Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 14

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pressure sensors
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Purpose: The shoulder girdle is a complex system, comprised by a kinematic chain and stabilizers. Due to the delicate equilibrium and synchronism between mobility and stability, high external loads may compromise its physiology, increasing the risk of injuries. Thus, this study intends to fully characterize the effects of a rugby tackle on the shoulder’s anatomy and physiology. Methods: For the experimental procedures, a matrix of pressure sensors was used, based on the Teckscan® pressure in-soles, force plates, an isokinetic dynamometer and sEMG (surface electromyography). Results: The anterosuperior region of the shoulder girdle confirmed the highest pressure values during impact (100 kPa to 200 kPa). Also, the right and left feet performed a vertical peak force of 1286 N (1.4 BW) and 1998 N (2.21 BW), respectively. The muscular activity of the shoulder muscles decreased after performing multiple tackles. Conclusions: During a tackle, the clavicle, scapula, trapezius and acromioclavicular joint are the anatomical structures with higher risk of injury. Also, the strike force on the feet decreases for stability purposes. After performing multiple impacts the muscular activity of the trapezius and rotator cuff muscles decreases, which may lead, in the long-term, to instability of the shoulder and inefficiency of the scapulohumeral rhythm.
PL
W artykule przedstawiono budowę systemu do pomiaru rozkładu nacisku stopy na podłoże przeprowadzanego w warunkach naturalnych, poza laboratorium chodu. Omówiono dobór materiału na czujniki, budowę wkładki pomiarowej oraz program do analizy danych. uzyskane wyniki przedstawiono pod kątem ich zastosowania w ortopedii, neurologii i schorzeniach układu krążenia. uzyskane informacje o pacjencie są wystarczające aby opracowany w ITE system pomiarowy znalazł zastosowanie w diagnostyce medycznej. Jest tani w porównaniu z innymi urządzeniami dostępnymi na rynku, co pozwoli na szersze rozpowszechnienie go i prowadzenie samokontroli przez pacjentów. Ponieważ dane przekazywane są drogą radiową może on znaleźć zastosowanie w telemedycynie. Może także być zastosowany w sporcie.
EN
This article presents construction of the system for investigating foot plantar pressure in natural conditions, outside the laboratory. Sensor component, construction of the measuring insole and data analysis software are described. Obtained results are presented in terms of use in orthopedics, neurology and cardio-vascular diseases. Collected data are sufficient for using developed by ITE system in medical diagnostics. Device is inexpensive compared to the other devices what can make it more widely available and give possibility of self-control by a patient. Because the data are transmitted wirelessly, system can be used in telemedicine and for assessment of sport training process.
PL
W pracy przedstawiono metodykę badawczą związaną z oceną skuteczności oraz optymalizacji układów chroniących przed niszczącym wpływem wybuchu. Skuteczność ochrony zależy od wielu czynników między innymi od struktury i materiału, z jakiego zostały wykonane osłony, grubości poszczególnych warstw oraz ich wzajemnego położenia względem siebie. Wyniki prowadzonych w tym zakresie badań przyczynią się do opracowania konstrukcji osłon poprawiających bezpieczeństwo funkcjonariuszy służb mundurowych i specjalistów stosujących w pracy materiały wybuchowe oraz do ochrony szeroko rozumianej infrastruktury krytycznej.
EN
The paper presents a methodology of research related to the evaluation of the effectiveness and optimization of protection from the damaging effects of explosion and glaring effects of ammunition. The effectiveness of the protection depends on many factors inter alia the material from which the structure was made sheath, the thickness of the individual layers and their relative position to each other. This research will contribute to improving the safety of the uniformed services and professionals at work using explosives and to protect the broader critical infrastructure.
PL
Kompozyty polimerowe z dodatkiem nanomateriałów takich jak nanopłatki grafenowe (GNP) czy nanorurki węglowe (CNT) są nową grupą materiałów o dużych możliwościach zastosowania w elastycznej elektronice drukowanej. Nanostruktury węglowe użyte jako przewodzący i wzmacniający kompozyt wypełniacz w osnowie z roztworu polimetakrylanu metylu (PMMA) lub polifluorku winylidenu (PVDF) zostały nadrukowane technologią sitodruku na elastyczne podłoże foli PET i użyte jako warstwy aktywne w rezystywnych czujnikach nacisku. Autorzy przygotowali kompozycje past o różnej zawartości CNT i GNP, sprawdzając właściwości elektryczne i mechaniczne nadrukowanych warstw. W zależności od zawartości GNP i CNT nadrukowane warstwy posiadały różną rezystancję powierzchniową: 120 kΩ/□ - 1 MΩ/□. Rezystancja kontaktowa była mierzona pomiędzy elektrodami czujnika jako odpowiedź sensora na zmiany nacisku w zakresie 10 N - 14 kN.
