Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 54

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  fan
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
In the present paper, the problem of estimating the contingent cone to the solution set associated with certain set-valued inclusions is addressed by variational analysis methods and tools. As a main result, inner (resp. outer) approximations, which are expressed in terms of outer (resp. inner) prederivatives of the set-valued term appearing in the inclusion problem, are provided. For the analysis of inner approximations, the evidence arises that the metric increase property for set-valued mappings turns out to play a crucial role. Some of the results obtained in this context are then exploited for formulating necessary optimality conditions for constrained problems, whose feasible region is defined by a set-valued inclusion.
EN
A fan with a cycloidal rotor (CRF) is a promising design for application in HVAC (heat, ventilation and air conditioning) systems. Despite the widespread use of the CRF design as a form of propulsion, there are practically no scientific publications examining the possibility of using it as the HVAC fan. The choice of the cycloidal rotor facilitates the operating procedure and widens the range of operating conditions. The paper focuses on the use of the CRF in HVAC, especially as a blowing machine integrated with rectangular ducts, presenting, and discussing the search for the most efficient numerical model. The way of discretizing the computational domain, the turbulence models and the time integration method were tested. A four-blade open rotor fan with a cycloidal impeller was used both in the numerical and in the experimental model. The 2D and 3D CRF models created in the Ansys CFX package were adopted. After a mesh-independence study, different turbulence models were tested for the selected mesh. In the case of the 2D model, various turbulence models such as the SST and the RNG k-ε options were tested and compared with each other. The computational fluid dynamics simulations were compared with in-house experimental results of the velocity field measurements performed by means of laser Doppler anemometry and thermoanemometry. It turned out that the considered numerical models did not reflect the experimental measurements quantitatively. This may be due to the small differences in the shapes of the cycloids of the rotor blades in the numerical model and in real geometry.
3
Content available Energooszczędne wentylatory promieniowe
PL
W pracy pokazano trzy wentylatory promieniowe charakteryzujące się małym poborem energii. Wentylatory te wyposażone zostały w nowy układ napędowy, składający się z bezszczotkowego silnika prądu stałego i energoelektronicznego układu (falownika) sterującego pracą silnika. Pokazano konstrukcję silnika użytego w wentylatorach, na który zużyto znacznie mniej żelaza i miedzi w porównaniu z silnikami dotychczas stosowanymi. Omówiono zasadę sterowania bezczujnikowego zastosowaną w falowniku oraz pokazano prototyp falownika. Porównano pobory mocy wentylatorów dotychczas stosowanych z wentylatorami wyposażonymi w nowe układy napędowe. Opracowane wentylatory przeznaczone są do pracy przy piecach centralnego ogrzewania, w ekstruderach do produkcji butelek PET oraz w układach klimatyzacji. Zużywają one ponad dwukrotnie mniej energii niż urządzenia stosowane obecnie.
EN
The paper presents three centrifugal fans with low power consumption. The fans are equipped with a new drive system consisting of a brushless DC motor and power electronics system (inverter) used for motor control. The construction of the motor required much less iron and copper than the present motors. The principle of sensorless control of inverter is discussed and the prototype of the inverter is presented. The power consumption of the existing fans and the ones equipped with new drive systems is compared. The developed fans are designed to work with central heating furnaces, in extruders for the production of PET bottles, and in air-conditioning systems. They consume over twice as little energy as currently used fans.
PL
W artykule zaprezentowano badanie doświadczalne z dziedziny wentylacji, przeprowadzone w Małopolskim Laboratorium Budownictwa Energooszczędnego z wykorzystaniem metody Stereo Particle Image Velocimetry (Stereo PIV). Opisano wyposażenie laboratorium badawczego obejmujące system PIV, a także metodę. Zaprezentowano wstępne wyniki doświadczeń ze strumieniami powietrza wypływającego z nawiewnej kratki wentylacyjnej, stosowanej w typowym budownictwie mieszkaniowym.
EN
The article presents an experimental study in the field of ventilation, carried out in the Malopolska Laboratory of Energy Efficient Buildings. Stereo Particle Image Velocimetry (Stereo PIV) method was used in the experiment. The specification of the equipment of the research laboratory including the PIV system was included, as well as a brief description of the method. Preliminary results of the tests of the air stream flowing out of the ventilation grille used in typical housing construction have been presented.
