Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 94

Liczba wyników na stronie
first rewind previous Strona / 5 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  failures
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 5 next fast forward last
PL
Dokonano zestawienia możliwych uszkodzeń rur i powłok stosowanych w bezwykopowej rehabilitacji przewodów kanalizacyjnych metodą CIPP bazując na metodach brytyjskiej, amerykańskiej, nowozelandzkiej i europejskiej. Zamieszczono opisy 7 awarii rur i powłok rehabilitacyjnych, które wystąpiły w okresie do 3 lat po zakończeniu robót. Dokonano analizy przyczyn wystąpienia tych awarii.
EN
A list of possible damages to pipes and liners used in trenchless rehabilitation of sewers using the CIPP method was made, based on British, American, New Zealand and European methods. There are descriptions of 7 failures of pipes and rehabilitation liners that occurred within 3 years after the completion of works. An analysis of the causes of the occurrence these failures was made.
PL
Nadkrytyczne kotły fluidalne stanowią przykład nowoczesnego rozwiązania inżynierskiego wykorzystującego paleniska atmosferyczne ze złożem cyrkulacyjnym. Ich zaletą jest przede wszystkim wysoka sprawność spalania węgla (około 98%) i niska emisja zanieczyszczeń do środowiska, w tym tlenków azotu i tlenków siarki. Obecnie w Polsce i na świecie pracuje ponad kilkaset bloków energetycznych, dla których źródłem pary jest kocioł o tej właśnie konstrukcji. W artykule przedstawiono problemy eksploatacyjne nadkrytycznego bloku energetycznego z kotłem fluidalnym CFB 1300 w latach 2017-2020. Wskazano elementy instalacji szczególnie narażone na intensywne niszczenie i uszkodzenia.
EN
Supercritical fluidized bed boilers are an example of a modern engineering solution using atmospheric furnaces with a circulating bed. Their advantage is primarily high coal combustion efficiency (approximately 98%) and low emissions of pollutants into the environment, including nitrogen oxides and sulfur oxides. Currently, there are over several hundred power units operating in Poland and around the world, for which the steam source is a boiler of this particular design. The paper presents operational problems of a supercritical power unit with a CFB 1300 fluidized bed boiler in the period 2017-2020. The elements of the installation that are particularly vulnerable to intensive destruction and damage have been indicated.
EN
Nowadays, additive manufacturing (AM) has surpassed traditional machining in the realm of emerging manufacturing. In the case of conventional machining, where the material is removed by different processes (subtractive manufacturing), there is a possibility of warping and internal stress development. Rapid prototyping is another option to avoid all the drawbacks of conventional machining in terms of manufacturing cost, time, accuracy, and quality. Rapid prototyping of a product by adding material (additive manufacturing) is gaining commercial traction. Additive manufacturing is frequently employed for the fabrication and bulk customization of all kinds of intricate geometrical designs those are absurd by traditional manufacturing techniques. Additive manufacturing techniques are broadly divided into four categories: (a) material extrusion, (b) chain polymerization, (c) laser or electron beam assisted sintering, and (d) direct writing-based processes. This article is a cutting-edge review that focuses on additive manufacturing processes and materials used in additive manufacturing. The process parameters for experimentation are chosen based on the application for which the part is designed. Some input process factors influence others for a specific response, and these critical process parameters are identified and optimized. This paper also gives a synopsis of failures associated with some additive manufacturing methods and their preventive actions.
EN
Objectives: The purpose of this article is to show the Western European judgmental failures towards Russia by perceiving it through European values. These failures have a negative impact on European security and all of them appeared because Russia was considered the European state and the European values were put in Russia. In fact, the Russian Federation is only a geographic part of Europe, but no longer a part of European civilization. Methods: The research was conducted by analyzing the relationship between Western European countries and the Russian Federation, as well as analyzing the general condition of Russian society and Russian foreign policy. Results: This article states that Western European countries made a critical mistake by adopting European values to the Russian Federation. This hypothesis was composed by addressing the following question: What is the grand strategy of the Russian Federation? What are judgmental failures and what are their types? What judgmental failures were made by Western Europe towards Russia? Conclusions: The Russian Federation for the past years has been treated by the Western European states as a strategic business partner, however as it can be seen now, this approach was misleading and was a complete failure in terms of European security. Countries such as France and Germany had not seen Russia as an enemy of the West.
5
Content available remote Stany awaryjne zabytkowych więźb dachowych
PL
W artykule opisano przykłady awarii i katastrof więźb dachowych zabytkowych budynków, których przyczyną była korozja biologiczna wywołana przez zalewanie wodami opadowymi migrującymi przez nieszczelności pokrycia dachu.
EN
The article describes examples of failures and collapses of historic buildings rafter framing, the cause of which was biological corrosion caused by flooding with rainwater migrating through leaks in the roof covering.
