The research focused on one–week long measurement of power quality parameters at the connection point of a 450 kW charging station (pantograph type) in the distribution substation. The bus terminal was equipped with 1200 kVA 15.75/0.42 kV Dyn 5 transformer. The Solaris Urbino 12 electric buses were used for the tests.The device used for the measurements was Sonel PQM–711 class A power quality analyser. The measurements showed a full compliance with the PN–EN 50160 2010 standard.
PL
Badania koncentrowały się na jednotygodniowym pomiarze parametrów jakości energii elektrycznej w punkcie przyłączenia pantografowej stacji ładowania o mocy 450 kW w podstacji transformatorowej. Przy pętli autobusowej znajdował się transformator Dyn5 o mocy pozornej 1250 kVA i przekładni 15,75/0,42 kV. Do badań wykorzystano autobusy Solaris Urbino 12 electric. Parametry jakości energii elektrycznej mierzono analizatorem Sonel PQM–711 (klasa A). Pomiary wykazały pełną zgodność z normą PN–EN 50160:2010.
2
Content available Power quality in the circuits of traction substation
EN
Rail transport in Poland uses direct current electric traction to power vehicles (locomotives and multiple units). It is therefore necessary to convert the AC voltage of the power system into the DC voltage of the traction system. The conversion of alternating voltage into direct voltage takes place in traction substations. Rectifier units installed at traction substations are used for this purpose. As a result, electric traction should be classified as non-linear consumers. In addition, the traction substation load changes dynamically. All this makes the electric traction a recipient generating a number of disturbances to the network. These disturbances affect the quality of electricity in the power system from which the traction substations are supplied, and the quality of energy in auxiliary and non-traction lines. The article presents the results of the analysis of measurements of electricity quality indicators recorded at selected points of the traction substation line. Parameters characterizing the quality of electricity were recorded, among others, in in the main line supplying the traction substation, non-traction needs line and auxiliary circuits. The presented article is another in a series of publications related to the assessment of the impact of DC electric traction on the power system.
PL
Transport kolejowy w Polsce wykorzystuje do zasilania pojazdów (lokomotyw i zespołów trakcyjnych) trakcję elektryczną prądu stałego. Konieczne jest zatem przekształcenie napięcia przemiennego systemu elektroenergetycznego na napięcie stałe systemu trakcyjnego. Zamiana napięcia przemiennego na napięcie stałe odbywa się w podstacjach trakcyjnych. Wykorzystywane do tego celu są zespoły prostownikowe zainstalowane na podstacjach trakcyjnych. Sprawia to, że trakcję elektryczną zaliczyć należy do obiorców o charakterze nieliniowym. Dodatkowo obciążenie podstacji trakcyjnej zmienia się w sposób dynamiczny. Wszystko to powoduje, że trakcja elektryczna jest odbiorcą generującym do sieci szereg zaburzeń. Zaburzenia te wpływają na jakości energii elektrycznej systemu elektroenergetycznego, z którego zasilane są podstacje trakcyjne oraz jakość energii w liniach potrzeb własnych i potrzeb nietrakcyjnych. Artykuł przestawia wyniki analizy pomiarów wskaźników jakości energii elektrycznej zarejestrowanych w wybranych punktach linii podstacji trakcyjnych. Parametry charakteryzujące jakość energii elektrycznej zarejestrowano m.in. w głównej linii zasilającej podstację trakcyjną, linii potrzeb nietrakcyjnych oraz obwodach potrzeb własnych. Prezentowany artykuł jest jednym z cyklu publikacji związanych z oceną oddziaływania trakcji elektrycznej prądu stałego na system elektroenergetyczny.
