EN
Magnetotherapy is physical therapeutic method in human medicine based on the application of pulsed magnetic fields. The magnetic flux density and intensity of electric field were measured for 32 programs of the Biomag device and all its applicators and their combinations (solenoid, triangle, light, solenoid + light, triangle + light). Each program was switched on for 5 minutes with intensity set to 100%. The highest value of magnetic flux density 420.98 µT was achieved by the program with the highest frequency 160 Hz. A statistically significant difference in the magnetic flux density was detected during the application of a radiofrequency signal on the control unit (decrease in magnetic flux density on average by 20.42 µT) compared to without the radiofrequency signal. Using Biomag device under laboratory conditions, an average value of 2.13 µT and the highest maximum 56.78 µT were found. The values did not reach the ICNIRP limits but exceeded the EUROPAEM/BioInitiative recommendations. Simulations and measurements with and without a human head phantom confirmed that low frequency magnetic fields are not significantly attenuated in artificial brain tissue. The measured values in the head phantom ranged from 239 µT to 323 µT. The aim of this study was to verify if the tested device can be used not only for supplemental human magnetotherapy but also for the experimental purposes.
PL
Magnetoterapia to fizykoterapeutyczna metoda w medycynie człowieka oparta na zastosowaniu impulsowych pól magnetycznych. Zmierzono gęstość strumienia magnetycznego i natężenie pola elektrycznego dla 32 programów urządzenia Biomag i wszystkich jego aplikatorów oraz ich kombinacji (elektromagnes, trójkąt, światło, elektromagnes + światło, trójkąt + światło). Każdy program włączano na 5 minut z intensywnością ustawioną na 100%. Największą wartość gęstości strumienia magnetycznego 420,98 µT uzyskał program o najwyższej częstotliwości 160 Hz. Wykryto statystycznie istotną różnicę w gęstości strumienia magnetycznego podczas przykładania sygnału o częstotliwości radiowej do jednostki sterującej (spadek gęstości strumienia magnetycznego średnio o 20,42 µT) w porównaniu z brakiem sygnału o częstotliwości radiowej. Używając urządzenia Biomag w warunkach laboratoryjnych uzyskano średnią wartość 2,13 µT i najwyższe maksimum 56,78 µT. Wartości nie osiągnęły limitów ICNIRP, ale przekroczyły zalecenia EUROPAEM/BioInitiative. Symulacje i pomiary z fantomem ludzkiej głowy i bez niego potwierdziły, że pola magnetyczne o niskiej częstotliwości nie są znacząco osłabiane w sztucznej tkance mózgowej. Zmierzone wartości w fantomie głowy mieściły się w zakresie od 239 µT do 323 µT. Celem pracy było sprawdzenie, czy badane urządzenie może być wykorzystywane nie tylko do uzupełniającej magnetoterapii człowieka, ale również do celów eksperymentalnych.
PL
Problemem współczesnej medycyny pozostaje leczenie przewlekłych ran, zwłaszcza kończyn dolnych, będących najczęściej skutkiem choroby cukrzycowej, chorób naczyń żylnych i tętniczych oraz problemów z profilaktyką żywienia i niezdrowym trybem życia, co prowadzi w Polsce do ponad 10 000 amputacji rocznie. Amputacja kończyn znacząco obniża jakość życia pacjenta oraz zwiększa koszty leczenia. Obecnie poszukuje się środków, które skutecznie leczą niegojące się rany podudzi. Przedmiotem opracowania jest omówienie nowoczesnych metod fizykalnych w terapii medycznej oraz ocena ich skuteczności na podstawie analizy dostępnej literatury. Pod uwagę wzięto opracowania historyczne dotyczące podstawowych praw fizykobiomedycznych oraz opracowania z ostatnich 10 lat, w których omawiane są poszczególne aplikacje terapeutyczne. W artykule tym znajdują się podstawowe informacje na temat parametrów pracy urządzeń biomedycznych, w których stosuje się: światłoterapię, magnetoterapię, tlenoterapię oraz ozonoterapię. Omawiana literatura wskazuje, że w obliczu systematycznie zwiększającego się problemu choroby cukrzycowej, a co za tym idzie wzrostu liczby wystąpienia stopy cukrzycowej, terapie fizykalne realizowane przez urządzenia nowego typu mogą być skuteczną formą wspierającą konwencjonalną terapię i mogą odegrać kluczowe znaczenie przy ratowaniu kończyn przed amputacją.