6
Content available remote Uszkodzenia i awarie rur GRP
PL
Zestawiono najczęściej popełniane błędy na etapie instalowania rur GRP podając jednocześnie możliwe ich przyczyny oraz sposoby ich unikania. Zamieszczono przykład dotyczący możliwych uszkodzeń tych rur w oparciu o ich badanie techniką CCTV w jednym z polskich miast. Badania te zostały wykonane w dwu okresach, bezpośrednio po odbiorze i 14 miesięcy później. Inwestycja ta obejmowała odcinki przewodu kanalizacyjnego o średnicach 300 i 400 mm. Zamieszczono 7 zdjęć ilustrujących zaobserwowane uszkodzenia. Podano także inne przykłady awarii rur GRP, które stwierdzono zarówno w kraju, jak i za granicą.
EN
The paper presents the most common errors made at the stage of installing pipes, together with possible causes of these errors and the ways of avoiding them. An example of possible damage to GRP pipes, which were examined using the CCTV technique, is provided. Tests were performed in one Polish city and covered two stages, immediately after the pipes were commissioned, and then again 14 months later. The investment covered sections of sewers that had a diameter of 300 mm and 400 mm. The observed damage is shown in 7 photos. Other examples of GRP pipe failures, from both Poland and abroad, are also provided in the paper.
7
Content available remote Propozycja metody diagnostycznej dla sieci wodociągowej
PL
W artykule zaprezentowano koncepcję oraz efekty 3-miesięcznego wdrożenia autorskiej metody detekcji stanów anormalnych w rzeczywistym wodociągu. Długość przewodów rozpatrywanego wodociągu wynosi ok. 260 km. Wydzielono w nim 24 strefy ciśnienia. Wodociąg zawiera jedno ujęcie, 7 zbiorników sieciowych oraz 15 pompowni strefowych. Istotą prezentowanej metody jest integracja modelu numerycznego (opracowanego w programie WaterGems) oraz funkcjonującego monitoringu wykorzystującego system SCADA. Dane pozyskane z monitoringu są na bieżąco porównywane z wynikami symulacji. W przypadku gdy różnice pomiarów i obliczeń symulacyjnych przekraczają założone wartości graniczne generowany jest alarm powiadamiający dyspozytora. Dzięki temu rozwiązaniu dyspozytor nie musi stale śledzić wskazań wszystkich zainstalowanych czujników monitoringu. Dodatkowo wdrożona metoda diagnostyczna pozwala na ocenę wielkości wycieków.
EN
The aim of this paper is to present the detecting abnormal conditions system, including its concepts and effects after 3-month period operation. The analysed water supply system, of total pipe length equal to approx. 260 km, consists of 24 pressure zones, 7 water tanks and 15 water pumping stations. The essence of the system is the integration of numerical model (developed in Bentley WaterGems software) and SCADA monitoring system. The monitoring data are constantly compared to simulation results and when accepted compliance limits are exceeded the appropriate alerts are generated. Such solution cause that the WSS operator does not need to analyse SCADA system indications constantly. The additional application of the system enables the detection of water leakages.
8
Content available remote Analiza przyczyn awarii kanałowej sieci ciepłowniczej w okresie przejściowym
PL
W artykule dokonano analizy przyczyn awarii kanałowych sieci ciepłowniczych, zwłaszcza w okresie przejściowym. Omówiono siły działające na rurociągi ułożone w sieci kanałowej, podano wzory na wydłużenia termiczne i naprężenia w ściankach rur. Scharakteryzowano materiały, z których wykonywane są rury przewodowe. Zasygnalizowano możliwość wystąpienia zjawisk korozji w sieciach ciepłowniczych. Omówiono przyczyny pulsacji ciśnienia i hałasów w sieciach. Na tej podstawie przedstawiono uproszczony opis przyczyn awarii sieci - zwłaszcza w wiosennym okresie przejściowym.
EN
In the article, materials used for district heating carrier pipes and corrosion phenomena are characterized. Causes of pressure pulsations and noise in pipe networks are described. In conclusion, a simplified description of pipeline failure causes (mainly in the transition spring time) is presented.
PL
Analizowane przedsiębiorstwo ZPWiK eksploatowało w 2017 r. sieć wodociągową o długości 486,3 km wykonaną głównie, bo w 76,3% z PEHD i aż 85% stanowią sieci o wieku do 20 lat. Większość awarii w sieci wodociągowej spowodowana jest korozją przewodów rur stalowych i pracami budowlanymi. Z badań wynika, że w ostatnich latach awaryjność ulegała systematycznemu obniżeniu i tak z 2,33 awarii/km rok w 2012 do 1,76 awarii/km rok w 2017 roku. Większość awarii jest usuwana w czasie do 8 godzin, ale można zaobserwować, że od 2015 roku sukcesywnie rośnie liczba trudniejszych awarii usuwanych w czasie dłuższym niż 13 godzin. Mimo dużej awaryjności poziom strat jest stosunkowo niski i ulega obniżeniu z 11,36% w 2012 do 8,75% w 2017 roku, co w porównaniu z danymi Izby Gospodarczej Wodociągi Polskie (IGWP) jest wynikiem bardzo dobrym. Uzyskiwane dobre efekty mają związek z odnową materiałów sieci, z zakupem i wykorzystaniem nowego sprzętu do lokalizowania i usuwania awarii oraz ciągłym rozbudowywanym i analizowanym monitoringiem pracy, jak również redukcją ciśnienia w analizowanej sieci wodociągowej.
