Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pump efficiency
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Cascade and variable rotational speed control systems of sewage pumping stations are compared in this article. The range of pump efficiency variations and potential for breakdowns are adopted as criteria. A pumping station including two or three pumps is analysed. A control system at a variable rotational speed and maximum sewage level is presented. Properties of a cascade control system and a system at a maximum head of sewage are compared using the example of any pump performance chart.
PL
Sprawność pomp i sprawność układów jako zasób energetyczny. Rola sprawności w ograniczaniu degradacji środowiska. Kierunki działania. Chybione rozwiązania. Wpływ strat w armaturze. Przykłady.
EN
Trends and effects of modernisation.
PL
W artykule podjęto próbę oceny wpływu prędkości masowego przepływu czynnika przez kolektor na jego parametry eksploatacyjne wyznaczane na podstawie charakterystyki sprawności. Testy kolektora przeprowadzono w warunkach polowych metodą stanu ustalonego dla dwóch przepływów masowych wynoszących 1.0 dm3/min oraz 2.5 dm3/min. Uzyskane wyniki pomiarowe porównano z charakterystyką sprawności sporządzoną w warunkach laboratoryjnych.
EN
In paper presented impact of flow rate on the characteristic parameters of flat solar collector with are compute on the base characteristic of efficiency. The tests of flat solar collector was made in outdoor conditions in steady state method for two flow rate equal 1.0 dm3/min and 2.5 dm3/min. Results compare with characteristic of efficiency with was made in laboratory conditions.
PL
Ocena rozrzutu rzeczywistych wartości sprawności pomp i wniosek operowania gwarantowaną sprawnością minimalną w ofertach.
EN
A critical opinion on declaring the highest attainable efficiencies, and the conclusion to declare guaranteed efficiencies in tendering specifications.
EN
Selected systems for controlling the operation of water system pump stations are characterised. Dependencies defining the efficiency of a pump set are presented in consideration of pump and motor efficiency variations at variable characteristic curves of distribution. Pump and motor efficiencies at constant and variable rotational speeds are defined. A comparative analysis of water pumping energy consumption is carried out for the control systems under discussion, where the distribution characteristic curves describe irrigation systems.
EN
The article presents criterion of evaluating energy consumption of water pumping. The lower slope of pump efficiency characteristic curve was plotted for the case of: constant gain of rotational speed and variable gain rotational speed. The unified form of the lower slope of pump efficiency characteristic curve was defined for variable head. The right-side coefficient of pump efficiency correction was defined.
PL
W artykule przedstawiono kryterium oceny energochłonności pompowania wody. Wyznaczono charakterystyki opadającej części sprawności pompy dla przypadku stałej wartości przyrostu prędkości obrotowej, zmiennej wartości przyrostu prędkości obrotowej. Zdefiniowano ujednoliconą postać opadającej części charakterystyki sprawności pompy dla zmiennej wysokości podnoszenia. Zdefiniowano prawostronny współczynnik korekcji sprawności pompy.
EN
The article presents methods of evaluating energy consumption of water pumps. Pump characteristics during work at variable rotational speed and constant head are discussed. Characteristics of the upper slope of pump efficiency curve were determined for the cases of constant and variable growth of rotational speed. The left-sided coefficient of pump efficiency correction was defined.
PL
W artykule przedstawiono sposób oceny energochłonności pompowania wody. Omówiono własności pomp podczas ich pracy przy zmiennej prędkości obrotowej i stałej wysokości podnoszenia. Wyznaczono charakterystykę narastającej części sprawności pompy dla przypadków: stałej wartości przyrostu prędkości obrotowej oraz zmiennej wartości przyrostu prędkości obrotowej. Zdefiniowano lewostronny współczynnik korekcji sprawności pompy.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.