PL
Obszar działania Komitetu Studiów C4 jest bardzo szeroki, dotyczy zarówno zjawisk, metodyk jak i narzędzi do analiz różnych kwestii funkcjonowania systemu elektroenergetycznego, w tym: jakości energii elektrycznej, kompatybilności elektromagnetycznej (EMC), dynamiki pracy systemów elektroenergetycznych, wyładowań atmosferycznych i koordynacji izolacji. Na sesję CIGRE 2022 w Paryżu Komitet C4 wytypował trzy tematy preferowane: PS1: Wyzwania i osiągnięcia w zakresie jakości energii (PQ) i kompatybilności elektromagnetycznej, PS2: Wyzwania i osiągnięcia w koordynacji izolacji i badaniach nad wyładowaniami atmosferycznymi, PS3: Wyzwania i osiągnięcia w dynamice systemu elektroenergetycznego. Spośród nadesłanych publikacji na sesję CIGRE zaakceptowanych zostało 59 referatów. W artykule przedstawiono charakterystykę tych referatów.
EN
The area of the Study Committee C4 activity is very wide and concerns occurrences, methodologies and tools to analyse various issues referring to a power system functioning including power quality performance, electromagnetic compatibility (EMC), power system dynamics, lightnings and insulation co-ordination. Three preferential subjects were selected by the Committee C4 for the CIGRE Session 2022 in Paris. They were: PS1 - Challenges and achievements in the power quality (PQ) and electromagnetic compatibility (EMC), PS2 - Challenges and achievements in insulation co-ordination and in research of lightnings, PS3 - Challenges and achievements in power system dynamics. From among all submitted publications only 59 were accepted to be presented during the CIGRE Session. Depicted are characteristics of these papers.
EN
The use of non-linear devices causes unfavourable changes in the operation of the power system. First of all, they are a source of higher harmonics in network waveforms, which tend to increase the eddy currents. Their effect consists in raising the temperature of transformer cores. This, in turn, translates into their failure rate and fire safety, including reducing the actual value of rated power. The article describes the results of experimental studies carried out on a large scale. An analysis was performed of the quality of electric power depending on the type of network load. The results have shown that the increase in the use of non-linear receivers such as LED lighting, electronic chargers, inverters, etc. may have a tangible impact on the fire hazard of distribution transformers. Examples of calculations have been presented, which prove the necessity of taking into account the influence of higher harmonics on the reduction of the real rated power of power transformers.
PL
Użytkowanie urządzeń o charakterze nieliniowym wprowadza niekorzystne zmiany w funkcjonowaniu systemu elektroenergetycznego. Przede wszystkim są one źródłem wyższych harmonicznych w przebiegach sieciowych, co wpływa na zwiększenie prądów wirowych. Ich oddziaływanie sprowadza się do podnoszenia temperatury rdzeni transformatorów. To z kolei przekłada się na ich awaryjność i bezpieczeństwo pożarowe, w tym na obniżenie rzeczywistej wartości mocy znamionowej. Artykuł opisuje wyniki badań doświadczalnych przeprowadzonych w dużej skali. Analizie poddano jakość energii elektrycznej w zależności od rodzaju obciążenia sieci. Wyniki pozwalają stwierdzić, że wzrost wykorzystania nieliniowych odbiorników takich jak: oświetlenie LED, ładowarki elektroniczne, przetwornice częstotliwości itp. może realnie wpływać na zagrożenie pożarem transformatorów rozdzielczych. Przedstawiono przykładowe obliczenia, które dowodzą konieczności uwzględnienia wpływu wyższych harmonicznych na obniżenie rzeczywistej mocy znamionowej transformatorów energetycznych.
PL
W pracy przedstawiono wyniki pomiarów ilustrujących właściwości wybranych lamp z punktu widzenia sieci elektroenergetycznej. Do badań wybrano lampę halogenową, świetlówkę kompaktową oraz 3 różne lampy LED. Przedstawiono zastosowany układ pomiarowy oraz zmierzone przebiegi czasowe oraz widma częstotliwościowe prądu zasilającego badane lampy. Wyznaczono i przedyskutowano wartości wybranych parametrów charakteryzujących wpływ tych lamp na sieć elektroenergetyczną.
