In this study, a novel method is proposed to optimize the reinforced parameters influencing the bearing capacity of a shallow square foundation resting on sandy soil reinforced with geosynthetic. The parameters to be optimized are reinforcement length (L), the number of reinforcement layers (N), the depth of the topmost layer of geosynthetic (U), and the vertical distance between two reinforcement layers (X). To achieve this objective, 25 laboratory small-scale model tests were conducted on reinforced sand. This laboratory-scale model has used two geosynthetics as reinforcement materials and one sandy soil. Firstly, the effect of reinforcement parameters on the bearing load was investigated using the analysis of variance (ANOVA). Both response surface methodology (RSM) and artificial neural networks (ANN) tools were applied and compared to model bearing capacity. Finally, the multiobjective genetic algorithm (MOGA) coupled with RSM and ANN models was used to solve multi objective optimization problems. The design of bearing capacity is considered a multi-objective optimization problem. In this regard, the two conflicting objectives are the need to maximize bearing capacity and minimize the cost. According to the obtained results, an informed decision regarding the design of the bearing capacity of reinforced sand is reached.
PL
W artykule przedstawiono wyniki badań elektromagnetycznych kilku modeli zbrojenia ortogonalnego z zastosowaniem Profometru PM-650. Oceniono powtarzalność pomiarów w przypadku różnego usytuowania tzw. ośrodka pomiaru względem pręta poprzecznego i oszacowano wartości błędów pomiarowych. Stwierdzono, że pozycja skanera istotnie wpływa na pomiar średnicy, natomiast w mniejszym stopniu na pomiar otuliny. W artykule poruszono również problem wpływu na wyniki czynników zaburzających pole elektromagnetyczne. W efekcie przeprowadzonych badań sformułowano zalecenia praktyczne.
EN
The article presents the results of electromagnetic research of several models of orthogonal reinforcement. Profometer PM-650 was used. The repeatability of measurements for different locations of the so-called measurement centre relative to the transverse member was evaluated and the values of measurement errors were estimated. It was found that the position of the scanner significantly affects the measurement of the diameter, while the measurement of the coating affects to a lesser extent. The article also discusses the problem of influencing the results of electromagnetic field disruptors. Practical recommendations were formulated.
PL
W artykule omówiono projekt, wykonanie i właściwości akustyczne ściennego ceglanego dyfuzora dźwięku wykonanego z tradycyjnej cegły klinkierowej, zastosowanego w Sali Koncertowej im. Krzysztofa Pendereckiego z widownią na 550 miejsc w Radomiu. Omówiono wstępne analizy przy użyciu modeli komputerowych, późniejsze badania na modelach w skali oraz badania na pełnowymiarowych elementach w komorze pogłosowej.
EN
This paper discusses the design, realization and acoustical performance of a brick wall diffuser constructed from clincker brick for 550 seats concert hall, located in Radom, Poland opened in 2010. Early designs with computer models as well as later scale model tests and full scale reverberation mesurements are described.
PL
W artykule opisano badania ścian z autoklawizowanego betonu komórkowego (ABK) w skali naturalnej, w których zastosowano nowy typ zbrojenia z siatki stalowej. Omówiono wpływ zbrojenia na strefę połączenia ścian prostopadłych. Przeanalizowano nośność i rysoodporność połączenia. Wyniki porównano z wynikami badań wcześniejszych [1, 2]. Artykuł jest drugą częścią publikacji [3] oraz kontynuacją badań opisanych w [1, 2].
EN
The article describes the tests of walls made of autoclaved aerated concrete (AAC) on a full scale, in which the new type of steel mesh reinforcement was used. The influence of reinforcement on the connection zone of perpendicular walls was described. The load capacity and crack resistance of the connection zone were analysed. The results were compared with those of earlier studies [1, 2]. The article is the second part of the tests published in [3] and a continuation of earlier research [1, 2].
