Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 94

Liczba wyników na stronie
first rewind previous Strona / 5 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  impedance
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 5 next fast forward last
1
Content available remote Determination of the reactance of rail vehicles wheelsets
EN
The article presents issues related to the determination of resistance, impedance, and reactance of rail vehicles wheelsets in relation to applicable standards and regulations. The methodology of conducting this type of test is discussed, and a configured test stand is presented to measure the resistance and impedance of the wheelsets. The uncertainty budget for this type of testing is discussed. Exemplary measurement results are presented and analyzed.
PL
Powszechnie stosowane blachy elektrotechniczne stali krzemowej [15, 16] są zorientowane na ziarno (GO – np. blachy transformatorów anizotropowych) lub niezorientowane na ziarno (NGO – np. blachy izotropowe lub generatorowe). Badaniu poddano blachę typu M130 o wymiarach odpowiadających formatowi A4. Oceniano dwa przypadki zmiany naprężenia w stosunku do geometrycznego środka arkusza blachy jak i wąskiego paska zwijanego w okrąg. Wprowadzono założenie, że poza zakresem odkształceń plastycznych w blasze pozostaje naprężenie szczątkowe w procesie produkcji i montażu np. transformatorów czy maszyn. Wskazano, że istnieje jakościowa zależność między wynikami pomiarów a przewidywaniami analitycznymi. Podjęto próby ilościowej analizy naprężenia na drodze symulacji i pomiaru. Badano związek stanu naprężenia ze zmianami parametrów podatności magnetycznej na stan odkształceń czy deformacji (efekt magnetosprężysty Villariego).
EN
The solid dielectrics used in the capacitors exhibit rather high-frequency relaxations. This means that in the radio-frequency range, the capacitors exhibit a constant capacity. When liquid crystal is put into the capacitors, it is observed that in the radio-frequency range the capacity changes (decreases with frequency). This is due to the fact that liquid crystals exhibit relaxation in the radio-frequency range. In this paper, the formulas for the electricresponse of a low-frequency RC filter with liquid crystal characterized by complex electric permittivity are derived. One Debye-type relaxation is assumed in the calculations. The influence of strengths and relaxation time (frequency) of relaxation mode in liquid crystalon the electric response of low-frequency filters is discussed.
EN
Methods for measuring deposit parameters are often based on a capacitance or conductivity measurement aimed at estimating, e.g. deposit moisture content. In practice, these methods fail for materials with a low degree of homogeneity, a diverse porous structure or high conductivity, e.g. due to a high water content. This article demonstrates an approach that enables a more precise estimation of the parameters of any deposit. The presented method involves the use of a measuring system in a charge amplifier configuration and the application of a technique using lock-in detection or a lock-in voltmeter to determine resistance and capacitance parameters of a deposit based on signals received from the measuring system. This method can be successfully used wherever the test deposit material is highly heterogeneous and contains both dielectric and conductive materials. The article presents an example of a solution to a measuring system using two planar electrodes that can be dimensioned depending on the deposit dimensions. It is followed by a presentation of a method for converting the signal from the measuring system into impedance parameters of the deposit using a lock-in voltmeter. The analysis of the operation of the entire measuring system was modelled in Matlab/Simulink, and the operation results were presented.
5
EN
The paper purposed to design a LabVIEW application for measuring the S-parameters and impedance for high-frequency electronic devices such as RFID tag or antenna which cannot be connected to a connector by using a differential probe. A differential probe was fabricated from RG 402 semi-rigid coaxial cable for connecting to the impedance test point and to the vector network analyzer for S-parameter measurements. The LabVIEW Application was developed for data collection of S-parameter from the vector network analyzer and then the data used to calculate and determine the impedance of the device.
PL
Artykuł miał na celu zaprojektowanie aplikacji LabVIEW do pomiaru parametrów S i impedancji dla urządzeń elektronicznych o wysokiej częstotliwości, takich jak znacznik RFID lub antena, których nie można podłączyć do złącza za pomocą sondy różnicowej. Sonda różnicowa została wykonana z półsztywnego kabla koncentrycznego RG 402 do podłączenia do punktu pomiaru impedancji oraz do wektorowego analizatora sieci do pomiarów parametrów S. Aplikacja LabVIEW została stworzona do zbierania danych parametru S z wektorowego analizatora sieci, a następnie danych służących do obliczenia i określenia impedancji urządzenia.
