Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 66

Liczba wyników na stronie
first rewind previous Strona / 4 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  high voltage
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 4 next fast forward last
EN
In this research paper, the problem of studying the effectiveness of ozone in the process of water treatment was considered. In the course of the scientific work, a review of domestic and foreign literature was conducted; its advantages and disadvantages were considered. The research paper presented the theoretical and practical methods of water purification with ozone. The main factors influencing the efficiency of the technology in the process of water purification were also considered. It was established that as a technological method of water purification, the efficiency of the ozonation process includes not only the cost of electricity, but also the efficiency of its mixing, ozone dissolution in treated water. In addition, special attention is paid to the final stage of mixing the ozone-air mixture with treated water. From the results obtained, it can be seen that after primary ozonation, the concentrations of chromium, oxidation of permanganate, iron, petroleum products, metal ions and other pollutants significantly decreased. During further water purification, organic and inorganic pollutants are removed in the future (completely or up to the requirements of the standard). However, calcium, magnesium, sulfates, chlorides, pH value, alkalinity and hardness practically do not change. The water quality after primary ozonation according to bacteriological indicators met the requirements of the standard.
EN
In scientific research, precise control of high voltages is crucial, particularly in ion traps and Gas Electron Multiplier (GEM) de tectors. The Sinara open hardware project addresses this need by developing a dedicated high-voltage system. The project introduces an STM32-based DIOT system board and a High Voltage Supply Board (HVSUP_ISOL) designed for non-real-time applications, providing up to +/-6kV. The HVSUP_ISOL board is fully isolated, ensuring system safety, and offers dual-channel configuration with a shared common terminal for easy casca ding. The firmware based on the MQTT protocol enables users to remotely control various settings, and telemetry data provi des insights into the system’s operation.
PL
W badaniach naukowych precyzyjna kontrola wysokich napięć jest niezwykle istotna, zwłaszcza w pułapkach jonowych i de tektorach GEM (Gas Electron Multiplier). W ramach projektu Sinara, zaprojektowany został nowy dedykowany system ge neracji i kontroli wysokich napięć. Projekt wprowadza kartę systemową DIOT opartą na układzie STM32 oraz kartę zasi lania wysokonapięciowego (HVSUP_ISOL), przeznaczoną do zastosowań nie wymagających kontroli w czasie rzeczywistym, dostarczającą napięcia do +/-6kV. Karta HVSUP_ISOL jest w pełni izolowana, zapewniając bezpieczeństwo systemu, oraz oferuje konfigurację dwukanałową z wspólnym terminalem dla łatwego kaskadowania. Oprogramowanie oparte na protokole MQTT umożliwia użytkownikom zdalną kontrolę różnych ustawień, a dane telemetrii dostarczają informacji o działaniu systemu.
PL
Rezystory wysokonapięciowe to elementy, które wymagają specjalnych wymogów konstrukcyjnych, zwłaszcza w zakresie odporności napięciowej oraz charakteryzują się dużą mocą obciążenia. Poszukiwanie nowych rozwiązań konstrukcyjnych oraz materiałowych powoduje rozwój badań w tym zakresie, które są intensywnie wspomagane przez producentów elektronicznych wysokonapięciowych elementów pasywnych.
EN
High-voltage resistors are elements that require special design requirements, especially in terms of voltage resistance and are characterized by high load power. The search for new design and material solutions results in the development of research in this area, which is intensively supported by manufacturers of electronic high-voltage passive components.
PL
Artykuł zawiera charakterystykę badań wyładowań niezupełnych wprowadzanych w kolejnych etapach produkcji kabli elektroenergetycznych o izolacji z papieru nasyconego i polietylenu, na wszystkich poziomach napięć znamionowych tj. średnich, wysokich i najwyższych. Zwrócono uwagę na prace CIGRE w tej dziedzinie i działalność Konferencji Wielkich Sieci Elektrycznych, których efektem był pierwszy projekt programu badań poprodukcyjnych kabli wysokiego napięcia opisany w Przeglądzie Elektrotechnicznym nr 1 w 1931 roku. W dalszej części niniejszego artykułu opisano metody pomiaru wyładowań niezupełnych realizowane w systemach pomiarowych zapewniających przetwarzanie przebiegów impulsowych wyładowań do postaci obrazów fazowych. Przedstawiono również wyniki badań laboratoryjnych oddziaływania wyładowań niezupełnych na materiały izolacyjne, w tym identyfikacje procesów erozyjnych w źródłach wyładowań i skutki migracji ładunków elektrycznych na powierzchniach granicznych w układach izolacyjnych.