EN
The paper presents the results of measurements illustrating the properties of selected lamps from the point of view of the power grid. A halogen lamp, a compact fluorescent lamp and 3 different LED lamps were selected for the investigations. The applied measuring system as well as the measured waveforms and frequency spectra of the current supplying the tested lamps are presented. The values of selected parameters characterizing the influence of these lamps on the power grid were measured and discussed.
PL
Wzrost udziału elektronicznych i energoelektronicznych urządzeń w zakładach przemysłowych prowadzi do pogorszenia parametrów Jakości Energii Elektrycznej. Powoduje to występowanie określonych, negatywnych skutków dla urządzeń elektrycznych. Przeciwdziałać tym skutkom można dzięki zastosowaniu filtrów aktywnych. Pozwalają one w znaczący sposób wpłynąć na Jakość Energii Elektrycznej w zakładzie. Wybrane modele w wykonaniu modułowym pozwalają na dostosowanie samego urządzenia do rzeczywistego zapotrzebowania na ich moc.
EN
The increase in the proportion of electronic and power electronic devices in industry leads to a deterioration of the Power Quality parameters. This causes specific negative effects on electrical equipment. These effects can be counteracted by using active filters. They make it possible to significantly influence the Power Quality in a plant. Selected models in modular design allow the unit itself to be adapted to the actual demand.
PL
Artykuł omawia wybrane zagadnienia jakości energii elektrycznej w układach z zasilaczami UPS z uwzględnieniem kształtu przebiegów wyjściowych.
EN
The article discusses selected issues of electric power quality in systems with UPS power supplies, taking into the shape of the output waveforms.
EN
Striving for the so-called climate neutrality, i.e. the reduction of carbon dioxide emissions resulting, inter alia, from the production of electricity, is now a great opportunity for the development of widely understood sources of distributed generation, such as wind farms or photovoltaic farms. These sources, however, are characterized by high variability and a work profile that is difficult to predict, which may adversely affect the power grid to which they are connected. The purpose of the research described in this article is to assess the impact of the reconfiguration of the MV network with distributed generation on the voltage values in its nodes. The article describes the course of research and the results of simulation tests for the real existing 15 kV distribution grid with different variants of generation units and loads.
PL
Dążenie do tzw. neutralności klimatycznej, czyli redukcja emisji dwutlenku węgla powstającej między innymi wskutek produkcji energii elektrycznej jest obecnie dużą szansą dla rozwoju szeroko rozumianych źródeł generacji rozproszonej, takich jak farmy wiatrowe czy fotowoltaiczne. Źródła te charakteryzują się jednak dużą zmiennością i trudnym do przewidzenia profilem pracy, co może niekorzystnie wpływać na sieć elektroenergetyczną, do której są podłączone. Celem badań opisanych w niniejszym artykule jest ocena wpływu rekonfiguracji sieci SN, w której występuje generacja rozproszona, na wartości napięć w jej węzłach. Opisano przebieg badań i podano wyniki eksperymentów symulacyjnych rzeczywistej, istniejącej sieci 15 kV, z różnymi wariantami pracy jednostek wytwórczych i różnymi obciążeniami sieci.
PL
W artykule przedstawiono jednofazowy filtr aktywny z zasobnikiem energii dwukierunkowym przekształtnikiem DC/DC, dedykowanym do kompensacji udarów mocy czynnej generowanych przez nieliniowe obciążenia o pracy przerywanej. Jako obiekt kompensacji użyto jednofazową zgrzewarkę punktową. Praca zawiera kompleksową analizę pracy urządzenia, która umożliwiła opracowanie aparatu matematycznego wykorzystanego do wymiarowania zasobnika. Wysoką skuteczność rozwiązania potwierdzono w wyniku badań symulacyjnych oraz eksperymentalnych na zrealizowanym modelu laboratoryjny urządzenia. W części 1 artykułu przedstawiono zasadę działania, wyniki analiz teoretycznych oraz dobór podstawowych parametrów w układu.