EN
In this paper, the impedance and mobility compact matrix (IMCM) method for prediction of acoustic modal characteristics of two dimensional irregular cavities with the rigid wall boundary is presented. This method consists of discretizing the whole cavity into a series of subcavities either of regular or irregular shape. Continuity of both pressure and veloc- ity between adjacent subcavities is ensured using a virtual membrane with zero mass and stiffness. Mathematical formulation for acoustic cavities with the irregular shape has been explained in detail. A finite element model has been developed to calculate the acoustic natural frequency and mode shape. The proposed method is validated using a regular and irregular cavity and compared with finite element modelling results and available results in the literature.
EN
The paper deals with a theoretical study on blood flow in a stenosed segment of an artery, when blood is mixed with nano-particles. Blood is treated here as a couple stress fluid. Stenosis is known to impede blood flow and to be the cause of different cardiac diseases. Since the arterial wall is weakened due to arterial stenosis, it may lead to dilatation /aneurysm. The homotopy perturbation technique is employed to determine the solution to the problem for the case of mild stenosis. Analytical expressions for velocity, shear stress at the wall, pressure drop, and flow resistance are derived. The impact of different physical constants on the wall shear stress and impedance of the fluid is examined by numerical simulation. Streamline patterns of the nanofluid are investigated for different situations.
PL
W artykule przedstawiono stanowisko pomiarowe do badania spektroskopii impedancyjnej bazujące na kartach USB-6003 i Personal DAQ/3000. W środowisku LabVIEW 2013 opracowano wirtualny spektroskop składający się z generatora fali sinusoidalnej oraz dwukanałowego rejestratora sygnałów na wejściach różnicowych karty pomiarowej. Opracowana aplikacja zapisuje zarejestrowane wartości do pliku, a następnie odpowiedni algorytm wylicza impedancję obiektu oraz jej składowe. W pracy przedstawiono przykładowe wyniki analiz oraz ich niepewności.
EN
The paper presents a test stand for impedance spectroscopy based on a USB-6003 and Personal DAQ/3000 card. A virtual spectroscope consisting of a sinus generator and a two-channel recorder has been developed in LabVIEW 2013 environment. This application saves the recorded values to the file and the algorithm calculates the impedance of the object and its components. Results of analyses and their uncertainties are also presented.
PL
Badania ultrasonograficzne z wykorzystaniem zjawiska propagacji fali ścinającej w ośrodkach o różnej impedancji akustycznej – oporności tkanek w czasie przechodzenia przez nie fali mechanicznej – ultradźwiękowej, są w stanie wykazać metodami obrazowymi obecność zmian, które mogą być stwierdzone jedynie w badaniach histopatologicznych. Autor przedstawia podstawy fizyczne, mechanizmy obrazowania oraz podstawowe zastosowania metody.
EN
Ultrasound examinations, using the shear wave propagation phenomenon in medium with different acoustic impedance – tissue resistance during the passing of a mechanical wave – ultrasound wave, are able to show, by means of imaging methods, the presence of changes that can be found only in histopathological studies. The author presents physical fundamentals, imaging mechanisms and basic applications of the modern ultrasound examination method.
EN
This paper is devoted to a detailed experimentally based analysis of applicability of vector network analyzers for measuring impedance of surface mount inductors with and without DC bias. The measurements are made using custom-made bias tees and a test fixture with an ordinary vector network analyzer. The main attention in the analysis is focused on measurement accuracy of an impedance of surface mount inductors. Measurement results obtained with a vector network analyzer will also be compared to those obtained by using an impedance analyzer based on auto-balancing bridge method.
PL
W artykule przedstawiono impedancję osi pojazdu szynowego jako jeden z elementów badanych w procesie homologacji pojazdów szynowych. Pokazano także wartości dopuszczalne impedancji osi przyjmowane na polskiej sieci kolejowej oraz metody ich pomiarów. Zaprezentowano również wybrane wyniki pomiarów rezystancji i impedancji pojazdów szynowych.
EN
The article presents impedances of the rail vehicle axle as one of the elements tested in the approval process of railway vehicles. Therefore, shunt impedance limits of track circuits used on the polish rail network infrastructure and methods of testing rolling stock axle resistance and impedance were discussed. Axles resistance and impedance measurement results of selected rolling stock were presented.
