EN
One of the problems with iron removal from groundwater is organic matter. The article presents the experiments involved groundwater samples with a high concentration of total iron - amounting to 7.20 mgFe/dm 3 and an increased amount of organic substances (TOC from 5.50 to 7.50 mgC/dm3). The water samples examined differed in terms of the value of the ratio of the TOC concentration and the concentration of total iron (D). It was concluded that with increase in the coexistence ratio of organic substances and total iron in water (D = [TOC]/[Fetot]), efficiency of Fe(II) to Fe(III) oxidization with dissolved oxygen decreased, while the oxidation time was increasing. This rule was not demonstrated for potassium manganate (VII) when used as an oxidizing agent. The application of potassium manganate (VII) for oxidation of Fe(II) ions produced the better results in terms of total iron concentration reduction in the sedimentation process than the oxidation with dissolved oxygen.
PL
Przedmiotem badań była woda podziemna charakteryzująca się wysokim stężeniem żelaza ogólnego do 7,20 mgFe/dm3 oraz podwyższoną zawartością substancji organicznych (OWO od 5,50 do 7,50 mgC/dm3 ). Badane próbki wody różniły się wartością ilorazu stężenia OWO do stężenia żelaza ogólnego (D), udziałem stężenia Fe(II) w stężeniu Feog (C), a jej mętność i intensywność barwy wskazywały na obecność koloidalnych oraz rozpuszczonych połączeń żelaza ze związkami organicznymi. Celem badań było określenie wpływu stężenia substancji organicznych w wodzie podziemnej na skuteczność utleniania Fe(II) do Fe(III) tlenem rozpuszczonym w wodzie lub manganianem (VII) potasu, a także na skuteczność usuwania związków żelaza w procesie sedymentacji. Wykazano, że wraz ze wzrostem wartości współczynnika współwystępowania substancji organicznych i żelaza ogólnego w wodzie surowej (D) zmniejszała się skuteczność utleniania Fe(II) do Fe(III) tlenem rozpuszczonym. W próbkach wody, w których do utleniania Fe(II) stosowano manganian (VII) potasu nie stwierdzono wpływu wartości współczynnika D na skuteczność utlenienia Fe(II) do Fe(III). Zastosowanie manganianu (VII) potasu jako utleniacza zapewniło większą skuteczność usuwania związków żelaza z wody podziemnej w procesie sedymentacji niż napowietrzanie.
EN
The following thesis’s objective is to analyze the quality of underground water for consumption, illustrated with an example of water for Czestochowa city. Although underground water is much better than surface water in terms of quality, it’s necessary to monitor the water’s quality constantly as it may decline due to many reasons during the exploitation of intakes. The importance of this is emphasized by the fact that there have been changes in water’s intake over the past 30 years in Poland. The changes involved the increase of share of underground water in the total amount of used water resources by 70.4% to 2012. Drinking water is mainly deliver to consumers by water companies, whose duties involve drawing water from natural sources and preparing it in such a way so that it is harmless to consumers. The selection of water treatment technological processes is mainly determined by raw water quality. Sanitary safety is a major priority in water treatment process, whose main aim is assuring water biostability. Biological stability of water is confirmed by the content of BDOC (biodegradable dissolved organic carbon) and AOC (assimilable organic carbon). The permissible content of AOC and BDOC in non-chlorinated water is 3÷10 and 160 μg/L, respectively. The research results show that BDOC and AOC content in raw water was 20÷95 μg/L and 5÷19 μg/L, respectively. Therefore all examined waters met requirements for biostability in terms of BDOC content. In terms of AOC content, however, only 3 out of 6 waters met these requirements. Moreover the research results show that 47% of examined quality parameters classified underground water for Czestochowa city as first class water, 29% as second class, 18% as third class and 6% as fifth class. When treating underground water as drinking water, its quality parameters met the standards of water intended for human consumption, with the exception of nitrates concentration in the water from intake A’s well, which was 62.1 mg/L and exceeded the acceptable concentration by 24%.