EN
This paper presents a single-phase power filter with an energy storage bidirectional DC/DC converter. The device is dedicated to the compensation of active power surges generated by nonlinear loads characterized by intermittent operation. As a compensated and filtered object, the single-phase spot welding machine was assumed. The work contains a comprehensive analysis of the device's operation, which enabled the development of storage sizing methodology. The high efficiency of the solution was confirmed during simulation and experimental approach, on especially developed laboratory model. Part 1 of the article presents the principle of operation, results of theoretical analyzes and the selection of basic parameters in the system.
PL
W artykule przedstawiono jednofazowy filtr aktywny z zasobnikiem energii dwukierunkowym przekształtnikiem DC/DC, dedykowanym do kompensacji udarów mocy czynnej generowanych przez nieliniowe obciążenia o pracy przerywanej. Jako obiekt kompensacji użyto jednofazową zgrzewarkę punktową. Praca zawiera kompleksową analizę pracy urządzenia, która umożliwiła opracowanie aparatu matematycznego wykorzystanego do wymiarowania zasobnika. Wysoką skuteczność rozwiązania potwierdzono w wyniku badań symulacyjnych oraz eksperymentalnych na zrealizowanym modelu laboratoryjny urządzenia. W części 2 artykułu przedstawiono wyniki badań symulacyjnych, oraz rezultaty eksperymentu.
EN
This paper presents a single-phase power filter with an energy storage bidirectional DC/DC converter. The device is dedicated to the compensation of active power surges generated by nonlinear loads characterized by intermittent operation. As a compensated and filtered object, the single-phase spot welding machine was assumed. The work contains a comprehensive analysis of the device's operation, which enabled the development of storage sizing methodology. The high efficiency of the solution was confirmed during simulation and experimental approach, on especially developed laboratory model. Part 2 of the article presents the results of simulation studies and the results of the experiment.
EN
The Smart Grid environment gives more benefits for the consumers, whereas the power quality is one of the challenging factors in the smart grid environment. To protect the system equipment and increase the reliability, different filter technologies are used. Even though, consumers’ expectations towards the power quality are not fulfilled. To overcome these drawbacks and enhance the system reliability, a new Custom Power Devices (CPD) are introduced in the system. Among different CPDs, the Dynamic Voltage Restorer (DVR) is one of the voltage compensating devices that is used to improve the power quality during distortions. When the distortions such as voltage swell and sag occur in the distribution system, the control strategy in the DVR plays a significant role. In this article, the DVR performance using Proportional Integral (PI), Proportional Resonant (PR) controllers are analyzed. A robust optimization algorithm called Self Balanced Differential Evolution (SBDE) is used to find the optimal gain values of the controllers in order to reach the target of global minimum error and obtain fast response. Then, a comparative analysis is performed between different controllers and verified that the performance of PR controller is superior than the other controllers. It has been found that the proposed PR controller strategy reduces the Total Harmonic Distortion (THD) values for all types of faults. The proposed SBDE optimized DVR with PR controller reduces the THD value less than 4% under voltage distoration condition. The DVR topology is validated in MATLAB/SIMULINK in order to detect the disturbance and inject the voltage to compensate the load voltage.
PL
Zagadnienia tematyczne Komitetu Studiów C4 reprezentowane były na konferencji CIGRE w 2020 roku w 65 referatach. Podstawowe obszary aktywności Komitetu Studiów C4 na tej sesji zostały określone w trzech tematach preferowanych: poprawa wydajności technicznej SEE poprzez zastosowanie zaawansowanych metod, modeli i narzędzi; modelowanie przyszłej sieci elektroenergetycznej na podstawie wniosków wyciągniętych ze zdarzeń systemowych; metody, modele i techniki oceny wyładowań atmosferycznych, jakości energii i koordynacji izolacji w celu poprawy wydajności rozwijającej się sieci. Generalnie poruszone zagadnienia dotyczyły obecnych oraz przyszłych uwarunkowań technicznych pracy SEE i koncentrowały się w szczególności na: zjawiskach występujących w SEE cechujących się wysokim poziomem nasycenia źródeł bazujących na układach przekształtnikowych (IBR. ang. Inwerter Base Resource); metodykach analiz dynamicznych prowadzonych dla systemów cechujących się dużym nasyceniem IBR oraz zakłóceń elektromagnetycznych i indukowanych prądów geomagnetycznych; oceny bilansu mocy systemu i stabilności częstotliwości za pomocą analityki „Big Data”; rozwoju pojawiających się mierników i narzędzi do ilościowego określania niezawodności, odporności i elastyczności SEE, w tym z układami HVDC. Przytoczone zagadnienia podkreślają bardzo szeroki zakres zainteresowań i badań realizowanych w obszarze Komitetu Studiów C4. Przewiduje się, że poruszane w artykule kwestie staną się coraz bardziej powszechne i wymuszą istotne zmiany w dotychczasowym podejściu do kształtowania SEE.
