence of lifestyle diseases and trends related to healthy eating contribute to the constant search for chemical compounds with specific biological activity. Studies are conducted on plants and substances of natural origin that have been used in medicine for millennia. Techniques of vibrational spectroscopy are an underrated group of methods enabling direct analysis of plant raw material and food in their native forms. The presented examples of Arabidopsis tissues, various species and hybrids of poplar and Cistus herb classification, as well as quantitative analyses of active compounds in plant material and pharmaceutical products and determination of physicochemical parameters of common food (i.e. milk, yoghurts, pasta and flour), demonstrate the possibility of using vibrational spectroscopy for comprehensive analysis of samples of natural origin. Typical measurement techniques and chemometric methods are briefly described in this paper. The scheme of quantitative analysis based on vibrational spectra is shown and the impact of selected experimental parameters on the accuracy of the obtained results is discussed. The imaging techniques used to analyse the changes in plant tissue structures caused by genetic mutations were also presented.
EN
The paper focuses on the static behavior of double-layered tensegrity grids. Due to the specific characteristics, like the self-stress states and infinitesimal mechanisms, tensegrities can be used as deployable structures. For such structures, the possibility of the control of the behavior is very important. The main purpose of the work is to prove that the control of tensegrity structures with mechanisms is possible. The stiffness of such structures is found to depend not only on the geometry and material properties, but also on the initial prestress level and external load. In the case, when mechanisms do not exist, structures are insensitive to the initial prestress. It is possible to control the occurrence of mechanisms by changing the support conditions of the structure. Grids built with modified Simplex modules are considered. Two-stage analysis is performed. Firstly, the presence of the characteristic tensegrity features is examined and then, on that basis, the structures are classified into one of two classes. Next, the influence of the level of initial prestress on the behavior of structures under static load is analyzed. To evaluate this behavior, a geometrically non-linear model is used.
PL
W pracy analizowano statyczne zachowanie się dwuwarstwowych kratownic typu tensegrity. Z uwagi na występowanie charakterystycznych cech, takich jak stany samonaprężenia i mechanizmy infinitezymalne, konstrukcje te mogą być stosowane jako rozkładalne. W takim przypadku bardzo ważna jest możliwość kontrolowania zachowania się konstrukcji. Głównym celem pracy jest wykazanie, że taka kontrola jest możliwa w przypadku struktur tensegrity, które charakteryzują się występowaniem mechanizmów. Sztywność takich struktur zależy nie tylko od geometrii i właściwości materiału, ale także od poziomu wstępnego sprężenia i od obciążenia zewnętrznego. W przypadku, gdy mechanizmy nie występują, konstrukcje są niewrażliwe na poziom wstępnego sprężenia. Występowanie mechanizmów można kontrolować poprzez zmianę warunków podparcia konstrukcji. W pracy rozważane były rozkładalne kładki zbudowane ze zmodyfikowanych modułów Simplex. Rozpatrzono konstrukcje o różnych warunkach podparcia składające się z różnej liczby modułów. Analiza struktur tensegrity jest dwuetapowa. Pierwszym etapem jest analiza jakościowa, która polega na identyfikacji immanentnych własności tensegrity, takich jak stany samonaprężenia i mechanizmy infinitezymalne. Na tej podstawie konstrukcje są klasyfikowane jako struktury o cechach tensegrity klasy 1 lub klasy 2. W pierwszym przypadku struktury charakteryzują się występowaniem mechanizmów, natomiast w drugim nie. Drugim etapem jest analiza ilościowa. Jest to analiza parametryczna, która obejmuje wpływ poziomu wstępnego sprężenia oraz zmiany warunków podparcia na zachowanie konstrukcji pod obciążeniem statycznym. W szczególności analizowany jest wpływ na przemieszczenia i wytężenie konstrukcji.