EN
Features of new polymer composites based on nanomaterials such as graphene nanoplatelets (GNP) or carbon nanotubes make them an interesting opportunity with high possibility of application in printed and flexible electronics. By screen printing on flexible substrates, carbon nanomaterials (employed as a conductive and reinforcing phase in PMMA and PVDF vehicle resins) are used as an active layer in pressure sensors measuring contact resistance. Composite materials with different amount of GNPs and CNTs were prepared with sample resistance ranging from 120 kΩ/□ to 1 MΩ/□. Filler material and resin type proved to be determining factors for sensor sensitivity. By applying force change ranging from 10 N to 14 kN contact resistance between electrodes of the sensors was measured.
EN
Modern way of machines' exploitation, due to their high level of constructional complication, requires certain level of supervising. That supervising is generally reduced to detection of pre-failure states and evaluation of machines’ single elements or components condition. In the frame of development of the research capacity of the Mechanical Faculty of Maritime Academy in Gdynia, has been developed the Exploitation Decision Aid System for marine engines exploitation, based on existing test bed with the marine diesel engine Sulzer AL 25/30. Modernization of the engine, significantly extended research and measurement capacity, what has resulted with improvement of quality, extension of the span, and acceleration of carried out research and development works in the domain of safety of exploitation and diagnostics of marine power plants. Above stated investments enables also an extension of the range of research and expertise related to engines' failures and exhaust gases emission pollution, in relation to broad spectrum of implemented fuels. The goal has been achieved in the way of the test equipment modernization including: effective pressure sensors, high pressure fuel sensors, monitoring and visualization of the engine systems' parameters, electronic indictors adopted to continuous operation at all cylinders in the same time, and high class decision aid computer equipment.
EN
The man's movement possibilities depend on foot deformation. It can be estimated by foot pressure distribution investigations. Healthy foot is arched on internal side, what acts like shock absorber, softening jolts caused by walking. Largest values of pressure appear on heel and metatarsus. Insignificant values appears on medial arch, and its growth shows the foot extent deformation eg. flatfoot. Article presents measurement method of foot pressure on the ground by four-points shoe insole, developed by authors, which carl be placed in any sport footwear. The value of pressure was measured on heel, medial arch, metatarsus and hallux by recording values of generated voltage on sensors which were made of piezoelectric polymer PVDF thin film. Load resistance of measuring setup was 1014 Ω. Under the influence of mechanical strain, the sensor, which is made from piezoelectric polymer film with electrodes, acts like a self-charging capacitor. To conduct correct measurements, it is important to use restart circuit. Restart circuit ensures recovery to starting point after execution of each step, what prevents charge accumulation in capacitor and measurement results distortion.
PL
Możliwości ruchowe człowieka, w dużej mierze, zależą od stanu jego stopy. Ocenić go można, badając rozkład sil nacisku stopy na podłoże. Prawidłowo zbudowana stopa jest wysklepiona po wewnętrznej stronie, co działa jak amortyzator, łagodząc wstrząsy spowodowane chodzeniem. Największe wartości nacisku występują na pięcie i śródstopiu a nieznaczne na wklęśniętej części stopy, jego wzrost, świadczy o stopniu zdeformowania stopy np. przy płaskostopiu. W artykule omówiono sposób jego pomiaru przy pomocy opracowanej przez autorów czteropunktowej wkładki do obuwia, którą umieścić można w dowolnym obuwiu sportowym. Wielkość nacisku mierzono na pięcie, wklęśniętej części stopy, śródstopiu i dużym palcu, rejestrując napięcia wytworzone na czujnikach z piezoelektrycznej folii polimerowej z PVDF. Rezystancja obciążenia układu pomiarowego wynosiła 1014 Ω. Ponieważ czujnik pomiarowy z piezoelektrycznej folii polimerowej z elektrodami jest samoładującym się kondensatorem pod wpływem odkształceń mechanicznych a także wykazuje właściwości piroelektryczne, bardzo ważną rolę w prawidłowym przeprowadzeniu pomiarów, odgrywa układ zerujący. Zapewnia on powrót układu pomiarowego do punktu wyjścia po wykonaniu każdego kroku, zapobiegając zniekształceniu wyników pomiarowych.
