Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  prąd aktywny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Conductance control of a shunt active power filter and active energy buffer
EN
There are many types of control method for shunt active power filter (SAPF) investigated up until now. The authors describe complex methods of determining active filter reference currents or powers. This paper is dedicated to a simple, but universally used control algorithm based on the load equivalent conductance approach. This method allows for non-active current compensation, energy buffering, and energy redistribution among loads under compensation. It is also useful for voltage-source as current-source inverter based active filters, and for DC system as well as for AC single or three-phase filters.
PL
Zadaniem energoelektronicznego filtru aktywnego jest kompensacja prądu nieaktywnego w gałęzi źródła zasilania. Znanych jest wiele metod pozyskiwania informacji niezbędnych do skompensowania tego prądu. Często są to wyrafinowane metody, bardzo złożone zarówno pod względem pojęciowym, jak i obliczeniowym. W niniejszym artykule przedstawiono nieskomplikowaną, lecz wydajną i wielofunkcyjną metodę uzyskiwania wzorca składowej czynnej prądu obciążenia. Jest ona oparta na pojęciu konduktancji zastępczej obciążenia. Umożliwia nie tylko kompensację prądu nieaktywnego, ale również sterowanie przepływem energii czynnej, w tym jej rekuperację i redystrybucję do kompensowanych obciążeń. Opisana metoda może być stosowana w obwodach jedno- i wielofazowych, a także w obwodach zasilanych sygnałem stałym. Może też zostać użyta wobec filtru aktywnego opartego i na falowniku napięcia, i na falowniku prądu.
EN
This paper presents an analysis of Akagi's p-q theory for active filtering under nonsinusoidal voltage conditions. It is ascertained that compensating the alternative parts of the instantaneous active and reactive powers leads to a sinusoidal power supply current only under sinusoidal voltage conditions. A modified definition of the active component of the current is proposed for operation under nonsinusoidal voltage conditions and shunt active filter applications. A generic example and the full controlled rectifier-based DC motor drive system are used as case studies.
PL
Artykuł przedstawia analizę teorii p-q Akagi'ego, stosowanej do filtracji aktywnej w warunkach napięć niesinusoidalnych. Stwierdzono, że kompensacja składników oscylacyjnych mocy chwilowych, czynnej i biernej, prowadzi do sinusoidalnego prądu zasilania tylko w warunkach zasilania napięciem sinusoidalnym. Zaproponowano zmodyfikowaną definicję składowej czynnej prądu na potrzeby sterowania równoległego filtru aktywnego pracującego przy niesinusoidalnym napięciu zasilania. Prostownikowy napęd silnika prądu stałego został użyty w artykule jako przykład dla przedstawionej w artykule analizy.
3
PL
W artykule pokazano, że dziedzina czasu dyskretnego ujawnia wszystkie zjawiska energetyczne w obwodach elektrycznych, tj. rozkład prądu obwodu na prąd aktywny, prąd bierny i prąd rozrzutu.
EN
In the article was shown that the discrete-time domain approach makes identification of power phenomena in electrical circuit: the current distribution to physical components: active current, reactive current, scattered current.
PL
W artykule tym pokazano, że zarówno dziedzina częstotliwościowa jak i czasowa ujawnia wszystkie zjawiska energetyczne w obwodach elektrycznych, tj. rozkład prądu obwodu na prąd aktywny, prąd bierny i prąd rozrzutu.
EN
In the article was shown that the frequency domain and the time domain approach too makes identification of power phenomena in electrical circuit: the current distribution to physical components: active current, reactive current, scattered current.
PL
W artykule pokazano, że dziedzina czasu ujawnia wszystkie zjawiska energetyczne także w obwodach trójfazowych, tj. rozkład prądu odbiornika na prąd aktywny, prąd bierny i prąd rozrzutu i prąd niesymetrii.