EN
Problem of modern medicine remains the treatment of chronic wounds, especially the lower limbs, which are most often the result of diabetic disease, venous and arterial disease as well as nutritional deficiencies and unhealthy lifestyle, which leads to over 10,000 amputations per year in Poland. Limb amputation significantly reduces the patients’ quality of life and increases treatment costs. At present, effective treatments of non-healing lower limb wounds are still being sought. The subject of the study is to discuss modern physical methods in medical therapy and assess their effectiveness on the basis of analysis of available literature. Historical studies on basic physiobiomedical laws and studies from the last 10 years in which individual therapeutic applications are discussed were taken into account. This article contains basic information on the parameters of biomedical devices that use: light therapy, magnetotherapy, oxygen therapy and ozone therapy. The literature discussed indicates that in the face of the systematically increasing problem of diabetic disease, and thus the increase in the number of diabetic foot occurrences, physical therapies implemented by new type devices may be an effective form supporting conventional therapy and may play a key role in saving limbs from amputation.
3
Content available remote The propagation of the electromagnetic field emitted by medical equipment
EN
The electromagnetic fields are an environmental factor affecting living organisms. In medicine, an electromagnetic fields are used in a diagnostics and a rehabilitation. The paper presents the results of measurement tests of the emission of an electromagnetic field emitted by devices in physiotherapy laboratories. The obtained values of magnetic induction were compared with the Polish standards. The results confirmed the field emission both inside and outside the applicators, the emission values at any of the measuring points did not exceed the applicable standards.
PL
Pola elektromagnetyczne są czynnikiem środowiskowym oddziałującym na organizmy żywe. W medycynie pola elektromagnetyczne stosowane są w diagnostyce i rehabilitacji. W pracy przedstawiono wyniki badań pomiarowych emisji pola elektromagnetycznego emitowanego przez urządzenia w pracowniach fizjoterapii. Porównano otrzymane wartości indukcji magnetycznej z normami obowiązującymi w Polsce. Wyniki potwierdziły emisję pola zarówno wewnątrz, jak i na zewnątrz aplikatorów, wartości emisji nie przekraczały w żadnym z punktów pomiarowych obowiązujących norm.
PL
Przedstawiony w artykule system przeznaczony jest do terapii i rehabilitacji fizykalnej w placówkach medycznych oraz w warunkach domowych. System składa się ze sterownika, aplikatorów i systemu e-zarządzania. Wymagania dyrektywy medycznej i związanych z nią zharmonizowanych norm medycznych narzucają wymagania kompatybilności elektromagnetycznej w zakresie odporności i emisji jakim podlega sprzęt jako wyrób medyczny. W artykule przedstawiono wymagania dotyczące badań, jak i przedstawiono wyniki badań omawianego systemu.
EN
The system presented in the article is intended for physical therapy and rehabilitation in medical facilities and at home. The system consists of a controller, applicators and an e-management system. The requirements of the medical directive and related harmonized medical standards impose the requirements of electromagnetic compatibility in terms of immunity and emissions of equipment as a medical device. The article presents test requirements as well as the results of the research of the discussed system.
PL
W artykule przedstawiono problematykę konstrukcyjną wytworzenia sygnałów elektrycznych do zasilania aplikatorów wielkości fizykalnych, kodowanie aplikatorów w celu ich diagnostyki oraz formy zabezpieczenia systemu zasilania w przypadku awarii aplikatorów. Przedstawiono również działanie układu ładowania baterii wraz z licznikiem ładunku potrzebnym do wyznaczenia stanu naładowania.
EN
The article presents the construction problems of generating electrical signals to supply applicators of physical quantities. Coding of applicators is described for their diagnostics and forms of power supply protection in case of applicator failure. The operation of the battery charging system together with the charge meter needed to determine the state of charge was also presented.
EN
Electromagnetic field is used in magnetotherapy. The therapy effectiveness depends on the value of magnetic induction and its distribution in applicators. An important problem is an appropriate choice of an applicator to be used in the therapy. The results presented in the paper shows that the applicators size determines the magnetic induction distribution inside the solenoid, generated for the same excitation conditions.