PL
Wykorzystanie wyników sejsmicznych badań offsetowych do interpretacji złożowej jest powszechnie stosowane w poszukiwaniach złóż węglowodorów. Podstawowa interpretacja ilościowa parametrów związanych z właściwościami złożowymi oparta jest na analizach zmian amplitudy z offsetem (AVO). W tym wypadku analizowana jest amplituda sygnału odbitego od stropu złoża. Efekty anomalne obserwowane w offsetowej analizie amplitud (zmiana amplitudy z offsetem) wywołane obecnością węglowodorów powodowane są anomalną wartością współczynnika Poissona w warstwie złożowej (obecność np. gazu istotnie zaniża wartość współczynnika Poissona). Dysponując zapisem offsetowym (tzw. składowymi) można z zapisu sejsmicznego pozyskać znacznie bogatszą informację niż tylko sam efekt anomalny widoczny na przekrojach sejsmicznych. Dodatkowymi atrybutami zapisu sejsmicznego korelowanymi z właściwościami warstwy złożowej a obliczanymi na podstawie zmienności amplitud z offsetem są impedancja fali P, impedancja fali S, wskaźnik fluid factor, parametry geomechaniczne λ⋅ρ, μ⋅ρ oraz współczynnik Poissona. W prezentowanym artykule autorzy przedstawiają wyniki pierwszej próby zastosowania szacowania parametrów geomechanicznych w aspekcie oceny właściwości złoża siarki. Do oceny tych parametrów niezbędne są informacje o parametrach petrofizycznych pozyskanych z badań geofizyki otworowej. W tym przypadku autorzy dysponowali danymi dotyczącymi porowatości, gęstości, zawartości siarki, oraz prędkości fali podłużnej P z dwóch otworów. Pomiar wartości prędkości fali poprzecznej S w warunkach produkcyjnych jest niezmiernie utrudniony i autorzy wykorzystali tu zależności opracowane na podstawie wcześniejszych badań opisanych w monografii autorstwa Jerzego Deca pt. Wysokorozdzielcze badania sejsmiczne w celu rozpoznania złoża siarki Osiek oraz określania zmian dynamicznych zachodzących w wyniku eksploatacji. Wieloletnie badania geofizyczne wskazują, że wraz ze spadkiem porowatości obserwuje się wzrost zawartości siarki. Jednocześnie w przypadku podwyższonych koncentracji siarki szkielet wapienny złoża jest bardziej sztywny, a złoże określane jest jako zbite. Dla takich warunków petrofizycznych złoże siarki wykazywać będzie wysokie wartości impedancji fali P i S, co skutkować będzie również wzrostem właściwości geomechanicznych λ⋅ρ i μ⋅ρ. Uzyskane wyniki zaprezentowane są na przykładzie profilu sejsmicznego wykonanego w kopalni siarki w Osieku. Profil ten przebiegał w linii otworów, w których określono podstawowe parametry złoża na podstawie geofizycznych badań otworowych.
EN
The usage of seismic offset data for reservoir characterization is widely used for hydrocarbon exploration. The basic quantitative interpretation of the parameters related to reservoir properties is based on the amplitude versus offset analysis (AVO). The AVO analysis utilizes the signal’s amplitude reflected from the top of the reservoir. Anomalies observed in the offset domain are caused by anomalous changes in Poisson’s ratio values (e.g. hydrocarbon saturation in rock results in lowering Poisson’s ratio). When seismic offset data is available (pre stack CMP gathers) one can obtain more information than just the anomalous effect seen on stacked seismic sections alone. Additional attributes which correlated with the properties of the reservoir rock can be extracted from amplitude changes with offset are P-wave impedance, S-wave impedance, Fluid Factor, geomechanical parameters λ⋅ρ, μ⋅ρ and Poisson’s ratio. In this article, the authors present the results of the first attempt to apply the estimation of geomechanical parameters in the aspect of sulphur deposit properties evaluation. The well log data is necessary for the evaluation of these parameters. In this case, the authors had the measurements of porosity, bulk density, sulphur content and P-wave velocity from two wellbores. Shear wave measurement in the productive area is extremely difficult. Therefore, the authors used relationships developed on the basis of earlier studies described by Jerzy Dec in the monograph entitled: „High-Resolution Seismic Survey for the Recognition of the Osiek Sulphur Deposits and the Determination of Dynamic Changes Resulting from Exploitation”. Long-term geophysical measurements indicate that an increase in sulphur content is accompanied by a decrease in porosity. At the same time, in the case of high sulphur concentrations, the limestone framework is more rigid and the deposit is defined as solid. The sulphur deposit will exhibit high values of P-wave impedance and S-wave impedance for such petrophysical conditions, which will also result in the high values of geomechanical parameters such as λ⋅ρ and μ⋅ρ. The obtained results are demonstrated by the example of the seismic profile recorded in the area of the Osiek Sulphur Mine. The analyzed profile went along the line of wellbores in which the basic reservoir parameters was measured.
