EN
Transformerless inverters are widely used in different photovoltaic nonisolated ac module applications, mainly in grid-tied photovoltaic (PV) generation systems, due to the benefits of achieving high efficiency over a wide load range, and low cost. Various transformerless inverter topologies have been proposed to meet the safety requirement of low ground leakage currents, such as specified in the VDE-4105 standard and low-output ac-current distortion. Topology modifications of transformerless full bridge inverters are designed to balance and maintain a constant common mode output voltage, thereby eliminating or reducing leakage currents. This article reviews and compares the different methods for limiting leakage currents in known topologies of the full-bridge transformerless inverters, such as: H4, H5, H6, HERIC, and their improvements. The main topologies and strategies used to reduce the leakage current in transformerless schemes are summarized, highlighting advantages and disadvantages and establishing points of comparison with similar topologies. To compare the properties of different medium to high power inverters, PV inverter topologies were implemented using IGBTs and tested with the same components, same simulation parameters in PSPICE to evaluate their performance in terms of energy efficiency and leakage current characteristics. The detailed power stage operating principles, extended PWM modulator, and integrated universal gate driver with galvanic isolation in the transmission path of control signal for all IGBTs of the inverter, as well isolated and floating bias power supply for gate drivers are described.
PL
Nowe amperomierze cęgowe prądu przemiennego CM4002 i CM4003 mierzą nie tylko niewielkie prądy upływowe, lecz również prądy stosunkowo duże płynące przez obciążenia
EN
Low voltage surge arresters work in a very different environmental conditions. During the exploitation, under the influence of environmental exposures, the structure of metal oxide surge arresters (MOSA) is gradually degraded. These processes can change their protective properties and lead to a reduction in the effectiveness of surge protection. The aim of the paper is to analyze the influence of environmental exposures on the electrical parameters of low voltage surge arresters.
PL
Warunki środowiskowe w jakich pracują niskonapięciowe ograniczniki przepięć są bardzo zróżnicowane. Podczas eksploatacji, pod wpływem narażeń środowiskowych, struktura ograniczników przepięć ulega stopniowej degradacji. Procesy te mogą powodować zmiany parametrów elektrycznych ograniczników i prowadzić do zmniejszenia skuteczności ochrony przeciwprzepięciowej. Celem referatu jest analiza wpływu narażeń środowiskowych na parametry elektryczne niskonapięciowych ograniczników przepięć.
EN
This work is focused on environmental pollution monitoring on selected high-voltage insulators. It is well known that environmental pollution on electrical insulation is one of the problems faced by distribution utilities and electricity transmission system. Due to this reason there is a need to deal with monitoring of environmental pollution as it strongly influences their capability to withstand the high-voltage stress without the breakdown. It is the aim of present work to explain influence of morphology and chemical composition of pollutants on the surface resistance and conductivity of selected insulators.
PL
W artykule przedstawiono wyniki prac dotyczących monitorowania zanieczyszczenia środowiska na wybranych izolatorach wysokonapięciowych. Powszechnie wiadomo, że zanieczyszczenie środowiska oddziałujące na izolację elektryczną jest jednym z problemów, z którymi borykają się przedsiębiorstwa dystrybucyjne i system przesyłu energii elektrycznej. Z tego powodu istnieje potrzeba monitorowania zanieczyszczenia środowiska które silnie wpływa na ich zdolność instalacji do pracy bez awarii. Celem niniejszego artykułu jest wyjaśnienie wpływu morfologii i składu chemicznego zanieczyszczeń na oporność powierzchni i przewodnictwo wybranych izolatorów.
PL
Powszechnie stosowane w instalacjach niskiego napięcia wyłączniki różnicowoprądowe (RCD), są urządzeniami ochronnymi zdolnymi wykryć niewielkie prądy upływowe, doziemne lub rażeniowe, ale w pewnych warunkach ich próg wyzwolenia może znacząco odbiegać od znamionowej wartości (np. 30 mA). Występowanie urządzeń energoelektronicznych w obwodach chronionych przez wyłączniki RCD, generuje powstawanie prądów różnicowych w szerokim zakresie częstotliwości. Częstotliwość podstawowa przebiegu jak również występowanie harmonicznych uwarunkowane jest wewnętrzną konstrukcją urządzeń, zamontowanych w chronionym obwodzie. Jeżeli wyłącznik RCD ma stanowić skuteczną ochronę uzupełniającą, szczególne znaczenie ma najmniejsza wartość prądu powodująca jego niezawodne zadziałanie.W artykule wykazano problemy związane z zastosowaniem typowych wyłączników RCD jako środka ochrony przeciwporażeniowej w tego typu obwodach.