EN
The article contains the characteristics of the partial discharge tests introduced in the subsequent stages of the production of power cables with insulation made of impregnated paper and polyethylene, at all voltage levels, i.e. medium, high and ultra-high voltage. Attention was paid to the work of CIGRE in this field and the activity of the Conference of Large Electric Systems, the effect of which was the first draft program for postproduction testing of high-voltage cables, described in the article in the Przegląd Elektrotechniczny No. 1 in 1931. The methods of partial discharges measurement implemented in diagnostics systems ensuring the processing of discharge pulse waveforms to the form of phase-resolved images are described. The article also presents the results of laboratory tests of the effect of partial discharges on insulating materials, including the identification of erosion processes in discharge sources and the effects of electric charge migration on the boundary surfaces of insulating systems.
5
Content available remote Arc plasma energy evolvement in 60 kV network circuit breakers
EN
The evolvement of the electric and energetic properties of electric arcs at the poles opening of a circuit breaker (CB) is described by non-linear mathematical models. Most of these models are dimensional types that do not describe the interaction between the arc and the network during the interruption phase. This paper is aimed at the determination of the energy necessary for the arc creation at the opening of a high-voltage circuit breaker with a black box model. The advantage of this model consists of its ability to link the intrinsic characteristics of the arc to the extern blowing (quenching) power. Moreover, it provides fast and stable solving without needing for spatial dimensions of the breaker. The model is applied to a line circuit breaker for which experimental results are available in the literature. Two phases of arc quenching evolvement are evidenced: Constant energy phase followed by a decreasing energy one. The Kema-based model is found to be more accurate for online plasma quenching analysis and the obtained results agree well with experimental ones where the heat energy represents the dominating part.
PL
Ewolucję właściwości elektrycznych i energetycznych łuków elektrycznych przy otwarciu biegunów wyłącznika opisują nieliniowe modele matematyczne. Większość z tych modeli to modele wymiarowe, które nie opisują interakcji między łukiem a siecią podczas fazy przerwania. Celem artykułu jest określenie energii niezbędnej do wytworzenia łuku przy otwarciu wyłącznika wysokonapięciowego z modelem czarnej skrzynki. Zaletą tego modelu jest możliwość powiązania wewnętrznych charakterystyk łuku z zewnętrzną mocą nadmuchu (gaszenia). Ponadto zapewnia szybkie i stabilne rozwiązywanie bez konieczności wymiarowania przestrzennego wyłącznika. Model stosuje się do wyłącznika liniowego, którego wyniki eksperymentalne są dostępne w literaturze. Wykazano dwie fazy rozwoju gaszenia łuku: faza stałej energii, po której następuje faza malejącej energii. Stwierdzono, że model oparty na Kema jest dokładniejszy do analizy hartowania plazmowego w trybie online, a uzyskane wyniki dobrze zgadzają się z wynikami eksperymentalnymi, w których dominującą część stanowi energia cieplna.
6
PL
W artykule przedstawiono wyniki eksperymentalnych badań podstawowych, w ramach których dokonano analizy zmienności w czasie sygnałów elektrycznych generowanych przez wyładowania niezupełne (WNZ) przy uwzględnieniu wpływu rodzaju materiału dielektrycznego. Celem badań jest pogłębienie wiedzy o samym zjawisku WNZ i wskazanie nowych nie dostatecznie poznanych do tej pory jego aspektów. Przedstawione wyniki potwierdziły, że każdy z przebadanych materiałów dielektrycznych emituje indywidulane sygnały elektryczne, które w różnym stopniu zmieniają się w czasie.
EN
The article presents the results of experimental basic research, which analyzed the variability in time of electrical signals generated by partial discharges (PD), taking into account the influence of the type of dielectric material. The aim of the research is to deepen the knowledge about the PD phenomenon itself and to identify new, not yet sufficiently known, aspects of it. The presented results confirmed that each of the tested dielectric materials emits individual electrical signals that vary to a different extent over time.
EN
The development of a mathematical model of a three-phase ultrahigh voltage transmission line with two overhead ground wires is presented in the paper. The mathematical model is based on differential equations of state of a long line with partial derivatives in the matrix-vector form. The boundary conditions of the second kind (Neumann's conditions) are used, which enables obtaining functions of unknown coordinates of the overhead ground wires mode at the beginning and at the end of the voltage transmission line to solve the transmission line equation. Some results of computer simulations of transients during switching on and a single-phase short circuit of the line are presented in the form of corresponding graphic functions of its mode coordinates.
