Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 67

Liczba wyników na stronie
first rewind previous Strona / 4 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pojemność cieplna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 4 next fast forward last
EN
We have investigated pumpkin seed heat capacity influenced by the two factors of the heat agent temperature and the moisture content of the material. The difference between the heat of evaporation when drying pumpkin seeds in a differentiated microcalorimeter DMKI 01 from the tabular value is 6%. Increasing the temperature of the heat agent from 40 to 60°C reduces the drying process by 8 times, but the most appropriate is the drying mode at 40°C, under which the germination of pumpkin seeds is 98%. The study of heat and mass transfer during drying shows that active heat up process takes place at the beginning, then there is an intensive moisture evaporation from the material as evidenced by the value of the Rehbinder test, which is close to zero.
PL
Badano pojemność cieplną pestek dyni, na którą wpływają dwa czynniki: temperatura czynnika grzewczego oraz wilgotność materiału. Różnica pomiędzy ciepłem parowania podczas suszenia pestek dyni w zróżnicowanym mikrokalorymetrze DMKI 01 od wartości tabelarycznej wynosi 6%. Podwyższenie temperatury czynnika grzewczego z 40 do 60°C skraca proces suszenia 8-krotnie, ale najbardziej odpowiedni jest tryb suszenia w 40°C, w którym kiełkowanie pestek dyni wynosi 98%. Z badań wymiany ciepła i masy podczas suszenia wynika, że na początku zachodzi proces aktywne(go nagrzewania, następnie następuje intensywne odparowywanie wilgoci z materiału, o czym świadczy bliska zeru wartość testu Rehbindera.
PL
W artykule przedstawiono możliwości wykorzystania materiałów zmiennych fazowo jako przykład poprawienia zdolności akumulacji energii cieplnej wyrobów budowlanych, a także wyniki eksperymentu w zakresie oceny skuteczności działania materiału zmiennego fazowo w postaci mikrokapsułek Micronal®PCM firmy BASF, wprowadzonego w zróżnicowanej ilości do składu materiałów kompozytowych z matrycą gipsową i cementową. Oznaczono objętościową pojemność i przewodność cieplną w zmiennych warunkach temperaturowych, a także wykonano badania podstawowych parametrów technicznych analizowanych zapraw. Opisane rezultaty badań zaczerpnięto z prac dyplomowych, magisterskiej i inżynierskiej, zrealizowanych na Wydziale Budownictwa i Inżynierii Środowiska ZUT w Szczecinie.
EN
The article presents the possibilities of using phase changing materials as an example of improvement of thermal energy accumulation capacity of construction products, as well as results of an experiment regarding assessment of effectiveness of a phase changing material in the form of Micronal®PCM microcapsules, manufactured by the BASF company, introduced in varying amounts to the composition of composite materials with a gypsum and cement matrix. The volumetric capacity and heat conductivity were determined in changing temperature conditions, and the basic technical parameters of the analysed mortars were tested. The described research results have been taken from master's and engineer's dissertations, written at the Faculty of Civil and Environmental Engineering, at the West Pomeranian University of Technology in Szczecin.
4
Content available Solar collectors integrated into transparent facades
EN
Due to the fact that the number of natural disasters in the world has increased in recent years, experts note that climate change is the cause. As a consequence of the nature of the needs to improve the fuel and energy complex in the countries in world. This solution could be solar energy and similar energy sources. The paper presents the classification of energy-efficient houses proposed by international standards and its critical analysis. Emphasis is placed on the problem of improving solar collectors integrated into the construction of buildings. The paper presents the temperature characteristics of an experimental solar collector. For the experimental solar collector combined with the translucent facade of the building, thermal characteristics are set, in particular, such as thermal capacity and thermal efficiency.