PL
Pole elektromagnetyczne jest używane w magnetoterapii. Skuteczność terapii zależy od wartości indukcji magnetycznej i jej rozkładu wewnątrz aplikatora. Istotnym problemem jest odpowiedni wybór aplikatora zastosowanego w terapii. Wyniki przedstawione w artykule pokazują, że rozmiar aplikatora ma wpływ na rozkład indukcji magnetycznej wewnątrz solenoidu przy jednakowych warunków wzbudzenia.
7
Content available remote System do terapii polem magnetycznym i światłem
PL
Przedstawiony w artykule system przeznaczony jest do terapii i rehabilitacji fizykalnej z zastosowaniem pól magnetycznych i światła do stosowania w placówkach medycznych oraz w warunkach domowych. System składa się ze sterownika wytwarzającego sygnały terapeutyczne, aplikatorów oraz systemu e-zarządzania. Pola magnetyczne wytwarzane w aplikatorach poprzez oddziaływanie prądów o różnych kształtach i polaryzacji znalazły swoje zastosowanie w rehabilitacji i są uznaną formą terapii.
EN
The system presented in this paper is designed for physical therapy and rehabilitation, using magnetic fields and lights for use in medical facilities and at home. The system consists of a control unit for generating therapeutic signals, applicators and an e-management system. The magnetic fields created in applicators, through the effects of currents of various shapes and polarization, have found their application in rehabilitation and are a recognized form of therapy.
EN
Over the past years, an increase in the amount of the electromagnetic sources could be observed. Model presented in this article is limited to the impact of low frequency fields generated by the e.g. electrical power lines or magnetic coils in a bone fractures therapy. Particularly, the effect of the magnetic component of the electromagnetic field on stents will be evaluated. The conductivity of human tissues will be investigated. Yielded results will be used to simplify complicated, three-dimensional problem of the current distribution in stent branches, to one-dimensional one. The merits of the paper is proposing, implementing and using for analysis a numerical model of the stent in magnetic field. The impact of frequency and positioning of stent in the magnetic field will be investigated and current distributions found.
PL
W artykule przedstawiono projektowany wielofunkcyjny system przeznaczony do terapii i rehabilitacji fizykalnej do stosowania w placówkach medycznych oraz w warunkach domowych. System składa się ze sterownika z panelem dotykowym, aplikatorów i systemu e-zarządzania. Zaimplementowane technologie ICT pozwalają na udostępnienie użytkownikom usługi e-zarządzania poprzez efektywny monitoring zabiegu oraz wynajmu sprzętu jako formy użytkowania.
EN
The article presents a designed multifunctional system dedicated for physical therapy and rehabilitation for use in medical facilities and at home. The system consists of a controller with a touch panel, applicators and an e-management system. Implemented ICT technologies allow users to provide e-management services through effective monitoring of therapy treatment and equipment rental as a form of use.
10
Content available remote Oddziaływanie aplikatorów pola magnetycznego na stenty
PL
Położenie stentu może mieć znaczący wpływ na osiągane wartości prądów indukowanych w poszczególnych gałęziach. W artykule przedstawiono również rezultaty, w których założono możliwość wystąpienia przypadku najgorszego, z punktu widzenia ewentualnego zagrożenia. W artykule przedstawiono wyniki dla jednej, przykładowej budowy stentu. Dalsze badania, powinny brać także pod uwagę szereg innych sposobów budowy stentu, znacznie bardziej zagęszczoną siatkę tworzoną przez jego gałęzie.
EN
The position of the stent may have a significant impact on its currents induced in the branches. The results are presented for the case that poses the highest danger. The results were obtained for one exemplary construction of the stent. Further research should also take into account a number of other ways of building a stent, and a much more dense mesh created by its branches.