5
Content available remote Wpływ otworu i sztywności nadproża na nośność ścian z ABK
PL
W artykule opisano wyniki badań ścian wzniesionych z bloczków z ABK (autoklawizowany beton komórkowy) w skali naturalnej, ściskanych w płaszczyźnie ściany. Przeprowadzono trzy serie badawcze po dwie ściany. Przebadano dwie ściany bez otworu i dwie serie po dwie ściany z otworem i nadprożami z ABK oraz nadprożami żelbetowymi. Celem badań było określenie wpływu otworu oraz sztywności nadproża na nośność ścian. Wykazano, że ściany z otworami cechują się nośnością i rysoodpornością nawet mniejszą o 2/3 w porównaniu z nośnością i rysoodpornością ściany pełnej. Nie stwierdzono istotnego wpływu nośności i sztywności nadproża na uzyskane wyniki sił rysujących i niszczących.
EN
The article describes the results of tests of walls built of AAC blocks (autoclaved aerated concrete) on a full scale, compressed in the plane of the wall. Three series of tests, two walls each, were subjected to the study. Two walls without an opening and two series of two walls with an opening and ABK lintels and reinforced concrete lintels were tested. The aim of the research was to determine the impact of the opening and the impact of the lintel stiffness on the load capacity of the walls. It has been shown that walls with openings are characterized by load-bearing capacity and crack resistance which is up to 2/3 lower compared to the loadbearing capacity and crack resistance of a solid wall. No significant influence of the bearing capacity and stiffness of the lintel on the obtained results of tearing and destructive forces was found.
PL
Zbrojenie w konstrukcjach murowych stosuje się w celu ograniczenia zarysowań i zwiększenia nośności ścian. W artykule opisano badania ścian z autoklawizowanego betonu komórkowego (ABK) w skali naturalnej, w których zastosowano nowy typ zbrojenia z siatki stalowej. Określono wpływ zbrojenia na strefę wokół okna. Prezentowane badania są kontynuacją wcześniejszych podobnych analiz, opublikowanych w miesięczniku „Materiały Budowlane” [1, 2]. Uzyskane wyniki badań porównano z wynikami opublikowanymi w [1, 2, 3].
EN
Reinforcement in masonry structures is used to reduce cracks' width and increase the load-bearing capacity of walls. The article describes the study of autoclaved aerated concrete (AAC) walls in a full scale. A new type of steel mesh reinforcement was used in the tests. The influence of the reinforcement on the zone around the window was determined. The presented research is a continuation of previous similar analyzes published in Building Materials [1, 2]. The obtained tests results were compared with the results published in [1, 2, 3].
EN
The subject of the article concerns road embankments made of reinforced soil. The results of the analysis of the effectiveness of the reinforcement of these structures as a function of selected variable factors concerning the soil medium and the parameters of reinforcement inserts are given. The efficiency analysis was carried out on the basis of measurements of the horizontal unit pressure made on a physical model of a soil massif with a vertical wall of reinforced soil. The large-scale model was constructed on a laboratory scale. The article ends with a summary containing conclusions of a cognitive and practical nature.
PL
Przedmiotem prezentowanych badań jest wykorzystanie efektu elastoakustycznego AE do wyznaczania naprężeń w murze wykonanym z autoklawizowanego betonu komórkowego poddanego osiowemu ściskaniu. Wykorzystano zależności wiążące wartość naprężeń ściskających z prędkością podłużnej fali ultradźwiękowej z uwzględnieniem wilgotności ABK. Identyfikację stanu naprężeń przeprowadzono w dziewięciu niewielkich modelach muru poddanego osiowemu ściskaniu. Wykazano, że średnie naprężenia ściskające w murze, wyznaczone proponowaną metodą, można z zadowalającym poziomem ufności rozpoznać do poziomu ok. 50% naprężeń niszczących. Przy naprężeniach rzędu 75% naprężeń niszczących wyniki okazały się istotnie zaniżone.
EN
The subject of the presented research was the use of the AE electroacoustic effect to determine the stresses in a wall made of AAC subjected to axial compression. The relationships linking the value of the compressive stresses with the velocity of the longitudinal ultrasonic wave, taking into account the AAC humidity, were used. The stress state was identified in 9 small models of masonry subjected to axial compression. It was shown that the average compressive stresses in the wall determined by the proposed method can be recognized with a satisfactory level of confidence up to the level of about 50% of the failure stresses. At higher stresses of 75% of the breaking stress, the results turned out to be significantly underestimated.