EN
In 2017, the analyzed ZPWiK company operated a 486.3 km-long water supply network made mainly of PEHD (76.3%) and 85% of networks up to 20 years old. Most of the failures in the water supply system are due to corrosion of steel pipes and construction work. In recent years, the research shows the failure rate of systemic lowering, and so from 2.33 failure / km year in 2012 to 1.76 failure / km year in 2017 failure / km year. Most failures are removed within 8 hours, but you can see that since 2015 the number of difficult failures to be removed in more than 13 hours has been on a yearly basis increasing. Despite the high failure rate, the level of losses is relatively low and decreases from 11.36% in 2012 to 8.75% in 2017, which, compared to the data of the Polish Waterworks Chamber of Commerce (IGWP), is a very good result. The good results obtained are related to the renewal of network materials, the purchase and use of new equipment for locating and removing failures, and the continuous expanded and analyzed monitoring of work as well as the reduction of pressure in the analyzed water supply network.
EN
Farm tractors due to the nature of their work are exposed to a substantial risk of failures. The issues of their reliability are unusually significant in the aspect of the time limit of realisation of agricultural works in agrotechnical seasons. Nowadays, tractors provided for agriculture have increasingly complex functional units. The aim of the paper was to analyse reliability of presently produced farm tractors. Three tractor makes were evaluated and the analysis of failures was carried out with regard to functional units. Based on the obtained results, the average time of correct functioning and refreshment times and availability of particular tractor makes were determined. It was stated that the obtained empirical data of the correct functioning time and refreshment time may be well described with exponential functions. Significant differences in the values that determine the average time of correct functioning and duration time of refreshment obtained by tractors of the investigated makes were found. From among particular functional units, electric and hydraulic systems were the most often damaged, regardless the tractor make.
PL
Ciągniki rolnicze ze względu na charakter pracy narażone są na duże ryzyko wystąpienia uszkodzeń. Zagadnienie ich niezawodności jest niezwykle istotne w aspekcie terminowości realizacji prac rolniczych w sezonach agrotechnicznych. Współcześnie dostarczane do rolnictwa ciągniki charakteryzują się coraz większą złożonością zespołów funkcjonalnych. Celem pracy była analiza niezawodności obecnie produkowanych ciągników rolniczych. Ocenie poddano 3 marki ciągników, zaś analizę uszkodzeń przeprowadzono na poziomie zespołów funkcjonalnych. Na podstawie uzyskanych wyników wyznaczono średnie czasy poprawnego funkcjonowania i czasy odnowy oraz dyspozycyjność poszczególnych marek ciągników. Stwierdzono, że uzyskane dane empiryczne czasu poprawnego funkcjonowania oraz czasu odnowy mogą być dobrze opisane funkcjami wykładniczymi. Stwierdzono istotne różnice w wartościach określających średnie czasu poprawnego funkcjonowania oraz czasy trwania odnowy uzyskane przez ciągniki badanych marek. Spośród wyszczególnionych zespołów funkcjonalnych najczęstszym uszkodzeniom ulegały układy elektryczny i hydrauliczny, niezależnie od marki ciągnika.
PL
Magnetyczne systemy diagnostyczne stosowane są do oceny stanu technicznego taśm przenośnikowych od początku lat 70. ubiegłego wieku. Początkowo generowały one sygnał analogowy agregowany dla torów pomiarowych (pasów taśmy) o szerokości kilkudziesięciu centymetrów, skanowanych sekwencyjnie jedną głowicą pomiarową w kilku cyklach lub całą szerokością taśmy za jednym razem, dzięki instalacji wielu głowic pomiarowych w całym przekroju. Nie pozwalało to na identyfikację pojedynczych uszkodzeń o wielkości kilku centymetrów. Nowoczesne urządzenia diagnostyczne, dzięki miniaturyzacji, umożliwiają instalację nawet 200 cewek w listwie pomiarowej mocowanej w poprzek pełnej szerokości taśmy, w celu identyfikacji uszkodzeń pojedynczych linek. Zamiast sygnałów analogowych generują one cyfrowy sygnał zerojedynkowy, odpowiadający zmianie znaku pola magnetycznego, co pozwala pokazać uszkodzenie na obrazach 2D. Ułatwia to identyfikację lokalizacji i rozmiaru uszkodzeń w rdzeniu taśmy. Wyniki kilku pomiarów stanu pętli taśmy w jednej z kopalń podziemnych w Polsce posłużyły do opracowania modelu rozwoju uszkodzeń rdzenia taśm przenośnikowych z linkami stalowymi, który powstał w ramach doktoratu obronionego na Wydziale Geoinżynierii, Górnictwa i Geologii PWr przez dr inż. Agatę Kirjanów-Błażej, pod kierunkiem dr. hab. inż. Leszka Jurdziaka. W kolejnych częściach artykułu zostaną przedstawione wyniki analiz statystycznych zebranych danych. Pierwsza część omawia rozkład uszkodzeń wzdłuż osi taśmy. W drugiej przedstawiony zostanie rozkład uszkodzeń w poprzek taśmy, a w trzeciej rozwój uszkodzeń w czasie. Wyniki badań posłużą do opracowania prognozy przyszłych stanów taśmy, co ma praktyczny wymiar dla ich użytkowników. Planuje się zaimplementowanie wykrytych zależności stochastycznych w algorytmach wspomagających podejmowanie decyzji o wymianach taśm w systemie DiagBelt, który opracowany został w ramach grantu NCBiR przez dr. hab. inż. Ryszarda Błażeja.