EN
Subject matters of the Study Committee C4 were presented on CIGRE 2020 conference in 65 papers. Main areas of this Committee activity were defined in three preferential themes: improvement of an EPS (Electric Power System) technical performance by the use of advanced methods, models and tools; modelling of a future power network basing on conclusions drawn from system events; methods, models and technologies for evaluation of lightning discharges, power quality and insulation coordination to enhance an evolving grid performance. In general, the raised issues concerned the present and the future technical conditions of EPS operation and particularly focused on phenomena occurring in EPS characterized by high penetration level of resources basing on inverter systems (IBR – Inverter Base Resource; methodologies of dynamic analyses conducted for systems characterized by high penetration of IBR as well as electromagnetic disturbances and geomagnetic induced currents; evaluation of a system power balance and frequency stability with the use of the "Big Data" analytics; development of emerging measuring devices and tools for quantifying reliability, resilience and flexibility of an EPS including HVDC systems. The above mentioned problems emphasize that C4 Studies Committee has a very wide range of interests and research. It is expected that the problems discussed in this article will become more and more common and will force significant changes in the current approach to EPS shaping.
PL
W artykule przedstawiono wpływ oświetlenia LED na jakość pobieranej energii elektrycznej. LED-owe źródła światła zostały podzielone na trzy podstawowe grupy. Pierwsza, to oświetlenie domowe, do których zaliczamy różnego rodzaju wymienne żarówki. Druga grupa, to oprawy przemysłowe stosowane w biurach, zakładach przemysłowych, czy w budynkach użyteczności publicznej. Trzecia grupa, to oprawy stosowane do oświetlenia zewnętrznego ulic, skrzyżowań, chodników, parków. Przetestowano kilkanaście różnego rodzaju źródeł LED-owych, w których zmierzono prąd, napięcie oraz moc czynną, bierną i pozorną podstawowej harmonicznej, jak również wyższe harmoniczne prądów i napięć. Na tej podstawie sporządzono wykresy procentowej zawartości wyższych harmonicznych prądów oraz THDi pobieranego z sieci elektroenergetycznej. Przedstawiono przesunięcia kąta fazowego pomiędzy napięciem i prądem dla podstawowej harmonicznej skutkującym poborem mocy biernej pojemnościowej. Zarejestrowano również przebiegi prądów i napięć pokazujące nie tylko odkształcenie prądu, ale również charakterystykę rozruchu opraw przemysłowych i drogowych.
EN
The article presents the impact of LED lighting on the quality of electricity consumed. LED light sources have been divided into three basic groups. The first is home lighting, which includes various types of replaceable bulbs. The second group includes industrial luminaires used in offices, industrial plants or public utility buildings. The third group includes luminaires used for outdoor lighting of streets, crossroads, sidewalks and parks. A dozen or so different types of LED sources were tested, in which the current, voltage and active, reactive and apparent power were measured, as well as the higher harmonics of currents and voltages. On this basis, graphs of the percentage of higher harmonic currents and THDi collected from the power grid were drawn up. The phase angle shifts between voltage and current for the fundamental harmonic, resulting in the consumption of capacitive reactive power, are presented. Current and voltage waveforms were also recorded, showing not only the current distortion, but also the starting characteristics of industrial and road luminaires.