9
Content available remote Stropy panelowe – rynek polski i światowy
PL
Stropy panelowe pojawiły się na rynkach światowych na początku XXI w., a w Polsce ponad dziesięć lat później. Obecnie rozwiązania te są często pierwszym wyborem konstrukcji stropów w przypadku 8% polskich projektantów. Wraz ze zwiększonym zainteresowaniem komercyjnym, stropy panelowe coraz częściej stają się przedmiotem badań naukowych. Szczególne miejsce znalazły w Azji, gdzie badania są prowadzone w szerokim zakresie, mającym zwiększyć możliwości stosowania prefabrykatów. Autorskie badania długotrwałe wykazały cechy dwukierunkowej pracy paneli stropowych, wynikające z wykonania warstwy nadbetonu oraz specjalnie ukształtowanych zamków ścinanych. W efekcie ugięcie zostało zmniejszone nawet o 70% w odniesieniu do stosowanych w praktyce uproszczonych metod obliczeniowych. Stropy panelowe stanowią odpowiedź na zmiany gospodarcze zachodzące w ostatnich latach na rynku krajowym.
EN
Panel slabs are a solution that appeared on world markets in the first half of the 21st century. The first elements manufactured in Poland were introduced over ten years later. Currently, these elements are indicated as the first choice by 8% of Polish designers. With the increased commercial interest, panel slabs are increasingly becoming elements of scientific research. They found a special place in Asia, where research is carried out in many areas to expand precast elements’ applications. The authors’ long-term research has shown the panels’ two-way work’s decisive features, resulting from the concrete overtopping and specially shaped shear key. As a result, the deflections are reduced even by 70% compared to the simplified calculation methods used in practice. Panel slabs are the market’s response to economic changes in the domestic market in recent years.
PL
W artykule opisano badanie wpływu zbrojenia spoin wspornych na wytrzymałość na ściskanie i ścinanie murów z autoklawizowanego betonu komórkowego (ABK) zgodnie z wytycznymi odpowiednio normy europejskiej EN 1052-1:2000 i amerykańskiej ASTM ES519-81. Zastosowano zbrojenie w postaci pasów siatki rozwijanej z rolki, składającej się z linek stalowych z osnową z włókna szklanego. Wpływ tego typu zbrojenia porównano również z wynikami badań ścian murowanych z ABK bez zbrojenia oraz wzmocnionych odpowiednio zbrojeniem kratownicowym i siatką syntetyczną.
EN
This paper presents a research of influence of horizontal reinforcement on compressive and shear strength of Autoclaved Aerated Concrete (AAC) masonry. Specimens were tested according to guidelines of EN 1052-1:2000 and ASTM ES519-81 code in case of compression and shear test respectively. Reinforcement in the form of strips of mesh rolled out from a roll, consists of steel cords with an interwoven fiberglass roving was used. The influence of this type of reinforcement was also compared with the results of tests of AAC masonry walls without reinforcement, reinforced with truss type reinforcement and reinforced with synthetic mesh respectively.
EN
The subject of the wind tunnel tests is a steel chimney 85 m high of cylindrical - type structure with a grid-type curtain structure situated at its upper part. The model of the upper part of the chimney made in the scale of 1:19 was equipped with 3 levels of wind pressure measurement points. Each level contained 24 points connected with pressure scanners. On the base of the pressure measurements, both mean and instantaneous aerodynamic drag and side force coefficients were determined. Next wind gust factors for these two wind action components were determined. Moreover, for each pressure signal Fast Fourier Transform was done. Mean wind action components were also determined using stain gauge aerodynamic balance. Obtained results make possible to conclude that the solution applied in the upper part of the designed chimney is correct from building aerodynamics point of view. Some minor vortex excitations were observed during model tests of the upper part of the chimney. The basic dynamic excitation of this part of the chimney is atmospheric turbulence.