EN
Magnetic diagnostic systems are used to assess the condition of steel cord conveyor belts since the early 1970s. Initially, they generated an analogue signal aggregated for measuring tracks (belt strips) with a width of several dozen centimetres scanned sequentially by one measuring head in several cycles or the entire belt width at once thanks to the installation of multiple measuring heads throughout the cross-section. Such a solution did not allow identification of individual lesions of a size of a few centimetres. Modern diagnostic devices, thanks to miniaturization, allow the installation of up to 200 coils in a measuring rod mounted across the full width of the belt in order to identify damage to individual cables. Instead of analogue signals, they generate a digital zero-one signal corresponding to the change of the magnetic field sign, which allows showing the damage on 2D images. This solution makes it easier to identify the location and size of damage in the core of the belt. The results of several scans of the belt loop condition in one of the underground mines in Poland were registered. Then they were used to develop a „Model of damage development of the core of steel conveyor belts”, which was work out as a part of the PhD thesis written by Agata Kirjanów-Błażej at the Faculty of Geoengineering, Mining and Geology of the Wroclaw University of Science and Technology supervised by Leszek Jurdziak, university professor. The next parts of the paper will present the results of statistical analyses of collected data. The first discusses the distribution of core failures along the axis of the belt. In the second one, the distribution of defects across the belt will be presented, and in the third, the core failures development over time. The obtained results will be used to develop forecasts of future belt conditions, which has a practical dimension for their users. It is planned to implement the detected stochastic dependencies in algorithms supporting decision making on belt replacements in the DiagBelt system, which was worked out as part of the NCBiR grant by Ryszard Błażej, DSc, PhD.
PL
Drugi artykuł z cyklu poświęconego identyfikacji rozwoju uszkodzeń rdzenia taśm przenośnikowych z linkami stalowymi przy użyciu systemu magnetycznego DiagBelt omawia wyniki badań i analiz rozkładu uszkodzeń rdzenia na przekroju taśmy uzyskane w trakcie trzech kolejnych badań stanu pętli taśm w 2016 roku. Dzięki zmianie sposobu wizualizacji uszkodzeń taśmy z jednowymiarowego sygnału na obraz dwuwymiarowy możliwa stała się rejestracja zmian liczby i wielkości uszkodzeń w czasie. W pierwszym artykule analizowano rozkład uszkodzeń wzdłuż osi taśmy. Obecnie na podstawie trzech kolejnych pomiarów stanu rdzenia czterech odcinków taśm zrealizowanych w marcu, wrześniu i grudniu 2016 przedstawiono histogramy częstości uszkodzeń na przekroju taśmy. Wyznaczono też gęstość liczby uszkodzeń przypadających na 100-metrowy odcinek taśmy dla każdego toru pomiarowego (od 1 do 49), na który przypadało ok. 2,5 cm szerokości taśmy. Wykazano, że uszkodzenia skumulowane są na ok. 40% szerokości taśmy, co przyczynia się do nierównomiernego zużywania się taśmy. W części centralnej gęstość uszkodzeń jest kilkukrotnie wyższa, podobnie jak większe jest tempo ich przyrostów w czasie. Zastosowanie tekstylnego brekera wydłużyło okres użytkowania taśmy do ponad 84 miesięcy. Modyfikacje konstrukcji brekera zwiększające ochronę części centralnej mogłoby dodatkowo zwiększyć trwałość taśm. Dobrano rozkłady normalne opisujące gęstość uszkodzeń na przekroju oraz wyznaczono mnożniki i stałe translacji dopasowujące liczbę uszkodzeń do zarejestrowanych w praktyce. Wykazano, że tempo wzrostu mnożnika rośnie z kwadratem czasu pracy taśmy, a parametry rozkładu normalnego nie ulegają większym zmianom. Podkreślono, że modele symulacyjne korzystające z techniki DEM mogą być weryfikowane poprzez ocenę stanu rdzenia systemem DiagBelt. Wskazano na konieczność dodatkowego pomiaru objętości wytartej taśmy, co wydatnie uzupełniłoby ocenę stanu zużycia taśmy. Jest to istotne z punku widzenia prowadzenia regeneracji taśm. Pokazano, że podobną problematyką zajmują się również inni autorzy.
