Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 136

Liczba wyników na stronie
first rewind previous Strona / 7 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  partial discharge
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 7 next fast forward last
EN
An ultrasonic sensor based on extrinsic Fabry–Pérot interference (EFPI) has been designed and demonstrated to detect the ultrasonic wave signal. The sensitivity and natural frequency of fiber Fabry–Pérot (F-P) sensor with different structure parameter have been simulated by COMSOL. The simulation results illustrate that the sensitivity is up to 1.737 nm/kPa and the natural frequency is 2.1 MHz, when the silica diaphragm thickness is 2 μm, the radius is 90 μm, and the cavity length is 18 μm. The most suitable parameters have been selected and the F-P sensor has been fabricated. When the ultrasonic signals with the frequencies of 40 kHz and 1.2 MHz are respectively applied to the sensor, the frequencies detected by the EFPI ultrasonic sensor are 39 kHz and 1.21 MHz based on a partial discharge detection experiment for the designed demodulation system. The experimental results show that the sensor can accurately detect ultrasonic signals. As an excellent platform for ultrasonic signal sensing, this EFPI ultrasonic sensing system has great potential applications in partial discharge detection field.
EN
The electrical cable reliability is largely linked to the state of its insulation, which can be threatened by the partial discharges (PDs) activity. This phenomenon is localized in defects created within insulation during the manufacture process and the cable installation. The cavity defect is among the most known defects within the insulating material filled with different gases and having various forms. Under electrical stress, the PDs occur and lead with time to a cable failure. The PDs simulation in cavity defect within cable insulation has became an important tool for a complementary understanding of the experimental task. The plasma model has been considered in last decade as an alternative to describe physically and chemically the PDs mechanism versus the other models such as the capacitance, conductance model. Using plasma model our work aims to simulate the PDs in cavity defect within cable insulation by showing the parameters influence such as the type of gas contained in the cavity, the voltage magnitude and frequency imposed on the insulation on their occurrence through its occurrence mechanisms. This helps to assess the PDs severity on the insulation system to carry out its diagnosis and therefore to have an effective reliability of cable.
PL
Przedstawiono stosowane metody badania wyładowań niezupełnych off-line i on-line do oceny stanu technicznego wysokonapięciowej izolacji generatorów i silników. Podano zalety i wady tych metod.
EN
The article presents the methods of testing partial discharges off-line and on-line for the assessment of the technical condition of high-volta- ge insulation of generators and motors were presented. Advantages and disadvantages of these methods are given.
PL
Ocena intensywności oraz form wyładowań niezupełnych pozwala na określenie stanu izolacji urządzeń elektroenergetycznych. W artykule przedstawiono możliwości identyfikacji podstawowych form wyładowań niezupełnych, przy wykorzystaniu wybranych algorytmów uczenia maszynowego. Przedstawiono wpływ różnych metod przetwarzania wstępnego sygnałów na skuteczność modeli sztucznej inteligencji. Zaproponowano metodę ekstrakcji cech statystycznych z sygnałów emisji akustycznej pozwalających na klasyfikację form wyładowań.
EN
The assessment of the intensity and forms of partial discharges allows for the determination of the insulation condition of electrical power devices. The article presents the possibilities of partial discharge form prediction of selected machine learning algorithms. The influence of various pre-processing methods on the effectiveness of artificial intelligence models is presented. A method of extracting statistical features from acoustic emission signals has been proposed, allowing for the prediction of discharge forms.
PL
Niniejszy artykuł dotyczy transformatorów wykonanych w klasie ciepłoodporności wyższej niż A, przeznaczonych do montażu w wieżach farm wiatrowych. Ich ograniczona kubatura przy dużej mocy powodowała problemy eksploatacyjne w postaci generacji dużej ilości gazów w płynie chłodzącym. Artykuł opisuje sposób, w jaki została usprawniona seria takich transformatorów z izolacją Nomex® i estrem syntetycznym.
EN
The paper deals with transformers of thermal class higher than A and dedicated for installation inside towers of wind farm plants. The limited space inside towers caused problems of intense gas generation in cooling medium. The paper describes how the design based on Nomex® and synthetic ester was improved.
6
Content available remote The problem of ozone generation in electroadhesion devices
EN
This paper describes the problem of ozone generation during electroadhesive pad tests. For this purpose a test stand was built to supply the pad with high voltage in order to generate partial discharges on the pad surface accompanied by ozone generation. The measurement was carried out by using an ozone sensor placed together with the electroadhesive pad in a closed chamber.