PL
Przedmiotem badań w tunelu aerodynamicznym był stalowy komin wysokości 85 m, o konstrukcji cylindrycznej z umieszczoną w górnej części konstrukcją siatki osłonowej. Model górnej części komina wykonany w skali 1:19 został wyposażony w 3 poziomy punktów pomiarowych ciśnienia wiatru. Każdy poziom zawierał 24 punkty połączone ze skanerami ciśnienia. Na podstawie pomiarów ciśnienia wyznaczono średni i chwilowy współczynnik oporu aerodynamicznego oraz współczynniki siły bocznej. Następnie określono współczynniki porywów wiatru dla tych dwóch składowych działania wiatru. Ponadto dla każdego sygnału ciśnienia wykonano szybką transformację Fouriera. Średnie składowe siły działania wiatru zostały również określone przy użyciu wagi aerodynamicznej. Uzyskane wyniki pozwalają stwierdzić, że rozwiązanie zastosowane w górnej części projektowanego komina jest poprawne z punktu widzenia aerodynamiki budowli. Podczas badań modelowych górnej części komina praktycznie nie zaobserwowano wzbudzeń wirowych. Podstawowym wzbudzeniem dynamicznym tej części komina są turbulencje atmosferyczne.
EN
The objective of this paper is to describe the effect of cavities on the bearing capacity of two interfering footings based on granular soil using an exclusively experimental approach with a test model designed in the laboratory. The experimental protocol was carried out based on the variation of several parameters such as the spacing (x) (axis to axis) between the footings, and the distance (H) between the footings and cavities and between the cavities axes (L). The results highlight the effect of cavities and the interference of two strip footings on the bearing capacity factor (q) and efficiency factor (EF). Moreover, the results revealed that, in the case wherein the distance between the footings and the cavity is greater than 3, the cavity impact is eliminated.
PL
W artykule przedstawiono opis zachowania się połączeń zbrojonych ścian z autoklawizowanego betonu komórkowego (ABK). Jako zbrojenie zastosowano klasyczne blaszki perforowane, a także autorskie łączniki. Analogicznie jak w przypadku połączeń niezbrojonych (przedstawionych we wcześniejszej publikacji) określono i zdefiniowano fazy pracy połączenia. Zaproponowano empiryczne podejście umożliwiające określenie sił i przemieszczeń połączenia z wykorzystaniem wyników badań pochodzących z mniej skomplikowanych badań standardowych.
EN
The article presents a description of the behavior of joints of reinforced walls of autoclaved aerated concrete. Classic a punched flat profile were used as reinforcements, as well as proprietary connectors. Similarly as in the case of unreinforced connections (presented in an earlier publication) individual phases of the connection's operation were defined. An empirical approach was proposed to determine the forces and displacements of the wall connection using test results from less complex standard tests.
PL
W artykule przedstawiono wyniki badań doświadczalnych wpływu wzmocnienia powierzchniowego systemem FRCM na wytrzymałość na ściskanie zarysowanych murów z autoklawizowanego betonu komórkowego (ABK). Badania przeprowadzono na modelach murów z rysą pionową oraz bez zarysowania. Program badań obejmował modele bez wzmocnienia oraz wzmocnione z dwóch i czterech stron, w tym z dodatkowym zakotwieniem wzmocnienia powierzchniowego elementami stalowymi. W modelach wzmocnionych nie odnotowano wzrostu wartości maksymalnego naprężenia niszczącego. Stwierdzono jedynie wzrost poziomu odkształcalności murów wzmocnionych w porównaniu z murami bez wzmocnienia.
EN
This paper describes results from studies on effects of superficial strengthening with FRCM system on compressive strength of autoclaved aerated concrete (AAC) masonry. Tests were carried out on models with one vertical crack and without crack. The research program included walls without any strengthening, strengthened at two or four sides. In addition, models with additional anchorage of superficial strengthening by steel plates were tested. Strengthened masonry did not demonstrate an increase of compressive strength and deformability. Increased deformability was observed for circumferentially strengthened masonry.
16
Content available remote Analiza porównawcza nieskrępowanych i skrępowanych ściskanych ścian z ABK
PL
Mury skrępowane są stosowane dość powszechnie, a mimo to nie prowadzi się zbyt wielu badań dotyczących ich zachowania pod wpływem obciążenia statycznego. W Laboratorium Wydziału Budownictwa Politechniki Śląskiej zostały przeprowadzone kompleksowe badania ścian wykonanych z elementów murowych z betonu komórkowego. Ich głównym celem było określenie wpływu skrępowania, w postaci żelbetowych rdzeni połączonych ryglem, na nośność, odkształcalność oraz rysoodporność ścian murowanych, poddanych ściskaniu w ich płaszczyźnie. Badania pozwoliły również na obserwację mechanizmu zarysowania i zniszczenia elementów próbnych.
