Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 24

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pomiary akustyczne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The most commonly used measurement technique in room acoustics employs a single omnidirectional microphone for recording the room impulse response and further derivation of such acoustical parameters as T30, EDT, C50 or C80. Instead, ambisonic technology makes it possible to measure a spatial room impulse response. Ambisonics decomposes the signal from the spherical microphone array into spherical harmonics to shape the directivity. Ambisonics lets to go beyond basic acoustical parameters and allows to determine spatial features of a sound field at the measurement point. This study presents the comparison of fundamental acoustic parameters measured in the recording studio by an actual omnidirectional microphone and virtual omnidirectional microphones derieved from ambisonic microphones of the first and third order. The results show the usefulness of ambisonic technology in terms of assessing basic room parameters.
EN
The interaction of the wheel and rail is the main source of railway noise over a wide speed range. The relationship between wheel and rail noise on the overall level depends on the pass-by speed, with the dominance of noise from the rail at low speeds and the reverse relationship at higher speeds. Therefore, as part of the work the issue of analyzing the characteristic features of the acoustic signal generated on a selected section of the railway line from three different passenger trains TLK, Stadler and Pendolino was taken. The spectra of LEQ levels and their spread in 1/3 octave bands and spectral moments were adopted as the main distinctive features. The degree of aggregation of permanent features assigned to the track and variable features characteristic for passing-by trains were analysed. There were also tested their usefulness in the assessment of the impact of noise from wheels and rails on the overall level of railway noise from the tested units. The obtained results confirm the usefulness of the features based on the analysis of the spread of results in 1/3 octave bands in differentiating noise sources from rail and wheel, with slightly less usefulness of spectral moments.
PL
Interakcja koła z szyną jest głównym źródłem hałasu kolejowego w szerokim zakresie prędkości. Relacja pomiędzy wpływem hałasu od koła i szyny na poziom ogólny zależy od prędkości przejazdu, z dominacją hałasu od szyny przy niskich prędkościach i relacji odwrotnej przy prędkościach wyższych. Dlatego w ramach pracy podjęto zagadnienie analizy cech dystynktywnych sygnału akustycznego generowanego na wybranym odcinku linii kolejowej od trzech różnych jednostek - pociągów osobowych TLK, Stadler oraz Pendolino. Jako główne cechy przyjęto widma poziomów LEQ i ich rozrzuty w czasie przejazdu w pasmach 1/3 oktawy oraz momenty widmowe. Analizowano stopień agregacji cech stałych przypisanych do torowiska oraz cech zmiennych charakterystycznych dla przejeżdżających pociągów i ich przydatności w ocenie wpływu hałasu od kół i szyn na poziom ogólny hałasu kolejowego od badanych jednostek na danym odcinku. Otrzymane wyniki potwierdzają niezłą przydatność cech opartych o analizę rozrzutu wyników w pasmach 1/3 oktawy w różnicowaniu źródeł hałasu od szyny i koła, przy nieco mniejszej przydatności momentów widmowych.
PL
W pracy przedstawiono w zarysie ponad 40-letnią historię działalności Głównego Urzędu Miar w dziedzinie akustyki i drgań mechanicznych. Obecne możliwości GUM w zakresie zapewnienia spójności pomiarowej przedstawiono na tle potrzeb społecznych i gospodarczych Polski w tych dziedzinach. Wskazano obszary wymagające rozwoju na drodze prac badawczo-rozwojowych, zapisanych w strategii GUM.
EN
The paper outlines the over 40-year history of the activity of the Central Office of Measures in the field of acoustics and mechanical vibrations. The current GUM’s ability to ensure traceability is presented against the background of Poland’s social and economic needs in these areas. Areas that require development through research and development work, as enshrined in the GUM strategy, were indicated.
PL
W artykule przedstawiono wyniki pomiarów terenowych dotyczących poziomu dźwięków uderzeniowych przenikających do pomieszczeń mieszkalnych z pomieszczeń komunikacji ogólnej (podestów i biegów schodowych). Badania dotyczą wybranych układów pomieszczeń w budynkach wielorodzinnych i obejmują konstrukcję schodów wykonanych bez użycia elementów dźwiękoizolacyjnych oraz przypadek, w którym zastosowano takie rozwiązania. Na podstawie porównania uzyskanych wyników podjęto próbę oceny skuteczności rozwiązań wibroakustycznych oraz wpływu jakości robót wykończeniowych na stopień realizacji ochrony przed hałasem w pomieszczeniach mieszkalnych.