PL
W artykule przedstawiono model matematyczny trójfazowej linii elektroenergetycznej ultra wysokiego napięcia z dwoma przewodami odgromowymi. Model matematyczny wykorzystuje równania różniczkowe o pochodnych cząstkowych elektromagnetycznej długiej linii w postaci macierzowo-wektorowej. Jako warunki brzegowe wykorzystano warunki drugiego rodzaju (warunki Neumanna), co z kolei pozwoliło obliczyć przebiegi napięcia i prądu na początku i na końcu linii elektroenergetycznej. Wyniki symulacji komputerowej stanów nieustalonych podczas załączania linii oraz zwarcia jednofazowego w jej końcu przedstawiono w postaci rysunków.
EN
Capacitive leakage and adjacent interference are the main influence sources of the measuring error in the traditional series step-up method. To solve the two problems, a new algorithm was proposed in this study based on a three-ports network. Considering the two influences, it has been proved that response of this three-ports network still has characteristics of linear superposition with this new algorithm. In this threeport network, the auxiliary series voltage transformers use a two-stage structure that can further decrease measurement uncertainty. The measurement uncertainty of this proposed method at 500/√3 kV is 6.8 ppm for ratio error and 7 μrad for phase displacement ( k = 2). This new method has also been verified by comparing its results with measurement results of the PTB in Germany over the same 110/√3 kV standard voltage transformer. According to test results, the error between the two methods was less than 2.7 ppm for ratio error and 2.9 μrad for phase displacement.
EN
The aim of this paper is to compare three different methods of analysis of results of lightning impulse breakdown voltage measurements of solid materials such as insulating pressboard. These three methods are the series method, the step method and the up-and-down method which are applied to withstand voltage estimation commonly in high voltage engineering. To obtain the data needed for the analysis a series of experimental studies was carried out. It included studies of mineral oil and natural ester impregnating 1 mm of thick cellulose-based pressboard. In order to show the distribution of breakdown voltage the Weibull distribution was additionally applied in data analysis. The results were also assessed from the viewpoint of dielectric liquid used for impregnation. The studies carried out showed that series and step methods give comparable results opposite to the up-and-down method. The latest overstates the results for mineral oil impregnated pressboard and understates for natural ester impregnated pressboard when juxtaposing them with the rest of the methods applied. In addition, there is lack of possibility to assess the withstand voltage for the up-and-down method directly from the vector of random variable. It is possible only as a result of a specially developed equation which always arouses doubt. From the methods applied it seems that the step method can be a great substitution for the series method as intuitive, fast in application and limiting the number of samples in solid insulation material testing.
EN
A principle diagram of a high-voltage low-power power supply for devices comprising a microchannel plate (MCP) has been developed. A mathematical model was built according to the developed scheme for a detailed study of the operation of the power supply and the selection of the optimal parameters of its components and obtaining the best output voltages. The power supply circuit comprises a control circuit, a pulse transformer, a voltage multiplier circuit, a feedback circuit, and an input stabilizer. The input stabilizer provides the maintenance of the voltage switched in the primary winding of the transformer at a given level regardless of the voltage drop of the power supply primary source. Moreover the stabilizer provides constant voltage maintenance when the load resistance changes. (with Rload changing from 100 to 200 MΩ, Uout did not exceed 3 V).
11
Content available remote Nine-phase transmission line design: implementation using Matlab/Simulink
EN
This paper presents the design and the study of a nine-phase transmission line system. Two lines (400 kV over 200 km and 400 kV over 600 km) are implemented using Matlab/Simulink to solve problems of environmental damage caused by several lines located in the same place, the multiplicity of electric faults and the poor power capability transmitted of the three-phase systems. The results obtained show that nine-phase line system could connect up to 9.6 times more load than that of a three-phase line system.
PL
W artykule zaprezentowano projekt i analizę dziewięciofazowej linii przesyłowej. Analizowano dwie linie 400 kV – 200 km i 400 kV 600 km. Stosując Matlab/Simulink analizowano zakłócenie środowiska, możliwości powstawania błędów i możliwości przesyłania mocy. Wykazano że sieć dziewięciofazowa pozwala na obciążalność 9.6 razy większą niż sieć trójfazowa.
EN
In this paper, results of investigation on the impact of firing temperature on insulating properties of Low Temperature Cofired Ceramics are presented. Dissipation factor, volume resistivity and breakdown electric field intensity were determined for firing peak temperature in the range from 800 °C to 900 °C. The tests were performed for two commercial LTCC materials: 951 Green Tape (DuPont, USA) and SK47 (Keko, Slovenia). The results showed that the firing temperature had a significant effect on the dielectric loss factor, volume resistivity and lifetime at applied high voltage. No clear tendency was observed for dielectric strength in the analyzed firing temperature range.