PL
W tym artykule opisano problem generowania się ozonu podczas badań z wykorzystaniem padów elektroadhezyjnych. W tym celu zbudowano stanowisko pomiarowe do zasilenia pada wysokim napięciem, tak aby wytworzyły się wyładowania niezupełne na powierzchni pada, którym towarzyszy wytwarzanie się ozonu. Pomiar przeprowadzono za pomocą czujnika ozonu umieszczonego wraz z padem elektroadhezyjnym w zamkniętym naczyniu.
EN
The article contains the results of measurements and analysis of partial discharges (PD) generated on the surface of a composite insulator. PDs were recorded with a specialized camera as the number of photon emission counts in the UV range. The study comparatively analyzed the number of photon counts emitted by PD on wet, dry, clean, and contaminated surfaces with different concentrations of salt solution and kaolin.
PL
Artykuł zawiera wyniki pomiarów i analiz WNZ generowanych na powierzchni izolatora kompozytowego. WNZ rejestrowano za pomocą specjalistycznej kamery jako liczbę zliczeń emisji fotonów w zakresie UV. W badaniach poddano analizie porównawczej liczbę zliczeń fotonów emitowanych przez WNZ na powierzchniach mokrych, suchych, czystych i zanieczyszczonych różnej wielkości stężeniami roztworu solnego i kaolinu.
PL
Artykuł zawiera charakterystykę badań wyładowań niezupełnych wprowadzanych w kolejnych etapach produkcji kabli elektroenergetycznych o izolacji z papieru nasyconego i polietylenu, na wszystkich poziomach napięć znamionowych tj. średnich, wysokich i najwyższych. Zwrócono uwagę na prace CIGRE w tej dziedzinie i działalność Konferencji Wielkich Sieci Elektrycznych, których efektem był pierwszy projekt programu badań poprodukcyjnych kabli wysokiego napięcia opisany w Przeglądzie Elektrotechnicznym nr 1 w 1931 roku. W dalszej części niniejszego artykułu opisano metody pomiaru wyładowań niezupełnych realizowane w systemach pomiarowych zapewniających przetwarzanie przebiegów impulsowych wyładowań do postaci obrazów fazowych. Przedstawiono również wyniki badań laboratoryjnych oddziaływania wyładowań niezupełnych na materiały izolacyjne, w tym identyfikacje procesów erozyjnych w źródłach wyładowań i skutki migracji ładunków elektrycznych na powierzchniach granicznych w układach izolacyjnych.
EN
The article contains the characteristics of the partial discharge tests introduced in the subsequent stages of the production of power cables with insulation made of impregnated paper and polyethylene, at all voltage levels, i.e. medium, high and ultra-high voltage. Attention was paid to the work of CIGRE in this field and the activity of the Conference of Large Electric Systems, the effect of which was the first draft program for postproduction testing of high-voltage cables, described in the article in the Przegląd Elektrotechniczny No. 1 in 1931. The methods of partial discharges measurement implemented in diagnostics systems ensuring the processing of discharge pulse waveforms to the form of phase-resolved images are described. The article also presents the results of laboratory tests of the effect of partial discharges on insulating materials, including the identification of erosion processes in discharge sources and the effects of electric charge migration on the boundary surfaces of insulating systems.
9
Content available remote Partial discharge detection in transformer winding using FRA analysis
EN
In power transformer, Partial Discharge is a cause of insulation failure, and thus, procedures for the area of PD sources are required. In this paper, an endeavor has been made to present frequency response analysis (FRA) for the discovery of PD by identifying the parameters of the winding by the particule swarm optimization (PSO), and giving its impedance according to the frequency. Comparison between the frequency responses of healthy winding and the affected one the is made to detect the failure associate to the partial discharge.
PL
W transformatorach energetycznych wyładowania niezupełne są przyczyną uszkodzeń izolacji, dlatego konieczne jest opracowanie procedur wykrywania źródeł wyładowań niezupełnych. W niniejszym artykule podjęto próbę przedstawienia analizy odpowiedzi częstotliwościowej (FRA) w celu wykrycia PD poprzez identyfikację parametrów uzwojenia za pomocą optymalizacji rojem cząstek (PSO) i określenie jego impedancji w zależności od częstotliwości. Porównanie odpowiedzi częstotliwościowych uzwojenia zdrowego i uszkodzonego pozwala na wykrycie uszkodzenia związanego z wyładowaniem częściowym.