EN
Standards related to calculation methods used in building energy performance simulation tools usually impose constant volumetric heat capacity of air. However, this simplification may result in errors if the actual conditions differ from the assumptions made. The paper presents the problem of dry air density and specific heat capacity variation and their influence on calculated energy use for space heating in a multifamily building. The monthly calculation method of PN-EN ISO 13790 was used. Simulations were performed in five cities, each in one climatic zone according to PN-EN 12831. Variation of the air density caused by air temperature and elevation resulted in differences in calculated heating demand from -4.5% to 4.5% in relation to that at constant volumetric heat capacity assumed in PN-EN ISO 13790.
6
Content available remote Stropy i sufity grzewczo-chłodzące o dużej pojemności cieplnej
PL
Celem artykułu jest analiza wpływu stropu aktywowanego termicznie i sufitu grzewczo-chłodzącego z wypełnieniem materiałem zmiennofazowym (PCM) na temperaturę powierzchni, temperaturę powietrza wewnętrznego oraz zapotrzebowanie na energię do ogrzewania i chłodzenia w pomieszczeniu biurowym, uwzględniając pojemność cieplną przegród i systemu grzewczo-chłodzącego. Scharakteryzowano stropy aktywowane termicznie i sufity grzewczo-chłodzące z wypełnieniem materiałem zmiennofazowym. Wykonano symulacje dynamicznych oddziaływań stropu i sufitu aktywowanego termicznie na warunki termiczne w pomieszczeniu i bilans energetyczny.
EN
The aim of the article was analysis of the thermally activated building system and heating/cooling ceiling system with phase change material (PCM) impact on the surface temperature, internal air temperature and energy demand for heating and cooling in an office room, taking into account the thermal capacity of construction and system. In this article was characterized thermally activated building system and heating/cooling ceiling system with phase change material. Based on the simple hourly method, simulation of the thermally activated building system and cooling – heating ceiling system influence on thermal conditions and energy balance in the office room were carried out.
EN
Due to the application of coil-shaped coils in a compressed gas flow exchanger and water pipe flow in airconditioner devices, air conditioning and refrigeration systems, both industrial and domestic, need to be optimized to improve exchange capacity of heat exchangers by reducing the pressure drop. Today, due to the reduction of fossil fuel resources and the importance of optimal use of resources, optimization of thermal, mechanical and electrical devices has gained particular importance. Compressed heat exchangers are the devices used in industries, especially oil and petrochemical ones, as well as in power plants. So, in this paper we try to optimize compressed heat exchangers. Variables of the functions or state-of-the-machine parameters are optimized in compressed heat exchangers to achieve maximum thermal efficiency. To do this, it is necessary to provide equations and functions of the compressed heat exchanger relative to the functional variables and then to formulate the parameter for the gas pressure drop of the gas flow through the blades and the heat exchange surface in relation to the heat duty. The heat transfer rate to the gas-side pressure drop is maximized by solving the binary equation system in the genetic algorithm. The results show that using optimization, the heat capacity and the efficiency of the heat exchanger improved by 15% and the pressure drop along the path significantly decreases.
PL
System stropów aktywowanych termicznie (TABS) w budynkach biurowych to rozwiązanie energooszczędne wykorzystujące masę termiczną budynku w celu stabilizacji temperatury odczuwalnej w zakresie komfortu cieplnego. Wpływ temperatury promieniowania powierzchni aktywnej na temperaturę operatywną oraz niskie parametry pracy instalacji HVAC umożliwiają zastosowanie odnawialnych źródeł energii. W artykule przedstawiono wyniki obliczeń wykonanych prostą metodą godzinową uwzględniającą dynamikę cieplną strefy budynku z systemem stropu aktywowanego termicznie oraz rozdział sposobu wymiany ciepła na drodze promieniowania i konwekcji (model oporowo-pojemnościowy 14R4C). Analizowane warianty posłużyły do oceny potencjału wykorzystania TABS dla różnych profili użytkowania pomieszczenia biurowego. Porównano analizowane warianty w aspekcie zapotrzebowania na energię do ogrzewania i chłodzenia oraz przedstawiono charakterystyczne cykle temperaturowe dla każdego wariantu.