EN
A new method for the analysis of four target flavonoids in two kinds of citrus samples by ultra-high performance supercritical fluid chromatography (UHPSFC) method was developed. Main variables affecting the UHPSFC separation were optimized, and under the optimized conditions the four target compounds (tangeretin, nobiletin, hesperetin and naringenin) can be separated within 10 min. The UHPSFC method allowed the determination of the four target compounds in the diluted stock solutions with limit of detection (LOD) ranging from 1.08 to 2.28 μg mL⁻¹, and limit of quantification (LOQ) ranging from 1.45 to 4.52 μg mL⁻¹, respectively. The coefficients of determination (R2) of the calibration curves were higher than 0.9950. The recoveries of the four target compounds at three different concentrations were in the range of 82.4–117.6%. The validation results demonstrated that the proposed method is simple, accurate, time-saving and environment friendly, and it is applicable to a variety of complex samples such as medicine-food dual purpose herbs and functional foods.
EN
This paperwork is focused on the quality of AlSi6Cu4 casting with different wall thicknesses cast into the metal mold. Investigated are structural changes (the morphology, size, and distribution of structural components). The quantitative analysis is used to numerically evaluate the size and area fraction of structural parameters (α-phase, eutectic Si, intermetallic phases) between delivered experimental material and cast with different wall thicknesses. Additionally, the Brinell hardness is performed to obtain the mechanical property benefits of the thin-walled alloys. This research leads to the conclusion, that the AlSi6Cu4 alloy from metal mold has finer structural components, especially in small wall thicknesses, and thus has better mechanical properties (Brinell hardness). These secondary Al-castings have a high potential for use in the automotive industry, due to the thin thicknesses and thus lightweight of the construction.
PL
W ostatnich latach obserwuje się zwiększone zastosowanie spektrometrii mas (MS) w diagnostyce laboratoryjnej i analizach biomedycznych. Analiza ilościowa metodą MS wiąże się z zastosowaniem standardów znakowanych izotopowo, które nie zawsze są dostępne handlowo bądź charakteryzuje je wysoka cena. Rozwiązaniem poszerzającym możliwość aplikacji metody MS w diagnostyce laboratoryjnej jest zastosowanie opracowanych przez autorów metod znakowania izotopowego związków chemicznych, umożliwiających otrzymanie standardów mogących znaleźć zastosowanie zarówno w analizie jakościowej, jak i ilościowej metodą MS lub wysokosprawnej chromatografii cieczowej sprzężonej ze spektrometrią mas (LC-MS). Badania te prowadzone są w Laboratorium Spektrometrii Mas Wydziału Chemii Uniwersytetu Wrocławskiego.
EN
Recently, mass spectrometry (MS) has become one of the most useful techniques in laboratory diagnostics and biomedical analysis. Quantitative MS analysis involves the application of isotopically labelled standards, which are expensive or not always available. A solution expanding the possibility of MS application in the laboratory diagnostics is the use of isotope labelling techniques of chemical compounds, developed by the authors. These methods facilitate the preparation of standards used in qualitative and quantitative analysis by MS or high-performance liquid chromatography coupled with mass spectrometry (LC-MS). The presented studies are conducted in the Mass Spectrometry Laboratory of the Faculty of Chemistry at the University of Wrocław.
EN
Different algorithms are used for the quantitative interpretation of optical spectra. Regression methods e.g CLS (Classical Least Squares) or PLS (Partial Least Squares) are often used in typical problems of laboratory spectroscopy. The spectra analysis is generally a multi-step process, in which, depending on the spectra type, modification of individual regression methods or special dedicated methods are applied. For example, contour length method or spectra length algorithm are used in this purpose. The basic version of the algorithm is very simple in terms of mathematics. It has been proposed for the analysis of spectra in the OP-FTIR open path spectroscopy, where there are significant fluctuations in the spectrum baseline. The spectrum length is a parameter closely related to the content of the analyzed gas component. Independently of spectral length algorithm, a method has been developed in which difference length of two spectra (measured and reference) is used to compare the spectra. The minimum length of the spectral difference is an indicator of their best fitting. The article presents two ways of using the spectrum length: as a direct and indirect parameter indicating the measured quantity on the basis of the spectrum. There were performed the spectrum length algorithm as a digital differentiating filter with a specific frequency response. There were also analyzed more advanced differentiating filter and the possibility of frequency spectrum filter design used in an analysis of optical spectral signal. There were performed the analysis of the spectrum length method in the case of the synthetic calibration involving the use of model spectra from simulations realized by HITRAN database. There were analyzed numerically the problem of the Instrument Line Shape influence on the synthetic spectra and results of the determining the content of components by the minimizing the difference of spectral length.