EN
In the article was shown that the time domain approach makes identification of power phenomena in three phase electrical circuits: the current distribution to physical components: active current, reactive current, scattered current and asymmetrical current.
EN
The fuzzy mathematical programming as optimization technique in one-phase electrical circuits with nonsinusoidal periodical waveforms and linear loads has been presented in the paper. The solution (active current) is determined as crisp one (real numbers) in frequency domain. It is obtained in the numerical way. This optimization leads to determine the source currents with minimal RMS value when the power constraints don't have to be fulfilled strictly. The solution takes into consideration membership functions of power constraint and minimized RMS value of currents.
PL
W artykule przedstawione zostało zastosowanie rozmytego programowania matematycznego w optymalizacji jednofazowego obwodu elektrycznego ze źródłem napięcia okresowego odkształconego i liniowym odbiornikiem. Prąd aktywny jako rozwiązanie problemu otrzymywany jest jako rzeczywisty (nierozmyty) w dziedzinie częstotliwości w przypadku kiedy warunek mocy czynnej nie musi być spełniony dokładnie.
7
Content available remote Probabilistic representations of active currents
EN
An optimization method for active current determination in the case of systems with stochastic waveforms has been proposed in the paper. The active current for an ideal and non-ideal source-load system in which current is a normal stochastic process has been calculated. The results have been analyzed and their interpretation has been given. Theoretical considerations have been illustrated by an example.
PL
W artykule zaproponowano optymalizacyjną metodę wyznaczania prądów aktywnych w przypadku układów z przebiegami stochastycznymi. Rozpatrzono dwa przypadki - źródło jednofazowe idealne i nieidealne, zakładając, że prąd jest procesem stochastycznym normalnym. Wyniki zostały przeanalizowane i podano ich interpretację. Rozważania teoretyczne zilustrowano przykładem.
PL
Artykuł dotyczy układów N-fazowych (N+1)-przewodowych z sinusoidalnymi źródłami napięcia i bezinercyjnymi odbiornikami nieliniowymi. W modelu źródła napięcia zostały uwzględnione jego impedancje wewnętrzne. Rozwiązanie problemu oparte jest na dziedzinie częstotliwości. Prezentowana metoda może być stosowana dla układów z elementami bezinercyjnymi, które pobierają moc czynną dla podstawowej harmonicznej napięcia źródła, oraz w których prądy układu są okresowe. Wspomniana moc czynna stanowi dodatkowy warunek optymalizacji.
EN
The paper deal with the N-phases (N+1)-wire systems with sinusoidal voltage sources and inertialess nonlinear loads. In the model of the electrical network the parameters of transmission lines have been included. The solution of this problem is based on the frequency domain. This method can be used for systems with inertialess elements, which consume the active power of the basic harmonic of the voltage source and where the currents of the system are periodical. The above mentioned power is an additional condition of the presented optimization.
PL
Prezentowane problemy dotyczą układów N-fazowych N-przewodowych zasilanych z nieidealnych źródeł napięć okresowych odkształconych z asymetrycznym odbiornikiem połączonym w uogólniony trójkąt. W artykule przedstawiono metodę symetryzacji rozpatrywanych układów. Po symetryzacji prądy źródeł stają się symetryczne a ich wartości skuteczne i straty mocy czynnej na impedancjach źródła maleją. Ponadto po symetryzacji źródło generuje większą moc czynną. Symetryzacja realizowana jest za pomocą układu symetryzującego złożonego z dwójników LC.
EN
The presented problems concern a N-phase N-wire system with non-ideal periodical nonsinusoidal voltage sources with inner impedances and an asymmetrical linear N-phase generalized delta connected load. A method of symmetrization of these systems has been proposed. After symmetrization source currents become symmetrical and their RMS values and active power on source impedances become Iower. Moreover, the source generates greater active power than before symmetrization. The symmetrization of the system is obtained by means of connection of a symmetrizing system composed of LC one-ports.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.