Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  industrial wastewater treatment
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Microbiological biopreparations as biotechnological methods support wastewater treatment processes. Unfortunately, in conditions with a short hydraulic retention time (up to 22 hours) in wastewater treatment plants, biological treatment processes are not able to effectively reduce the concentrations of COD, BOD5, and nutrients in the sewage. The authors tested both biopreparations with consortia of autochthonous and allochthonous microorganisms, and in both cases, no significantly significant differences in treatment efficiency were found compared to the control group (without the addition of biopreparations).
PL
Biopreparaty mikrobiologiczne jako metody biotechnologiczne wspomagają procesy oczyszczania. Niestety w warunkach oczyszczalni z krótkim HRT (do 22 godzin), procesy biologicznego oczyszczania nie są w stanie efektywnie redukować stężeń ChZT, BZT5, oraz biogenów w ściekach. Autorzy testowali zarówno biopreparaty z konsorcjami mikroorganizmów autochtonicznych oraz allochtonicznych, w obu przypadkach nie wykazano znacząco istotnych różnic w efektywności oczyszczania w porównaniu z grupą kontrolną (bez dodatku biopreparatów).
PL
Przedstawiono badania dotyczące przydatności siedmiu polielektrolitów w procesie klarowania szlamu pochodzącego z zakładu produkcji wapienniczo-kamiennej oraz weryfikacji jakości działania. Badania obejmowały przygotowanie polielektrolitów w celu weryfikacji ich efektywności działania w procesie flokulacji szlamu pochodzącego z zakładu, badania procesu flokulacji zawiesiny w warunkach statycznych, jak również wyznaczenie współczynnika lepkości dynamicznej wody nadosadowej uzyskanej po procesie sedymentacji sflokulowanej zawiesiny.
EN
7 com. flocculants in doses of 0.5, 1, 2, 3, 4 and 8 ppm were introduced sep. into the slurry and mixed rapidly for 1 min and slowly for 5 min, then allowed to sediment for 5 min. The samples of the supernatant liquid were analyzed for dynamic viscosity and turbidity. The recommended value of the concn. of polyelectrolytes was 2-4 ppm.
PL
Artykuł przybliża tematykę oczyszczania ścieków przemysłowych przy użyciu flotatorów ciśnieniowych. Wybór flotatora zależy od rodzaju oraz ilości zanieczyszczeń, które mają być usunięte. Skład ścieków wpływa na skuteczność podczyszczenia. Możliwe redukcje ChZT wahają się od 30 do 90%, zaś zawiesiny oraz tłuszczy do 95%.
PL
Postęp w dziedzinie transportu doprowadził do konieczności dbania o estetyczny wygląd i czystość eksploatowanych pojazdów efektem czego istnieje potrzeba tworzenia myjni samochodowych. Przedsięwzięcia te oddziałują na środowisko naturalne i poć gają za sobą wzrost zużycia wody na cele mycia środków transportu, czego następstwem jest także wzrost ilości odprowadzany ścieków z tej gałęzi gospodarki. Ścieki odprowadzane z myjni samochodowych zaliczane są do ścieków przemysłowych. Decydującym kryterium jest charakter zanieczyszczeń ścieków. Aby myjnia mogła funkcjonować, musi spełniać określone wymogi w zakresie odprowadzania ścieków oraz w zakresie wytwarzania odpadów.
EN
The article presents the possibilities and directions of natural bentonite application in the industrial wastewater technology. The food industry, and electromechanical as well as chemical industries were presented as the examples. On the basis of the selected cases, the advisability of natural bentonite application in wastewater treatment technology has been assessed. The analysis included the possible ecological effect, economics of the process and the sludge management.
6
Content available remote Badanie możliwości zagospodarowania osadów ściekowych z pralni przemysłowej
PL
Przedstawiono wyniki badań dotyczących możliwości zagospodarowania osadów powstających podczas oczyszczania ścieków przemysłowych pralniczych, na przykładzie pralni przemysłowej Fliegel Textilservice w Nowym Czarnowie. Wstępne wyniki badań potwierdziły postawioną hipotezę o możliwości ich przyrodniczego zagospodarowania. Wskazują na to zarówno skład fizykochemiczny powstających osadów, jak i test fitotoksyczności.
EN
Sludge generated during laundry wastewater treatment was compared with sludge from a municipal wastewater treatment plant. They were mixed with furnace ash and studied for pH, cond., dry residue, mineral and org. substances, P, total and ammonia N, as well as for phytotoxicity against white mustard, garden cress and barley. The plant germination was inhibited, but lengths of shoots and roots remained unchanged. The sludge and ashes were recommended for reclamation of mine dumping grounds.