PL
Do ilościowej interpretacji widm optycznych wykorzystuje się wiele różnych algorytmów. W typowych zagadnieniach spektroskopii laboratoryjnej wykorzystuje się m. in. metody regresji CLS, PCR PLS. Interpretacja widm to często proces wieloetapowy, w którym w zależności od rodzaju widm wykorzystuje się modyfikację poszczególnych metod regresji lub też stosuje się specjalne metody dedykowane. Jedną z takich metod jest algorytm długości konturu lub też długości widma. Jego podstawowa wersja jest bardzo prosta pod względem matematycznym. Została zaproponowana do analizy widm ze spektroskopii otwartej ścieżki OP-FTIR, dla której występują znaczące fluktuacje linii bazowej widma. Długość widma jest parametrem, który jest odwzorowany bezpośrednio na zawartość danego składnika gazowego. Niezależnie od algorytmu długości widma powstała metoda, w której długość różnicy dwóch widm (mierzonego i odniesienia) służy do porównania widm. Minimalna długość różnicy widm jest wskaźnikiem ich najlepszego dopasowania. W pracy porównane zostaną obydwa sposoby wykorzystania długości widma: jako parametru bezpośrednio lub pośrednio wskazującego wielkość poszukiwaną na podstawie widma. Przeanalizowany zostanie algorytm długości widma jako cyfrowy filtr różniczkujący posiadający określoną charakterystykę częstotliwościową. Przeanalizowane zostanie zagadnienie wykorzystania bardziej zaawansowanego filtru różniczkującego oraz możliwość uwzględnienia w wyborze i projektowaniu filtra widma częstotliwościowego optycznego sygnału spektralnego. Kolejno poruszanym zagadnieniem będzie analiza metody długości widma w przypadku tzw. kalibracji syntetycznej polegającej na wykorzystaniu jako widm wzorcowych widm pochodzących z symulacji wykorzystujących bazę danych Hitran. Przeanalizowany numerycznie zostanie problem wpływu kształtu odpowiedzi instrumentu pomiarowego na syntetyczne widma i wyniki wyznaczania zawartości składników metodą minimalizacji długości różnicy widm.
EN
Anisodus tanguticus (Maxim.) Pascher is an important Tibetan folk medicine and the source of tropane alkaloids (TAs) grown in Qinghai-Tibet Plateau. There are marked differences in quality of A. tanguticus from geographic areas. The aim of present research was to establish a method for the quantitative analysis of TAs coupled with chemometrics analysis to trace geographical origins. Qualitative analysis of TAs in A. tanguticus was carried out using ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry and quantitative analysis of TAs in different plant organs from different geographical origin was achieved. Contents of TAs were subjected to the principal component analysis, and orthogonal partial least-squares discriminant analysis. The contents of the three marker compounds (anisodamine, anisodine and atropine) in the roots and acrial parts of A. tanguticus were positive correlated and varied significantly from different geographical origins. Principal component analysis, and orthogonal partial least-squares discriminant analysis results showed excellent discrimination between different geographical origin of A. tanguticus. This study could provide comprehensive evaluation and further utilization of A. tanguticus resources.
EN
Comparison of gas chromatographic methods GC/FID and GC/MS for quantification of 3-nitrotoluene (3-NT) in the presence of high concentrations of 2-nitrotoluene and 4-nitrotoluene, is presented. GC/FID linear regression allows calibration curves in the concentration range of mononitrotoluene (MNT) 0.5-10 mg/ml to be obtained. For GC/MS, a non-linear dependence of detector signal was observed, particular for higher MNTs concentrations. However, calibration data could be fitted stepwise with three separate calibration lines. Using regression parameters, detection and quantification limits of GC/FID and GC/MS methods were determined. Their values proved to be comparable for both methods. The experiments showed that determination of small concentrations of 3-NT in a large excess of the others is possible using both calibration curves and peak area i.e. in percentage terms.