EN
The paper presents the results of the investigation into fl exible layers based on carbon nanotubes used as measuring layer in forcesensor. Results of mechanical fatigue tests show that carbon nanotubes layers are good for reinforcing or as a conductive additive in composite materials. Composition of carbon nanotubes in PMMA polymer resin was prepared by modifi ed mixing process used in thick film material preparation. Sensor structure was fabricated by printing polymer-nanotube areas with polymer-silver paths as connection electrodes on polyester substrate foil. Second type of sensors was prepared with two comb electrodes and single carbon measuring layer. Composite materials were fabricated with diff erent amount of nanotube content: 0,25 wt%, 0,5 wt%, 1 wt% and 2 wt% multiwall carbon naotubes (MWCNT). Diff erent types of carbon-composites measuring layers were compared in the experiment. Results of mechanical fatigue tests conducted on carbon nanotubes layers showed that composition with polymer resin have good adhesion to polymer surface. Experiment shows CNT are good for reinforcing or as a conductive additive in diff erent composite materials. Results of the observations show that dependence between sensor resistance and force tension is linear in logarithmic scale and similar for diff erent samples. Resistance between sensor electrodes was measured for force tension changes in range.
8
EN
Optical chemical sensors enlarge the definition of a classical chemical sensor; they present results in two-dimensional (2D) or three-dimensional (3D) aspect. They can determine parameters of micro and macro scale objects without using a lot of electronic equipment. This article is focused on sensors based on porphyrin derivatives and europium complexes, being the most frequently used substances sensitive to oxygen concentration, pressure and temperature changes. Along with the presentation of characteristics of substances employed to sensors’ construction, also the general principle of luminescent sensors operation, composition and operation range of selected mono- and bifunctional luminescent sensors are described; moreover the selected achievements, such as the “traffic light” sensor are shown.
EN
The paper analyzes the factors influencing the quantity and quality of diagnostic information obtained by engine indication with electronic indicators and pressures analyzers. Amount of information obtained virtually unchanged since the advent of the first construction pressure analyzers produced by Autronica and ABB Company. In many cases, the value of the maximum combustion and compression pressures, can be measured using these devices with sufficient accuracy and reliability, is if ignition occurs after piston TDC. Determination of the mean indicated pressure, compression ratio and heat release characteristics required to develop a method of TDC determination on the indicator diagrams, generate reliable angular axes in real time and pressure sensors of sufficient accuracy. It should be noted that in the latest solution of ABB system, a correction of thermodynamic loss angle and combustion pressure sensors of high accuracy were introduced. For marine diesel engines diagnosis, the pressure sensor measuring sustainability is important because of the ability to create trends of specific diagnostic parameters, which may constitute an additional, important source of diagnostic information. The paper presents an overview of currently available pressure sensors that can be used during marine engines indication. Most important issues related to the pressure measurement on indicator valves were characterized. An assessment of the gas channels and the quality of the angular axis impact for the parameters of indicator graphs was done.
PL
Przedstawiono wyniki badań nad opracowaniem rodziny kompozycji polimerowych z nanorurkami węglowymi do zastosowania w produkcji czujników technikami drukarskimi. Przebadano wpływ zawartości nanorurek węglowych w kompozycjach polimerowych na właściwości elektryczne warstw nanoszonych sitodrukiem oraz przydatność do zastosowania ich w produkcji czujników temperatury i nacisku. Kompozycje te przeznaczone są do zastosowania w produkcji układów elektroniki drukowanej na podłożach elastycznych, gdzie kluczowym aspektem jest uzyskanie wysokiej wytrzymałości na naprężenia mechaniczne oraz cykliczne naprężenia zmęczeniowe. W przypadku pomiarów temperatury w zakresie 5-273 K istotne jest również utrzymanie stabilności rezystancji przy zmiennych cyklach wzrostu i spadku temperatury. Kompozycje o zawartości od 0,1 do 1% nanorurek pozwalają na wytworzenie warstw o zakresach rezystancji 103-106 Ω, adekwatnych do zastosowania w rezystancyjnych układach pomiaru temperatury. Możliwość nadrukowania dowolnego wzoru pozwala na wytworzenie czujników nacisku dostosowanych do powierzchni, dla których ma być dokonywany pomiar, upraszczając procedurę i zwiększając dokładność.