PL
Według autorów, w przodujących ośrodkach naukowo-badawczych zajmujących się diagnostyką stanu izolacji uzwojeń maszyn elektrycznych zauważyć można cztery kierunkowe obszary prac badawczych: prace nad opracowywaniem nowych konstrukcji czujników do pomiarów wnz; prace nad opracowaniem uniwersalnego analizatora wnz z ulepszonymi osiągami w zakresie tłumienia szumów i zakłóceń; prace nad opracowaniem urządzeń przenośnych, mobilnych; prace nad opracowaniem coraz to bardziej złożonych analizatorów, umożliwiających pomiary i analizę sygnałów wnz w bardzo szerokim zakresie czasu i częstotliwości; analizatory te umożliwiają wyznaczenie np. funkcji korelacji.
EN
Operation of electric machines is accompanied by partial discharges. Partial discharges have a very complex nature. Together with progressing use of machines, there is a change in the intensity of partial dis­charges with typical phase-resolved distributions. The diagnostics can be carried out using available partial charge detectors. The author’s solutions regarding detectors and devices for measurements of partial dis­charges in electric machines in industrial conditions have proved to be successful. Results of measurements of partial discharges in motors depend on: the condition of their insulation, motor load, temperature of windings, humidity, level of external interference, and characteristics of partial discharge detectors and partial discharge analysing devices.
EN
The flashover of pollution, observed on the insulators used in high voltage transmission, is one of the most important power transmission stakes. It is a very complex problem due to several factors including the modelling difficulties of complex shapes of insulators, different pollution densities at different regions, non-homogeneous pollution distribution on the insulator surface and unknown effect of humidity on the pollution. In the literature, some static and dynamic models have been developed by making some assumptions and omissions to predict the flashover voltages of polluted insulators. This paper aims to experimentally analyse the flashover process and simulation of the distributions of the potential and the electric field under 50 Hz applied voltage on a real model simulating the 175CTV outdoor insulators largely used by the Algerian Company of Electricity and Gas (SONELGAZ). This real model is studied under non-polluted (distilled water), and polluted (distilled water and sand) environments. The simulations were carried out by using the COMSOL multiphysics software. This program uses the finite element method to solve the partial differential equations that describe the field. Experimental results made in the laboratory and simulation results are original and found to be congruent.
PL
Artykuł poświęcony jest obliczeniom impulsowych prądów wysokiej częstotliwości, przepływających przez uziemienia urządzeń wysokiego napięcia podczas przełączeń oraz zwarć. Znajomość wartości tych prądów jest niezbędna do oceny kompatybilności elektromagnetycznej w elektrowniach i podstacjach, pod kątem zakłóceń podczas przełączania i zwarć. W artykule przeanalizowano obowiązujące standardy, wyniki pomiarów oraz obliczeń prądów impulsowych wysokiej częstotliwości w urządzeniach o napięciu znamionowym od 6 kV do 35 kV, które to nie są ujęte w w/w standardach. Zależności prądów impulsowych wysokiej częstotliwości, rozchodzących się przez uziemienia podczas przełączania i zwarć w urządzeniach wysokiego napięcia, określa się w zależności od specyficznej rezystancji elektrycznej ziemi i konstrukcji tych urządzeń. W artykule podano zalecenia dotyczące włączenia prądów impulsowych wysokiej częstotliwości do standardu „Wytyczne dotyczące projektowania urządzeń uziemiających sieci 10-20 kV z rezystancyjnie uziemionym punktem neutralnym” organizacji „Zjednoczona spółka energetyczna” S.A. (Moskwa).