PL
Celem niniejszej pracy jest analiza jakości wód podziemnych ujmowanych na cele konsumpcyjne na przykładzie wody dla miasta Częstochowa. Chociaż pod względem jakości woda podziemna jest znacznie lepsza od wody powierzchniowej, konieczne jest monitorowanie jej jakości cały czas, ponieważ może ulegać ona obniżeniu podczas eksploatacji ujęć z wielu powodów. Jest to o tyle istotne, iż nastąpiły zmiany w spożyciu wody w ciągu ostatnich 30 lat w Polsce. Dotyczyły one wzrostu udziału wód podziemnych w ogólnej ilości eksploatowanych zasobów wodnych do 70,4% do 2012 roku. Woda pitna jest dostarczana głównie do konsumentów przez przedsiębiorstwa wodociągowe, których obowiązki obejmują czerpanie wody ze źródeł naturalnych i przygotowanie jej w taki sposób, aby była ona nieszkodliwa dla odbiorców. Wybór metody i technologii uzdatniania wody zależą głównie od jakości wody surowej. Priorytetem w procesie uzdatniania wody jest zapewnienie bezpieczeństwa sanitarnego wody. Innymi słowy, głównym celem jest zapewnienie biostabilności wody. O stabilności biologicznej wody świadczy przede wszystkim zawartość BRWO (biodegradowalny rozpuszczony węgiel organiczny) i PWO (przyswajalny węgiel organiczny). Dopuszczalna zawartość BRWO i PWO w wodzie niechlorowanej wynosi odpowiednio 160 i 3÷10 μg/l. Wyniki badań pokazują, że zawartość BRWO i PWO w wodzie surowej wynosiła 5÷19 i 20÷95 μg/l. Dlatego wszystkie badane wody spełniały wymagania dotyczące biostabilności pod względem zawartości BRWO. Jednakże pod względem zawartości PWO tylko 3 z 6 badanych wód spełniały te wymagania. Ponadto wyniki badań pokazują, że 47% analizowanych parametrów jakościowych wód podziemnych dla miasta Częstochowa sklasyfikowano w pierwszej klasy wód, 29% w drugiej klasie, 18% w trzeciej klasie, a 6% w piątej klasie. Rozważając wody podziemne jako wody pitne, ich parametry jakościowe spełniały standardy wody przeznaczonej do spożycia przez ludzi z wyjątkiem stężenia azotanów w wodzie ze studni A, które wynosiło 62,1 mg/l, i przekroczyło dopuszczalne stężenie o 24%.
PL
Skuteczność usuwania substancji organicznych w konwencjonalnym układzie oczyszczania wód podziemnych oraz w procesie koagulacji koagulantami glinowymi: siarczanem glinu, glinianem sodu, chlorkiem poliglinu (PAX XL-60), a także koagulantem żelazowym PIX-112. Wykazano, że o skuteczności procesu koagulacji w usuwaniu substancji organicznych współdecydowały rodzaj koagulantu i jego dawka, a także temperatura, pH i wartość współczynnika współwystępowania związków organicznych i żelaza ogólnego w wodzie surowej.
EN
Removal efficiency of organic matter in conventional water treatment system of underground and in the process of coagulation aluminium coagulants: aluminum sulfate, sodium aluminate, polyaluminium chloride (PAX XL-60), and ferric coagulant PIX-112. It was shown that the effectiveness of coagulation in the removal of organic matter was determined while the type and dose of coagulant, as well as temperature, pH and the value of coexistence of organic compounds and total iron in raw water.
EN
The effectiveness of groundwater treatment with a high amount of organic substances and general iron depended on the kind of oxidizing agent, the kind and dose of coagulant, and the time of sedimentation. The effectiveness of the sedimentation process increased with the length of time of the process, and its results depended most on the method of oxidizing Fe(II). From among the oxidizing agents used before the coagulation process the best results in terms of a decrease in colour, turbidity, the concentration of manganese and organic substances were obtained in the case of oxidization with potassium permanganate, and as far as the effectiveness of removing general iron was concerned oxidizing with dissolved oxygen.
PL
Skuteczność usuwania zanieczyszczeń z wody podziemnej o podwyższonej zawartości substancji organicznych i żelaza ogólnego zależała od rodzaju stosowanego utleniacza, czasu sedymentacji oraz rodzaju koagulantu i jego dawki. Skuteczność procesu sedymentacji zwiększała się wraz z czasem trwania procesu, a o jej efektach w największym stopniu decydował sposób utleniania Fe(II). Lepsze efekty oczyszczania wody podczas procesu sedymentacji uzyskano stosując manganian (VII) potasu jako utleniacz niż tlen rozpuszczony, ponieważ wytrącajacy się z wody MnO2, działając jako obciążnik i adsorbent, poprawił właściwości sedymentacyjne aglomeratów Fe(OH)3. Ilość żelaza ogólnego usuniętego z wody w wyniku utleniania Fe(II) tlenem rozpuszczonym a następnie jego sedymentacji, zmniejszała się wraz ze wzrostem współczynnika współwystępowania substancji organicznych i żelaza ogólnego w wodzie surowej. Spośród stosowanych sposobów utleniania żelaza (II) przed procesem koagulacji lepsze efekty z uwagi na efekty zmniejszenia barwy, mętności, stężenia manganu i substancji organicznych, zapewniło utlenianie manganianem (VII) potasu, natomiast z uwagi na skuteczność usuwania żelaza ogólnego utlenianie tlenem rozpuszczonym.