EN
Commonly used in low voltage installations Residual Control Devices are the protective devices capable of detecting low leakage, ground or shock currents, but under certain conditions their trigger threshold may be significantly different from the nominal value, e.g., 30 mA. The existence of power electronics devices in the protected circuits results in generation of differential circuits in a wide range of frequencies. The fundamental frequency as well the existence of harmonics are determined by the internal design of the devices present in the protected circuit. If the RCD switch is to provide a reliable secondary protection, the lowest value of triggering current is crucial for this purpose. In the paper, the problems related to the application of typical RCD switches as an anti-shock protection means in such circuits have been investigated.
PL
W artykule omówiono wyniki pomiarów charakterystyk prądowo-napięciowych w zakresie prądu upływowego warystorowych ograniczników przepięć z tlenku cynku ZnO dla temperatur w zakresie 263 K ÷ 373 K. Badania wykonano w celu stwierdzenia powtarzalności charakterystyk ograniczników przepięć oraz obliczenia współczynników poprawkowych koniecznych dla przeliczania wyników pomiarów prądu upływowego na temperaturę odniesienia. Procedura taka jest konieczna podczas porównywania wyników badań wykonywanych w różnych warunkach zewnętrznych. Dla temperatur od 263 K do 323 K należy liczyć się nawet z dwukrotną zmianą prądu upływowego w stosunku do przyjętej temperatury odniesienia wynoszącej 293 K.
EN
The article discusses the results of measurements of current - voltage characteristics in terms of leakage current metal oxide surge arresters (ZnO) for temperatures in the range 263 K - 373 K. The study was performed in order to determine the repeatability characteristics of surge arresters and calculate the correction factors necessary for translating the results of measurements of the leakage current at the reference temperature. Such a procedure is necessary when comparing the results of tests performed in different external conditions. Effect of temperature on the leakage current is observed only for voltages not exceeding maximum continuous operating voltage. When performing measurements at temperatures ranging from 263 K to 323 K can be expected even with the double change of leakage current in relation to the reference temperature of 20oC. In addition, arresters with higher continuos operating voltage have a lower effect of temperature on the leakage current. There is a significant influence of the chemical composition of the varistor on the level of leakage current, and thus the value of the correction factor kT.
PL
Najpopularniejszym środkiem ochrony uzupełniającej stosowanym w instalacjach niskiego napięcia są obecnie wyłączniki różnicowoprądowe. Produkowane wyłączniki, konstrukcyjnie przeznaczone są do wykrywania prądów różnicowych sinusoidalnych o częstotliwości 50/60 Hz. W przypadku przebiegów odkształconych lub o innej częstotliwości, mogą nie reagować nawet na znaczne przekroczenie wartości znamionowego różnicowego prądu zadziałania. W tych warunkach może się okazać, że ochrona przeciwporażeniowa jest nieskuteczna.
EN
At present, the most popular means of subsidiary protection used in low-voltage systems are differential circuit breakers. Manufactured differential circuit breakers are designed and constructed for the detection of differential sinusoidal currents with a frequency of 50/60 Hz. In a case of distorted waveforms or different frequencies they may not respond even to a significant excess of the rated differential current operation. Under these conditions the shock protection may be ineffective.
PL
W artykule omówiono wykorzystanie rejestratora prądów upływowych Kyoritsu KEW 5001 w diagnostyce urządzeń i instalacji elektroenergetycznych.
EN
The paper presents features of KEW 5001 leek logger during control of electrical installation.
PL
Przedstawiono założenia systemu ochrony przeciwporażeniowej działającego w oparciu o znajomość cech charakterystycznych roboczych i uszkodzeniowych prądów upływowych.
EN
The paper presents design basis of electric shock protection system based on knowledge of characteristies of operational and failure state leakage currents.
PL
Wyjaśniono przyczyny zagrożeń wywołanych przerwaniem przewodu neutralnego w głównej rozdzielni elektroenergetycznej budynku mieszkalnego oraz przedstawiono sposoby zabezpieczeń przed skutkami takich awarii.
EN
The author explains reasons of hazards caused by interruption of neutral conductor in the main switching station of residential building and presents methods of protection against effects of such failures.
EN
This article describes methods of monitoring residual currents in earthed industrial networks. Shows residual currents relays and residual current monitoring system, which can be used to inform service department about dangerous situations. Describes basic parameters of such devices, which has to be considered before installation.
PL
Przedstawiono i omówiono pomiary prądów upływowych i różnicowych w instala-cjach elektrycznych z wyłącznikami różnicowoprądowymi oraz zaprezentowanoprzykłady błędnych połączeń obwodów. Nadmierne prądy upływowe bądź błędne połączenia obwodów magą powodować zbędne zadziałanie wyłączników różnicowoprą-dowych. Prawidłowa interpretacja wyników pomiarów rzeczywistych prądów róż-nicowych i upływowych jest podstawą oceny stanu ochrony przeciwporażeniowejinstalacji elektrycznej z wyłącznikami różnicowoprądowymi.