EN
Thermally activated building system (TABS) in office buildings is an energy-saving solution which uses the thermal mass of the building in order to stabilize the operative temperature in terms of thermal comfort. The influence of radiation temperature of activated surface on operative temperature and low operating parameters of the HVAC system enables the use of renewable energy sources. The paper presents the results of calculations made with a simple hourly method taking into account the thermal dynamics of the building zone with a thermally activated building system and the separation of the heat exchange method by radiation and convection (the resistance-capacity 14R4C model). The analysed variants were used to assess the potential of using TABS for different usage profiles. The analysed variants were compared in terms of energy needs for heating and cooling and the characteristic temperature cycles for each variant were presented.
EN
The article describes a new method for obtaining fuel properties, derived from the thermal properties of natural gas fuel mixtures. By measuring the thermal conductivity and the dynamic response with the help of a heated Micro Electro Mechanical System (MEMS), input values for a mathematical correlation are obtained which predict the calorific value of the gas. In this paper the fundamentals of the theoretical gas properties, the sensor operation and the first results on a gas test bench are presented.
PL
Budynek jest efektem procesu inwestycyjnego, który łączy rozwiązania technologiczne, konstrukcyjne oraz instalacyjne, realizując w ten sposób potrzeby i oczekiwania inwestorów. Wspomniane rozwiązania mają na celu stworzenie mikrośrodowiska wewnątrz budynku, które będzie sprzyjać komfortowi ludzi w nim przebywających, a ponadto odpowiadają za jego wysoką efektywność energetyczną idącą w parze z minimalizacją oddziaływania na środowisko. Na rynku obok tradycyjnych murowanych technologii wznoszenia obiektów proponowany jest szereg nowatorskich rozwiązań, które najczęściej mają na celu ograniczenie zapotrzebowania na energię obiektu, kierując się w ten sposób stale zaostrzanymi przepisami dotyczącymi efektywności energetycznej w budownictwie. Jednym z takich rozwiązań są budynki prefabrykowane, które w 80% są produkowane w fabryce, a następnie montowane na placu budowy. Artykuł stanowi próbę porównania efektywności energetycznej budynku prefabrykowanego o szkielecie drewnianym i budynku w technologii tradycyjnej murowanej. W pierwszej części przedstawiono charakterystykę technologii wykonania obu obiektów. Następnie przeprowadzono analizę efektywności energetycznej budynków, aby w ostatniej części dokonać zestawienia oraz porównania otrzymanych wartości.
EN
The building is the result of an investment process that combines technology, construction and installation solutions, thus meeting the needs and expectations of investors. These solutions aim to create a microenvironment inside the building, which will be conducive to the comfort of people in it, as well as its high energy efficiency combined with the minimization of environmental impact. On the market, apart from conventional building technology, a number of innovative solutions are proposed. Most often, they aim to reduce the energy demand of the facility, guided in this way by constantly tightened regulations regarding energy efficiency in construction. One of such solutions are prefabricated buildings, which in 80% are produced in the factory and then assembled on the construction site. The article is an attempt to compare the energy efficiency of a prefabricated wooden frame construction and a conventional masonry building technology. The first part presents the characteristics of technology for both objects. Then an analysis of the energy efficiency of buildings was carried out, in order to compile and compare the obtained values in the last part.
11
Content available Accumulation of low-potential thermal energy
EN
The article presents interpretation of accumulation of thermal energy in a vertical borehole. It describes measuring device and final graph of measurement. It studies mainly the influence of water on storage capacity of the vertical borehole.
PL
Artykuł przedstawia zagadnienie magazynowania ciepła w pionowym odwiercie w gruncie. Przybliża on zastosowane urządzenia pomiarowe i schemat układu pomiarowego, a także analizuje wpływ wody na zdolności magazynowania ciepła w pionowym odwiercie.