5
Content available Energooszczędne wentylatory promieniowe
PL
W pracy pokazano trzy wentylatory promieniowe charakteryzujące się małym poborem energii. Wentylatory te wyposażone zostały w nowy układ napędowy składający się z bezszczotkowego silnika prądu stałego i energoelektronicznego układu (falownika) sterującego pracą silnika. Pokazano konstrukcję silnika użytego w wentylatorach, na który zużyto znacznie mniej żelaza i miedzi w porównaniu z silnikami dotychczas stosowanymi. Omówiono zasadę sterowania bezczujnikowego zastosowaną w falowniku oraz pokazano prototyp falownika. Porównano pobory mocy wentylatorów dotychczas stosowanych z wentylatorami wyposażonymi w nowe układy napędowe. Opracowane wentylatory przeznaczone są do pracy przy piecach centralnego ogrzewania, w ekstruderach do produkcji butelek PET oraz w układach klimatyzacji. Zużywają one ponad dwukrotnie mniej energii niż urządzenia stosowane obecnie.
EN
The paper presents three centrifugal fans with low power consumption. The fans are equipped with a new drive system consisting of a brushless DC motor and power electronics system (inverter) used for motor control. The construction of the motor required much less iron and copper than the present motors. The principle of sensorless control of inverter is discussed and the prototype of the inverter is presented. The power consumption of the existing fans and the ones equipped with new drive systems is compared. The developed fans are designed to work with central heating furnaces, in extruders for the production of PET bottles, and in air-conditioning systems. They consume over twice as little energy as currently used fans.
PL
Scharakteryzowano emisję hałasu z hutniczych urządzeń cieplnych. Przeanalizowano wyniki badań hałasu wentylatora powietrza bez i z zainstalowaną obudową dźwiękochłonną. Porównano wyniki badań widm hałasu palnika spalającego paliwo ciekłe – olej lekki z danymi literaturowymi palnika spalającego butan. Przedstawiono możliwości wykorzystania charakterystyk akustycznych wentylatorów i widm hałasu z procesów spalania do szybkiej, bezinwazyjnej diagnostyki eksploatacyjnej hutniczych urządzeń cieplnych.
EN
Noise emission from metallurgical thermal devices has been characterized. The results of the noise analysis of the air fan were analyzed without and with sound absorbing housing installed. The results of the noise spectra of the liquid fuel burner - light oil were compared with the literature data of the butane burner. The possibilities of using acoustic characteristics of ventilators and octave spectras of noise from combustion processes for fast, noninvasive operational diagnostics of metallurgical thermal equipment’s were presented.
PL
Wentylatory to maszyny przepływowe służące do przetłaczania par i gazów. Stosowane są powszechnie w instalacjach klimatyzacyjnych, chłodniczych, odpylających, suszarniczych i wielu innych. Dla właściwego doboru wentylatora do określonych zastosowań, jak również w ocenie prawidłowości jego pracy niezbędna jest znajomość jego charakterystyki.
PL
Pojęcie efektywności według słowników i encyklopedii pozwala wyróżnić ok. stu synonimów. W praktyce technicznej elektrycznych układów napędowych często się używa tego pojęcia. Najłatwiej zrozumieć pojęcie efektywności energetycznej, gdyż ściśle jest związane ze sprawnościami poszczególnych elementów układu napędowego. Najprościej chyba przyjąć, że efektywność to rezultat podjętych działań opisany relacją uzyskanych efektów do poniesionych nakładów. Oznacza to najlepsze efekty. To powyższe stwierdzenie często jest przedstawiane w słownikach.
PL
W artykule opisano główne procesy technologiczne występujące w magazynie przechowalniczym ziarna. Zwrócono uwagę na zagrożenia zmian jakościowych ziarna wynikające z nieprawidłowego przechowywania i przewietrzania ziarna. Przedstawiono nowe dodatkowe urządzenia techniczne magazynów przechowalniczych w szczególności agregaty chłodnicze, urządzenia mieszające i rozrzutniki ziarna. Słowa kluczowe: przechowalnictwo ziarna, agregat chłodniczy, mieszalnik, wentylator, rozrzutnik.
EN
The article describes the main processes occurring in the grain storing warehouse. Attention was paid to dangers of qualitative changes of grain due to its improper storage and bad ventilation. Article presents new additional technical equipment for storage warehouses in particular chillers, mixing devices and grain spreaders.