PL
W artykule przedstawiono zalety budowania rolniczych elektrowni biogazowych oraz problematykę związaną z przyłączaniem ich do sieci dystrybucyjnej.
EN
The article presents the advantages of building agricultural biogas plants as well as problems related to connecting them to the distribution network.
PL
Materiał przedstawiony w artykule dotyczy zagadnień analizy imetod poprawy wybranych wskaźników jakości energii elektrycznej. Przedstawiono w nim częściowe wyniki prac realizowanych w ramach projektu dotyczącego rozproszonego systemu poprawy jakości energii elektrycznej. Tematycznie projekt związany jest z dwoma bardzo ważnymi parametrami jakości energii elektrycznej jakimi są zawartość wyższych harmonicznych w przebiegach prądów i napięć oraz moc bierna pobierana z sieci zasilającej. Proponowany system to połączenie oprogramowania z rozwiązaniami technicznymi, które będą prowadzić do poprawy warunków pracy urządzeń, obniżenia strat oraz stabilności i bezpieczeństwa sieci zasilających.
EN
The content of the article concernsanalysis and method of improvement of selected parameters of power quality. It presents the partial results of the project consisting in the development of a distributed system for power quality improvement. The project is focused on two very important power quality parameters, i.e. higher harmonics in current/voltage waveforms and reactive power delivered by supplying network. These two negative phenomena cause the increase of losses in the power system and simultaneously the decrease of the system power factor. As result of the project, devices used for reactive power compensation and filtration of supplying current higher harmonic as well as a software for optimal choice and placement of these devices in the power system will be developed.
PL
Operatorzy elektroenergetycznych systemów dystrybucyjnych w Polsce zainstalowali w swoich sieciach kilkadziesiąt tysięcy bilansujących liczników energii elektrycznej wyposażonych, zgodnie z wymaganiami Urzędu Regulacji Energetyki, w funkcje pomiaru wskaźników jakości dostawy energii elektrycznej. Liczniki te oferują nowe możliwości oceny jakości napięcia oraz diagnostyki sieci dystrybucyjnych, będąc źródłem istotnego wolumenu danych pomiarowych. Artykuł prezentuje możliwości wykorzystania wyników pomiarów agregowanych w okresach 10minutowych, pochodzących z rozproszonego systemu pomiarowego (składającego się z dużej liczby liczników i i małej liczby analizatorów) w lokalizacji dominujących źródeł zaburzeń w elektroenergetycznej sieci dystrybucyjnej.
EN
In recent years, electricity distribution system operators in Poland have installed tens of thousands of balancing electricity meters, in accordance with the requirements of the Energy Regulatory Office, with the function of measuring the quality of electricity supply indicators. These meters offer new possibilities in the assessment of functioning and diagnostics of power distribution systems. The article presents the possibility of using aggregated 10-minute power quality measurement data from dispersed electricity meters to locate dominant sources of disturbances in the power distribution network.
PL
Artykuł zawiera wykorzystanie eksploracji danych w analizie parametrów określających jakość energii elektrycznej (JEE) pod kątem identyfikacji danych podlegających regule oznaczania w rozumieniu normy PN EN 61000-4-30. Zaprezentowano możliwość wykorzystania analizy skupień jako narzędzia umożliwiającego podział zagregowanych danych pomiarowych na grupy reprezentujące wyniki pomiarów wolne od zdarzeń napięciowych oraz wyniki pomiarów, w trakcie których wystąpiło zdarzenie napięciowe. Artykuł zawiera wyniki badań wrażliwości wybranego algorytmu analizy skupień (k-średnich) na identyfikację danych zawierających przerwy, zapady, wzrosty oraz szybkie zmiany napięcia. Za zbiór danych testowych wykorzystano synchroniczne pomiary przeprowadzone w sieci zakładów górniczych. Uzyskane wyniki pozwalają na określenie skuteczności wykorzystania analizy skupień do identyfikacji danych zagregowanych zawierających zdarzenia napięciowe w ujęciu obszarowym. Badanym obszarem jest sieć elektroenergetyczna zasilająca wybrany zakład górniczy wydobywający rudy miedzi na Dolnym Śląsku.