EN
Results after raw water and aerated water treatment. Comparison of the diminishing levels for colour, oxygen consumption, turbidity and general iron concentration after application of aluminium sulphate and polyaluminium chloride. Influence of the coagulant's type and dose on average consumption of general basicity of water treatment.
EN
Characteristics of filtrating materials used in the research. Changes in colour, turbidity, oxygen consumption, ferrum and manganium compounds in the filtrate after applying clinoptylolite and MZ-10 mass. Oxidizing capacities of the used materials. Comparison of used cathalytic masses.
PL
W artykule przedstawiono procedurę postępowania w ocenie możliwości zastosowania technologii bariery remediacyjnej. Przedstawiono najważniejsze czynniki decydujące o tej ocenie oraz zaproponowano wykonywanie w początkowym etapie procedury oceny wstępnej, która ogranicza zakres analizy do kilku najistotniejszych elementów. Ponadto przedstawiono kryteria oceny możliwości zastosowania technologii bariery remediacyjnej, które mogą być pomocne w podjęciu decyzji o akceptacji bądź rezygnacji z jej stosowania w pierwszych etapach procedury.
EN
The procedure stage in the assessment of possibilities of using PRB technology is presented in this paper. The most important factors of that assessment have been selected. It was suggested to use preliminary assessment during the initial stage of the procedure, as it limits the range of the analysis to several most important elements. The criteria for the assessment of possibilities to use PRB technology were specified in the paper, as they may be helpful to decide whether this technology should be accepted or not in the first stages of the procedure.
EN
Laboratory research on the use of processed natural Crystal-Right 100 zeolite. Bed cut-through curves for iron, manganese, ammonium nitrogene and their hardness. Changes in basicity and pH reaction during the bed's working. Defining optimal speed for filtration. Regeneration of a used-up bed with brine. Use of bed for water treatment for industrial purposes.
PL
Dla zwiększenia bezpieczeństwa użytkowania gazu ziemnego w przemyśle i gospodarce komunalnej wprowadza się do niego odorant w celu nadania mu charakterystycznej woni. Umożliwia to szybkie i łatwe wykrycie ewentualnych nieszczelności występujących w sieci rozdzielczej i urządzeniach grzewczych. Odorant najczęściej wprowadzany jest do gazu ziemnego poprzez instalację dozującą zainstalowaną w stacji redukcyjno-pomiarowej. Jednym z elementów tej instalacji jest zbiornik z odorantem, który w przypadku rozszczelnienia może być źródłem skażenia środowiska gruntowo-wodnego. W artykule przedstawiono wyniki badań geologicznych i hydrogeologicznych czwartorzędowego poziomu wodonośnego skażonego dwucyklopentadienem (DCP) w rejonie stacji redukcyjno-pomiarowej gazu. Dla ustalenia zasięgu rozprzestrzeniania się DCP w wodach podziemnych odwiercono dziewięć otworów monitoringowych, z których pobrano próbki gruntu i wody do badań laboratoryjnych. W każdym z otworów wykonano również pomiar głębokości zwierciadła wody oraz przeprowadzono badania współczynnika filtracji. Otrzymane wyniki posłużyły do wykonania mapy potencjometrycznej wód wgłębnych oraz mapy koncentracji w nich DCP. Wykonano również modelowanie warunków hydrogeologicznych czwartorzędowego poziomu wodonośnego przy wykorzystaniu programu Processing Modflow. Opracowany model posłużył do wykonania prognozy rozprzestrzeniania się DCP w środowisku gruntowo-wodnym oraz warunków jego remediacji.
EN
To increase the security level, natural gas is being odored with a specific scent both in industrial and in municipal practice. This enables quick and easy detection of leaks in the distribution network and heating systems. The odorant is most frequently introduced to the gas through a dosing installment from a reduction-gauge station. One of the elements of the station is a tank with odorant, which in the case of untightness can be a source of ground-water environmental pollution. The results of geological and hydrogeological analyses of the Quaternary aquifer polluted with a dicyclopentadiene (DCP) near the reduction-gauge station are presented in the paper. To establish the range of DCP propagation in groundwaters, nine monitoring wells were drilled, out of which water and soil samples were collected for laboratory analyses. In each of the wells, there were also made measurements of depth of water level and filtration coefficient. Based on the obtained results, potentiometric maps of groundwaters and maps of DCP concentration were made. Hydrogeological conditions of athe Quaternary aquifer was also analysed with the use of the Processing Modflow program. This model facilitated prediction of DCP propagation in water-soil environment and the conditions of its remediation.