11
Content available remote Zastosowanie pól elektromagnetycznych w leczeniu wybranych chorób układu ruchu
PL
Organizmy żywe ewoluowały w polu geomagnetycznym, dlatego większość jest czuła na pola elektromagnetyczne. Efekt oddziaływania pola elektromagnetycznego zależy zarówno od właściwości komórek wystawionych na ekspozycję, jak i parametrów użytego pola. Prace eksperymentalne i kliniczne wykazują wiele korzystnych efektów działania pól elektromagnetycznych. Artykuł ma charakter teoretyczny, przeglądowy, oparty jest na przeglądzie literatury oraz doświadczeniach własnych autora. Celem artykułu jest przedstawienie korzystnego wpływu pola elektromagnetycznego na trzy wybrane schorzenia układu ruchu. Zaprezentowano wybrane metody leczenia polem elektromagnetycznym oraz korzystny wpływ wykorzystania tych metod na układ kostny.
EN
Living organisms evolved in the geomagnetic field, thus the majority of them are sensitive to electromagnetic fields. The influence of the electromagnetic field on living organisms depends on the properties of the cells exposed to it and the parameters of the field. Experimental and clinical studies show many beneficial effects of electromagnetic fields. This article is mainly theoretical, reviewing, based on a review of literature and the author’s own experience. The main goal behind this dissertation is to present the beneficial influence of the electromagnetic field on the three selected motion system’s disorders. Methods of electromagnetic field’s treatment and the beneficial effects on the skeletal system were described in the following article.
12
Content available Magneto-therapy of human joint cartilage
EN
Purpose: The topic of the present paper concerns the human joint cartilage therapy performed by the magnetic induction field. There is proved the thesis that the applied magnetic field for concrete cartilage illness should depend on the proper relative and concrete values of applied magnetic induction, intensity as well the time of treatment duration. Additionally, very important are frequencies and amplitudes of magnetic field as well as magnetic permeability of the synovial fluid. Material and methods: The research methods used in this paper include: magnetic induction field produced by a new Polish and German magneto electronic devices for the therapy of human joint cartilage diseases, stationary and movable magnetic applicators, magnetic bandage, ferrofluid injections, author’s experience gained in Germany research institutes and practical results after measurements and information from patients. Results: The results of this paper concern concrete parameters of time dependent electro-magnetic field administration during the joint cartilage therapy duration and additionally concern the corollaries which are implied from reading values gained on the magnetic induction devices. Conclusions: The main conclusions obtained in this paper are as follows: Time dependent magnetic induction field increases the dynamic viscosity of movable synovial fluid and decreases symptoms of cartilage illness for concrete intensity of magnetic field and concrete field line architecture. The ferrofluid therapy and phospholipids bilayer simultaneously with the administrated external electromagnetic field, increases the dynamic viscosity of movable synovial fluid.
13
Content available remote Analiza gęstości prądów wirowych w modelu z implantem
PL
W pracy przedstawiono numeryczną analizę wolnozmiennego pola elektromagnetycznego (PEM) wykorzystywanego w magnetoterapii. W szczególności, uwzględniono wpływ pasywnego tytanowego implantu kolana na rozkład prądów wirowych w modelu kolana. Pokazano, że obecność implantu implikuje wzrost gęstości prądów wirowych w tkankach do wartości poniżej 20 mA/m2 tym samym wykazując, że obecność implantu nie ma wpływu na efekt terapeutyczny.
EN
The analysis of electromagnetic field (EMF) of low frequency (ELF) applied in magnetotherapy is presented. Particularly the influence of passive metallic knee implant on the distribution of eddy currents is examined. It is shown than the presence of metallic implant causes the increase of eddy currents in tissues up to the value which does not exceed 20 mA/m2. Thus, it can be concluded that the presence of metallic implant does not influence the therapeutic effect.