10
Content available remote Characteristics of fans used in low-power boilers
EN
This paper presents the results of tests conducted in the Chair of Thermal Engineering of Poznan University of Technology dedicated to determining the efficiency of low-power barrel fans, which are used in low-power boilers. Operation parameters of fans produced for industry were checked with respect to the requirements of Directive 2009/125/EC of the European Parliament. The tests were used to determine the efficiency of fans and to compare them against values determined according to the European Directive. The test results are presented on graphs as functions of air volume flow. Those characteristics comprise distributions of total pressure, electric power absorbed by the motor, and fan efficiency. The results indicate that there is a need to develop new guidelines. They should concern those efficiencies of low-power fans which are not covered by Directive 2009/125/EC of the European Parliament.
PL
W pracy omówione zostały wybrane metody pomiarów drgań maszyn wirujących (silników, wirników wentylatorów, przekładni mechanicznych, itp.) zastosowanych do oceny stanu maszyn pracujących w warunkach przemysłowych. Przedstawiono zastosowaną aparaturę badawczą pozwalającą na zebranie danych do analizy. Na przykładzie pomiarów drgań łożysk wentylatora promieniowego typu WPK-3,9 pracującego w stacjach wentylatorów głównych w przemyśle górniczym przedstawiono analizę drgań, dzięki której określono stan techniczny wirujących części wentylatora.
EN
The work presents selected methods of vibration measurement of rotating machines (motors, fan rotors, mechanical gears, etc.) used to evaluate the condition of machines operating in industrial conditions. Presented research apparatus used to record data for analysis. Based on measurements of the vibrations of radial fan bearings type WPK-3.9 operating in mining factory a vibration analysis was presented, which determined the technical condition of the fan.
EN
The article discusses the problem how forced air flow is implemented through the cooling module of heavy-duty engines. The kinematic connection between the coolant pump and the crankshaft of the engine, results in the fact that the pump performance often does not correspond to the engine demand at its part load. In conjunction with the fan drive method, the temperature of the coolant may be too low or too high for part load. The study was carried out in order to calculate the parameters of the cooling system in heavy-duty engines for maximum power and maximum torque, taking into account a mechanical fan drive, a hydraulic fan drive and an electric fan drive.
13
Content available remote A fan for solid-fuel furnaces
EN
The paper presents a fan with DC brushless motor used to circulate air in the combustion chamber of a solid-fuel furnace. A way of constructing the permanent magnet motor using much less steel and copper than present motors has been shown. Thanks to the use of sensorless control, the control system of the motor is simple and allows for continuous speed control. It consumes much less energy than previous designs. The motor and control system can be applied in other fans.
PL
W pracy pokazano wentylator z bezszczotkowym silnikiem prądu stałego przeznaczony do nadmuchu powietrza do komory spalania w piecu na paliwa stałe. Pokazano konstrukcję silnika z magnesami trwałymi, na który zużyto znacznie mniej żelaza i miedzi w porównaniu z silnikiem dotychczas stosowanym. Dzięki zastosowaniu sterowania bezczujnikowego układ sterowania silnika jest prosty i umożliwia płynną regulację prędkości obrotowej. Nowy wentylator zużywa znacznie mniej energii niż wentylatory stosowane dotychczas. Taki silnik i układ sterowania może być stosowany w wentylatorach o innym przeznaczeniu.
14
Content available Wentylator do pieca na paliwa stałe
PL
W pracy przedstawiono wentylator z bezszczotkowym silnikiem prądu stałego przeznaczony do nadmuchu powietrza do komory spalania w piecu na paliwa stałe. Pokazano konstrukcję silnika z magnesami trwałymi, na który zużyto znacznie mniej żelaza i miedzi w porównaniu z silnikiem dotychczas stosowanym. Dzięki zastosowaniu sterowania bezczujnikowego układ sterowania silnika jest prosty i umożliwia płynną regulację prędkości obrotowej. Nowy wentylator zużywa znacznie mniej energii niż wentylatory stosowane dotychczas. Taki silnik i układ sterowania może być stosowany także w wentylatorach o innym przeznaczeniu.
EN
The paper presents the fan with DC brushless motor used to circulate an air in the combustion chamber of the furnace. The construction of the permanent magnet motor having much less of the steel and copper than present motors has been shown. The new motor allows for continuous speed control and consumes much less energy. It can be applied in other fans.
