RU
Vypolneny serii cislennyh eksperimental’nyh issledovanij passivnogo solnecnogo otopitel’nogo pribora povysennogo termiceskogo soprotivlenia, kotoryj sostoit iz prozracnoj stenki i teplo-svetovogo absorbera, prostranstvo mezdu kotorymi razdeleno naklonnymi prozracnymi antikonvektivnymi peregorodkami. Polucennye rezul’taty pokazali vlianie orientacii otopitel’nogo pribora na ego KPD. Privedeny rekomendacii po effektivnoj orientacii solnecnogo otopitel’nogo pribora i sootvetstvuusie KPD v zavisimosti ot daty i vremeni sutok.
EN
Series of numerical experimental research are performed on models of passive solar heater of high thermal resistance, which consists of a transparent wall and the heat and light absorber, the space between wall and absorber is divided by inclined transparent anti-convective barriers. The results showed the influence of the orientation of the heater on its efficiency. The recommendations for an effective orientation of the solar heater and the corresponding efficiency depending on the date and time of day are presented.
EN
This paper presents the possibility of reducing the demand for nonrenewable primary energy for buildings using a new conceptual adsorption system of cooling and heating supplied by solar energy. Moreover, the aim of this study is to shorten the payback time of investment in the standard adsorption cooling system through its integration with the heating system. Research has been carried out for an energy-efficient medium-sized single-family building with a floor area of 140 m 2 and a heat load of 4.2 kW and cold load of 4.41 kW. It has been shown that the use of an adsorption system of cooling and heating supplied by solar energy decreased the demand for nonrenewable primary energy by about 66% compared to the standard building that meets the current requirements.
EN
The paper describes the measurements of temperature growth in different types of the epoxy adhesive bonding external strengthening. A total of six types of models were tested: CFRP sheet and strip, two SRP tapes adhered to the concrete sample, CFRP strip and SRP tape on a timber sample. Changes in temperature were investigated during the summer in the southern Poland. The maximum measured temperatures for all models exceeded regarded as safe temperature limit of 45°C. The highest recorded adhesive temperature refers to a sample of CFRP strengthened timber and exceeded 70°C. For the structure such a high temperature may result in almost complete loss of adhesion and thus the efficiency of strengthening. Test results may be a warning against the use of FRP external strengthening exposed to direct sunlight without any protection.
PL
W artykule opisano pomiary wzrostu temperatury w różnych rodzajach klejów epoksydowych połączeń wzmocnień zewnętrznych. Przebadano łącznie sześć rodzajów modeli: matę i taśmę CFRP, dwie taśmy SRP przyklejone do próbki betonu, taśmę CFRP i taśmę SRP na próbce drewna. Zmiany temperatury były badane w okresie letnim w południowej Polsce. Maksymalne zmierzone temperatury dla wszystkich modeli przekroczyły uznawaną za bezpieczną granicę temperatury 45°C. Najwyższa zanotowana temperatura kleju dotyczy próbki drewnianej wzmocnionej CFRP i przekroczyła 70°C. Tak wysoka temperatura w konstrukcji może spowodować prawie całkowitą utratę przyczepności, a tym samym efektywności wzmocnienia. Wyniki badań mogą być ostrzeżeniem przed stosowaniem zewnętrznego wzmocnienia FRP poddanego bezpośredniemu działaniu nasłonecznienia bez żadnej ochrony.
EN
Solar energy systems and heat pumps are two promising means of reducing the consumption of fossil energy resources and the cost of delivered energy for residential heating. The integration of these two installations presents a novel combined heating system, so-called bivalent system, operating more economically. The major objective of this paper was to analyze the possibility of construction and benefits of a bivalent system composed of a heat pump and solar collectors for heating and cooling residential buildings.
EN
The paper presents an analysis of efficiency of the modified Trombe wall with forced convection that could be operating in four different modes. The analyzed system comprises a double glass glazing, and a massive wall with an opening and central channel in it. In order to increase the efficiency, a fan is provided at the bottom vent of the wall. It is more advanced as compared with simple Trombe solar wall with a relatively low thermal resistance, which is taken as a reference in experimental analysis. The mathematical model, composed for the massive solar wall efficiency, is usually very complicated and assessment of the thermal behaviour requires the use of thermal simulation techniques. This paper presents steady-state and one-dimensional mathematical model for simplified analysis of thermal efficiency of modified Trombe solar wall that is working in heating mode. The results from presenting model were analyzed to predict the effects of variations in the constructive and operating parameters on the efficiency. The obtained results were used for simple and fast running design tools that designers can use in the early phases of the design process for calculations of efficiency of the active solar heating systems.