PL
W publikacji zaprezentowano zbiór autorskich propozycji rozwiązania konstrukcji ścian zewnętrznych budynków w aspekcie zmian prawnych dotyczących ochrony cieplnej budynków. Dla trzynastu modeli obudowy budynku w kontekście zewnętrznej ściany – o zbliżonej wartości współczynnika przenikania ciepła – podano zdolność do akumulacji energii termicznej w warstwie nośnej przegrody.
EN
The publication presents a set of original suggestions for solutions regarding construction of external walls of buildings in the aspect of legal changes regarding thermal protection of buildings. For thirteen models of building enclosures in the context of the external wall – with similar heat transfer coefficient value – the capability to accumulate thermal energy in the load-bearing layer of the barrier has been given.
13
PL
Systemy grzewczo-chłodzące w budynkach energooszczędnych są w wielu przypadkach przewymiarowane, dlatego niezbędna jest korekta metody obliczania projektowego obciążenia cieplnego i obciążenia chłodniczego. Należy rozdzielić przekazywanie ciepła na drodze promieniowania od wymiany ciepła przez konwekcję. W metodyce obliczania projektowego obciążenia cieplnego nie są uwzględniane zyski ciepła od promieniowania słonecznego, ludzi, oświetlenia i urządzeń, które są akumulowane w przegrodach, co należy uwzględnić. Konieczne jest również przyjęcie, jako kryterium projektowe, temperatury operatywnej będącej średnią temperatury powietrza i temperatury powierzchni przegród otaczających człowieka. W artykule przedstawiono różnice w warunkach wymiany ciepła w systemie powietrznym i wodnym płaszczyznowym, biorąc pod uwagę wpływ powierzchni oddziałujących na człowieka (ściany zewnętrzne, przegrody wewnętrzne, płaszczyzny aktywowane termicznie). Zaproponowano metodę obliczania zapotrzebowania na energię do ogrzewanie i chłodzenia w wodnych płaszczyznowych systemach grzewczo-chłodzących. Przedstawiono zestaw równań modelu 14R4C pozwalający obliczyć temperaturę powierzchni, temperaturę komponentów o znanej pojemności cieplnej i temperaturę powietrza. Zaprezentowano wyniki obliczeń w wypadku przykładowego pomieszczenia biurowego.
EN
Heating and cooling systems for energy-efficient buildings are in many cases oversized, and it is necessary to revise the calculation method of design heating load and cooling load. It is necessary to separate heat transfer by radiation from heat transfer by convection. In the methodology of calculating the design heating load, heat gains from solar radiation, people, lighting and devices (which are accumulate in the building partitions) are not taken into consideration, and it should be reviewed. It is also necessary to adopt as the design criterion the operative temperature, which is average of the air temperature and the surfaces temperature. The article presents differences in heat flow for air systems and radiant systems, taking into account the influence of surfaces (external walls, internal walls, thermally activated surfaces). A method of calculating the energy use for space heating and cooling for radiant heating and cooling systems is presented. An equations of the 14R4C model which allows calculating surfaces temperature, air temperature and temperature inside components which thermal capacity is known are presented. Calculation results for an office room are presented.
