Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  impulse method
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Understanding the acoustic properties of the materials used in the construction of wall surfaces, plays an important role in structural and environmental acoustics. There are many research methods for determining the acoustic parameters of building elements, such as the sound absorption coefficient, the sound reflection coefficient, or the sound insulation index determined in the laboratory or in situ. This work focuses on the determination of the sound absorption coefficient and the possibility of its measurement in "in situ" conditions by the impulse response method. The main purpose of the presented research was to check whether it is possible to use the impulse method in a small reverberant room to determine the sound absorption coefficient of a small part of the wall structure.
PL
Przedstawiono liczącą ok. 70 lat historię prac związanych z rozwojem sposobów oceny uziemień wykorzystujących metodę udarową. Pierwsze prace związane z tym zagadnieniem zostały rozpoczęte w połowie ubiegłego wieku na Politechnice Gdańskiej z inicjatywy profesora Stanisława Szpora. Omówiono metodę pomiaru, stosowane kolejne generacje mierników, możliwości oceny uziemień i różne definicje normalizacyjne opisujące właściwości uziemienia mierzone przy prądach udarowych o czasie czoła zbliżonym do czasu rzeczywistego wyładowania piorunowego.
EN
About 70 years of history of works related to the development of methods of earthing assessment using the impulse method is presented. The first work on this issue was started in the middle of the last century at the Gdańsk University of Technology on the initiative of professor Stanisław Szpor. The measurement method, successive generations of meters used, various standardization definitions describing the properties and possibilities of earthing evaluations at impulse currents with a front time similar to the real lightning discharge time are discussed.
PL
Ocena stanu technicznego transformatorów energetycznych ma istotne znaczenie ze względu na funkcje, jaką transformatory spełniają w sieciach elektrycznych, oraz na ich koszt. Dlatego transformatory są poddawane szczegółowym badaniom diagnostycznym. Badania obejmują między innymi stan techniczny uzwojeń. W tym celu stosowana jest metoda analizy odpowiedzi częstotliwościowej, umożliwiająca wykrywanie uszkodzeń uzwojeń. Podstawą analizy są charakterystyki częstotliwościowe funkcji przenoszenia transformatorów. Są one wyznaczane przy zastosowaniu różnych metod. Obecnie prace badawcze w tej dziedzinie są prowadzone w celu doskonalenia kryteriów rozpoznawania charakteru i zakresu zniekształceń uzwojeń badanych metodą analizy odpowiedzi częstotliwościowej. W artykule przedstawiono badania wybranych uszkodzeń uzwojeń transformatorów energetycznych na podstawie analizy odpowiedzi częstotliwościowej wyznaczanej metodą impulsową.
EN
Estimation of technical state of power transformers have essential meaning with regard on the function of transformers in electrical networks and their costs. Therefore transformers are investigated in detail at exploitation conditions. Investigations include among others technical state of windings. To detection of winding failures the frequency response analysis method is used. As a base of analysis the frequency characteristics are used. They are determined by use of different methods. Nowadays scientific investigations in this area are made in purpose to improvement the criterions of character and range of winding deformations by use of the frequency response analysis method. The investigations of selected failures of windings of power transformers on the base of analysis of frequency response determined by use of impulse method are presented in the paper.
PL
Podstawowym parametrem charakteryzującym skuteczność działania uziemienia jest jego rezystancja, a niekiedy rezystancja udarowa lub impedancja. Parametry te stosowane są często zamiennie chociaż wyznacza się je różnymi metodami i często mają one różne wartości liczbowe dla tego samego uziemienia. W artykule przedstawiono różne metody pomiaru tych parametrów oraz zaprezentowano wyniki badań porównawczych wykonanych przy użyciu metody statycznej, wysokoczęstotliwościowej oraz udarowej. Omówiono obszary zastosowań oraz ograniczenia omawianych metod, a także typowe błędy związane z interpretacją wyników i błędy w dobrze metody.
EN
The basic parameter for evaluating the earthing is usually its resistance. Sometimes the earthing properties are described by means of its impulse resistance or impedance. These parameters are determined by different methods and they often have different numerical values for the same earthing. The paper presents different methods for measuring the earthing parameters mentioned above and the results of comparative investigations obtained from the static, high frequency and impulse procedures. The aplication areas and limitations of all the described measurement methods as well as typical mistakes are described. The main reasons for the mistakes are usually wrong interpretations of the obtained results and wrong choice of the measurement method.