EN
The effectiveness of co-treatment of leachates from an old site of municipal landfill with a dairy industry wastewater in a membrane bioreactor has been investigated. The subjects of the study were leachates collected at the municipal landfill in Tychy and dairy wastewaters from Dairy Plant in Bieruń. The determination of the most effective technological parameters of the process, i.e. activated sludge load and its concentration and types of COD fractions in the reactor influent was made. It was shown that the activated sludge load at the level of 0.06 g COD/(gDM·d) was the highest permissible one among all the investigated loads and the process run effectively within the whole investigated range of concentrations of activated sludge in a bioreactor. It was found that in the treated wastewater, the fraction of easily degradable organic compounds was the dominant one.
EN
The advanced oxidation process with Fenton’s reagent can be used in industrial wastewater treatment, especially for the degradation of not easily biodegradable contaminations. Chemical oxidation of industrial wastewater or other substances as a pre-treatment before biological purification is the most effective method of wastewater treatment. However the Fenton process requires low pH of wastewater and final neutralization with a big amount of iron-containing precipitate. Thes paper presents laboratory experiments dealing with the treatment of adhesive wastewater in an sequencing batch reactor following the Fenton process without final neutralization.
PL
W pracy przedstawiono wyniki badań nad oczyszczaniem ścieków powstających w wyniku odtłuszczania, wytrawiania i chromianowania wyrobów aluminiowych. Badano ścieki powstające bezpośrednio w ww. procesach, ścieki po płukaniu elementów aluminiowych i ścieki produkcyjne łączone. Głównymi zanieczyszczeniami ścieków, wymagającymi usunięcia, były: kwasy mineralne, fluorki, chrom(III i VI), cynk, nikiel i ołów. W wyniku badań ustalono, iż redukcja chromu(VI) za pomocą roztworu FeSO4, a następnie neutralizacja za pomocą mleka wapiennego do pH = 10,0, w obecności polielektrolitu Scanpol 55, zapewnia maksymalny stopień usunięcia ww. zanieczyszczeń i najmniejszą objętość wytrąconego osadu. Stężenie fluorków spadło maksymalnie do 21 mg/l, a stężenia wszystkich metali były < 0,1 mg/l. Stwierdzono, iż oczyszczanie oddzielnie ścieków powstających bezpośrednio w ww. procesach i ścieków z płukania daje lepsze wyniki niż oczyszczanie ścieków łączonych.
EN
The aim of the study was to choose optimal parameters for the treatment of effluents arising from aluminium finishing processes. There are four streams of effluents: - wasted liquors after etching in HF and H2SO4 solution followed by chromate solution treatment (A) - effluents from rinsing of aluminium (B), demineralised and returned to rinsing - effluents from ion exchangers regeneration (C) - combined A + C effluents (D) The concentrations of pollutants in effluents A were as follows: pH = 1,6÷2,26, conductivity 7020÷39800 μS/cm, fluorides 1605÷13836 mg/l, sulphates 3300÷16940 mg/l, Cr(VI) 17÷84 mg/l, Cr total 82,5÷264 mg/l, Zn 5,1÷19 mg/l, Ni 1,96÷7,6 mg/l, Al 0,87÷1,9 mg/l. The same components are present in effluent B, but their concentrations are a few hundred times lower. The first step of the process was Cr(VI) reduction with Na2SO3 or FeSO4 solution, followed by neutralization with NaOH or Ca(OH)2 solution to pH = 8,0, 9,0 and 10,0. The best result was achieved with FeSO4, Ca(OH)2, pH = 10,0 and 5 mg/l of Scanpol 55 as a flocculant. The treatment under these conditions resulted in the lowest concentrations of fluorides, sulphates, metals and lowest conductivity. The lowest fluorides concentration was 21 mg/l. All metals concentrations were < 0,1 mg/l. The same processes conducted with effluents D gave slightly higher final concentrations of these ions. The fact that effluent C has very low concentration of pollutants and effluent D is a combination of effluent A and C resulted in efficient dilution of effluent A. Since better effectiveness of precipitation is observed for condensed effluent, separate purification of effluent A and effluent B is more favorable.
10
Content available remote Anaerobic ammonium nitrogen oxidation in DEAMOX process
EN
The example of an innovative method for the removal of ammonium nitrogen from dewatered digested sludge, landfill leachates and ammonia-rich industrial wastewaters is provided. The process called DEAMOX, is based on anaerobic oxidation of ammonium (Anammox) and on autotrophic denitrification of sulphur, and is an alternative method of conventional nitrification and denitrification
PL
Zaprezentowano przykład nowatorskiej metody usuwania azotu amonowego z wód osadowych wytwarzanych w wyniku przeróbki osadów ściekowych, odcieków ze składowisk odpadów oraz silnie skażonych amoniakiem ścieków przemysłowych. Analizowany proces DEAMOX opiera się na anaerobowym utlenianiu amoniaku (Anammox) oraz autotroficznej denitryfikacji siarkowej i stanowi alternatywę dla klasycznej nitryfikacji/denitryfikacji.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.