PL
W artykule przedstawiono wyniki badań eksperymentalnych zrealizowanych na próbkach z betonu komórkowego o gęstości 400 kg/m3 i 700 kg/m3. W pierwszym etapie próbki poddano działaniu ciekłej wody, która wprowadzana była do ich wnętrza siłami podciągania kapilarnego. Następnie przystąpiono do pomiarów podstawowych parametrów cieplnych, prowadzonych na próbkach o różnym poziomie zawilgocenia. Wyznaczano współczynnik przewodzenia ciepła λ oraz objętościową pojemność cieplną cp. Równocześnie część próbek poddano nasycaniu wodą, aż do momentu ustabilizowania się ich masy. Następnie próbki poddano suszeniu w warunkach laboratoryjnych, rejestrując tempo tego procesu przez okres pół roku. Głównym celem przeprowadzonego eksperymentu było wyznaczenie obydwu parametrów cieplnych dla próbek o różnym stanie zawilgocenia, a następnie odwzorowanie czasowych zmian zachodzących w parametrach cieplnych testowanych betonów komórkowych w trakcie ich wysychania z zawilgocenia powodziowego. Zmienne rozkłady wilgotności oraz przewodności i pojemności cieplnej po grubości przegrody odtworzono po upływie 1, 2, 3, 4 oraz 6 miesięcy trwania procesu wysychania. Dane zebrane w przypadku obydwu badanych klas betonów 400 i 700 wskazują na wyraźnie różny przebieg procesu – tak pod względem jakościowym, jak i ilościowym. Badania dotyczące betonu klasy 400 dowodzą silnego zróżnicowania w rozkładzie badanych wielkości fizycznych (λ, cp oraz Uv) zarówno po miesięcznym, jak i 2-miesięcznym okresie wysychania oraz powrót do stanu zbliżonego do wyjściowego pod względem wilgotnościowym i cieplnym po upływie około 3-miesięcznego okresu wysychania. W przypadku betonu komórkowego klasy 700 okres 6 miesięcy okazał się być niewystarczający, aby uzyskać parametry cieplne i wilgotnościowe zbliżone do wartości, jakie miałby materiał w stanie naturalnej wilgotności.
EN
The paper describes the results of experimental studies which were conducted on the samples of aerated concrete of density class 400 kg/m3 and 700 kg/m3. Initially, the samples were exposed to a strong effect of liquid water which was introduced into their interior by capillary forces. Next, basic thermal parameters were measured and some tests were carried out on samples of various degree of moisture. The coefficient of thermal conductivity λ and the heat capacity cp were determined. At the same time, a part of the samples was saturated with water until they stabilized. Next, the samples were dried under laboratory conditions, recording the rate of this process for a period of half a year. The main goal of the experiment was to determine both thermal parameters for the samples of various degree of moisture and then to map the temporal changes in the thermal parameters of the tested aerated concretes during the drying out of post flood moisture. The variables of moisture distribution, thermal conductivity and heat capacity across the width of wall were reconstructed after 1, 2, 3, 4 and finally 6 months of drying process. In case of the both classes researched (400 and 700), all collected data indicate at clearly different courses of the process in qualitative and quantitative character. Research concerning 400 class concrete proves strong differentiation in the distribution of the tested physical parameters (λ, cp and Uv) after both, 1 and 2 month periods of drying and return after 3 months to the state similar to the initial one regarding moisture and heat distribution. In case of 700 class aerated concrete, a period of 6 month drying proves to be too short in order to obtain thermal and moisture parameters similar to the values which the material would have in the state of natural conditions.
15
Content available remote Dynamika elektrycznych elementów grzejnych powszechnego użytku
PL
W artykule dokonano charakterystyki elektrycznych elementów grzejnych stosowanych powszechnie w branży AGD lub technice grzewczej, a także w układach sterowania niektórych procesów technologicznych. Szczególną uwagę zwrócono na różnice pojemności cieplnej wybranych elementów grzejnych, która ma istotny wpływ na energochłonność procesów grzewczych w stanach przejściowych.
EN
The paper contains characteristics of commonly used electric heating elements. Such elements are used for example in household appliances or heating technology. The greatest attention is paid to the heat capacity differences of selected heating elements. This parameter has a significant impact on energy consumption in transient states.
PL
Materiały PCM charakteryzują się znacznie większą akumulacją cieplną niż powszechnie stosowane materiały budowlane. Akumulacja ciepła jest wynikiem nie tylko zwiększenia ich temperatury (ciepło właściwe), ale przede wszystkim jest związana z izotermiczną przemianą fazową (najczęściej topnieniem), charakteryzującą się dużym ciepłem przemiany, tzw. ciepłem utajonym. Materiały PCM pełniłyby w bloczkach ABK rolę akumulatorów ciepła lub chłodu, który pochłaniałby nadwyżki ciepła z różnych źródeł i uwalniał je do pomieszczenia w okresie występowania niskiej temperatury w otoczeniu. W ten sposób ograniczyłoby się wahania temperatury w pomieszczeniu, redukując je do zakresu zgodnego z wymaganiami komfortu cieplnego. W artykule przedstawiono zasadność stosowania materiałów zmiennofazowych PCM w produkcji autoklawizowanych betonów komórkowych ABK oraz wyniki badań wpływu zmiennej ilości materiałów zmiennofazowych PCM na właściwości betonu komórkowego. Badania właściwości betonu komórkowego prowadzono wg EN 771-4.