15
EN
The presented investigations are continuation of earlier researches performed in the Institute of Turbomachinery (Lodz University of Technology, Poland). The main aim of this paper is to investigate the acoustics properties of the chosen configuration of a flow set–up consisting of two coaxial counter–rotating rotors. Description and analysis of measurements are presented. As a consequence, conclusions about possibility of noise reduction of such a system are presented. According to the EU Directives, the main areas of application are multi–purpose helicopters with two coaxial counter–rotating rotors, drones and future passenger–aircrafts with next–generation aeroengines.
PL
W artykule opisano wpływ wybranych parametrów na opory przepływu powietrza podczas kompostowania oraz związane z tym zagadnienie projektowania instalacji napowietrzającej. Omówiono kwestię doboru parametrów hydraulicznych wentylatora wymuszającego przepływ powietrza przez warstwę kompostu. Dobierając wentylator należy wziąć pod uwagę maksymalną wydajność urządzenia oraz jednostkowe straty ciśnienia, które zależą od oporów przepływu powietrza przez bioreaktor. Wydajność wentylatora zależy bezpośrednio od zapotrzebowania biomasy na tlen, które w zależności od czasu trwania procesu może zmieniać się w zakresie od 2,6÷52,0 mg O2 · g-1 s.o. · h-1. W konsekwencji, zmianą powinien również podlegać wydatek wentylatora, dopasowany do aktualnego zapotrzebowania tlenu. Analizę współpracy wentylatora z instalacją przeprowadzono pod kątem wpływu wybranych parametrów procesowych, tj.: obciążenia hydraulicznego, wilgotności i porowatości złoża, które w największym stopniu oddziaływują na straty ciśnienia podczas przepływu powietrza przez warstwę kompostu.
EN
The article describes the influence of selected parameters on the air flow resistance during composting and the related issue of aeration system design. The issue of selection of the hydraulic parameters of the fan forcing air flow through the layer of compost was discussed. Choosing the fan should consider maximum efficiency and pressure loss which depend on the resistance of air flow through the bioreactor. The fan efficiency is directly dependent on the biomass oxygen demand which depending on the duration of the process and can vary in the range of 2.6÷52.0 mg O2 · g-1 o.m. · h-1. Consequently, the change should also be subject to expense fan, tailored to the current needs oxygen. The analysis of co-operation with the fan installation was carried out in terms of the influence of selected process parameters, such as: hydraulic load, humidity and porosity of the compost. This parameters have the greatest effect on the pressure loss during air flow through the layer of compost.
17
Content available Energy- saving fan
EN
The paper presents a fan with DC brushless motor used to circulate air in the combustion chamber of a solid-fuel furnace. A way of constructing the permanent magnet motor using much less steel and copper than present motors has been shown. Thanks to the use of sensorless control, the control system of the motor is simple and allows continuous speed control. The fan with a new motor consumes much less energy than the one with three-phase asynchronous motor. The motor and control system can be applied in other fans.
PL
W pracy pokazano nowy napęd z bezszczotkowym silnikiem prądu stałego przeznaczony do wentylatora używanego w nadmuchu powietrza w ekstruderze do produkcji butelek PET. W dotychczas stosowanych w tych urządzeniach wentylatorach używano trójfazowych silników asynchronicznych małej mocy. Ze względu na dużą liczbę używanych wentylatorów – do 40 sztuk w jednym ekstruderze, pobór energii przez wentylatory jest znaczny. Z tego względu zdecydowano się na opracowanie nowej konstrukcji napędu wentylatora o zmniejszonym poborze energii. Opracowany napęd składa się z bezszczotkowego silnika prądu stałego oraz z energoelektronicznego układu sterowania pracą silnika. W artykule pokazano konstrukcję silnika z magnesami trwałymi, na który zużyto znacznie mniej żelaza i miedzi w porównaniu z silnikiem dotychczas stosowanym. W silniku nie ma czujników położenia wirnika i dlatego w układzie sterowania wykorzystano procedurę określania położenia wirnika na podstawie pomiaru napięcia w punkcie neutralnym uzwojenia. Dzięki zastosowaniu sterowania bezczujnikowego zmniejszono liczbę połączeń układu sterowania z silnikiem. Zastosowanie w układzie sterowania specjalizowanego procesora uprościło ten układ i umożliwiło płynną regulację prędkości obrotowej. Wentylator z nowym układem napędowym zużywa znacznie mniej energii niż wentylator z asynchronicznym silnikiem trójfazowym stosowanym dotychczas. Opracowany silnik i układ sterowania może być również stosowany w wentylatorach o innym przeznaczeniu.