EN
In the previous issue, the first article from the cycle devoted to the identification of the development of core damages of steel conveyor belts using the DiagBelt magnetic system was published. The change of the method of visualization of the belt failures from one-dimensional signal to a two-dimensional image made it possible to interpret the belt condition quickly and to track the development of the number and size of defects over time. The subject of the first article was the distribution of damages along the axis of the belt. Currently, based on 3 subsequent measurements of the core condition of the four belt sections carried out in March, September and December 2016, the frequency of damage histograms on the cross-section of the belt was presented. Also, the density of the number of failures per 100-meter belt section for each measuring head (from 1 to 49) was estimated, which covers 2.5 cm of belt width. The damage covers approximately 40% of the belt width, which contributes to uneven wear of the belt. In the central part, the density of damage is several times higher, as well as the rate of their growth over time. The use of textile breaker has extended the life of the tape to over 84 months. Modifications of the breaker design increasing the protection of the central part could further increase the durability of the belts. Normal distributions describing the distribution of failures on the cross-section were selected, and multipliers and constant translations correcting the number of failures were selected. The growth rate of the multiplier follows the square of the passing time, and the normal distribution parameters do not change much. It was stipulated that simulation models using DEM technique can be verified by evaluating the core state with the DiagBelt system. It was pointed out the necessity of additional measurement of the volume of the worn belt, which would significantly supplement the assessment of belt wear. It is crucial from the point of view of belt recondition. Other authors also deal with similar issues.
PL
Trzy pierwsze artykuły z cyklu poświęconego identyfikacji rozwoju uszkodzeń rdzenia taśm przenośnikowych typu St w przestrzeni i czasie [1] dotyczą rozkładu uszkodzeń rdzenia taśmy wzdłuż osi [2] i przekroju [3] oraz ocenie tempa przyrostu uszkodzeń w czasie [4]. Wszystkie zacytowane do tej pory prace [1-4] odnosiły się do odcinków taśm. Tym razem autorzy uwagę poświęcili połączeniom odcinków taśm w pętli. Dotychczasowe prace naukowe, poruszające tematykę badań magnetycznych taśm przenośnikowych [5-18], w głównej mierze poświęcono wykrywaniu uszkodzeń i przeprowadzaniu oceny stanu technicznego odcinków taśm. Wielkość i ilość uszkodzeń odcinków ocenia się po wartościach generowanych amplitud, ich zasięgu oraz ilości zmian sygnalizujących uszkodzenia. Wykrycie ich jest stosunkowo proste, gdyż brak zmian w przebiegu sygnału informuje o niewystępujących zmianach w rdzeniu. Pominięcie tematyki połączeń wynika z małego udziału długości połączeń w stosunku do całkowitej długości taśmy i dlatego może być traktowane jako mniej istotne. Wpływ na to ma też większa trudność w automatyzacji analizy sygnałów. Zmiany pola magnetycznego, spowodowane obecnością połączeń, są podobne do sygnałów generowanych przez przeciętą linkę. Nie mogą być jednak traktowane jako uszkodzenie, gdyż regularność zmian wskazuje na celowe działanie, istotne jest rozpoznanie charakteru przebiegu tych sygnałów, które wspomogą przeprowadzenie oceny stanu technicznego połączeń. W rozprawie doktorskiej dr. inż. Tomasza Kozłowskiego [19] opisano metody wyznaczania parametrów, które charakteryzują połączenia taśm przenośnikowych na podstawie analogowych sygnałów magnetycznych. Dane pochodziły z systemu HRDS (High Resolution Diagnostic System), wdrożonego w 2013 r. w Kopalni Węgla Brunatnego Turów. W niniejszym artykule zaprezentowano sygnały cyfrowe z połączeń, zarejestrowane systemem Diagbelt.
EN
The first three articles from the cycle dedicated to identifying the development of St-type conveyor belt core damage in space and time [1] were devoted to the distribution of belt core damage along the axis [2], cross-section [3] and the assessment of the rate of damage growth over time [4]. All the articles cited so far [1-4] concerned belt sections. In this article, the authors devoted attention to the splices in the belt loop. The current scientific works on the subject of magnetic conveyor belt research [5-18] have been mainly devoted to the detection of damages and assessment of the technical condition of belt sections. The amount and quantity of segment damage are assessed by the values of generated amplitudes, their range and the number of changes signaling damage. Detection of them is relatively simple because of the lack of changes In the signal waveform indicates that there are no changes in the core. Splices subject omission results from the small share of the length of connections concerning the total length of the tape and therefore can be treated as less important. This is also influenced by the greater difficulty in automating signal analysis. The changes in the magnetic field caused by the presence of splices are similar to the signals generated by the cut cable. However, they cannot be regarded as damage, as regularity of signal changes indicates deliberate action. It is important to recognize the nature of these signals, which will help assess the condition of the connections. In the doctoral dissertation of Tomasz Kozłowski [19] describes methods of determining parameters that characterize the conveyor belt splices based on analog magnetic signals. The data obtained from the HRDS (High Resolution Diagnostic System) system implemented in 2013 at the Polish lignite mine KWB Turów. This article presents digital signals from splices registered with the DiagBelt system.