EN
The materials using PCM characterized by considerably higher the effective heat capacity than the commonly used construction materials. Heat accumulations is due not only to increase their temperature (heat capacity), but it’s connected with the isothermal phase change (most melting). It characterized by a heat of transformation, so, latent heat. PCM materials played a role in the AAC blocks heat or cold battery, which would consume surplus heat from various sources and released them into the room during periods of low temperature outside. In the way it reduces the fluctuations of the room temperature, reducing it the extent compatible with the requirements of thermal comfort. In the article the authors present research possibility of the use of phase change materials PCM to the production of autoclaved aerated concrete AAC. Research the influence of the changeable amount PCM on properties autoclaved aerated concrete will also stay in this paper. Research of properties autoclaved aerated concrete will be conducted according to EN 771-4.
17
Content available remote Wpływ izolacyjnych deskowań traconych na właściwości energetyczne budynków
PL
Kształtując układy materiałowe przegród zewnętrznych, bierze się głównie pod uwagę wymaganą wartość współczynnika przenikania ciepła. W artykule pokazano, że w bilansie zapotrzebowania na ciepło budynku równie istotnym czynnikiem jest pojemność cieplna przegród.
EN
While forming material sets of external partitions the attention is paid to required value of heat permeability coefficient. In the article it was showed that in the heat requirement balance of a building the heat capacity of partitions is an equally essential factor.
PL
W niniejszej pracy poddano analizie wpływ użytego kruszywa na właściwości termiczne kompozytów betonowych o niemodyfikowanej matrycy cementowej. Przetestowano trzy rodzaje kruszyw: kruszywo kamienne o dużej szczelności oraz dwa kruszywa lekkie: keramzytowe oraz popiołoporytowe. Przeprowadzono rtęciowe badania porozymetryczne samych kruszyw, jak również betonów na ich bazie. Wykonane mieszanki betonowe charakteryzowały się niemodyfikowaną matrycą cementową, dzięki czemu możliwe było porównanie zróżnicowanych właściwości betonów wynikających z wariantowo dobranego kruszywa gruboziarnistego. W pracy przygotowano dwa rodzaje próbek: płytkowe do badań cieplnych oraz sześcienne potrzebne do przeprowadzenia testów wytrzymałości betonu na ściskanie. Próbki przez pierwsze 28 dni przechowywano w komorze klimatycznej w wysokiej wilgotności, następnie próbki umieszczono w powietrzno-suchych warunkach laboratoryjnych. Parametry termiczne betonów testowano przez pierwszy rok dojrzewania w zadanych przedziałach czasu. Podobnie wykonywano badania wytrzymałości na ściskanie po 7, 14, 28 dniach oraz po 3, 6 i 12 miesiącach dojrzewania betonu. W publikacji wykazano wyraźną korelację między porowatością kruszywa a przewodnością cieplną i ciepłem właściwym betonów. Struktura kruszywa miała również niebagatelny wpływ na tempo wysychania betonów. Przedstawiono także zależność między porowatością kruszyw a wytrzymałością betonu na ściskanie. W pracy pokazano także zdjęcia SEM przekrojów przez badane betony.
