Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 1

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  predictor LimA
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Noise mapping is a well-established practice among the European nations, and it has been follow for almost two decades. Recently, as per guidelines of the Directorate General of Mines Safety (DGMS), India, noise mapping has been made mandatory in the mining expanses. This study is an effort to map the noise levels in nearby areas of mines in the northern Keonjhar district. The motive of this study is to quantify the existing A-weighted time-average sound level (LAeq, T) in the study area to probe its effects on the human dwellings and noise sensitive areas with the probability of future development of the mines, roads, and industrial and commercial zone. The LAeq, T was measured at 39 identified locations, including industrial, commercial, residential, and sensitive zones, 15 open cast mines, 3 major highways, and 3 haulage roads. With the utilisation of Predictor LimA Software and other GIS tools, the worked out data is mapped and noise contours are developed for the visualisation and identification of the extent and distribution of sound levels across the study area. This investigation discloses that the present noise level at 60% of the locations in silence and residential zone exposed to significantly high noise levels surpasses the prescribed limit of Central Pollution Control Board (CPCB), India. The observed day and night time LAeq, T level of both zones ranged between 43.2–62.2 dB(A) and 30.5–53.4 dB(A), respectively, whereas, the average Ldn values vary between 32.7 and 51.2 dB(A). The extensive mobility of heavy vehicles adjoining the sensitive areas and a nearby plethora of open cast mines is the leading cause of exceeded noise levels. The study divulges that the delicate establishments like schools and hospitals are susceptible to high noise levels throughout the day and night. A correlation between observed and software predicted values gives R2 of 0.605 for Ld, 0.217 for Ln, and 0.524 for Ldn. Finally, the mitigation measure is proposed and demonstrated using a contour map showing a significant reduction in the noise levels by 0–5.3 dB(A).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.