PL
Dwa pierwsze artykuły z cyklu poświęconego identyfikacji rozwoju uszkodzeń rdzenia taśm przenośnikowych typu St w przestrzeni i czasie [1] poświęcone były rozkładowi uszkodzeń na powierzchni taśmy wzdłuż osi taśmy [2] oraz na jej przekroju [3]. Trzecia część przedstawia zmiany rozkładu tych uszkodzeń w czasie. Okazało się, że przyrost uszkodzeń w kierunku poprzecznym do osi taśmy jest większy w czasie niż wzdłuż stalowych linek, kierunku migracji wody i rozwoju korozji [4]. Jest to kluczowe odkrycie dla praktyki serwisowania taśm. W artykule wprowadzono skwantyfikowane miary oceny stanu rdzenia odcinków taśm oraz kluczowe wskaźniki stanu. Należą do nich: gęstość uszkodzeń GU, gęstość powierzchni uszkodzeń GPoU oraz średnia powierzchnia uszkodzenia. Pozwalają one na szybką globalną ocenę stanu całej pętli, ocenę poszczególnych odcinków taśmy, tworzących pętlę, jak i ocenę lokalną stanu fragmentu taśmy. Przedstawiono regresję wprowadzonych kluczowych wskaźników oceny stanu względem czasu pracy taśm od momentu jej instalacji: GU(t), GPoU(t) oraz SrPoU(t). Badania statystyczne przeprowadzono dla 30 odcinków 14 pomiarów wykonanych w 60, 66 i 75 oraz 84 miesiącu ich pracy oraz punktu początkowego (t=0). Wszystkie odcinki mają podobną długość i pracują w pętli od momentu jej instalacji. Nowa taśma nie ma żadnych uszkodzeń, więc wszystkie wskaźniki również mają początek w zerze. Miary te nie są zależne od długości odcinków w pętli, która często bywa zmienna [5]. Istotną zaletą tych wskaźników jest możliwość ich automatycznego wyznaczenia przez oprogramowanie systemu DiagBelt. Podstawą do oceny stanu taśmy jest szereg skanów pętli taśm wykonana listwą pomiarową systemu DiagBelt. Statystyki wskaźników stanu taśmy niosą wiele informacji o stopniu zużycia taśmy. Wraz z funkcjami regresji w czasie mogą być wykorzystane do prognozowania pozostałego czasu pracy taśm, z wykorzystaniem korekt tempa zużycia taśm. Procedura określania tej miary ważnej dla użytkowników zostanie przedstawiona w czwartym artykule z serii. Dzięki znajomości tempa zużycia taśmy możliwe będzie prognozowanie zapotrzebowania na taśmy w kopalni.
EN
The first two papers from the cycle devoted to identifying the development of failures to the steel cord conveyor belts in space and time [1] were dedicated to the failures distribution on the belt surface along the belt axis [2] and its cross-section [3]. The third part presents changes in failures development over time. It turned out that the increase in the size of the damage in the transverse direction to the belt axis is more significant with time than along the steel cables, in the course of water migration and corrosion development [4]. This is a crucial discovery for belt maintenance practice. Quantified measures of the belt core condition evaluation and key belt core condition indicators are introduced. Among them are failures density GU, failures area density GPoU, and the average area of damage SrPoU. They allow on a quick assessment of the entire loop globally, individual belt sections forming loops as well as to the evaluation of the condition of the belt fragment locally. The regression of the introduced indicators in relation to the belt operating time from the moment of belt sections installation: GU(t), GPoU (t) and SrPoU(t) are presented. Statistical tests were carried out for 30 sections for four measurements carried out in 60, 66 and 75 and 84 months of the beginning of their work plus the starting point (t = 0). All belt sections have similar length and operate in the loop from the moment of its installation. The new belt has no damage, so all indicators also start from zero. These measures are not dependent on the length of the belt segments in the loop, which is frequently variable [5]. The possibility of their automatic determination by the DiagBelt system software is an important advantage of these indicators. The basis for belt condition assessments is a series of belt loop scans done by the DiagBelt measuring rod. The statistics of belt condition indicators carry a lot of information about the belt wear degree. Together with their regression over time can be used to forecast the remaining life of the belt, taking into account corrections of the belt wear rate. The procedure for determining this measure important for users will appear in the 4th paper of the series| It is possible to forecast the belt demand in the mine due to the knowledge of belt wear rate.
15
Content available Błędy realizacyjne i awaria sufitu podwieszanego
PL
Celem artykułu jest analiza przyczyn zarwania części sufitu podwieszanego. Przeprowadzono badania niszczące metalowych łączników rozporowych. Obliczono ich dopuszczalne obciążenia – admF, zgodnie z normą PN/EN 13964:2014 oraz skonfrontowano stan rzeczywisty konstrukcji z „ogólnym” schematem sufitu, którym dysponował wykonawca. Pomimo że łączniki rozporowe spełniały warunek nośności, m.in. niejednakowe obciążenia wieszaków i przekroczenia ich max rozstawów (nawet o 70%) oraz za długi wspornik (6-krotnie) względem przewidzianych w systemie spowodowały awarię konstrukcji.
