Altered breathing rate is an important sign of disease status. Currently used machine-based monitoring of the breathing rate includes contact with the body, which may result in pain and discomfort. In this paper, a non-contact breathing monitoring technique is proposed by integrating RGB and thermal imaging systems with RGB-thermal image registration. This method provides a linear mapping for automated selection of the region of interest (ROI) followed by tracking to extract the breathing rate. To evaluate the efficacy of the proposed approach and its robustness against motion, talking, varying breathing rate or rhythm, and high ambient temperature, this study was conducted in three phases. Validation of the proposed approach demonstrated a strong agreement with the reference method of breathing rate monitoring using a respiration belt. During normal breathing, the mean absolute error (MAE) reached 0.11 bpm (breaths per minute). While in more challenging conditions, defined by three phases, the MAE reached 1.46, 2.08, and 1.69 bpm, respectively. In short, the proposed method performance is a promising alternative to a contact-based method due to its strong agreement and might be useful in diverse applications such as sport studies, rehabilitation centres, quarantine centres, and in hospital or airport screening during the COVID 19 pandemic.
PL
W artykule przedstawiono prototypowy układ termoanemometryczny wraz z dedykowaną sondą do pomiaru strumienia objętości przepływu, znajdującymi zastosowanie w systemach do monitorowania oddechu. W ramach realizowanych prac badawczych wykonano wielokanałowy termoanemometryczny układ pomiarowy w wersji do indywidualnej zabudowy oraz dwuwłókową sondę koncepcyjną. Działanie systemu przetestowano na stanowisku do wzorcowania. W oparciu o wykonane eksperymenty i zebrane wyniki wykonano optymalizację konstrukcji czujnika pod kątem lokalizacji włókna termometrycznego.
EN
The paper presents a prototype thermoanemometric system with probe for measuring the flow volume, which can be used in respiratory monitoring systems. The framework of the task included designing, implementation and testing of the multi-channel thermoanemometric measurement system dedicated for individual development and a 2-wires concept sensor. Measurement system was tested on volumetric flow calibration stand. Based on performed experiments and collected results, the sensor construction was optimized for the location of the thermometric and anemometric wires.
EN
Cleep apnea episedes may cause potential baby's life threateiiing events and can be one of t h e first syndromes of other 11-laesses. Apnea is supposed to be one of t h e risk factors of Sudden Infant Death Syndrome (SIDS). Infanfs breath monitoring and immediate apnea detection, not oniy in hospitals, but also under home conditions, mereases the baby's safety and aiiow recognition of cliseases at an earlier stage. This paper presents a model of n ew device for detection of apnea, consisting of a three-axis MEMS (Micro Electro-Mechanical Systems) accelerometer with digital output, microprocessor and sosie alarm Instruments. The deyice allows the monitoring of both, the breathing movements of the child's abdomen, as weil as the vibrations of th e abdominal wali associated with t h e heart action and enables early detection of central and obstractiye apnea. Another usefu! application of die described model i s the possibility of monitoring t h e baby- 'a position during sleep. The paper presents the hardware, apnea detection procedure and the performance of the physical model of the apnea monitor.
PL
Bezdech senny stanowi potencjalne zagrożenie życia niemowląt i może być pierwszym syndromem innych schorzeń. Jest on uznawany za jeden z czynników ryzyka Zespołu Nagłego Zgonu Niemowląt (SIDS - Sudden Infant Death Syndrome). Monitorowanie oddechu niemowląt i szybkie rozpoznawanie stanów bezdechu nie tylko w szpitalu, ale także w warunkach domowych, zwiększa bezpieczeństwo dziecka i ułatwia wykrywanie innych chorób w ich wczesnym stadium. Przedstawiony artykuł opisuje model nowego urządzeniu przeznaczonego do wykrywania bezdechu, zbudowanego z akcelerometru MEMS (Micro Elektro-Mechanical Systems) o trzech osiach czułośći z wyjściem cyfrowym, mikroprocesora i elementów alarmujących. Urządzenie monitoruje ruchy oddechowe dziecka i wibracje ściany brzucha towarzyszące pracy serca, przez co umożliwia szybkie wykrywanie zarówno bezdechu centralnego, jak i obturacyjnego. Inną użyteczną funkcją prezentowanego modelu jest możliwość kontroli pozycji dziecka podczas snu. W artykule opisano układ, procedurę detekcji bezdechu oraz pierwsze wyniki uzyskane z wykorzystaniem przedstawionego modelu monitora.