Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 19

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  generacja wiatrowa
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote The analysis of the wind generation impact on the power system stability
EN
The article discusses the issues related to the influence of connecting wind turbines on the angular stability of the power system. Current plans for Poland's energy transition, climate issues, and the most popular types of wind turbines used in the world were discussed. In the study part, the impact of replacing traditional generating units with wind turbine systems connected by converters on the angular stability of the New England test model was analysed.
PL
W artykule zostały omówione zagadnienia dotyczące wpływu przyłączania turbin wiatrowych na stabilność kątową systemu. Omówiono aktualne plany dotyczące transformacji energetycznej Polski, kwestie klimatyczne, a także najpopularniejsze rodzaje turbin wiatrowych, wykorzystywanych na świecie. W części badawczej przeanalizowano wpływ zastępowania tradycyjnych jednostek wytwórczych układami turbin wiatrowych przyłączanych przez przekształtniki na stabilność kątową modelu testowego systemu New England.
PL
W artykule przedstawiono wyniki analiz dotyczących możliwości wykorzystania zasobników energii do kompensowania błędów generacji wiatrowej w horyzoncie średnioterminowym w celu poprawy jakości planowania pracy i obniżenia kosztów funkcjonowania systemu elektroenergetycznego. Zaprezentowano metodykę określania preferowanych typów elektrochemicznych magazynów energii na podstawie techniczno–ekonomicznych wskaźników optymalizacji uwzględniających m.in.: charakterystyki czasu życia zasobnika (liczba cykli przy określonym poziomie rozładowania), sprawności cyklu ładowanie - rozładowanie oraz nakładów inwestycyjnych.
EN
Possibility of using energy storage to balance the short and mid-term variability of wind generation in order to improve the quality of planning process and reduce the cost of power system operation was presented in this paper. Continuous rise of wind generation installed capacity causes increase problems associated with power system balancing. One of the countermeasures may be battery energy storage systems (BESS). The aim of the analysis was to determine the preferred battery energy storage system (BESS) technologies based on indicators of energy storage nominal power to wind generation installed capacity (MWES / MWGW) and required energy storage capacity (Q) in relation to its power (Q / P ES). Minimum values of technical or financial indicators were used to identify the optimal solution. The simulations were made taking into account the energy storage lifetime resulting from the number of cycles and depth of discharge. To determine the required BESS parameters were performed short and mid-term wind generation variability compensation simulations for selected, commercially available BESS technologies: sodium - sulfur (NaS), lithium-ion (Li-ion) and lead acid (PbAcid).
PL
W artykule opisano wyniki przeprowadzonego badania wpływu generacji ze źródeł wiatrowych na kształtowanie się poziomu cen na rynku fizycznym spot dla energii elektrycznej. Opracowany model wykorzystano do oceny wpływu dynamiki przyrostu mocy zainstalowanej i sprawności źródeł na poziom cen. W referacie przedstawiono także historyczną zmienność wpływu generacji wiatrowej oraz rekomendacje handlowe.
EN
The article describes the results of conducted analysis concerning the impact of wind sources generation on the level of electricity prices on the physical SPOT market. Developed model was used to assess the impact of the growth rate of the installed capacity and the efficiency of sources on the electricity price level. The paper also presents the historical volatility of the impact of wind generation and trading recommendations as well.
EN
Development of wind generation, besides its positive aspects related to the use of renewable energy, is a challenge in terms of operational security and economy of the National Power System (NPS). The uncertain and variable nature of wind generation sources (WG) entails the need to ensure by the TSO adequate power reserves, necessary to maintain the stable power system operation. Entities involved in energy trading from these sources incur additional balancing costs of unplanned production deviations. Continuous rise of WG installed capacity causes increase the problems associated with power system balancing. One of the solution may be energy storage systems. The paper presents the results of analyses of the possible use of electrochemical energy storage systems to balance WG variability as a tool to support the power system operation planning, in order to reduce the operating costs of the NPS. The method of determining the preferred types of electrochemical energy storage systems, basis on the technical and economic optimisation indicators was shown in this article.