EN
The article presents the results of field measurements of sounds penetrating to residential spaces from general circulation areas (landings and flights of stairs). The measurements apply to selected layouts of rooms in multi-family buildings, comprising a stair frame built without soundproofing components, and a case study of practical application of such solutions.
PL
W artykule przedstawiono analizę pomiarów sygnałów akustycznych generowanych podczas testu pass-by wybranego typu lekkich pojazdów szynowych w warunkach normalnej eksploatacji. Pomiary hałasu wykonano zgodnie z wymaganiami normy ISO 3095. Celem analizy było sprawdzenie, w jakim stopniu uwzględnianie czasu przed i po przejeździe pojazdu przez punkt pomiarowy, ma wpływ na obliczanie ekspozycyjnego poziomu dźwięku A.
EN
The article presents the results of analysis carried out for automatization of analytical procedures for tram noise monitoring. The primary analytical procedures were developed based on the ISO 3095:2005 standard. However, it was decided to develop own research methodology. Due to, that fulfillment of all the requirements in strict urban area is impossible. The analysis of sensitivity symptom to different averaging data condition changes is presented in the comparative study. Also the possibility of its application in the vibroacoustic monitoring system of trams is proposed. There are the two main aims of the study. Firstly, checking the extent to which, the time before and after the passage of the vehicle through the measurement point, has an impact on the calculation of the exposure sound level A (SEL), on selected tram. Secondly, ensure if obtained characteristics can be considered as own, assigned to the type of vehicle. The study presents a part of research carried out in the Department of Rail Vehicles of University of Technology in Poznan, in terms of comprehensive description of the interaction of light rail vehicle – track in a highly urbanized environment. In this range, the crucial becomes an analysis of vibroacoustic activity of the tram, which is presented here.
PL
Hałas jako czynnik szkodliwy negatywnie wpływa na prace załóg statków. Zmienne miejsce pracy utrudnia ocenę narażenia na hałas. Rozwiązaniem jest dozymetria akustyczna oraz rekurencyjna metoda wyznaczania parametrów hałasu. Informacja dotycząca obciążenia hałasem pracownika jest istotna w ochronie zdrowia oraz ryzyka zawodowego. Przedstawiony w artykule system służy do zarządzania ryzykiem zawodowym na podstawie pomiarów akustycznych.
EN
Noise as a harmful factor has a negative impact on the work of crews. Changing workplaces during work complicates the assessment of exposure to noise. The solution to this problem is the acoustic dosimetry and recursive method of determining the parameters of the noise. Information concerning employee noise load is important in health and occupational risk. Presented in the article system is used to manage occupational risks based on acoustic measurements.
PL
Artykuł dotyczy badań modelowych wpływu oprzyrządowania pomiarowego na pole akustyczne w którym się znajdują. Przedstawiono wyniki dla dwóch obiektów różniących się kształtem, które są wymieniane jako możliwe do wykorzystania w charakterze urządzenia pozwalającego przemieszczać elementy toru pomiarowego.
EN
The paper concerns a model based research of an impact of a measurement equipment on the acoustic field it is located in. The results for the two objects that differ in shape, and both are possible to use as a device allowing to move the measurement path elements, are presented.
EN
The authors focus their attention on the identification of the probability distribution density function of the sound level, which constitutes the basis for the proper statistical inferences and uncertainty assessments in the environment acoustical hazard control. Their functional form is a metric for the analysis of acoustical measurement results burdened with random errors. Its proper selection conditions the rightness of statistical inferences in relation to the analysed noise effect. The problem of identification of the noise level probability distribution form was presented on the grounds of the sound LA level monitored at one of the main streets in Lublin. The analysis of differences and references to the normal distribution form, commonly applied to statistical analysis of the acoustical measurement results, was carried out. It is the aim of the authors, that the presented results should become the basis of a broader discussion concerning new estimation procedures of the controlled noise indicators and their uncertainty assessment. Also new verification procedures of the rightness of model acoustical formalisms, assumed in numerous environment acoustic investigations, are required.