PL
Opracowano procedurę ilościowego oznaczania mononitrotoluenów (MNTs) wykorzystując metodę GC/FID oraz GC/MS. Dla GC/FID uzyskano krzywe kalibracyjne w zakresie stężeń MNT 0,5-10 mg/ml. Dla GC/MS nie dopasowano wszystkich punktów kalibracyjnych metodą regresji liniowej. Dane te dopasowano metodą regresji nieliniowej. Dla uproszczenia oznaczeń ilościowych dane dla GC/MS dopasowano metodą regresji liniowej przy pomocy trzech krzywych kalibracyjnych. Wykorzystując parametry regresyjne wyznaczono granice wykrywalności i granice oznaczalności obu metod. Wartości tych granic, po uwzględnieniu niepewności pomiarowych, uznano za jednakowe. Badania wykazały, że oznaczanie niewielkich zawartości 3-NT w obecności nadmiaru pozostałych MNTs, wymaga odpowiedniego doboru stężeń próbek. Wtedy 3-NT można oznaczyć przy pomocy krzywych kalibracyjnych, jak i na podstawie procentowego udziału pól powierzchni pików MNT.
PL
W artykule omówiono bieżące regulacje prawne dotyczące poziomów emisji związków z grupy lotnych związków organicznych (LZO), a także sposoby ograniczania ich poziomów w instalacjach przemysłowych. Przedstawiono również metody analityczne stosowane najczęściej w celu analizy ilościowej i jakościowej związków z grupy LZO emitowanych z różnego rodzaju materiałów polimerowych. Dodatkowo omówiono nowe źródła związków z grupy LZO generowane w procesie druku 3D czy procesach recyklingu materiałów polimerowych. Dalszy rozwój procedur analitycznych służących do charakterystyki związków z grupy LZO oraz włączenie ich do kontroli jakości umożliwią podjęcie konkretnych działań w celu efektywnej minimalizacji emisji.
EN
The article discusses the current legal regulations regarding the levels of volatile organic compounds (VOCs) emissions as well as methods of their reduction in industrial installations. The analytical methods that have so far been most often used for the quantitative and qualitative analysis of VOCs emitted from various types of polymeric materials are presented. In addition, new sources of VOCs generated in the 3D printing process or the recycling of polymer materials are discussed. The further development of analytical procedures for the characterisation of VOCs and their inclusion in quality control will make it possible to take specific actions to effectively minimise emissions.
EN
Morphometric attributes of 705 stromatoporoid specimens from a number of exposures from the Silurian of Podolia (Ukraine) and the Devonian of the Holy Cross Mountains (Poland), representing a wide array of shallow water carbonate sedimentary environments, have been analysed. Taken into account were such parameters as: general shape of the skeleton, shape of the final growth form (living surface profile), upper surface character, latilaminae arrangement, burial ratio and type of initial surface. A number of new ratios has been introduced, designed mainly to improve the mapping of the outlines of the stromatoporoids upper surfaces. All studied specimens were treated as belonging to one group, and relations between particular attributes were tested. The results were analysed in terms of potential environmental factors influencing stromatoporoid morphometric features. Most of the distinguished attributes are common in the studied group and occur in various combinations, with an important exception of parameters designed to reflect the shape of the skeleton’s upper surface, which are distinctly predominated by convex variants. This indicates that surface concavity was a highly undesired feature among stromatoporoids. Upper surface convexity is interpreted herein as a response to the hazard of clogging of the animals pores by tiny sediment particles suspended in the bottom turbid water layer. Common low burial ratios of final living surface profiles and the occurrence of specimens with a smooth upper surface but a non-enveloping latilaminae arrangement are other reflections of this phenomenon. Burial by sediments and redeposition were also important factors governing stromatoporoid development. No direct arguments indicating photosensitivity of stromatoporoids can be deduced from the presented results. The hitherto postulated allometric tendency among stromatoporoids of starting growth as laminar forms and later adopting consecutively higher profile shapes has not been confirmed here. On the contrary, a tendency for gradual elimination of very high profile forms with increasing stromatoporoid size has been observed. The final shape of a stromatoporoid skeleton was always an effect of a combination of various agents.