6
Content available remote Pomiar wilgotności materiałów sypkich metodą impulsową
PL
Zaprezentowano nową, impulsową metodę pomiaru wilgotności materiałów sypkich. Opisano również prototyp automatycznego urządzenia do pomiaru wilgotności materiałów sypkich metodą impulsową. Zamieszczono wyniki pomiarów wilgotności metodą impulsową dla wybranych materiałów: masy formierskiej oraz gruntu.
EN
A new impulse method of loose material humidity measurement is presented and prototype automatic equipment for humidity measurement using impulse method is described. Results of humidity measurements for selected materials, moulding sand and soil, are included.
PL
Zaprezentowano wyniki badań wpływu zawartości lepiszcza w masie formierskiej na dokładność pomiaru wilgotności masy metodą impulsową. Badaniami objęto przymodelowe masy formierskie stosowane w Wydziale Odlewni Dolnośląskiej Fabryki Maszyn ZANAM-LEGMET w Polkowicach. Na podstawie wyników badań wykazano, że zmiana zawartości lepiszcza w masie w granicach ±0,5% powoduje nieznaczne zmiany położenia charakterystyki pm=f(W), na podstawie której jest dokonywana ocena wilgotności mas formierskich. Oznacza to, że zmiana zawartości lepiszcza w zakresie ±0,5% bardzo nieznacznie wpływa na dokładność pomiaru wilgotności masy. Stwierdzono, że błąd pomiaru wilgotności spowodowały zmianę zawartości lepiszcza w masie nie przekracza wartości ΔW=0,15% H2O. Wykazano także, że dodatek dekstryny do masy formierskiej w ilości 0,25 % nieznacznie wpływa na położenie charakterystyki pm=f(W) w układzie pm-W a zatem nieznacznie wpływa na pomiar wilgotności masy. Nieznaczny wpływ zmiany zawartości lepiszcza w masie formierskiej na dokładność pomiaru wilgotności masy metodą impulsową stanowi jej istotną zaletę.
EN
Results of a research on the influence of binder content on measuring accuracy of moulding sand humidity with impulse method are presented. The research covered the facing sands used in the Foundry Department of the Lower Silesian Machine Factory ZANAM-LEGMET in Polkowice. The experimental results proved that change of binder content within ± 0.5 % results in slight displacement of the pm = f(W) characteristics that made the ground for evaluation of moulding sand humidity. This means that such a change of binder content affects the accuracy of humidity measurement inconsiderably. It has been found that the humidity measurement error caused by the changes of binder content does not exceed the value ΔW = 0.15 % H2O. It has been also proved that an addition of 0.25 % of dextrin to moulding sand slightly affects position of the pm = f(W) characteristics in the pm-W coordinate system and thus slightly affects the humidity measurement. Inconsiderable influence of binder content changes in moulding sand on humidity measurement accuracy with impulse method makes a significant ad-vantage of this method.
8
Content available remote Prototyp urządzenia do pomiaru wilgotności mas formierskich metodą impulsową
PL
Zaprezentowano prototypowe urządzenie do pomiaru wilgotności mas formierskich metodą impulsową. Na podstawie analizy procesu zagęszczania próbek masy formierskiej stwierdzono, że sterowanie pracą szybkobieżnego napędu prasującego umożliwia sterowanie dokładnością pomiaru wilgotności. Wykazano, że zmiana drogi rozbiegu tłoka napędu szybkobieżnego powoduje istotne zmiany monotoniczności zależności [...] w układzie współrzędnych [...], a przez to umożliwia zwiększanie dokładności pomiaru wilgotności masy formierskiej.
EN
Prototype equipment for moulding sand humidity measurement with impulse method is presented. Analysis of the densening process of moulding sand proved that control of the high-speed squeezing drive makes it possible to control accuracy of the humidity measurement. It was demonstrated that the run-up travel of the high-speed drive piston significantly influences monotonicity of the relationships [...] in the [...] coordinate system and thus permits increasing accuracy of the humidity measurement.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.