XX
W artykule przedstawiono sposób estymacji funkcji gęstości rozkładu prawdopodobieństwa dla losowej próby wyników pomiaru poziomów dźwięku LA przesuniętym rozkładem gamma. Sformułowano potrzebę jej znajomości w kontekście środowiskowych akustycznych badań kontrolnych i związanych z nimi ocen ich niepewności. Dokonano analizy różnic i odniesień do postaci rozkładu normalnego, powszechnie wykorzystywanego w statystycznych analizach wyników pomiarów akustycznych. W zamierzeniu autorów zaproponowane rozwiązanie winno stać się podstawą szerszej dyskusji nad poszukiwaniami nowych algorytmów estymacji kontrolowanych wskaźników hałasu oraz ocen ich niepewności, a także procedur identyfikacji i weryfikacji akustycznych formalizmów modelowych przyjmowanych w badaniach
PL
Publikacja zawiera opis procedury projektowania trójdrożnego zestawu głośnikowego klasy hi-fi ze szczególnym uwzględnieniem pomiarów wykonanych z zastosowaniem metod cyfrowego przetwarzania sygnałów. W pracy opisano również zasadę działania stanowiska laboratoryjnego służącego do przeprowadzania pomiarów akustycznych, symulacji działania oraz komputerowego wspomagania projektowania zwrotnic pasywnych. Zaproponowana metoda pomiarowa pozwala na uzyskanie kompromisu pomiędzy wyrównanym przebiegiem charakterystyki poziomu ciśnienia akustycznego w funkcji częstotliwości a wyrównanym przebiegiem modułu impedancji w funkcji częstotliwości kompletnego zestawu głośnikowego.
EN
Article describes the procedure of designing a three-way high fidelity loudspeaker system with particular emphasis on measurements made with use of digital signal processing. This paper describes also the working principle of laboratory workstation used for the acoustic measurement, simulation and computer aided design of passive crossovers. The proposed measurement method allows to obtain a compromise between the aligned frequency response and aligned impedance response in complete loudspeaker system.
EN
The authors have made an attempt to construct a multi-channel data acquisition system for vibroacoustic signals, collected for analysis of acoustic field distributions in enclosed rooms and determination of surface acoustic impedance values at the wall surfaces. The scope of the study required a synchronic registration of acoustic pressure by 24 measurement microphones, determination of the phase-shift angles between the measured signals and determination of the vibration velocity for the loudspeaker diaphragm. The paper presents the first stage of the research, directly related to the multi-channel system for registration and analysis of vibroacoustic signals. The constructed research tools, due to their modular structure, can be adapted to new tasks, extended by adding new elements (further measurement cards, microphones, accelerometers etc.), what ensures greatflexibility and suitability of the system for realization of advanced acoustical measurements. Open source code and users request for specialized acoustic analyses make the developed software packages a highly prospective research tool both for today and tomorrow.
PL
Autorzy podjęli zadanie budowy wielokanałowego systemu akwizycji sygnałów wibroakustycznych na potrzeby analizy rozkładów pola akustycznego w pomieszczeniach i wyznaczania wartości impedancji akustycznej powierzchni ścian. Program badań wymagał synchronicznej rejestracji ciśnienia akustycznego przez 24 mikrofony pomiarowe, wyznaczenia kąta przesunięcia fazowego między mierzonymi sygnałami oraz wyznaczenia amplitudy prędkości drgań membrany głośnika. W pracy przedstawiony jest pierwszy etap badań bezpośrednio związany z wielokanałowym systemem rejestra­cji i analizy sygnałów wibroakustycznych. Zbudowano narzędzia, które dzięki modułowej strukturze mogą być dostoso­wywane do nowych zadań, rozszerzane o nowe elementy (kolejne karty pomiarowe, mikrofony, akcelerometry itp.), co stanowi o dużej przydatności powstałego systemu do zaawansowanych pomiarów akustycznych. Otwarty kod źródłowy oraz autorskie zapotrzebowanie na specjalistyczne analizy akustyczne tworzą z opracowanych pakietów programowych w pełni rozwojowe narzędzie badawcze na dziś i na przyszłość.