EN
The paper presents the impact of aggregate on the thermal properties of concrete composites with non-modified cement matrix. Three types of aggregates were tested: normal aggregate of high tightness and two lightweight aggregates: leca and lytag. Mercury porosimetry tests were conducted on aggregates, as well as on the concretes made on their basis. Concrete mixes were characterized by an unmodified cement matrix which enabled to compare the diverse properties of concretes made with different aggregates. Two types of samples were prepared in this study: plates samples for the thermal tests and cubic samples necessary for the examination of the compressive strength. The samples were kept in climate chamber for the first 28 days in high humidity atmosphere, subsequently were put in laboratory air-dry conditions. Thermal parameters of the concretes were tested during the first year of curing at specified time intervals. Likewise compressive strength tests were conducted after 7, 14, 28 days and 3, 6 and 12 months of concrete curing. In the manuscript a high correlation was observed between the porosity of aggregates and the thermal conductivity and specific heat. The structure of the aggregate had a considerable impact on the pace of concretes drying. The association between the porosity and compressive strength was also presented. The paper also shows the SEM images of the cross-sections of the tested concretes.
PL
W artykule przedstawiono analizę wyników symulacji energetycznych dotyczących grupy obiektów użyteczności publicznej o zróżnicowanej funkcji połączonych w lokalny obszar bilansowania w celu redukcji szczytowej mocy elektrycznej w okresie letnim. Przeanalizowano zapotrzebowanie na moc chłodniczą obiektów tego obszaru w okresie doby w polskich warunkach klimatycznych oraz redukcję mocy szczytowej w wyniku zastosowania technik DSM (ang. Demand Side Management) w badanych obiektach. W pracy rozpatrzono zastosowanie technik DSM: aktywnej – wstępnego schładzania obiektów w godzinach wczesno-porannych, oraz technik pasywnych – zmiany pojemności cieplnej elementów budynku oraz zastosowanie materiałów zmienno-fazowych w ich obudowie zewnętrznej. Zastosowanie w/w technik przeanalizowano także pod kątem ich opłacalności finansowej. Przeprowadzone analizy pokazują wysoki potencjał stosowania technik DSM w celu ograniczenia zapotrzebowania na moc chłodniczą w okresach szczytowego obciążenia sieci elektroenergetycznej. Dodatkowo wykazano, że połączenie szeregu obiektów o zróżnicowanej funkcji w jeden obszar bilansowania może prowadzić do bardziej równomiernego zapotrzebowania na moc elektryczną w ciągu doby. Przeprowadzona analiza kosztowa wykazuje korzyści finansowe płynące z zastosowania technik DSM.
EN
The aim of this article is analysis of energy simulation for a group of public utility buildings connected into one local assess area in order to reduce the cooling power demand peak in summer time. The analysis deals with the daily cooling energy demand of the area for the climatic conditions of Poland and the reduction of peak power demand by using Demand Side Management techniques applied in these buildings. For this end the use of various DSM techniques: active one, i.e. a decrease of operative temperature in the buildings in early morning and two passive techniques, i.e. thermal capacity increase for construction elements and use of phase changing materials in external walls, were examined. Moreover, use of the abovementioned techniques was analyzed considering their financial benefits. The analysis showed a high potential of DSM techniques application to reduce the cooling power demand during electricity grid peak hours. Additionally, connecting various public utility buildings into one assess area may lead to more steady daily electricity power demand. The analysis also showed some financial benefits of application of the DSM techniques considered.
PL
Rozwiązania architektoniczne mające wpływ na zapotrzebowanie budynku na energię to usytuowanie budynku na działce budowlanej oraz jego kształt i układ pomieszczeń w zależności od ich przeznaczenia. Większa pojemność cieplna elementów budynku poprawia skuteczność wykorzystania zysków ciepła w sezonie grzewczym. W okresie letnim budynki o mniejszej pojemności cieplnej wymagają większej ochrony przed przegrzewaniem pomieszczeń.
EN
Architectural solutions that influence the energy demand of a building result from the position of the building on the construction plot, the shape of the building, and the layout of the rooms in accordance with their purpose. A larger heat capacity of the building's elements helps the efficiency of using heat gain during the heating season. In the summer, buildings with a lower heat capacity require more protection from overheating.
first rewind previous Strona / 4 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.