PL
Rozwój generacji wiatrowej oprócz pozytywnych aspektów związanych z wykorzystaniem energii odnawialnej stanowi wyzwanie z punktu widzenia bezpieczeństwa i ekonomiki funkcjonowania Krajowego Systemu Elektroenergetycznego (KSE). Niepewny i zmienny charakter źródeł generacji wiatrowej (GW) pociąga za sobą konieczność zapewnienia przez OSP odpowiednich rezerw mocy, niezbędnych dla zachowania stabilnej pracy sieci. Podmioty zaangażowane w handel energią z tych źródeł ponoszą dodatkowe koszty bilansowania nieplanowanych odchyleń produkcji. Ciągły wzrost mocy zainstalowanej GW powoduje nasilenie problemów związanych z bilansowaniem systemu, a rozwiązaniem mogą być zasobniki energii. W artykule przedstawiono wyniki analiz dotyczących możliwości wykorzystania elektrochemicznych zasobników energii do bilansowania zmienności GW jako narzędzia wspomagającego planowanie pracy systemu i służącego obniżeniu kosztów funkcjonowania KSE. Zaprezentowano sposób wyznaczania preferowanych typów elektrochemicznych zasobników energii, określanych na podstawie techniczno-ekonomicznych wskaźników optymalizacyjnych.
EN
Intensive development of distributed generation, apart from the positive aspects related to the use of renewable energy, is also a challenge in terms of safety and reliability of energy supply. Ensuring the reliability of supplies, at the variable operation of wind generation and photovoltaic generation, requires from the network operators implement additional costly investments. An alternative solution is to build a system that integrates management of local energy resources (including automatic grid controls, energy storage, local energy sources) in order to optimize the technical possibilities of the grid.
PL
Intensywny rozwój generacji rozproszonej, oprócz pozytywnych aspektów związanych z wykorzystaniem energii odnawialnej, stanowi wyzwanie z punktu widzenia bezpieczeństwa i funkcjonowania Krajowego Systemu Elektroenergetycznego (KSE). Zapewnienie niezawodności dostaw, przy zmiennym charakterze pracy generacji wiatrowej i fotowoltaicznej, wymusza na operatorach sieci konieczność realizacji dodatkowych kosztownych inwestycji sieciowych. Alternatywnym rozwiązaniem jest budowa systemu umożliwiającego zintegrowane zarządzanie lokalnymi zasobami energetycznymi (m.in. automatyką sieciową, magazynami energii, lokalnymi źródłami energii) w celu optymalizacji technicznych możliwości sieci elektroenergetycznej.
EN
This paper presents the results of an analysis of the interdependence of wind generation output and photovoltaic generation potential in the ENERGA-OPERATOR SA grid. The first study of the interdependence of these two types of renewable sources’ generation outputs was carried out by the Gdańsk Branch of the Institute of Power Engineering in cooperation with ENERGA-OPERATOR in 2012. An important conclusion of the study was the need to repeat the analysis for a larger set of input data as the study covered the period of one year only, and for obvious reasons a limited number of wind farms. The present study’s inputs included a period of four years and more wind farms, due to the continuous connecting of new facilities to the grid. Thus, the results are characterized by a much higher level of credibility, and allow drawing more correct conclusions regarding the analysed interdependence. The research on the interdependence of the annual wind generation output and potential generation from photovoltaic sources indicates that both generation types are characterized by mutual spatio-temporal dependency. In the study the relationship was quantified by evaluation of the maximum actual wind generation output in specific areas in the case of high PV generation output in a given area and vice versa. The results may allow for appropriate (i.e. substantiating the modelled operating conditions of the system in relation to reality) consideration of both types of sources in various types of system analyses of their impact on the grid performance, such as interconnection studies for new sources and distribution grid development planning.