EN
. This article aims to analyze the causes of failure of part of the suspended ceiling. The destructive tests of metal expansion plugs have been carried out. Their admissible loads were calculated – adm F, in accordance with PN/EN 13964:2014, and the actual state of the structure was confronted with the “general” ceiling scheme that the contractor had at its disposal. Although the expansion plugs met the load capacity condition, uneven load of hangers and exceeding their maximum spacing (up to 70%) and a long bracket (6 times) in relation to those provided in the system caused a structural failure.
EN
In 2017, the analysed enterprise ZPWiK (Zabrzańskie Enterprise of Water Supply Network and Sewage System) operated the water supply network of 486.3 km length, constructed mainly (in 76.3%) from PE-DH ( polyethylene of high density). The age of as much as 85% of the network is up to 20 years old. The most of failures in water supply network is caused by a corrosion of steel pipelines and the conducted constructional work. It is followed from the studies that the failure frequency is systematically decreasing: from 2.33 failures/km in 2012, to 1.76 failures /km in 2017. The majority of the occurring failures are removed during up to 8 hours but we may observe that since 2015, the number of more difficult failures, being removed during longer period than 13 hours, has been successively increased. In spite of a high failure frequency, the level of losses is relatively low and is decreased from 11.36% in 2012 to 8.75% in 2017, what in comparison to the data of IGWP (Economic Chamber “Polish Water Supply Network”) is a very good result. The obtained good effects are connected with the renewal of the network materials, purchase and utilization of new equipment for finding out and recovery of the failures and constantly developed and analysed monitoring of work as well as the pressure reduction in the water supply network.
PL
Analizowane przedsiębiorstwo ZPWiK eksploatowało w 2017 sieć wodociągową o długości 486,3 km wykonaną głownie bo w 76,3% z PEHD i aż 85% stanowią sieci o wieku do 20 lat. Większość awarii w sieci wodociągowej spowodowana jest korozją przewodów rur stalowych i pracami budowlanymi. Z badań wynika że awaryjność ulega systematycznemu obniżeniu z 2,33 w 2012 do 1,76 w 2017 awarii/km rok. Większość awarii jest usuwana w czasie do 8 godzin, ale można zaobserwować że od 2015 roku sukcesywnie rośnie liczba trudniejszych awarii usuwanych w czasie dłuższym niż 13 godzin. Mino dużej awaryjności poziom strat jest stosunkowo niski i ulega obniżeniu z 11,36% w 2012 do 8,75% w 2017, co w porównaniu z danymi IGWP jest wynikiem bardzo dobrym. Uzyskiwane dobre efekty mają związek z odnową materiałów sieci, z zakupem i wykorzystaniem nowego sprzętu do lokalizowania i usuwania awarii oraz ciągłym rozbudowywanym i analizowanym monitoringiem pracy jak również redukcji ciśnienia w sieci wodociągowej.
17
Content available Equipment/machinery failure rate in hard coal mines
EN
The main task of the maintenance services in hard coal mines is to ensure continuous operation of the equipment (machines). The measurable effect of these actions should be the reduction of maintenance costs of equipment (machinery) and thus the reduction of production costs - coal mining. The paper presents an issue of failure rate of technical measures applied in the mining process. In order to ensure greater efficiency and productivity, it is necessary to find the causes of the most frequent failures in this process and effectively counteract them. As a result of these activities, the production availability of machines/equipment involved in the mining process will increase. This will to a large extent ensure failure-free and uninterrupted progress, increase productivity and improve the quality of manufactured products, as well as reduce the operating costs of equipment (machines), and thus reduce production and product costs. This effect should consist mainly in the control of rational, safe and effective use and operation of equipment (machines) in the exploitation process. An algorithm implemented in one of the hard coal mines was presented. The technical condition of underground mining equipment was observed by periodical measurements of vibration parameters at selected points on the machine - measurements were conducted with a vibration pen. The aim of this research is to improve the reliability of technological process of a mining plant through its failure-free operation. In order to achieve this objective, i.e. the efficiency of a mining company, it is necessary to reduce its costs. The action that leads to this aim is a proper assessment of the technical condition with regard to the equipment used in technological process.
18
Content available Dławiki w filtrach kompensacyjnych pasywnych
PL
Filtry pasywne wyższych harmonicznych są stosowane w sieciach elektroenergetycznych, do których są przyłączone nieliniowe odbiorniki energii elektrycznej dużej mocy. Filtr pasywny jest układem szeregowym indukcyjności L i pojemności C, tak dobranych, aby dla pulsacji ωv były w rezonansie. Pojedynczy filtr składa się z dławika indukcyjnego i baterii kondensatorów. Zarówno dławiki, jak i kondensatory powinny mieć znamionową moc pozorną dopasowaną do mocy harmonicznej, którą kompensują. Jeśli moc filtru jest za mała, to istnieje zagrożenie przegrzania termicznego dławika bądź baterii kondensatorów. Rdzenie magnetyczne dławików są dzielone tak, aby w obwodzie magnetycznym było kilka szczelin powietrznych. Segmenty rdzeni w zmiennym polu magnetycznym drgają. Drgania te przy słabym zamocowaniu rdzenia prowadzą do uszkodzenia mocowania i uszkodzenia uzwojenia. Załączono zdjęcia dławika z przegrzanym uzwojeniem i uszkodzonym mocowaniem rdzenia.