EN
Paper presents results of experiments related to fabrication of polymer compositions filled with carbon nanotubes. This type of materials were used for production of printed electronics sensors, which is a new trend in production of electronic devices and circuits for elastic and disposable electronics. Nanotube amount in compositions was evaluated in relation to electric properties of screen printed layers. Obtained polymer-nanotube layers demonstrate favourable electrical properties and high mechanical durability, what inspired authors to use that potential in production of various types of sensors including temperature and pressure sensors. Compositions are optimized for production of printed electronics elastic structures where key aspect is to obtain highly durable layers especially resistant to mechanical fatigue. Low temperature (5-273 K) measurements demands to preserve measurement stability in cyclical temperature drops and raises. Specially developed pattern of screen printed silver paths and carbon nanotube areas was fabricated for pressure measurement through contact resistance changes. It is widely used method in application such as electronic foil keypads, potentiometers or pressure sensors. Investigated samples demonstrated over thousandfold change in measured contact resistance. This is way above resistance changes measured for other carbonic filling material such as fine grained graphite or carbon black. Compositions with 0.1-1 wt.% of carbon nanotubes allows to fabricate conductive layers with resistance range 103-106 Ω adequate for resistive temperature sensors. By special manufacturing technology and thermal processes stable and linear characteristics were obtained. By employment of carbon nanotubes as the active material, parasitic tensometric effects were eliminated. Ability to print various patterns allows to manufacture sensors adjusted to complicated shapes of objects, what makes measurements more precise. This type of sensors can meet the conditions of elastic skin temperature sensors for textronic applications.
EN
The engine-compressors GMVH types are used in the national gas transmission system in Poland. There is a danger of scuffing of the working components of the engine-compressor particular pistons and cylinders during the process of their exploitation. The growth of resistance in motion parts of the machine is the main symptom of the scuffing. In the cinematic system of the engine-compressor where the engine and compressor are fully mechanically integrated it is impossible to assess the power of mechanical friction without stopping the machine. But if the engine-compressor is equipped with a cylinder pressure measuring system it is possible to determine the indicated power of all compressor and engine cylinders and assess the friction losses as a difference between the sum of the engine 's cylinder s indicated power and the sum of the compressor's cylinders indicated power. In the differential measurements of absolute values measuring errors are accumulated so considerable uncertainty of the measured parameter is expected. The accuracy of the friction power losses assessment method is not sufficient for research purposes. However, despite the expected significant errors, assessed parameters trends observation should allow to detect ofrapid changes of machine technical condition caused by piton scuffing. To ensure the sense of this method a precise measurements and in particular the error consistency of indicated pressure assessment of all cylinders in long time period are necessary. The experience from engine-compressors monitoring and diagnostic system services, the main sources of errors and methods for their minimization are described in the paper.
EN
Polymer composites with carbon nanotubes (CNT) are new group of materials with a broad possibilities of application perspectives in many branches of the industry. In presented papers authors are investigating properties of sensor structures used in pressure sensor systems with CNT layers fabricated using thick film technology. One of the main difficulties to overcome was preparation of polymer-nanotube composition sample. Composition of carbon nanotubes in PMMA-PBMA polymer resin was prepared by modified mixing process used in thick film material preparation. Sensor structure was fabricated by printing polymer-nanotube areas with polymer-silver paths as connection electrodes on polyester substrate foil. Four type of compositions with different content of CNT were prepared: 0.1%; 0.25%; 0.5%. For different CNT content in printed thick film layers, samples exhibited resistance was around 100 kΩ, 2 MΩ, 200 MΩ respectively. Dependence between sensor resistance and force tension is nearly linear and similar for all samples. Significant decrease of resistance under tension was observed, and changes in resistance were more symptomatic for samples with higher CNT content. Distinct time hysteresis was observed during resistance measurements.