EN
The article presents the use of data mining to power quality issue. The possibility to using cluster analysis as an appreciate tool to realize division into groups representing the measurement period for which aggregated data (within the meaning of PN EN 61000-4-30 standard) contain and do not contain aggregated voltage events is presented. The K-means algorithm sensitivity test to the identification of data containing interruptions, dips, increases and rapid voltage changes was presented. Synchronous measurements carried out in the mining plant network were used for the test data set. The obtained results allow determining the effectiveness of using cluster analysis to identify aggregated data containing voltage events. The area-related in this article is electrical power network of copper mining industry in Lover Silesia.
PL
W polskich zakładach górniczych napędy maszyn wyciągowych napędzane są głównie przez silniki obcowzbudne prądu stałego. Regulacja prędkości takiego silnika odbywa się dzięki zastosowaniu przekształtników statycznych. Oprócz niewątpliwych zalet tego typu napędu, coraz częściej dostrzegany jest negatywny wpływ tego typu napędów na sieci elektroenergetyczne kopalń. Dlatego poszukuje się możliwości ograniczenia negatywnych skutków pracy takiego napędu przez zastosowanie m.in. przekształtników złożonych. W artykule przedstawiono analizę doboru liczby pulsów układu przekształtnikowego maszyny wyciągowej pod kątem sprawności układu oraz jego oddziaływania na sieć zasilającą.
EN
In Polish mining plants the drives of hoisting machines are mainly made by separately excited DC motors. The speed of such a motor is regulated by the use of static converters. In addition to the unquestionable advantages of this type of drive, its negative impact on the power networks of mines is increasingly being noticed. Therefore, it is sought to limit their negative effects by using, e.g. complex converters. In this article the selection of the number of pulses of the hoisting machine converter system in terms of system efficiency and its impact on the supply network is presented.
PL
Kontrola jakości dostawy energii elektrycznej w systemie dystrybucyjnym wiąże się z koniecznością ciągłych pomiarów analizatorami jakości energii w wielu miejscach tej sieci. Pojawia się wobec tego problem takiego wyboru miejsc pomiaru, aby ograniczyć liczbę mierników do niezbędnego minimum. W artykule opisano trzy metody wyboru miejsc przyłączenia analizatorów jakości energii elektrycznej w sieci dystrybucyjnej. Przedstawiono również wyniki aplikacji tych metod do sieci testowej IEEE 37-węzłowej.
EN
Verification of supply quality in distribution system involves the need of continuous measurements with power quality meters in large number of nodes of that network. There is the need of a method of selecting such nodes so the number of meters is minimal. The article describes three methods for selecting points of installation of power quality meters. Application of the methods to a IEEE 37-node test feeder is also presented.
PL
W artykule opisano zjawiska zachodzące w obwodzie wielkoprądowym elektrycznego pieca łukowego AC. Odwzorowano wpływ zmian długości kolumny łukowej na parametry modelu matematycznego Pentegowa łuku elektrycznego wykorzystującego statyczną charakterystykę napięciowo-prądową. W wyniku symulacji otrzymano dynamiczne charakterystyki napięciowo-prądowe łuków elektrycznych. Na podstawie analizy danych pomiarowych przedstawiono wpływ asymetrii i zaburzeń łuku na jakość energii elektrycznej w układzie zasilania AC-EAF.
EN
The article describes the phenomena occurring in the high-current circuit of an AC electric arc furnace. The effect of changes in the arc column length on the parameters of the Pentegov mathematical model of the electric arc based on static voltage-current characteristics is mapped. As a result of the simulation, dynamic voltage-current characteristics of electric arcs were obtained. Based on the analysis of measurement data, the effect of asymmetry and arc disturbances on the quality of electricity in the AC-EAF power system is presented.