EN
In the paper, the effect of vibro-compaction in processing of sintered SiCp – aluminium matrix composite was presented. The composite with 15% vol. of SiCp, obtained with three stages: vibro-compaction with use of different amplitude (0.75 mm, 1.125 mm and 1.5 mm), cold pressing and pressure less sintering. The obtained composites were characterized by porosity measurements, microhardness, quantitative metallography analysis and dry sliding tests. It was proved that the application of chosen compaction method, for powder mixture consisting of powders with different density (Al and SiC), allows to obtain graded structure composite. An increase of SiC particles volume fraction as well as microhardness increase was observed towards the bottom of the sample. The most beneficial effect, in SiCp distribution and microhardness values, was noted for the sample were the amplitude of vibro-compaction was 1.5 mm. Moreover, the tribological examinations showed differences in friction coefficients and mass losses for opposite surfaces of composite samples, due to different SiCp volume fraction across the sample. The vibro-compacted material revealed lower porosity, higher mean value of friction coefficient and lower mass loss comparing to the reference composite.
PL
Głównym obszarem zastosowania kompozytów na osnowie aluminium zbrojonych cząstkami ceramicznymi są skojarzenia ślizgowe i cierne, takie jak grupa tłokowo-cylindrowa maszyn tłokowych i łożyska ślizgowe, a w przemyśle samochodowym klocki hamulcowe, sprzęgła, przekładnie pasowe czy bloki silnika. W wielu elementach nie są wymagane takie same właściwości tribologiczne materiału na całym przekroju lub nie jest technologicznie możliwe uzyskanie ekstremalnie wysokich parametrów użytkowych związanych z dużą zawartością cząstek w całej objętości. W takich przypadkach rozwiązaniem mogą być materiały charakteryzujące się gradientowym rozmieszczeniem cząstek ceramicznych i istnieje wiele koncepcji technologicznych pozwalających uzyskać ten typ mikrostruktury. W pracy przedstawiono możliwość uzyskania metodą metalurgii proszków struktury gradientowej w kompozycie Al–SiCp, dla udziału zbrojenia w mieszaninie wyjściowej 15% obj. Założono, że gradientowe zróżnicowane rozmieszczenie zbrojenia w osnowie powstanie dzięki różnicy gęstości komponentów (Al 2,7 g/cm3, SiC 3,21 g/cm3), podczas zgęszczania wibracyjnego, dzięki bardziej intensywnemu w porównaniu z proszkiem aluminium przemieszczaniu się cząstek SiC w dół formy.
PL
Badania ukierunkowano na analizę ilościową mikrostruktury betonów osłonowych, zmodyfikowanych przez zastosowanie kruszywa magnetytowego oraz dodatków zawierających moderatory neutronów prędkich i absorbenty neutronów termicznych w celu poprawy osłonowości przeciw promieniowaniu neutronowemu. Do opisu mikrostruktury tych betonów wykorzystano metodę komputerowej analizy obrazu, za pomocą której wyznaczono parametry stereologiczne. Wyniki analiz statystycznych wykazały, że zmiana mikrostruktury betonów magnetytowych ma wpływ na ich wytrzymałość na ściskanie i właściwości osłonowe.
EN
The use of the quantitative image analysis to evaluate a microstructure and study its relation with characteristics of building composites is still growing. The aim of the paper was to quantitatively describe the microstructure of the magnetite concrete, modified by materials containing fast neutron moderators and thermal neutron absorbers, to increase its shielding properties against neutrons. The computer image analysis method was used to calculate the stereological parameters. The results of the statistical analysis showed that the change in the magnetite concrete microstructure influenced their compressive strength and shielding properties.