EN
The article presents a geometric model of a four axial manipulator intended for acoustic measurements in an anechoic chamber. The geometric model allows the development of a three dimensional computer model, a design of the construction of this device. The article presents the strultural solution for the device with the emphasis on the structure of the joint that allows the movement of the effector end with a fixed microphone. The developed geometric model allows the programming and automated positioning of the microphone related to the tested object at a given point of the measurement sphere. The possibility of positioning the microphone according to the straight or reverse model is presented. The technical and functional parameters of the solution described are adequate to specific conditions of operation in the anechoic chamber and high requirements stated for acoustic tests. The structure of the manipulator ensures a minimum influence of the measurement environment on the acoustic parameters.
PL
W artykule zaprezentowano system do wspomagania pomiarów akustycznych prowadzonych w komorze pogłosowej. Jego zadaniem jest pozycjonowanie próbek badanych materiałów rozpraszających dźwięk względem źródeł dźwięku i mikrofonów pomiarowych. Zaprezentowano konstrukcję mechaniczną urządzenia, zasadę sterowania nim oraz przykładowe wyniki pomiarów. Urządzenie zaprojektowano tak, aby jego wpływ na warunki akustyczne w komorze był jak najmniejszy.
EN
The article presents the system for automated acoustic measurements taken In an anechoic chamber Its task is to position the samples of tested sound dif-fusing materials related to the sources of sounds and the measurement microphones. The mechanical construction of the deyjce is presented as well as ttie principle of its control and the sample results of measurements. The design of the system is aimed at as little effect on the acoustic conditions in the chamber as possible.
PL
Prędkości propagacji fal akustycznych mierzone w nasyconych ośrodkach skalnych zależą m.in. od częstotliwości sygnału wykorzystywanego podczas pomiaru. Z tego powodu istnieją rozbieżności pomiędzy pomiarami wykonanymi przy użyciu sygnału o częstotliwościach sejsmicznych, akustycznych lub ultradźwiękowych. Jednak przyjmując pewne modele oraz dysponując pomiarami ultradźwiękowymi na rdzeniach można wyznaczać prędkości dla niższych częstotliwości. W pracy podjęto próbę wyznaczenia w warunkach laboratoryjnych prędkości propagacji fal podłużnych i poprzecznych na rdzeniach wiertniczych oraz odniesienie tych pomiarów do interpretacji opartej na pomiarach akustycznych wykonanych w otworach wiertniczych.
EN
Velocity of acoustic wave propagation measured in saturated rock depends on factors such as among others frequency used during the measurement. For this reason, there are differences between measurements performed using seismic, acoustic or ultrasonic signal frequency. However, assuming certain models and having the ultrasound measurements carried out on cores you can set the velocities for lower frequencies. The study attempts to determine in the laboratory propagation velocities of longitudinal and shear waves in cores and to make the results a comparison with the interpretation of acoustic measurements performed in boreholes.
PL
W pracy omówiono akustyczne aspekty wykorzystania kościoła pod wezwaniem Św. Marii Magdaelny we Lwowie do celów koncertowych. Przedstawiono wyniki pomiarów akustycznych oraz koncepcję poprawy jego walorów akustycznych jako sali koncertowej z wykorzystaniem doraźnie wstawianych do wnętrza elementów, rozpraszających dźwięk i poprawiających wzajemne słyszenie się wykonawców.
EN
The paper discusses acoustical aspects of musical activity in St Mary Magdalene church in Lviv. The concept of improving acoustical qualities of the church when employed as a concert hall is presented. Current acoustics of the church meets both liturgical and musical requirements as long as the convention of using it as a historical object is maintained.