PL
W artykule zostały przedstawione wyniki analizy współzależności poziomów generacji wiatrowej i potencjalnej generacji fotowoltaicznej na obszarze sieci ENERGA-OPERATOR SA. Pierwsze badania dotyczące przedmiotowej zależności poziomów generacji, wspomnianych dwóch rodzajów źródeł odnawialnych, zostały przeprowadzone przez Instytut Energetyki Oddział Gdańsk we współpracy z operatorem w 2012 roku. Jednym z ważnych wniosków pracy było wskazanie konieczności powtórzenia analizy dla większego zbioru danych wejściowych, ponieważ studium obejmowało okres jednego roku i ograniczoną z oczywistych względów liczbę lokalizacji farm wiatrowych. W prezentowanych badaniach dane wejściowe obejmowały okres czterech lat oraz większą liczbę farm wiatrowych, ze względu na ciągłe przyłączanie kolejnych obiektów do sieci. Tym samym otrzymane wyniki charakteryzują się znacznie wyższym poziomem wiarygodności oraz pozwalają na wyciągnięcie bardziej prawidłowych wniosków dotyczących współzależności będącej przedmiotem badania. Z przeprowadzonych badań zależności rocznych przebiegów poziomów generacji wiatrowej i potencjalnej generacji ze źródeł fotowoltaicznych wynika, że oba typy generacji charakteryzują się wzajemną obszarową zależnością. W ramach pracy związek ten został skwantyfikowany poprzez wyznaczenie wartości maksymalnego realnego poziomu generacji wiatrowej na poszczególnych obszarach w przypadku wysokiej generacji PV na danym obszarze i vice versa. Otrzymane wyniki mogą pozwolić na właściwe (uprawdopodobniające modelowane stany pracy systemu w stosunku do rzeczywistości) uwzględnianie obu typów źródeł w różnych rodzajach analiz systemowych, badających ich wpływ na sieć, takich jak analizy przyłączeniowe nowych źródeł czy planowanie rozwoju sieci dystrybucyjnej.
PL
W artykule przedstawione zostały wyniki analizy współzależności poziomów generacji wiatrowej i potencjalnej generacji fotowoltaicznej na obszarze sieci ENERGA-OPERATOR SA. W roku 2012 Instytut Energetyki Oddział Gdańsk we współpracy z ENERGA-OPERATOR SA przeprowadził pierwsze badania dotyczące zależności poziomów generacji ww. rodzajów źródeł odnawialnych. Jednym z wniosków pracy było wskazanie konieczności powtórzenia analizy dla większego zbioru danych wejściowych, jako że studium obejmowało okres jednego roku i ograniczoną z oczywistych względów liczbę lokalizacji farm wiatrowych. W prezentowanych badaniach dane wejściowe obejmowały okres czterech lat oraz większą liczbę farm wiatrowych, z uwagi na ciągłe przyłączanie kolejnych obiektów do sieci. Otrzymane wyniki charakteryzują się znacznie wyższym poziomem wiarygodności oraz pozwalają na wyciągnięcie bardziej prawidłowych wniosków dotyczących współzależności będącej przedmiotem badania. Z przeprowadzonych badań zależności rocznych przebiegów poziomów generacji wiatrowej i potencjalnej generacji ze źródeł fotowoltaicznych wynika, że oba typy generacji charakteryzują się wzajemną, obszarową zależnością. W ramach pracy związek ten został skwantyfikowany poprzez wyznaczenie wartości maksymalnego realnego poziomu generacji wiatrowej na poszczególnych obszarach w przypadku wysokiej generacji PV na danym obszarze i vice versa. Otrzymane wyniki mogą pozwolić na uprawdopodobniające modelowane stany pracy systemu w stosunku do rzeczywistości obu typów źródeł w różnych rodzajach analiz systemowych badających ich wpływ na sieć.
EN
This paper presents the results of a study aiming to analyze the correlation between output levels of generation of wind farms located in northern Poland (area where the grid is operated by ENERGA-OPERATOR SA) and potential photovoltaic installations in the same area. With the recent increase of interest in investing in PV in Poland, it has become very important to investigate the likelihood of wind and PV generation installed over a large area to generate a high level of power simultaneously. The first study investing the potential correlation of mentioned two types of renewable sources in the area has been performed by the Institute of Power Engineering in cooperation with ENERGA-Operator SA in 2012. Nevertheless, as the previous study covered a period of only one year, due to a limited amount of available data, it has become necessary to continue the analysis as more data becomes available with new wind farms being connected to the grid. In this paper, the findings of a new study, where data from a four-year period was used, are presented.