PL
W artykule zaproponowano metodę diagnostyki linii kablowych SN z wykorzystaniem analizy fazowo – rozdzielczej po montażu osprzętu kablowego. Program badań obejmował próby dla kabla XRUHAKXS 1x240/25 z wykorzystaniem metody elektrycznej i wymuszenia napięciem probierczym sinusoidalnie zmiennym. W wyniku przeprowadzonych pomiarów wyznaczono wartości ładunku pozornego oraz ich obrazy fazowo-rozdzielcze. Przedstawione wyniki eksperymentu wykazały wpływ zamodelowanego uszkodzenia w mufie kablowej SN na poziom mierzonych wyładowań niezupełnych. W ramach zrealizowanych prac dokonano także próby oceny i wskazania miejsca uszkodzenia badanego osprzętu kablowego.
EN
The article proposes a method of diagnosing MV cable lines with the use of phase-distribution analysis after the installation of cable accessories. The test program included tests for the XRUHAKXS 1x240/25 cable using the electrical method and excitation with a sinusoidal alternating test voltage. As a result of the performed measurements, the values of apparent charge and their phase-resolution images were determined. The presented results of the experiment showed the influence of the modeled damage in the MV cable joint on the level of the measured partial discharges. As part of the work carried out, attempts were also made to assess and indicate the location of damage to the tested cable accessories.
11
Content available remote Detekcja wyładowań niezupełnych w transformatorach suchych średniego napięcia
PL
Artykuł przedstawia zagadnienia problematyki diagnostyki transformatorów suchych średniego napięcia. Opracowanie przedstawia wyniki diagnostyki transformatorów z cewkami typu cast coil opartych na pomiarach wyładowań niezupełnych z użyciem metody elektrycznej jaki UHF.
EN
The article presents the problems of diagnostics of medium voltage dry transformers. The study presents the results of diagnostics of transformers with cast coils based on partial discharges measurements using the electrical method such as UHF.
12
PL
W artykule przedstawiono wyniki eksperymentalnych badań podstawowych, w ramach których dokonano analizy zmienności w czasie sygnałów elektrycznych generowanych przez wyładowania niezupełne (WNZ) przy uwzględnieniu wpływu rodzaju materiału dielektrycznego. Celem badań jest pogłębienie wiedzy o samym zjawisku WNZ i wskazanie nowych nie dostatecznie poznanych do tej pory jego aspektów. Przedstawione wyniki potwierdziły, że każdy z przebadanych materiałów dielektrycznych emituje indywidulane sygnały elektryczne, które w różnym stopniu zmieniają się w czasie.
EN
The article presents the results of experimental basic research, which analyzed the variability in time of electrical signals generated by partial discharges (PD), taking into account the influence of the type of dielectric material. The aim of the research is to deepen the knowledge about the PD phenomenon itself and to identify new, not yet sufficiently known, aspects of it. The presented results confirmed that each of the tested dielectric materials emits individual electrical signals that vary to a different extent over time.
EN
An integration of the electrical machine and the gearbox is attracting particular attention for the design of modern electric and hybrid drive trains, since it saves overall space and subsequently increases the power density. Another benefit of a high level of integration is that it enables a combined application of oils as both cooling fluid for the electrical machine and as lubrication fluid for the transmission system. In this way, the power density of the integrated drive train can be further increased. During the oil cycling, conductive contaminations may be introduced and subsequently have an influence on the function of the insulation system of the electrical machine. In the present work, the influences of the cooling oil and its conductive contaminations, conductive particles as well as their combination with humidity, on the electrical and dielectric properties of the insulation system are studied. The results show that by application of the cooling oil, the partial discharge inception voltage (PDIV) of the winding insulation increases significantly so that an electrical breakdown is prone to happen before a partial discharge (PD) occurs. With increasing particle contamination, the PDIV of the insulation system decreases significantly, while the capacitance increases. Besides, conductive particles and humidity decrease the surface resistance and surface breakdown voltage of the insulation papers significantly. The results indicate that the conductive particle contaminations can play an important role for the electrical degradation of the insulation system.
EN
This study proposes a measurement technique to identify and determine the occurrence of partial discharge in the insulation of Dry-type transformers, as well as their criteria level. Concerning IEC 62478, the four AE (acoustic emission) sensors were used to determine the PD sources and one HFCT (High-Frequency Current Transducer) technique was to identify the PD source and the criteria level. This process accurately identified the PD source location occurring at any position in a transformer. The gap time was 3.2 ms. The level of partial discharge for this case study is Major PD that means soon monitoring every 3 months. The results of this technique could prevent insulation failure of a transformer in time.