PL
W prawie pracy określono obowiązek rozpoznania i oceny zagrożeń elektromagnetycznych w otoczeniu urządzeń i instalacji emitujących pole elektromagnetyczne (pole-EM). W rozporządzeniu Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29 czerwca 2016 r. w sprawie bezpieczeństwa i higieny pracy przy pracach związanych z narażeniem na pole-EM wśród typowych źródeł pola-EM wymieniono „urządzenia do magnetoterapii” (DzU 2016, poz. 950, zał. 1., poz. 10., zm. poz. 2284). Urządzania do magnetoterapii są wykorzystywane do łagodzenia różnych dolegliwości, z wykorzystaniem oddziaływania quasi-statycznego pola-EM. Podczas zabiegu w pobliżu aktywnych aplikatorów występuje pole-EM stref ochronnych. W związku z tym, warunki narażenia pracujących podczas użytkowania aplikatorów wymagają okresowej kontroli, wykonanej „zgodnie z metodami określonymi w Polskich Normach, a w przypadku braku takich norm, metodami rekomendowanymi i zwalidowanymi” zgodnie z wymaganiami zawartymi w rozporządzeniu Ministra Zdrowia z dnia 2 lutego 2011 r. w sprawie badań i pomiarów czynników szkodliwych dla zdrowia w środowisku pracy (DzU 2011, poz. 166), celem rozpoznania zagrożeń elektromagnetycznych i podjęcia odpowiednich środków ochronnych (DzU 2016, poz. 950, zm. poz. 2284). Metody pomiarów pola-EM w zakresie koniecznym do realizacji wspomnianych wymagań nie są obecnie znormalizowane, w związku z tym, celem relacjonowanej pracy było opracowanie metody rekomendowanej do pomiaru parametrów pola-EM in situ w przestrzeni pracy, podczas użytkowania urządzeń do magnetoterapii lub magnetostymulacji. Na podstawie wyników przeprowadzonych badań wykazano, że podczas zabiegu fizyko-terapeutycznego źródłem pola-EM jest jedynie aplikator do magnetoterapii lub magnetostymulacji. W przypadku wykorzystywania pola-EM o częstotliwości podstawowej do 100 Hz o sinusoidalnym lub niesinusoidalnym przebiegu ciągłym – przemiennym lub prostowanym (tj. ze składową stałą), zasięg pola-EM stref ochronnych jest determinowany przez rozkład przestrzenny quasi-statycznego pola magnetycznego (pola-M). Ponieważ tego typu urządzenia przeważają w polskich placówkach fizykoterapeutycznych, do oceny zagrożeń elektromagnetycznych w przestrzeni pracy rekomendowano użycie uproszczonej metody pomiarów. Polega ona na pomiarze wartości skutecznej (RMS) na-tężenia pola-M w sinusoidalnym trybie pracy urządzenia. W ocenie wyników w takim przypadku uwzględnia się limity narażenia określone w prawie pracy w stosunku do wartości równoważnych natężenia pola-M przez użycie odpowiedniego współczynnika korekcyjnego, odzwierciedlającego konieczność zaostrzonej oceny narażenia przy niesinusoidalnym trybie pracy urządzenia (tj. użycie limitów określonych dla pola-EM o częstotliwości 100 Hz). W przypadku urządzeń emitujących pole-EM o częstotliwościach z zakresu kiloherców (kHz) lub pola-EM o impulsowej charakterystyce zarekomendowano stosowanie bardziej złożonych pomiarów, obejmujących indywidualne rozpoznanie charakterystyk mierzonego pola-EM i określenie współczynników korekcyjnych do interpretacji wyników pomiarów wartości skutecznej na podstawie charakterystyk metrologicznych stosowanych przyrządów pomiarowych. W metodzie określono również zasady: przygotowania pomiarów i aparatury pomiarowej, wyboru punktów pomiarowych, wyznaczania zasięgu stref ochronnych oraz dokumentowania wyników pomiarów. Omówiono również najistotniejsze źródła niepewności wyników pomiaru pola-EM w przestrzeni pracy przy omawianych urządzeniach.