PL
Polityka energetyczna Polski określa, że do 2030 roku około 7% generacji energii w kraju ma pochodzić ze źródeł wiatrowych. Artykuł nakreśla wyzwania związane z prognozowaniem generacji z tego źródła energii. Celem artykułu jest przestawienie metodyki i wyników prognozowania generacji energii ze źródeł wiatrowych, w której nowatorsko połączono trzy metody prognozowania. W pierwszym etapie wykorzystano regresję nieliniową opartą na funkcji logistycznej do budowy profilu generacji turbiny. Etap drugi oparto o regresję lokalną, która buduje właściwy model prognostyczny. W ostatnim kroku wykorzystano metodę korekty błędem w celu minimalizacji błędów prognozy wynikających z nietypowego zachowania turbiny. Metodyka prezentowana w artykule jest wynikiem projektu Future Energy Management System, w którym m.in. przebadano dane generacji z dużej farmy wiatrowej zlokalizowanej w zachodniej Polsce. Ponadto, artykuł wskazuje na wyzwania związane ze zmiennością czynników atmosferycznych i zużyciem własnym siłowni wiatrowej, które często w wyniku braku sprofilowania turbiny jest także trudno przewidywalne.
EN
The Energy Policy for Poland states that by 2030 about 7% of power generation in the country will have to be provided from the wind. This article describes challenges associated with forecasting the energy generation from this energy source. The purpose is to present the methodology, together with forecasting results, which innovatively combined three methods of forecasting. In the first step of the methodology, we use non-linear regression based on the logistic function to construct the profile of turbine energy generation. The second stage is based on the local regression that contributes to the main forecasting model. In the last step the error correction method was used to minimize the forecast errors resulting from the abnormal behavior of the turbine. The methodology presented in the article is a result of Future Energy Management System Project, in which among others, research using data of a large wind farm located in western Poland was performed. In addition the article discusses the challenges of the variability of the weather and related wind turbine energy consumption, which is often difficult to predict due to the lack of turbine profiles.
EN
The objective of the analysis was the quality of electric energy in the place of attachment of a single wind power plant to the electricity grid. This objective was performed based on the author's own research carried out in a LV switching station located in the place of attachment of a wind turbine with the power 150 kW to the MV distribution network. The object of the research was located in the northern part of Małopolskie Voivodeship. The assessment of the quality of electric energy was carried out based on the requirements set forth in the Ordinance of the Minister of Economy on detailed conditions of functioning of the power system and the Manual of Movement and Operation of Distributive Network. Based on the analysis, which was carried out, one may assume that the requirements referring to frequency changes, efficient value of the supply voltage, voltage unbalance and its deformation from the sinusoidal waveform have been met. In the period which was covered by the research, during the wind turbine work, insignificant surpasses of the admissible level of the root mean square of voltage were reported, but their number constituted less than 0.07% of observations. During the research, also 20 voltage dips of values exceeding 10% of the rated voltage, average depth of which was 172V were reported. In majority these were disruptions caused by other receivers connected to the network.
PL
Celem pracy była analiza jakości energii elektrycznej w miejscu przyłączenia pojedynczej siłowni wiatrowej do sieci elektroenergetycznej. Cel ten zrealizowano na podstawie badań własnych wykonanych w rozdzielni nN, zlokalizowanej w miejscu przyłączenia siłowni wiatrowej o mocy 150 kW do sieci rozdzielczej SN. Obiekt badań był zlokalizowany w północnej części województwa małopolskiego. Oceny jakości energii elektrycznej dokonano w oparciu o wymagania zawarte w Rozporządzeniu Ministra Gospodarki w sprawie szczegółowych warunków funkcjonowania systemu elektroenergetycznego oraz Instrukcji Ruchu i Eksploatacji Sieci Dystrybucyjnej. Na podstawie wykonanych analiz można uznać, że wymagania odnośnie zmian częstotliwości, wartości skutecznej napięcia zasilającego, asymetrii napięcia oraz jego odkształcenia od przebiegu sinusoidalnie zmiennego zostało spełnione. W okresie objętym badaniem podczas pracy siłowni wiatrowej rejestrowano nieznaczne przekroczenia dopuszczalnego poziomu wartości skutecznej napięcia, ale ich liczba stanowiła niespełna 0,07% obserwacji. W czasie badań zarejestrowano również 20 zapadów napięcia o wartościach przekraczających 10% napięcia znamionowego, których średnia głębokość wynosiła 172V. W większości były to zakłócenia, których źródłem są inne odbiorniki przyłączone do sieci.