PL
Poprzez badanie proteomu i tego, w jaki sposób się zmienia, można uzyskać informacje o tym, jak funkcjonuje dany organizm.
PL
Pozakomórkowa ekspresja białek jest znaczącą oraz ciągle rozwijającą się technologią. W przyszłości zdolność do manipulowania warunkami reakcji pozwoli z pewnością na tworzenie nowych, zróżnicowanych zastosowań omawianej techniki.
EN
SimiaoYong'an decoction, a traditional Chinese medicine formula consisting of four herbs, has been widely used for the treatment of gangrene disease. However, its clinical application is restricted due to the lack of an effective quality control method that covers the main active compounds in the formula. In this study, a high-performance liquid chromatography with diode-array detection (HPLC–DAD) method was established for the simultaneous determination of 13 active compounds including harpagide, neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, ferulic acid, isochlorogenic acid B, isochlorogenic acid A, isochlorogenic acid C, angoroside C, harpagoside, cinnamic acid, glycyrrhizic acid, and ligustilide. Separation of these compounds was achieved using a Kromasil 100-5-C18 column with a gradient elution program consisting of acetonitrile and 0.4% phosphoric acid solution. The specificity, linearity, precision, repeatability, and accuracy tests were implemented to validate the method. The validated method was successfully applied for determination of 13 components from several finished batches of SimiaoYong'an decoction. The results demonstrated that the established method was accurate, reliable, and could be used as a suitable quality control method for the quantification of SimiaoYong'an decoction.
EN
Diabetes mellitus and concurrent hypertension disorder are dreadful all over the world and are often managed by some drugs, such as metformin hydrochloride (MFH), enalapril maleate (ENM), and captopril (CAP). In this work, a reliable and fast quantitative analysis of these three components in tablets was carried out by Tchebichef image moment method and multivariate curve resolution with alternating least squares on three-dimensional (3D) spectra obtained by high-performance liquid chromatography coupled with photodiode array detection (HPLC-PAD). 3D spectra were obtained within only 2 min, and linear quantitative models were established by stepwise regression based on the calculated image moments. Among these two methods, Tchebichef image moment method showed outcome distinction. The correlation coefficients of cross-validation (RLoo-cv) are more than 0.988, while their recoveries are 100.1 ± 1.7% (MFH), 95.4 ± 5.4% (ENM), and 105.3 ± 5.7% (CAP), respectively. The intra- and inter-day precisions (RSD) are less than 5.42%. The proposed methods were also applied to the analysis of real tablets. This study reveals the effectiveness and convenience of the proposed image-moment method that may be a potential technology for the quality control and investigation of drugs in routine analysis.
EN
A reliable and rapid high-performance liquid chromatography coupled with diode array detector method (HPLC–DAD) was established and validated to determine eight gingerol simultaneously in the rhizomes of Zingiber offcinale Rosc. The separation of eight compounds (4-hydroxy-3-methoxy-benzenebutanol,3,5-dihydroxy-1-(4-hydroxy-3-methoxyphenyl) decane, 3,5-dihydroxy-1-(3,4-dimethoxyphenyl) decane, 6-gingerol, 8-gingerol, 6-shogaol, 5-hydroxy-1-(4-hydroxy-3-methoxyphenyl)-1,4-decadien-3-one, and 10-gingerol) were performed on an Agilent TC(2) C18 (250 mm × 4.6 mm, 5 μm) at 30 °C using acetonitrile (A) and 1% formic acid aqueous solution (B) as the mobile phase with gradient elution (0–10 min, 20%–35% A; 10–28 min, 35%–55% A; 28–35 min, 55%–60% A; 35–55 min, 60%–70% A; 55.01–60 min, 100%–100% A). The detection wavelength was set at 280 nm, and the flow rate was 0.8 mL/min. Validation of the analytical method was performed by linearity, precision, and accuracy test. All compounds were quantified with good linear calibration curves (coefficient of determination R2, >0.9999). The method showed good precision with overall coefficients of variation between 0.56% and 0.84%. The range of recovery was from 95.50% to 104.14% for the analytes. This method was successfully applied to quantify eight gingerols in Z. offcinale Rosc from different regions in China, so it can provide quality assessment for this medicine.