EN
Labour law defines the obligation to identify and evaluate electromagnetic hazards in the vicinity of equipment and installations emitting an electromagnetic field (EM-field). Following the regulation of ministry of labour which set the provisions regarding the safety and health in EM-field, the "devices for magnetotherapy" have been mentioned among the typical sources of an EM-field (OJ 2016 items 950 and 2284, Annex 1, item 10). Magnetotherapy devices are used to alleviate various diseases, using the influence of aquasistatic EM-field. The protective zones of the EM-field are present near the active applicators during the treatment, so the conditions of exposure of personnel present nearby during the use of the applicators require a periodic inspection made "according to the methods specified in the Polish Standards, and in the absence of such standards, by recommended and validated methods according to the provisions of regulation of ministry of health (Regulation...,Journal of Laws2011, item 166), in order to identify electromagnetic hazards and to take appropriate protective measures (OJ 2016 item 950and 2284).The methods of measuring the EM-field to the extent necessary to meet the serequirements are currently not standardised; therefore, the aim of the presented work was to develop a recommended method for measuring the parameters of the EM-field in-situin the work space while using magnetotherapy or magneto stimulation devices.The recommended measurement method is based on detailed investigations on the characteristics of exposure to the EM-field surrounding typical magnetotherapy devices operated in Poland: by approx. 700 applicators of 500 devices (such as Magnetronic (series MF-10, MF-12, MF 20 and BTL), Magnetus (series 2 and 2.26), Magnoter (series D-56, D56A BL), Magner LT, Magner Plus, Magneris, MAG magnetic, Magnetic, Astar ABR).The oscilloscopic identification, the characteristics of variability in the time of the EM-field emitted by devices for magnetotherapy and magneto stimulation, and the measurements of the spatial distribution of the EM-field in the workspace by devices have been worked out. Based on the results of the study, it was shown that, during physiotherapy treatment, only the applicator for magnetotherapy or magneto stimulation is the source of the EM-field. When using an EM-field with a frequency of up to 100 Hz and a continuous sinusoidal or non-sinusoidal waveform –alternating or rectified (i.e. with a constant component) –the range of protective zones of EM-field is deter-mined by the spatial distribution of the quasi-static magnetic field (M-field). Because this type of device predominates in Polish physiotherapy centres, to assess electromagnetic hazards in the workspace, it was recommended to use a simplified method of measurement, involving the measurement of the root-mean-square (RMS) value of the M-field strength in sinusoidal operation mode and an evaluation of results, taking into account the limits reflect-ing the measures of exposure specified in the labour law in relation to the equivalent value of the M-field strength, but using an appropriate correction factor reflecting the need to strengthen the exposure evaluation at non-sinusoidal modes of operation (i.e. by the use of limits set for EM-field of 100 Hz frequency). In the case of devices emitting an EM-field with frequencies in the kilohertz (kHz) range or a pulsed EM-field, it was recommended to use more complex measurements, including an individual analysis of the characteristics of the measured EM-field and a determination of correction factors to the interpretation of the measured RMS value (based on the metrological characteristics of measuring devices used). The method also sets out principles for: measurements and measurement devices preparation, locating the measurement points, determining the range of protection zones and documenting the measurement results. The most important sources of uncertainty concerning EM-field measurements in the workspace near magnetotherapy or magnetic stimulation applicators were also discussed.
PL
W pracy przedstawiono charakterystykę wielomiejscowego zespołu odruchowego typu I. Na przykładzie jednego chorego wskazano na trudności diagnostyczne i możliwość wykorzystania badania termowizyjnego do diagnostyki i monitorowania leczenia rehabilitacyjnego z wykorzystaniem pola elektromagnetycznego. Do oceny rozkładu wartości temperatury zastosowano kamerę termowizyjną.
EN
The paper presents the characteristics of the Complex Regional Pain Syndrome type I. In the article observations on one patient are presented. This study shows diagnostic difficulties and possibility of using an infrared studies for diagnosis and monitoring of treatment with electromagnetic field. For temperature evaluation the thermal camera was used.
PL
W artykule dokonano analizy zasięgu strefy, w której przekroczone są zalecane poziomy dopuszczalne pola magnetycznego od urządzeń generujących pole magnetyczne, tj. aplikatorów stosowanych w magnetoterapii. Poziomy dopuszczalne w poszczególnych pasmach rozpatrywano zarówno na podstawie zaleceń dla miejsc ogólnodostępnych, jak i dla stanowisk pracy. Analizowany jest również wpływ wymuszeń zawierających wyższe harmoniczne. Zasięg stosownych stref od urządzenia generującego pole magnetyczne odniesiono do rozmiarów potencjalnego pacjenta.
EN
The article outlines the extent of the zone, within the appropriate recommendations concerning the level of the magnetic field from devices that generate magnetic field are unfulfilled, i.e. applicators used in magnetotherapy. Limits on individual bands were considered both based on the reference levels for occupational exposure to time varying magnetic fields and for general public exposure. The impact of distorted signals containing higher harmonics is also analyzed. The range of relevant zones for equipment that generates a magnetic field, are related to the extents of the potential patient.