EN
The paper presents a new approach to the problem of optimizing wind generation distribution in cases of overloads in the grid caused by high level of wind generation. The approach is based on a modified and enhanced version of a genetic algorithm presented at the previous “Aktualne Problemy w Elektroenergetyce” (APE) [Present-Day Problems of Power Engineering] conference in 2011. The idea of coherent a grid nodes is introduced in order to optimize generation levels for groups of wind farms instead of individual wind farms, enabling grid operators to distribute power reduction among wind farms in a more equal manner, which can result in enabling larger wind generation penetration in grid with low transmission capacities. The test results as well as results obtained using the algorithm for a real-life, large-scale case are also presented.
PL
Autorzy prezentują nową metodę wyznaczania optymalnego rozkładu generacji wiatrowej, opartą na rozwinięciu algorytmu genetycznego – prezentowanego podczas konferencji „Aktualne Problemy w Energetyce” w 2011 roku (APE) – o ideę koherentnych węzłów sieci. Metoda pozwala na bardziej równomierne rozłożenie redukcji mocy między pobliskie farmy, przy jednoczesnym zachowaniu zalet oryginalnego podejścia. Nowy algorytm optymalizuje poziomy generacji zdefiniowanych a priori grup farm. W artykule prezentowane są również wyniki uzyskane za pomocą algorytmu w trakcie symulacji przewidywanej pracy sieci północnej Polski w horyzoncie kilku lat.
PL
W artykule prezentowana jest nowa metoda wyznaczania optymalnego rozkładu generacji wiatrowej, oparta na rozwinięciu prezentowanego na konferencji APE’11 algorytmu genetycznego o ideę koherentnych węzłów sieci. Metoda pozwala na bardziej równomierne rozłożenie redukcji mocy między pobliskie farmy przy jednoczesnym zachowaniu zalet oryginalnego podejścia. Nowy algorytm optymalizuje poziomy generacji zdefiniowanych a priori grup farm. W artykule prezentowane są również wyniki uzyskane za pomocą algorytmu w trakcie symulacji przewidywanej pracy sieci północnej Polski w horyzoncie kilku lat.
EN
The paper presents a new approach to the problem of optimizing wind generation distribution in case of overloads in the grid caused by high level of wind generation. The approach is based on modified and enhanced genetic algorithm presented at the previous APE conference in 2011. The idea of coherent grid nodes is introduced in order to optimize generation levels for groups of wind farms instead of individual wind farms, enabling grid operators to distribute power reduction among wind farms in a more equal manner, which can result in enabling larger wind generation penetration in grid with low transmission capacities. The test results as well as results obtained using the algorithm for a real-life, large-scale case are also presented.
PL
Przedstawiono aspekty oddziaływania generacji wiatrowej na system elektroenergetyczny w przypadku różnych sytuacji ruchowych na podstawie rzeczywistych rejestracji dokonanych podczas testów odbiorczych.
EN
The paper presents aspects of influence of wind power plants on electric power system in different operational conditions - taking advantage of real records made during acceptance tests.
PL
W artykule dokonano oceny możliwości wytwórczych farm wiatrowych mających powstać na terenie województwa lubelskiego, w oparciu o przebiegi prędkości wiatru z lat 2006, 2007, 2008 uzyskane z atlasu wiatru AnemosŽ. Otrzymane wyniki poddano analizie i przedstawiono realne do osiągnięcia przez te farmy wartości mocy oraz energii elektrycznej.