PL
Przesuwniki fazowe stanowią nowy rodzaj obiektu w Krajowym Systemie Elektroenergetycznym. Ich obecność w strukturze układu sieciowego może prowadzić do znacznych zmian warunków działania elektroenergetycznej automatyki zabezpieczeniowej. W artykule przedstawiono wyniki analizy zmiany wybranych warunków pracy zabezpieczeń odległościowych linii wokół miejsca przyłączenia przesuwników fazowych. Jako studium przypadku przyjęto fragment sieci z przesuwnikami fazowymi w stacji Mikułowa.
EN
Phase shifters transformers (PST) are new kind of object in the Polish Power System. Operating conditions of power system protection can make a significant change after installation PST. In paper presents results of analysis operating conditions of line distance protections in power system with PST. As a case study taken a power system neighboring Mikułowa power station with PST.
14
PL
Artykuł prezentuje metodę obliczania oporu relacji skrętnych na skrzyżowaniach dla makroskopowych miejskich modeli ruchu. Pokazano, jak na podstawie dostępnej bazy danych o warszawskiej sieci drogowej można zbudować model sieciowy wraz z określeniem przepustowości i czasów traconych na relacjach skrętnych. Wykorzystano w nim podstawowe formuły inżynierii ruchu (Gaca i in., 2008) pozwalające obliczyć przepustowość (poprzez oszacowanie natężenia nasycenia, udziału efektywnego sygnału zielonego, potoku nadrzędnego) oraz czasy przejazdu (swobodny oraz tracony) dla skrzyżowań sygnalizowanych, niesygnalizowanych i rond. Proponowana metoda jest uogólnieniem dostosowanym do dostępnej bazy danych i potrzeb makroskopowego modelu ruchu dużego obszaru (np. Aglomeracja Warszawska). Nie uwzględnia wszystkich czynników wpływających na przepustowość, jednak pozwala zbudować model sieciowy, w którym, tak jak w rzeczywistości, o czasie przejazdu i powstawaniu kolejek decyduje ograniczona przepustowość skrzyżowań, a nie odcinków. Metoda może być zastosowana w budowie modelu sieciowego dla dużego miasta przy użyciu dostępnej bazy danych bez znacznego zwiększenia czasów obliczeń. Wyniki metody ilustrują przykłady dla wybranych skrzyżowań w Warszawie.
EN
In the article we propose method to model a junction impedance in the static macroscopic traffic network graphs. The available network database is used to parameterize the Warsaw road’ network. We use the generic data for the urban network: link types, node types, turn types and traffic signs. Thanks to this we are able to apply fundamental Intersection Capacity Analysis formulas (Gaca, et al. 2008) and compute the capacities and travel times for the turns in the network of Warsaw. The methods are proposed both for signalized, uncontrolled intersections and roundabouts. We propose heuristics for effective green, saturation flow, main flow and number of lanes, which can be practically applied in the urban macroscopic models. We apply and parameterize the Akcelik (1981) delay formulas to calculate the total travel time in the congested network. The paper is illustrated with both signalized and uncontrolled junctions in Warsaw. The results are plausible and the model can be further tested in practical applications.
PL
Dokonano analizy impedancji sieci prądu stałego w instalacji fotowoltaicznej. Analizę tę przeprowadzono pod względem predykcji charakterystyki zaburzeń elektromagnetycznych generowanych przez instalacje PV. Badania przeprowadzono zarówno dla zaburzeń różnicowych, jak i wspólnych. Zastosowano podejście analityczne - wykorzystując teorię linii długiej oraz pomiary wykonane na stanowisku laboratoryjnym.
EN
This paper presents the impedance analysis of the DC network in photovoltaic installation. Presented analysis was performed due to electromagnetic interferences generated in those installations. Tests was carried out for differential and common mode interferences. An analytical approach - using long line theory was used with the laboratory setup measurements.
EN
The results of investigations of the metrological properties of the system of 4 biomedical electrodes with the continuous control of the contact quality, are presented in the hereby paper. Investigations were performed under real conditions of measuring the electrocardiographic signals of humans, at the application of the typical ECG instrumentation. Due to the performed experiments the conformity of the electrocardiographic signals obtained by means of the standard gel electrodes glued to the body and the ones obtained by means of the electrodes with continuous control of the contact quality, was confirmed.
PL
W artykule przedstawiono wyniki badań właściwości metrologicznych układu 4 elektrod do pomiaru sygnałów elektrokardiograficznych człowieka z ciągłą kontrolą stanu kontaktu, przy wykorzystaniu typowej aparatury EKG. Potwierdzono zgodność zapisów sygnałów EKG wykonanych za pomocą standardowych elektrod żelowych przyklejanych do ciała oraz przy zastosowaniu elektrod z ciągłą kontrolą stanu kontaktu.