17
PL
Wpływ pola elektromagnetycznego na organizmy żywe budził od dawna zainteresowanie wielu naukowców. Przeprowadzone badania nad wykorzystaniem terapeutycznym wolnozmiennych pól magnetycznych obejmują różne doświadczenia, począwszy od badań submolekularnych do eksperymentów na zwierzętach doświadczalnych. Największą dynamiką charakteryzują się jednak badania kliniczne. Zastosowanie zmiennych pól magnetycznych w terapii mieści się w ramach specjalizacji medycznej noszącej nazwę medycyny fizykalnej. W tej dziedzinie zdecydowanie nie powiedziano jednak jeszcze ostatniego słowa. Rozwój medycyny i postęp technologiczny pozwala na stworzenie nowych urządzeń wykorzystywanych w magnetoterapii. Stwarza to nowe możliwości leczenia. Małogabarytowe cewki aplikatorów mogą być stosowane w warunkach domowych. Z kolei wizualizacja wnikania pola do kończyny pozwoli dobrać kształt aplikatora do rodzaju leczonej choroby oraz do kształtu i wymiarów uszkodzonego miejsca ciała.
EN
The influence of electromagnetic field on living organisms has been of interest to scientists for centuries. The researches on the therapeutic effect of low-frequency magnetic fields cover various experiments: from submolecular mechanisms analyses to laboratory experiments on animals. However, the clinical experiments turned out to be most dynamic. The therapeutic use of low-frequency magnetic fields stays within the domain of the so-called physical medicine. Still much is to be done in this respect. The evolution of medicine and technological development allows for creating new devices applied in magnetotherapy, which opens up new possibilities for treating diseases. There are small coil applicators which can be used at home. Moreover, the visualization of field penetration through the limb may be helpful when selecting the most desirable shape of the applicator in view of the type of the disease, shape and size of the damaged part of the body.
PL
Artykuł przedstawia wyniki badania wartości temperatury wybranego obszaru ciała poddanego działaniu jednorazowej ekspozycji pola elektromagnetycznego w dawkach stosowanych w magnetoterapii i magnetostymulacji. Badanie przeprowadzono u 30 młodych zdrowych osób wykorzystując urządzenia stosowane w fizykoterapii. Do oceny temperatury zastosowano kamerę termowizyjną firmy. Badania termowizyjne wykonane po ekspozycji pola elektromagnetycznego nie wykazują istotnej zmiany wartości temperatury badanego obszaru.
EN
The article presents the results of the temperature measurements of the selected area of the body treated with a single exposure to electromagnetic field in the doses which are used in the magnetotherapy and magnetostimulation. The study was conducted on a group of 30 young healthy volunteers using the devices which are commonly used in electromagnetic physiotherapy. To evaluate the temperature thermal camera was used. Thermal imaging study which were performed after the exposure to the electromagnetic field do not show a significant change in the temperature of the examined area.
PL
W artykule przedstawiono metodę określania budowy i usytuowania aplikatora eliptycznego. Założono, że należy uzyskać jak najwyższą wartość indukcji pola magnetycznego w punktach kontrolnych związanych z wybraną strukturą anatomiczną, przy jednoczesnym zachowaniu wartości indukcji pola magnetycznego w bezpiecznych granicach w otoczeniu rozrusznika serca. Wyniki uzyskano z zastosowaniem algorytmu genetycznego. Omówiono również inne możliwe efekty oddziaływania aplikatora na rozrusznik serca.
EN
This paper presents a method for determining the structure and location of the elliptical applicator. It is assumed that the highest value of magnetic flux density at checkpoints associated with the selected anatomical structure are obtained, with simultaneous preservation of inductance within safe limits in vicinity of pacemaker. The results were obtained using genetic algorithm. It also discusses the impact of other possible effects on cardiac pacemaker.
PL
Terapia polem magnetycznym znajduje szerokie zastosowanie w medycynie zarówno w terapii, jak i w diagnostyce. W artykule autorzy przedstawiają sygnały stosowane w terapii polem magnetycznym o małej indukcji i małej częstotliwości oraz przedstawiają ich analizę.
EN
Magnetic field therapy is widely used in medicine, both in therapy and in diagnostics. In this paper the authors present the signals used in the treatment by low intensity and low frequency magnetic field and present their analysis.