EN
In this article we discuss the possibilities of electricity generation by wind farms settled in lubelskie province. Our study are based on detailed wind velocities map of Poland - AnemosŽ. We analyzed data in period from 2006 to 2008 and calculated feasible values of power and energy that may be obtained from the wind farms in chosen locations of province.
PL
W artykule przedstawiono wyniki analizy pracy farm wiatrowych w Polsce, po osiągnięciu hipotetycznego poziomu 12000 MW mocy zainstalowanej. Wykorzystano lokalizacje farm określone na podstawie uzyskanych warunków przyłączenia do sieci oraz warunki wietrzności określone za pomocą systemu Anemos. Na podstawie tych warunków dla każdej lokalizacji oszacowano, że maksymalny poziom generacji wiatrowej (9000 MW) może wystąpić nie dłużej niż 1000 godzin rocznie, natomiast przez blisko 6000 godzin w roku moc generowana nie przekroczy 4000 MW. Wyniki te powinny być brane pod uwagę przy szacowaniu oddziaływania energetyki wiatrowej na system elektroenergetyczny. W artykule do-konano także analizy możliwych do wystąpienia ograniczeń bilansowych generacji wiatrowej na podstawie hipotetycznego obciążenia KSE w roku 2020. Celem niniejszego artykułu było także przeanalizowanie dynamiki zmian obciążenia SEE oraz próba odpowiedzi na pytanie, czy generacja wiatrowa znacząco pogarsza warunki pracy jednostek konwencjonalnych, co często jest podnoszone przez jej przeciwników.
EN
The paper shows the results of analysis taking into account wind generation of 12 000 MW installed power in Poland by the 2020 year. Wind farms with issued actual conditions of interconnection into the HV grid have been taken into consideration. Generated power variation analysis has shown that the maximal level of wind generation (9,000 MW) is expected over 1,000 hours of the year, while the rest of 6,000 hours a year of total generated wind power have been expected lower than 4,000 MW. Those results should be taken into consideration when estimating an influence of wind generation on a power system. In this article the analysis of potential power system balance limitations for wind farms have been elaborated based on appropriate scaling of system load to level for year 2020 and estimated wind generation. The aim of this work was also an analysis of mean hour load gradients of the power system before and after interconnecting the mentioned 12 000 MW of wind generation to the system and an attempt to answer the question whether the wind generation, would be destabilizing to power system or would not.
PL
W referacie przedstawiono analizę możliwości przesyłowych linii napowietrznych wykorzystując tzw. dynamiczną obciążalność termiczną linii. Obciążalność ta jest m.in. zależna od prędkości wiatru chłodzącego przewody. Powiązanie możliwości wykorzystania rezerw przesyłowych wynikających z większych prędkości wiatru niż przyjęta projektowo sprzyja źródłom wykorzystujących wiatr jako energię pierwotną. Referat zawiera wyniki obliczeń opartych na rzeczywistych danych pomiarowych oraz ocenę obszarową jednolitości tych danych. Na podstawie tych wielkości oceniono w tych warunkach rzeczywistą obciążalność linii napowietrznych oraz potencjał wytwórczy elektrowni wiatrowych.
EN
The analysis of overhead lines capacity based on dynamic thermal line rating was presented in the paper. Dynamic thermal rating is directly connected with wind velocity thus the wind power plants are beneficiaries of this effect. The paper presents some calculations based on measured wind velocity concerning assessment of area dimension. The calculations show increasing of line rating in accompany with in increasing of potential wind generation.
PL
W artykule przedstawiono model matematyczny optymalizacji węzłowej generacji wiatrowej w sieci przesyłowej. Funkcją celu jest maksymalna sumaryczna generacja wiatrowa przy spełnieniu następujących ograniczeń: dopuszczalne obciążenie linii i transformatorów, dopuszczalne saldo wymiany zagranicznej, regulacyjne minimum techniczne mocy w elektrowniach konwencjonalnych. Rozważania zilustrowano przykładem obliczeniowym.