RU
V stat’е rassmotreny voprosy ocenki vеličiny vysokočаstnogo impul’snogo toka, rastekaûŝеgоsâ po zazemlâûŝеmu ustrojstvu pri komputaciâh i korotkih zamykaniâh оborudovaniâ vysokogo naprâženiâ. Ukazannaâ vеličina neobhodima dlâ оcеnki êlektromagnitnoj obstanovki na podstanciâh i êlektrostanciâh v čаsti vypolneniâ rasčёtov konduktivnyh pomeh pri komputaciâh i korotkih zamykaniâh oborudovaniâ vysokogo napraрâžеniâ. V stat’е privedёn analiz normativnoj dokumentacii, rezul’taty izmerenij i rasčёtov vеličiny vysokočаstnogo impul’snogo toka v êlektroustanovkah 6-35 kV, otsutstvuûŝеj v normativnoj dokumentacii. Оpredeleny zavisimosti vеličiny vysokostatnogo impul’snogo toka, rastekaûŝеgosâ pо zazemlâûŝеmu ustrojstvu pri komputaciâh i korotkih zamykaniâh oborudovaniâ vysokogo napraženiâ, ot veličiny udel’nogo êlektričеskogo soprotivleniâ grunta i konstruktivnogo ispolneniâ raspredelitel’nyh ustrojstv. Privedeny rekomendacji po vklûčеniû vеličiny vysokočаstnogo impul’snogo toka v standart organizacii «Меtodičеskiе ukazaniâ pо proektirovaniû zazemlâûŝih ustrojstv setej 10-20 kV s rezistivno zazemlёnnoj nejtral’û» АО «Оbʺеdinёnnaâ ênergetičеskajâ kompaniâ» (г. Moskva).
EN
This paper presents a study on ferroresonance occurring in a high voltage 400 kV transmission grid due to energization of power transformer under no-load conditions. The system scenarios analyzed in the present paper are considered as critical for development and modernization plans as currently announced by the national grid operator in Poland. The PSCAD simulation model was developed and applied for several study cases of a system with double-circuit arrangement of a transmission line. It is shown that the ferroresonant oscillations can be initiated by two-phase switching operation of a line circuit breaker. The impact of the double-circuit length on the ferroresonance mode and severity is demonstrated with the use of the Poincaré map analysis and Short Time Fourier Transform. It is demonstrated that the length of the transmission line that is mutually coupled in the double-circuit arrangement has a significant impact on the ferroresonance occurrence and on its mode. As the ferroresonance can pose severe threat to the power system components due to the severe overvoltage and overcurrent oscillations, the analysis presented in this paper demonstrates the necessity of the ferroresonance analyses for any re-designed transmission system.
17
Content available remote Current state of photoconductive semiconductor switch engineering
EN
This paper presents the current state of a photoconductive semiconductor switch engineering. A photoconductive semiconductor switch is an electric switch with its principle of operation based on the phenomenon of photoconductivity. The wide application range, in both low and high-power devices or instruments, makes it necessary to take design requirements into account. This paper presents selected problems in the scope of designing photoconductive switches, taking into account, i.e. issues associated with the element trigger speed, uniform distribution of current density, thermal resistance, operational lifespan, and a high, local electric field generated at the location of electrodes. A review of semiconductor materials used to construct devices of this type was also presented.
EN
The knowledge of the distribution of the electric field within and around high voltage equipment is a crucial aspect of the design, exploitation and performance of high voltage insulators. It could be useful for the detection of defects in insulators. The objective of this study is predicting the behavior of polluted insulator under AC voltage. For thus, the distribution of the potential and the electric field along high voltage insulator is investigated using a numerical method. The commercial Comsol Multiphysics proved to be one of the best software used in 2D modeling. The potential and the electric field distributions along this insulator are simulated under various conditions: the two cases: clean and polluted insulators and applying different conductivity values. We used electrostatic 2D simulations in the AC/DC module. The results are auspicious and promising.
PL
Przedmiotem referatu jest przedstawienie zaawansowanych rozwiązań technologicznych architektury systemu zasilania wysokiego napięcia prądu stałego HVDC (High Voltage Direct Current) w zakresie napięć 540 VDC (±270 VDC) oraz 350 VDC poprzez dokonanie analizy literatury przedmiotu oraz analizy i symulacji wybranego jej komponentu zgodnie z koncepcją samolotu bardziej/ w pełni elektrycznego MEA/ AEA.
EN
The subject of this paper is to present the most advanced technology to system architecture of high voltage power HVDC (High Voltage Direct Current) in the range of voltages 540 VDC (±270 VDC) and 350 VDC by making a critical analysis of the literature and the analysis and simulation of its selected component according to the concept of more/ full electric aircraft MEA/ AEA.
EN
Flashover of polluted insulators has been the subject of many experimental and numerical research papers. Several mathematical models of flashover voltage have been proposed in terms of current, discharge length, electrolyte length and resistivity. However, there is no model as yet based on the geometric factors of the electrolyte channel-such as width and depth-and the interaction between them. Furthermore, as very few research papers have been published about discharge elongation in the presence of a metal object between the electrodes, the aim of the present work is to model flashover voltage in the presence of a metal plate, dipped in electrolyte or placed on its surface. Two mathematical models were obtained using response surface modeling and they were used in the analysis of the effect of geometric factors on the flashover discharge.
first rewind previous Strona / 4 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.