PL
W artykule przedstawiono analizę efektywności zmodyfikowanej ściany Trombe'a z wymuszonym obiegiem, która może działać w czterech różnych trybach. Analizowany system składa się z podwójnych szyb i masywnej ściany z otworem oraz centralnym kanałem. W celu zwiększenia efektywności systemu, wentylator został usytuowany w dolnym otworze ściany. Przedstawiony system jest bardziej zaawansowany w porównaniu z konwencjonalną ścianą Trombe'a o stosunkowo niskiej odporności termicznej, która przyjęta jest w pracy, jako punkt odniesienie w analizie eksperymentalnej. W artykule przedstawiono jednowymiarowy model matematyczny w stanie stacjonarnym i zastosowano go w celu przeprowadzenia uproszczonej analizy sprawności cieplnej zmodyfikowanej ściany Trombe'a. Wyniki uzyskane z zaprezentowanego modelu analizowano pod kątem określenia wpływu zmian konstrukcyjnych i operacyjnych parametrów na efektywność systemu. Uzyskane rezultaty zostały wykorzystane jako proste i efektywne narzędzia projektowe, które mogą służyć we wczesnych fazach procesu projektowania do obliczeń wydajności aktywnych solarnych systemów grzewczych.
6
Content available remote Take off for Solar District Heating in Europe
EN
In total, there are about >25 million m2 of glazed solar collectors in Europe, corresponding to about 18 GWn, (thermal power), where the majority of the collectors are installed in small systems with up to a few kW,h. European large-scale solar heating plants having more than 500 m" (~350 kWlh) of solar collectors have only about 170 MWlh altogether, so only a minor part of the European collector market comprises large-scale applications, i.e. about 1% of the installations. However, the relevant heat loads vary from a few kWlh up to several GWlh and about 9% of the heating loads in Europe are covered by block and district heating systems. There is thus a need to develop large-scale applications in order to utilize the full potential of solar heat to cover existing heat loads. The further development of district heating systems is likely to play a major role on the future European energy market, e.g. in Germany and Poland. To acknowledge the importance of large-scale solar heating (and cooling) systems, the European Solar Thermal Technology Platform - ESTTP - has assigned one working group for Solar District Heating (and Cooling). The vision for large-scale systems is further developed in co-operation with representatives for Euroheat & Power with the intention to broaden the number of potential actors to develop, demonstrate and promote solar heat in district heating (and cooling) applications. A number of technologies are already applied in demonstration projects mainly in the northern parts of Europe, e.g. Sweden, Denmark, Germany and Austria. At present, there are about 40 plants with > 1 400 m2 (1 MWth) solar collectors and the largest plant so far in Europe is designed with 18 000 m2 (13 MWlh) solar collectors. The paper describes technology status, presents strengths, weaknesses, opportunities and threats, as well as a vision that claims that it could be feasible with close to 20 PJ solar heat in district heating systems in 2020 with a more progressive policy.
PL
Przedstawiono zależności pomiędzy parametrami klimatu zewnętrznego a natężeniem przepływu ciepła przez przegrody budowlane wyposażone w pasywne systemy ogrzewania słonecznego. Analizie poddano następujące parametry klimatu zewnętrznego: temperatura powietrza zewnętrznego, natężenie promieniowania słonecznego, prędkość wiatru oraz ciśnienie i wilgotność powietrza. Wyniki przedstawiono na podstawie badań doświadczalnych w postaci graficznej oraz jako współczynniki korelacji.
EN
The paper describes correlations between parameters of the external climate and the intensity of the heat flow, appointed experimentally for walls with passive solar systems. The analysis is made for the following parameters of the external climate: temperature of the external air, the intensity of the solar radiation, the speed of the wind and the pressure and the atmospheric humidity. The results were showed in the graphic froms and as the coefficients of correlation.
EN
Solar heating plant or a district heating network. The paper will describe a development of roof integrated collectors from site built colectors to prefabricated roof module collectors based on two major applications: new residential buildings built by EKSTA Bostads AB and existing multifamily buildings renovated by Gärdstensbostäder AB, both municipal housing companies are in the Gőteborg area. Since early 1980`s EKSTA has built about 10 new residential developments with about 6000 m2 of solar collectors on a number of new buildings. The majority of buildings, typically better insulated than required by the Swedish building code, are connected to local heating plants combining wood pellet or briquette boilers and solar heating using roof-integrated solar collectors. Gärdstensbostäder has carried out a renovation project with the aim to demonstrate a comprehensive intyegrated concept, comprising energy concervation and utilisation of solar energy, as well as improved architectural and social conditions, making the buildings in a typical existing residential building area from the 1970`s more attractive. The project comprises 500 apartments in3-5 floor concrete element in six blocks. The renovation was carried out in two phases: one finished late 2000 and one finished in early 2004. One innovative feature is 1 410 m2 prefabricated roof modules with integrated solar collectors for pre-heating DHW.