PL
Przedstawiono badania wpływu ciśnienia statycznego na charakterystyki metrologiczne przyrządów pomiarowych wyposażonych w przetworniki nieelektrycznych wielkości wejściowych, ze szczególnym uwzględnieniem akustycznych przyrządów pomiarowych, kalibratorów, wzorców akustycznych i złożonych układów pomiarowych stosowanych w metrologii wielkości akustycznych. Omówiono zrealizowane w Głównym Urzędzie Miar stanowisko badawcze oraz metody wyznaczania współczynników ciśnieniowych wzorców akustycznych w szerokim zakresie częstotliwości. Przedyskutowano metody stosowane w Laboratorium Akustyki i Drgań do badania charakterystyk metrologicznych przyrządów pomiarowych zgłaszanych do zatwierdzenia typu. Wyniki badań własnych porównano z danymi deklarowanymi przez producentów przyrządów pomiarowych i wzorców akustycznych.
EN
This paper presents investigation of how the static pressure affects metrological characteristics of those measuring instruments, which comprise transducers of non-electric input quantities, in particular acoustic instruments, calibrators, acoustic standards and complex measuring systems employed in metrology of acoustic quantities. The testing system, designed and constructed at the Central Office of Measures (GUM) and methods for measuring pressure coefficients of acoustic standards in a broad range of acoustic frequencies are described. Investigations of metrological characteristics of measuring instruments submitted for type approval are discussed. Results of investigations performed at the Sound and Vibration Laboratory are compared with data declared by manufacturers of measuring instruments and acoustic standards.
PL
W pracy wytypowano kilka rozwiązań projektowych, dla których przewidziano w sposób teoretyczny, znanymi metodami, izolacyjność akustyczną wynikającą z założeń projektu oraz z przyjetych rozwiązań materiałowych- konstrukcyjnych. Następnie dla tych samych przegród, w warunkach rzeczywistych, pomierzono izolacyjność akustyczną wcześniej analizowanych przegród i porównano ją z obliczoną teoretycznie na etapie projektowania.
EN
In this paper several design solution were identified, for which, the known methods, acoustic insulation was predicted. This acoustic insulation due to the design assumptions and the solutions adopted materials. Then, for the same partitions, for real conditions, acoustic insulation was measured and compared to calculated theoretically.
PL
Praca omawia korektę akustyczną sali wykładowej, cechujacej się dużą pogłosowością i małą zrozumiało- ścią mowy. Sala znajduje sie w zabytkowym budynku. Przedstawiono wyniki pomiarów akustycznych oraz kroki zaradcze prowadzące do zwiększenia zrozumiałości mowy, z uwzględnieniem ograniczeń wynikających z historycznego charakteru sali.
EN
The paper presents the results of acoustical measurements in the lecture hall with excessively long reverberation time and low intelligibility of speech. The hall is situated in the monumental building. Acoustical correction of the hall has been discussed which takes into account limitations resulting from its historical value.
PL
W artykule przedstawiono sposób oceny stanu technicznego transformatorów po drugiej wojnie światowej, na podstawie "badań profilaktycznych" opartych o pomiary tzw. Wskaźników izolacji, oraz trudności, jakie wówczas występowały przy interpretacji wyników pomiarów. " Autor opisuje przejście od okresu obowiązywania przepisów o pomiarach profilaktycznych do wprowadzenia nowoczesnej diagnostyki technicznej transformatorów.
EN
The paper describes methods of transformer testing at side, after the second world war. The so called .preventive testing" based on measurement of insulation figures, from the beginning were criticized due to the weak basement to proper transformer condition judgment. Author presents evolution from the period of obligatory “preventive testing" practice to modem transformer diagnostic testing system.
PL
Zaprezentowano podstawy teoretyczne i zarys laboratoryjnej techniki pomiaru prędkości propagacji podłużnej i poprzecznej fali sprężystej w próbach okruchowych. Przedstawiono zalety i ograniczenia tej techniki oraz wyniki pierwszych pomiarów wykonanych na wybranych losowo 20 próbkach okruchowych. Wskazano możliwości wykorzystania wyników pomiarów w geofizyce, sejsmice i wiertnictwie oraz korzyści ekonomiczne wynikające z zastosowania tej metody pomiarowej.
EN
Presented are theoretical foundation and laboratory procedures of velocity determination of primary and secondary waves on drilling cuttings. The paper provides results for randomly selected 20 rock samples. Presented are advantages and disadvantages of this technique and possibilities of using the results in well logging, seismic soundings and drilling engineering.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.