EN
This article presents the mathematical model of node optimisation for wind generation in the transmission grid. The target function is the maximum summary wind generation with compliance with the following bounds the permissible load of lines and transformers, the permissible foreign exchange balance, the minimum technical regulating power at conventional power plants. The considerations are illustrated by an example calculation.
PL
W artykule dokonano oceny możliwości energetyki wiatrowej w Polsce, w oparciu o przebiegi prędkości wiatru z lat 2006, 2007, 2008 uzyskane z atlasu wiatru Anemos. Pod uwagę wzięto farmy wiatrowe które posiadają aktualne warunki przyłączenia do sieci WN. Analiza uwzględnia typy turbin wiatrowych przewidzianych do instalacji w farmach. Uzyskane wyniki poddano analizie oraz postawiono wnioski mające na celu określenie realnych wartości mocy i energii, która może być wprowadzona do systemu elektroenergetycznego jako efekt pracy tych obiektów.
EN
The abilities of wind power generation in Poland based on wind speed variations obtained from Anemos Wind Atlas for Poland from 2006, 2007 and 2008 year was inspected. The wind farms with issued actual conditions of interconnection into the HV grid was taken into consideration. The analysis took into account different wind turbine types planned to be installed on mentioned farms. Achieved results was analyzed and conclusions were proposed in order to determine real values of powers and energies which could be injected into the system as a result of its operation.
PL
W artykule przedstawiono możliwości przesyłowe linii napowietrznych wykorzystujące tzw. dynamiczną obciążalność termiczną linii. Obciążalność ta jest m.in. wypadkową prędkości wiatru chłodzącego przewody. Powiązanie możliwości wykorzystania rezerw przesyłowych wynikających z większych prędkości wiatru niż przyjęta projektowo sprzyja źródłom wykorzystujących wiatr jako energię pierwotną. Praca źródła wiatrowego z mocą znamionową wymaga wiatru o odpowiedniej prędkości, a ta z kolei determinuje obciążalność linii napowietrznej. W referacie przedstawiono wy-niki obliczeń związanych z symulacją warunków wiatrowych właściwych stanom pracy źródła wiatrowego i określonej w tych warunkach obciążalności dynamicznej. Celem referatu jest zaproponowanie weryfikacji kryteriów wykorzystywanych w ocenie wpływu farm wiatrowych na sieć elektroenergetyczną w stanach ustalonych.
EN
Transmission capacity of overhead lines using dynamic thermal line rating is presented in the paper. The rating of the overhead lines depends strongly on speed of the wind cooling the line conductors. There are significant reserves of transmission capacity at increased wind velocity. This reserves can be used at generation in wind power plants. Generators accomplish 100% of the nominal power at wind velocity over 10 m/s. This level of the wind speed can determine even several times bigger line rating. Different wind conditions and as a result different power generation and line rating were simulated by authors of the paper. Most important results are presented in the article. Assessment of the influence of the wind power plant on the power network is required before the power plant connection. One of the main goals is the verification and review of criteria using at the assessment.
PL
W artykule krótko scharakteryzowano aktualny stan rozwoju źródeł wiatrowych w Polsce i na świecie. Wskazano, że ze względu na znaczącą zmienność czasową mocy generowanej przez źródła wykorzystujące tę technologię, konieczne jest zwiększenie wymaganych ilości operacyjnych rezerw mocy, obejmujących rezerwy: sekundową minutową i godzinową. Dokonano przeglądu doświadczeń światowych w tym zakresie. Przy wykorzystaniu metody łącznego zakupu energii bilansującej i operacyjnych rezerw mocy oszacowano koszty wynikające z konieczności utrzymania dodatkowych ilości rezerw w KSE, spowodowanej zwiększonym udziałem generacji wiatrowej.
EN
The paper presents a short description of the current state of wind power generation in Poland and in some other countries in different parts of the world. It was stated that because of significant variability of power generation it is necessary to keep additional amount of operating reserves (including second, minute and hour reserves). In the paper an overview of foreign experiences on that subject is presented. The paper also presents an estimated value of operating reserve costs in Polish power system with increasing wind power generation. The results were obtained by using a method of cooptimization of the balancing energy and operating reserves.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.