10
Content available remote Izolacje transparentne w systemie pasywnego ogrzewania słonecznego
PL
Zmiany na światowym rynku paliw (i in. źródeł energii), związane głównie z wyczerpywaniem się zasobów naturalnych, spowodowały wzrost międzynarodowego zainteresowania racjonalizacją gospodarki energetycznej we wszystkich dziedzinach życia. Przewiduje się [5], że przy obecnym poziomie produkcji ropy naftowej wystarczy na około 50 lat, gazu ziemnego na 70 lat, a węgla na 190 lat.
PL
W artykule przeanalizowano warunki dopływu energii promieniowania słonecznego oraz przedstawiono Regionalizacja helioenergetyczna Polski. Na podstawie przeprowadzonej długoterminowej symulacji numerycznej przedstawione wyniki charakteryzują możliwości wykorzystania promieniowania słonecznego do celów grzewczych dla Polski Centralnej.
12
Content available remote Kolektory słoneczne
13
Content available remote Analysis of temperature distribution in double pane glazing system with air gap
EN
Aspects discussed within this paper apply to determination of temperature distribution in a double pane glazing system with air gap. These considerations are the base for the determination of thermal influences of external-environment on the storage barrier in passive solar heating systems. Application of such systems is a noteworthy method for realization of energy-saving facilities, characterized by low consumption of heat energy.
PL
Rozważania dotyczą określania rozkładu temperatur w układzie dwuszybowego przeszklenia ze szczeliną powietrzną. Rozważania te są podstawą do wyznaczania oddziaływania cieplnego otoczenia na przegrodę akumulacyjną w pasywnych systemach ogrzewania słonecznego. Zastosowanie tych systemów jest godnym uwagi sposobem realizacji obiektów energooszczędnych charakteryzujących się niskim zużyciem energii cieplnej.
PL
Przedstawiono wyniki badań. Potwierdzono możliwość zaoszczędzenia energii, gdy w ścianie południowej zastosuje się pasywny system ogrzewania słonecznego.
EN
The energy savings possibilities thanks to the location of solar heating system on the south building wall have been proved.
15
Content available remote Heat energy balance equations in double-pane glazing system with air gap
EN
The analyzed double-pane glazing system with air gap is a component of the construction wall adapted for solar radiation capture and its utilization for heating of rooms in buildings. A double-glazing set, made in form of a compact frame and transmitting solar radiation to massive thermal-storage wall located behind the glazing is a passive method to utilize the energy of solar radiation in building construction. The paper presents equations for heat energy balance in double-pane glazing system with air gap as a basis for the determination of temperature distribution in analyzed system.
PL
Rozpatrywany w pracy dwuszybowy układ oszklenia ze szczeliną powietrzną jest elementem składowym przegrody budowlanej przystosowanej do pozyskiwania energii promieniowania słonecznego i wykorzystywania jej do ogrzewania pomieszczeń w budynkach. Zestaw podwójnego oszklenia wykonany w postaci zwartej ramy i przekazujący promieniowanie słoneczne do masowej ściany akumulacyjnej umieszczonej za przeszkleniem jest pasywnym sposobem wykorzystania energii promieniowania słonecznego w budownictwie. W pracy przedstawiono równania bilansowe energii cieplnej w dwuszybowym układzie oszklenia ze szczeliną powietrzną będące podstawą do określania rozkładów temperatury w pasywnych systemach ogrzewania słonecznego.
PL
Przedstawiono równania bilansowe oraz tok uproszczonych obliczeń rocznego zapotrzebowania na ciepło do ogrzewania budynków mieszkalnych i im podobnych w porównawczym sezonie ogrzewczym.Poinformowano o możliwych ułatwieniach przy sporządzeniu charakterystyki,mającej na celu ocenę jakości ochrony cieplnej pomieszczeń oraz efektywności energetycznej systemu pasywnego ogrzewania słonecznego
EN
Energy balance equation and algorithme of calculation of energy requirements for heating of residential building in standard heating season are conidered.Certain possibilities of simplification in energycharacteristics calculation required to evaluate the quality of thermal protection and the energy efficiency of passive solar heating are described.