PL
Kompozyty polimerowe zawierające nanorurki węglowe (CNT) stanowią nową grupę materiałów o szerokim zakresie zastosowań w wielu gałęziach przemysłu. Poniższa publikacja zawiera wyniki badań nad właściwościami grubowarstwowych struktur polimerowych zawierających nanorurki węglowe zastosowanymi jako czujniki nacisku. Jednym z głównych trudności napotkanych przy wytwarzaniu struktur pomiarowych było wytworzenia polimerowo-nanorurkowej kompozycji grubowarstwowej. Przy zastosowaniu specjalnie dostosowanej techniki mieszania udało się wytworzyć kompozycję opartą o żywice PMMA-PBMA. Układ pomiarowy został naniesiony na podłoże polimerowe techniką sitodruku zarówno w przypadku polimerowo-nanorurkowych obszarów czujnika jak i polimerowo-srebrowych kontaktów pomiarowych. Do badań wykorzystano cztery rodzaje kompozycji zawierające odpowiednio 0.1%, 0.25% i 0.5% wagowo nanorurek które po nadrukowaniu wykazywały rezystancję ścieżek na poziomie 100 kΩ, 2 MΩ i 200 MΩ. Zależność pomiędzy zmianami siły nacisku a zmianami rezystancji okazała się niemal liniowa dla wszystkich próbek. Zaobserwowano znaczące zmiany w rezystancji pod wpływem siły nacisku które były bardziej znamienne dla próbek o dużej zawartości nanorurek. Zaobserwowano również histerezę zmian rezystancji dla wszystkich próbek.
PL
MAX1452 jest analogowym procesorem do kondycjonowania sygnału z czujników piezorezystancyjnych w tym do kompensacji temperatury. Służą temu celowi 4 przetworniki cyfrowo-analogowe sterowane cyfrowo, które korygują czułość i zero w funkcji temperatury. W sytuacji, gdy błędy temperaturowe są początkowo duże i nieliniowe, to najlepsze rezultaty daje stosowanie dwuetapowej procedury doświadczalniej kompensacji: najpierw kompensacja składowych quasiliniowych błędów, a dalsza poprawa za pomocą tzw. kompensacji schodkowej. Ze względu na szumy pomiarowe celowym jest, aby eksperyment do identyfikacji potrzebnych modeli obejmował pewien nadmiar pomiarów w stosunku do liczby wyznaczanych współczynników. W artykule pokazano przykładowe wyniki kompensacji temperaturowej czujnika ciśnienia o zakresie 100 kPa.
EN
MAX1452 is an analog processor for conditioning of the piezoresistive sensor signal and for the temperature compensation. To this purpose applied four digitally controlled analog to digital converters DAC, which sensitivity and offset are correcting as the function of the temperature. In the situation, when temperature errors are at first big and non-linear therefore applying the two-stage experimental procedure is giving the best results of compensation: in the first stage compensation for linear components of errors, but the more further improvement behind the help of the multislope compensation. On account of measuring noises it is intentional so that identification experiment of the models needed for the compensation contains certain excess of measeruments in relation to the number calculated coefficients. In the article results of the temperature compensation were shown for the pressure sensor with the span of 100 kPa.
14
Content available remote Wpływ układów jezdnych wybranych maszyn na glebę
PL
Analizowano wpływ przejazdów maszyn na glebę oraz uszkodzenie systemu korzeniowego świerka. Stanowisko znajdowało się na pseudoglejowej glebie średniozwięzłej i badania wykonano w korzystnych warunkach wilgotnościowych. Pod wpływem przejazdów nastąpiło zagęszczenie gleby do głębokości 0,20 m - porowatość zmniejszyła się o 5% objętościowych, a pojemność powietrzna o ponad 5%. W koleinach znacznie wzrósł opór penetrometryczny. Ci śnienie pod kołami maszyn, mierzone w glebie czujnikami ciśnienia ułożonymi na głębokości 0,1 m, kształtowało się na poziomie od 0,09 do 0,1 MPa na obszarach wolnych od pozostałości pozrębowych, zaś na powierzchniach pokrytych w zakresie 0,03-0,07 MPa.
EN
Effects of the forwarder's passage on soil and damage to root systems of spruce along an extraction trail were studied. The site was characterized by pseudogley type medium-textured soil under favourable moisture conditions. Due to the passages, soil compaction occurred to a depth of 20 cm, soil porosity decreased by 5% (in volume) and soil aeration decreased by more than 5%. Substantially higher values of soil penetrometric resistance were obtained in the rut after passages. Pressure conditions measured by sensors placed at a depth of 0.10 m below the soil surface, reached values ranging from 0.09 to 0.1 MPa on uncovered surface and 0.03 to 0.07 MPa on plots covered with slash.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.