PL
W pracy przedstawiono wyniki badań eksperymentalnych prowadzonych w Katedrze Techniki Cieplnej Politechniki Poznańskiej poświęcone wyznaczeniu sprawności wentylatorów bębnowych małej mocy. Zgodnie z dyrektywą Parlamentu Europejskiego numer 2009/125/WE sprawdzono parametry pracy wentylatorów produkowanych na potrzeby przemysłu. Badania eksperymentalne pozwoliły wyznaczyć sprawność maszyn i porównać ją z wartościami wyznaczonymi zgodnie z dyrektywą unijną. Wyniki badań przedstawiono na wykresach w funkcji strumienia objętości przepływającego powietrza. Charakterystyki obejmują rozkłady ciśnienia całkowitego, mocy elektrycznej pobieranej do napędu oraz sprawności wentylatora. Uzyskane wyniki wskazują na konieczność opracowania nowych wytycznych. Nowe wytyczne powinny dotyczyć sprawności osiągane przez wentylatory o małej mocy nie ujęte rozporządzeniem Parlamentu Europejskiego numer 2009/125/WE.
EN
At work shows the results of experimental studies carried out in the Cathedral of Poznań University of technology Thermal Techniques dedicated to the appointment of fan performance tumble low power. In accordance with the directive of the European Parliament the number of 2009/125/EC verified working parameters of fans produced for industry. Experimental studies have helped determine the efficiency of the machines and compare it with the values laid down in accordance with the EU directive. Test results are shown in the diagrams as a function of flowrate passing air. The characteristics of the pressure distributions include total electricity power charged into the drive and the efficiency of the fan. The results obtained indicate that the development of new guidelines. The new guidelines should concern the efficiency achieved by low power fans not covered by regulation of the European Parliament the number of 2009/125/EC.
Logistyka
|
2015
|
nr 3
3622--3629, CD 1
PL
W artykule przedstawiono regulator rozmyty o podwójnej strukturze oraz metodę sekwencyjnego programowania kwadratowego. Zrealizowano model symulacyjny napędu prądu stałego z rozmytym regulatorem prądu oraz rozmytym regulatorem prędkości. Określono optymalizowane zmienne procesu regulacji, a także ograniczenia i początkowe parametry przebiegów czasowych prądu twornika oraz prędkości kątowej. Dokonano strojenia regulatorów rozmytych przy wykorzystaniu metody sekwencyjnego programowania kwadratowego. Przeprowadzono w warunkach rozruchu badania symulacyjne modelu napędu prądu stałego z układem regulacji zrealizowanym z wykorzystaniem opracowanych regulatorów rozmytych. Zaprezentowano wyniki badań symulacyjnych w postaci charakterystyk czasowych prądu twornika, prędkości kątowej oraz całkowego wskaźnika jakości.
EN
The paper presents the fuzzy controller of dual structure and the sequential quadratic programming method. A simulation model of a direct current drive with a fuzzy current controller and a fuzzy speed controller was constructed. The optimized variables of the control process were determined, as well as constraints and initial parameters of the time characteristics of the armature current and the angular speed. The fuzzy controllers were tuned by means of the sequential quadratic programming method. The simulation experiments on the model of a direct current drive with the fuzzy controllers were conducted under the start-up conditions. The results of simulations are presented in the form of time characteristics of the armature current, of the angular speed and the integral quality indicator.
PL
Ze względu na specyficzne warunki pracy maszyn i urządzeń stosowanych w górnictwie węglowym istotny jest sposób ich doboru oraz eksploatacji, który uwzględnia zmieniające się w trakcie pracy warunki. Przedstawiony został proces remontowy wentylatora głównego do przewietrzania wyrobisk kopalnianych i zastosowane w tym procesie rozwiązania. Porównano proces remontowy przed wprowadzeniem systemu zarządzania jakością i po jego wprowadzeniu oraz wskazano na efekty, jakie przyniosło przedsiębiorstwu wprowadzenie tego systemu.
EN
Due to the specific conditions of operating the machines and de vices used in coal mining, the method of their selection and utilisation which takes these conditions into account is important. In this article the renovation process of the main fan used to ventilate excavation sites as well as the solutions used in that process have been shown. We have compared the renovation process before and after the implementation of the quality management system, and shown the benefits it brought for the company.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.