PL
Zaprezentowano technikę wykrywania wyładowań niezupełnych w izolacji suchego transformatora. Zgodnie z IEC 62478 użyto czterech czujników emisji akustycznej AE oraz jednego czujnika prądów wysokiej częstotliwości HFCT. Umożliwia to lokalizację źródła wyładowania.
EN
This paper is focusing on 3D Finite Elements Analysis (FEA) based modelling of protrusions as defects or imperfections in the XLPE high voltage cable. This study is aiming to examine the impact protrusions have on the initiation of partial discharges. Spherical and ellipsoidal protrusions with different sizes at the conductor screen of the high voltage cable is an essential content of this paper. In addition, a spherical gas-filled void is placed inside and outside the protrusions, and a water tree produced from protrusions is under consideration. The partial discharge influence taking place at the protrusions and the stress enhancement factor is determined for all the variations mentioned to quantify the rise in the inception of partial discharges due to the protrusions.
16
PL
W artykule opisano metodę lokalizacji wyładowań niezupełnych z wykorzystaniem kamery wyładowań niezupełnych. Pozwala ona na szybkie wykrycie jednego z trzech wyładowań niezupełnych czyli wyładowań koronowych. Opisano również teorię powstawania wyładowań koronowych, oraz przedstawiono skutki działania wyładowań koronowych na osprzęt elektroinstalacyjny.
EN
The article describes the method of locating partial discharge using the partial discharge camera. It allows you to quickly detect one of three partial discharges or corona discharges. The theory of corona discharge was also described, and the effects of corona discharge on power lines were presented.
PL
W artykule opartym na doświadczeniach przedstawiono szereg metod pomiarowych z wykorzystaniem różnych źródeł napięć probierczych, opis poszczególnych metod pomiarowych oraz zasady jakimi należy się kierować podczas wyboru odpowiedniego źródła napięcia probierczego.
EN
The experiential article presents a number of measurement methods using various sources of test voltages, a description of individual measurement methods and principles to be followed when selecting the appropriate source of test voltage.
PL
Artykuł prezentuje wyniki analizy porównawczej pomiarów wyładowań niezupełnych prowadzonych trzema metodami: metodą emisji akustycznej, metodą elektryczną oraz metodą bazująca na pomiarach światła emitowanego w paśmie UV. W artykule wykazano istnienie korelacji między wynikami uzyskiwanymi różnymi metodami pomiarowymi. W dalszej perspektywie celem jest opracowanie kryteriów, na podstawie których możliwe będzie zakwalifikowanie badanego elementu elektroizolacyjnego jako sprawnego, zagrożonego uszkodzeniem lub też uszkodzonego.
EN
The article presents the results of a comparative analysis of partial discharge measurements using electric, acoustic emission and UV emission methods for the development of comparison and decision criteria, on the basis of which it will be possible to quickly qualify the tested insulating element as efficient, endangered by damage or damaged.
EN
Variable speed and low voltage electrical drives are commonly operated by frequency converters. According to recent developments, there is a trend in the area of semi-conductors, that switching frequency and voltage slew rate will increase significantly. The aim of these semiconductors is to reduce the switching losses and to increase the switching frequency, which enables to reduce the size of passive components in the powerelectric circuit. This results in less material effort and lower cost, for the power electronic component. However, electric motors operated by high slew rate inverters show problems in the winding insulation, which have to be analyzed. Such problems are well known for high voltage machines. Due to the increasing slew rate, this problematic occurs in low voltage machines nowadays as well. Here, the influence of fast switching semiconductors on the winding insulation system is studied, using accelerated ageing tests with fast switching high-voltage generators.
EN
This paper presents comparative analysis of various acoustic signals expected during partial discharge (PD) measurements in operating power transformer. Main purpose of the paper is to yield relevant and reliable method to distinguish between various acoustic emission (AE) signals emitted by PD and other sources, with particular consideration of real-life results rather than laboratory simulations. Therefore, selected examples of real-life AE signals registered in seven different power transformers, under normal operation conditions, within few years are showed and analyzed. Five scenarios are investigated, which represent five types of AE sources: PD generated by artificial sources, and next four real-life sources (including PD in working transformer, oil flow, oil pumps and core). Several different signal processing methods are applied and compared in order to identify the PD signals. As a result, an energy patterns analysis based on the wavelet decomposition is found as the most reliable tool for identification of PD signals. The presented results may significantly support the process of interpretation of the PD measurement results, and may be used by field engineers as well as other researchers involved in PD analysis using AE method. Finally, observed properties also provide a solid basis for establishing or improving complete classification method based on the artificial intelligence algorithms.
first rewind previous Strona / 7 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.