PL
W części 1 rozpatrzono cztery schematy zastępcze jako modele impedancji rezystora przy prądzie przemiennym, tj. schematy z parametrem głównym R i parametrami pasożytniczymi L i C. Wyznaczono podstawowe ich parametry w funkcji względnej częstotliwości i rezystancji oraz dokonano ich analizy. Część 2 tego artykułu poświęcona jest analizie możliwości korekcji częstotliwościowej rezystora. Wykazano, że rezystory o rezystancji R mniejszej od ich wartości charakterystycznej R0 (zwykle rzędu kilkudziesięciu do kilkuset omów) można korygować częstotliwościowo przez bocznikowanie kondensatorem, a rezystory o rezystancji większej od R0 – przez dołączanie szeregowo cewki indukcyjnej. Oceniono realne możliwości i skuteczność takiej korekcji, użyteczny zakres częstotliwości skorygowanego rezystora oraz wpływ niedokładności elementu korygującego (cewki lub kondensatora) na jakość korekcji. Podano przykłady obliczeniowe.
EN
In the part 1 the basic model of the resistor for the AC current as the equivalent circuit with two RL and C parallel branches was chosen and considered in detail. The characteristic parameters of its impedance changes in relative terms are introduced and its properties as a function of relative frequency and relative resistance are analyzed. The formulas of relative frequency errors, i.e. changes of resistance and reactance components of the impedance of few other AC equivalent circuits of resistor have been determined and analyzed. The considerations are illustrated by the numerical example and conclusions were drawn. Correction of the resistor frequency characteristics are discussed in this Part 2 of work.
PL
W części 1 rozpatrzono cztery modele (schematy zastępcze) impedancji rezystora przy prądzie przemiennym zawierające parametr główny rezystancję R i parametry resztkowe:szeregową indukcyjność L i bocznikującą pojemność C. Przy prądzie przemiennym część rzeczywista impedancji rezystora nie jest równa jego rezystancji R przy prądzie stałym i pojawia się różna od zera część urojona. Wyznaczono wzory błędów częstotliwościowych rezystorów w formie uogólnionej, tj. w funkcji względnych wielkości rezystancji i częstotliwości. Wyniki obliczeń tych błędów przedstawiono w postaci wykresów. Rozważania zilustrowano przykładami liczbowymi i sformułowano wnioski. Część 2 pracy poświęcona będzie omówieniu możliwości korekcji charakterystyki częstotliwościowej rezystorów.
EN
In the part 1 four models of resistors for the AC current are considered. As the most useful model the equivalent circuit with two parallel branches R L and C is chosen. The characteristic parameters of its impedance in relative terms are introduced and its properties as a function of relative frequency are analyzed. The formulas of relative frequency errors, i.e. changes of resistance and reactance components of the impedance of few AC equivalent circuits of resistor have been determined in relative parameters and analyzed. The considerations are illustrated by the numerical example and conclusions were drawn. Corrections of the resistor frequency characteristic will be discussed in the Part 2 of this work.
EN
Three-element impedance including the resistance R as the main parameter and the residual parameters: serial inductance L and a parallel capacitance C is used as an equivalent circuit of resistor. It is the basic model of resistor for AC current. The real component of this impedance is not equal to the resistance R for the DC current, and there is the imaginary component. Both components depend on the frequency. Variants of the model with four different connections are also analyzed. Patterns of the relative resistor frequency errors in the generalized form, i.e. as a function of the relative values of resistance and frequency of the circuit are determined and their curves are given. Considerations are illustrated by few numerical examples
EN
Layered oxide LiMO2 (Ni, Co, Mn) have been proposed as cathode materials for lithium-ion batteries. Mainly LiNiO2 is accepted as an attractive cathode material because of its various advantages such as low cost, high discharge capacity, good reversibility. The LiNi0.5 Mn0.5 O2 powders are synthesized by a sol-gel method using citric acid as a chelating agent. The structure of the synthesized material is analyzed by using XRD, FT-IR and the microstructures of the samples are observed by using FESEM. The intensities and positions of the peaks are in a good agreement with the previous results. The morphological changes are clearly observed as a result of manganese substitution. The Fourier transform infrared (FT-IR) spectra obtained with KBr pellet data reveal the structure of the oxide lattice constituted by LiO6 and NiO6 octahedra. The conductivity studies are characterized by (EIS) in the frequency range of 42 Hz to 1 MHz at room temperature to 120 °C. The dielectric properties are analyzed in the framework of complex dielectric permittivity and complex electric modulus formalisms. It indicates that the conductivity increases with increasing temperature. The fitting data of EIS plots replicate the non-Debye relaxation process with negative temperature coefficient of resistance (NTCR) behavior.
first rewind previous Strona / 5 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.