EN
Harmonic passive filters are used in power networks to which non-linear high-power electric energy receivers are connected. Passive filter is built as a series connection of inductance L and capacitance C, calculated for resonance at ων. A single filter consists of an induction choke and a capacitor bank. Both, chokes and capacitors, should have a nominal apparent power adjusted to the harmonic power they compensate. If the filter power is too low, there is a risk of overheating of the chock or capacitor bank. The magnetic cores of the chocks are divided so that there are several air gaps in the magnetic circuit. Segments of cores in a variable magnetic field vibrate. These vibrations lead to damage of the mounting and damage of the winding, when the core is not poorly installed. Photos of the chock with overheated winding and damaged core are attached.
19
Content available Dławiki w filtrach kompensacyjnych pasywnych
PL
Filtry pasywne wyższych harmonicznych są stosowane w sieciach elektroenergetycznych, do których są przyłączone nieliniowe odbiorniki energii elektrycznej dużej mocy. Filtr pasywny jest układem szeregowym indukcyjności L i pojemności C , tak dobranych, aby dla pulsacji ων były w rezonansie. Pojedynczy filtr składa się z dławika indukcyjnego i baterii kondensatorów. Zarówno dławiki jak i kondensatory powinny mieć znamionową moc pozorną dopasowaną do mocy harmonicznej, którą kompensują. Jeśli moc filtra jest za mała to istnieje zagrożenie przegrzania termicznego dławika bądź baterii kondensatorów. Rdzenie magnetyczne dławików są dzielone tak, aby w obwodzie magnetycznym było kilka szczelin powietrznych. Segmenty rdzeni w zmiennym polu magnetycznym drgają. Drgania te, przy słabym zamocowaniu rdzenia prowadzą do uszkodzenia mocowania i uszkodzenia uzwojenia. Załączono zdjęcia dławika z przegrzanym uzwojeniem i uszkodzonym mocowaniem rdzenia.
EN
Harmonic passive filters are used in power networks to which non-linear high-power electric energy receivers are connected. Passive filter is built as a series connection of inductance L and capacitance C, calculated for resonance at ων. A single filter consists of an induction choke and a capacitor bank. Both, chokes and capacitors, should have a nominal apparent power adjusted to the harmonic power they compensate. If the filter power is too low, there is a risk of overheating of the chock or capacitor bank. The magnetic cores of the chocks are divided so that there are several air gaps in the magnetic circuit. Segments of cores in a variable magnetic field vibrate. These vibrations lead to damage of the mounting and damage of the winding, when the core is not poorly installed. Photos of the chock with overheated winding and damaged core are attached.
PL
Analizowany system dystrybucji wody zaopatruje ponad 155 tys. mieszkańców, a jego długość wynosi 1470 km w tym 27 357 przyłączy wodociągowych. Sieć wodociągowa składa się w ponad 91% z tworzyw sztucznych, a przyłącza w 96% z PE HD. Średnia awaryjność poszczególnych materiałów wykazuje że 64% awarii powstaje na rurach stalowych, 26% na rurach z żeliwa szarego a tylko 4% na rurach z PE. W latach 2011 do 2017 liczba awarii wahała się od 377 do 271 na rok. Wskaźnik uszkodzeń sieci wodociągowej wynosił odpowiednio X = 0,26 - 0,13 uszk./km x rok, co pozwala określić jej stan techniczny jako dobry. Wdrożono GIS i podział sieci wodociągowej na strefy zasilania wraz z monitoringiem, który jest ciągle poprawiany i rozbudowywany, a już przynosi wiele korzyści w codziennej eksploatacji sieci. Obserwując straty wody w kolejnych latach widać sukcesywny spadek tej wartości z 10,72% w 2011 roku do 6,50 % w 2017 roku.
EN
In the analyzed PWiK, the water supply network consists of over 91% of plastics, and connections in 96% of PE HD. One can say that the analyzed network is very modern in respect with national conditions. The average failure rate of individual component shows that up to 64% of failures are generated on steel pipes, 26% on gray iron pipes and only 4% on PE pipes. In 2011-2017, the number of failures varied from 377 to 271 a year. The failure rate of the water supply network was X = 0.26 -0.13 damage/km x a year which allows to determine its technical condition as good. GIS was implemented and the water supply system was divided into supply zones with monitoring, which are constantly improved and extended, and already bring many benefits in the daily operation of the network. Observing water losses in the following years, we can see a gradual decrease in this value from 10.72% in 2011 to 6.5% in 2017.
first rewind previous Strona / 5 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.