18
Content available remote O uogólnianiu wyników analiz ilościowych w naukach o zarządzaniu
PL
W artykule omówiono problematykę uogólniania wyników analiz ilościowych z próby na populację, szczególną uwagę kierując na wykorzystanie metod wnioskowania statystycznego w naukach o zarządzaniu. Dyskusji poddano uwarunkowania i specyfikę procesu uogólniania wyników, losowe i nielosowe schematy doboru próby oraz różnice pomiędzy wynikami z próby oraz wynikami z populacji. Wyjaśniono źródło ryzyka popełnienia błędu na etapie wnioskowania statystycznego oraz omówiono jego prawdopodobieństwo. Zwrócono uwagę na możliwość uogólniania wyników z próby nielosowej na populację, ale w oparciu o prawdopodobieństwo subiektywne. Omówiono również problematykę uogólniania wyników w przypadku analiz mechanizmów ekonomicznych.
EN
The paper addresses a very important topic of the inference from a sample to population, with a special attention paid to the application of statistical methods of inference in management science. The conditions and specifies of inference. Random and non-random sampling techniques, the difference between results obtained from the population or from the sample as well as inference in the case of the studies on economic mechanisms are discussed. The source of an error corresponding to statistical inference as well as its probability are explained. The author addresses also the problem of the inference from a non-random sample to population with the application of subjective probability.
EN
Age-hardening provides one of the most widely used mechanisms for the strengthening of aluminum alloys. The age-hardening involves three steps: solution treatment, quenching and aging. The temperature of solution treatment and aging is very important in order to reach desired properties of castings. The optimum temperature of solution treatment and aging led to formation microstructural features in form which does not lead to decreasing properties, but increasing ones. The major micro-structural features in A 226 cast alloys which are responsible for increasing properties are: eutectic Si particles, Cu-rich phases, Fe-rich phases and porosity. The increase of properties depends on morphology, size and volume of microstructural features. In order to assess age-hardening influence on microstructural features in A226 cast alloys were used as possibilities of evaluation by means of image analysis. Quantitative analysis decelerate changes in microstructure includes the spheroidization and coarsening of eutectic silicon, gradual disintegration, shortening and thinning of Fe-rich intermetallic phases, the dissolution of precipitates and the precipitation of finer hardening phase (Al2Cu) further increase in the hardness and tensile strength in the alloy. Changes of mechanical properties were measured in line with STN EN ISO.
PL
W pracy zaprezentowano wyniki oznaczania zawartości węgla całkowitego oraz węgla wolnego w materiałach zawierających węglik krzemu, azotek krzemu i tlenoazotki krzemu. Otrzymane zawartości C wykorzystywano do oznaczenia zawartości SiC w badanych materiałach. Prezentowana metoda oznaczania SiC jest dużo szybsza od klasycznych metod analitycznych. Otrzymane wartości stężenia SiC porównywano z danymi z certyfikatów oraz z wynikami otrzymanymi metodą klasyczną. Poprawność stosowanej metody oznaczania zawartości SiC została potwierdzona. W celu oznaczenia zawartości pierwiastków cięższych od fluoru zastosowano metodę fluorescencji rentgenowskiej. Przedstawiono wyniki uzyskane dla certyfikowanych materiałów odniesienia.
EN
The results of total and free carbon determination in materials containing silicon carbide, silicon nitride and silicon oxynitrides have been presented. This method of SiC determination is much faster than the classical analytical method. The obtained C contents were used to determine SiC concentration in the examined materials. These concentrations were compared with certified values and concentrations obtained by the classical analytical method. The correctness of the method used to determine SiC content was proved. To determine the total concentrations of elements heavier than fluorine, X-ray fluorescence was used. The results obtained for certified reference materials have been presented.
first rewind previous Strona / 5 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.