EN
Although this type of construction is used quite widely, there is not much research on its behavior under static load. In the Laboratory of the Faculty of Civil Engineering at Silesian University of Technology, masonry walls made of autoclaved aerated concrete were tested under static load. The main purpose of the research was determine the influence of confining masonry walls by reinforced concrete columns and beam on the load-bearing capacity, deformability and scratch resistance of masonry walls subjected to compression in their plane. Indirectly, the research also allowed for observations of the mechanism of scratches and destruction of sample elements.
PL
Opisano autorski pomysł dynamicznego działania na warstwę przyziemną atmosfery jako efektywną metodę wentylacji i redukcji smogu obszarów zurbanizowanych. Przeprowadzone badania dotyczyły efektywności wież wentylacyjnych i komina wentylacyjnego oraz współpracy koncentrycznego wentylatorów systemu z kominem wentylacyjnym. Wyniki potwierdziły, że sprawność systemu jest wystarczająca.
EN
This paper describes the original ideas about dynamic action on atmospheric boundary layer as an effective method of urban ventilation and smog reduction. The performed tests focuses on efficiency of ventilation towers and vertical exhaust (ventilation chimney) and cooperation between a concentric system of ventilation towers and a ventilation chimney. The results confirmed a sufficient level of efficiency of cleaning an area where the system is located.
EN
This paper presents the results obtained from an experimental programme and numerical investigations conducted on model tests of strip footing resting on reinforced and unreinforced sand slopes. The study focused on the determination of ultimate bearing capacity of strip footing subjected to eccentric load located either towards or opposite to the slope facing. Strip footing models were tested under different eccentricities of vertical load. The obtained results from tests conducted on unreinforced sand slope showed that the increase in eccentricity of applied load towards the slope facing decreases the ultimate bearing capacity of footing. Predictions of the ultimate bearing capacity obtained by the effective width rule are in good agreement with those proposed from the consideration of total width of footing subjected to eccentric load. The ultimate bearing capacity of an eccentrically loaded footing on a reinforced sand slope can be derived from that of axially loaded footing resting on horizontal sand ground when adopting the effective width rule and the coefficient of reduction due to the slope. When increasing the distance between the footing border to the slope crest, for unreinforced and reinforced ground slope by geogrids, the ultimate bearing capacity of footing is no more affected by the slope ground.
EN
The longitudinal motion characteristics of a slender trimaran equipped with and without a T-foil near the bow are investigated by experimental and numerical methods. Computational fluid dynamics ( CFD) method is used in this study. The seakeeping characteristics such as heave, pitch and vertical acceleration in head regular waves are analyzed in various wave conditions. Numerical simulations have been validated by comparisons with experimental tests. The influence of large wave amplitudes and size of T-foil on the longitudinal motion of trimaran are analyzed. The present systematic study demonstrates that the numerical results are in a reasonable agreement with the experimental data. The research implied that the longitudinal motion response values are greatly reduced with the use of T-foil.
20
Content available remote Zarysowanie i zniszczenie ścian skrępowanych ścinanych poziomo
PL
W artykule przedstawiono wyniki naprężeń rysujących i niszczących sześciu ścian skrępowanych ścinanych poziomo wykonanych z elementów murowych z ABK. Wymiary zewnętrzne ścian wynosiły: grubość t = 0,18 m; długość l = 4,43 m; wysokość h = 2,49 m. Ściany badano przy wstępnych naprężeniach ściskających σc = 0,1; 0,75 i 1,0 N/mm2. Analizowano wartości naprężeń rysujących i niszczących w odniesieniu do wyników badań ścian niezbrojonych, zbrojonych stalowymi kratowniczkami i siatkami z tworzywa sztucznego.
EN
The paper presents the results of cracking and ultimate shear stresses of 6 confined walls made of AAC masonry units. The external dimensions of the walls were: thickness t = 0.18 m; length l = 4.43 m; height h = 2.49 m. The walls were tested at initial compressive stresses equal to σc = 0.1; 0.75 and 1.0 N/mm2. The values of cracking and ultimate shear stresses were analyzed in relation to the results of tests of unreinforced walls, walls reinforced with steel trusses and plastic grid.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.