Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  electrochemical sensor
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In recent years the monitoring of air quality using cheap sensors has become an interesting alternative to conventional analytical techniques. Apart from vast price differences conventional techniques need to be performed by the trained personnel of commercial or research laboratories. Sensors capable of measuring dust, ozone, nitrogen and sulphur oxides, or other air pollutants are relatively simple electronic devices, which are comparable in size to a mobile phone. They provide the general public with the possibility to monitor air quality which can contribute to various projects that differ in regional scale, commercial funding or community-base. In connection with the low price of sensors arises the question of the quality of measured data. This issue is addressed by a number of studies focused on comparing the sensor data with the data of reference measurements. Sensory measurement is influenced by the monitored analyte, type and design of the particular sensor, as well as by the measurement conditions. Currently sensor networks serve as an additional source of information to the network of air quality monitoring stations, where the density of the network provides concentration trends in the area that may exceed specific measured values of pollutant concentrations and low uncertainty of reference measurements. The constant development of all types of sensors is leading to improvements and the difference in data quality between sensors and conventional monitoring techniques may be reduced.
EN
Recently, transition metal oxides, which exhibit favorable catalytic abilities, have also been investigated as a material for the detection of hydrazine (N2H4). It has been reported that mixed metal oxides usually offer a higher electrochemical activity than binary oxides. In this work, a TiO2-Fe2O3 coupled system is presented as an enhanced material with major applications in electrochemical detectors. The electrochemical behavior of glassy carbon electrodes modified with TiO2-Fe2O3 in the absence and presence of hydrazine was evaluated via cyclic voltammetry (CV). Experimental results also suggest that the formation of the TiO2-Fe2O3 coupled system enhances electrochemical catalytic performance in N2H4 detection. The modificationTiO2+2 mol% Fe2O3 provides good analytical performance of detection (0.13 mM) and quantification limits (0.39 mM). The presented coupled system provides the premise for a suitable material for a stable and sensitive N2H4 sensor.
3
PL
W artykule przedstawiono opis budowy oraz badania modułu czujników wielu gazów substancji chemicznych. Moduł jest w stanie wykrywać 11 różnych substancji w stanie gazowym jednocześnie i liczba ta może zostać zwiększona w miarę potrzeb. Moduł został zaprojektowany i zbudowany jako urządzenie do zainstalowania na mobilnych platformach bezzałogowych w zastosowaniach antykryzysowych.
EN
The paper describes the construction and the results of investigations of the multigas module of chemical contaminants sensors. The module is able to detect 11 different volatile chemical agents simultaneously and this number can be increased if needed. The module was designed and built as a device installed on mobile unmanned platform for anti-crisis application.
EN
Electrochemical sensors for various applications including diagnosis of infectious diseases, detection of chemicals, DNA hybridization and detection of pathogenic micro organisms have been reported in recent years. Real­time monitoring of food and water is a high priority globally and the presence of pathogenic micro organisms is a particular environmental concern. Although various measures like good agricultural practices [1, 2], good manufacturing practices [2. 3], hazard analysis and critical control point (HACCP) [4, 5] and the food code indicating approaches [6], have been taken to monitor the food quality, there are still reports of outbreaks. Detailed in this work is the design of a sensor head for use in a handheld electrochemical analyzer system to detect environmental variables including pathogenic micro-organisms in real-time. A thick-film interdigitated gold electrode (IDE) prepared by screen printing technique was employed as a sensor to detect DNA of the foodbome pathogen Bacillus cereus. Polypyrrole (PPy) was used as an immobilization matrix and the combination of PPy modified interdigitated micro-electrode with impedance measurements yielded a sensitive label-free biosensor which was able to detect DNA. The IDE prepared by thick-film technology is sensitive, rapid and cost effective. The electrical detection of 100 pM concentration of DNA immobilized onto the PPy modified gold IDE was achieved, with an IDE width of 400μm.
PL
W ostatnich latach wiele publikowano na temat przetworników elektrochemicznych do różnych zastosowań, między innymi do diagnostyki chorób zakaźnych, detekcji związków chemicznych, hybrydyzacji DNA i detekcji patogenicznych mikroorganizmów. Monitorowanie żywności i wody w czasie rzeczywistym ma globalnie wysoki priorytet a obecność patogenicznych organizmów jest szczególnie ważnym zagadnieniem w badaniach środowiska. Chociaż zastosowano różne miary do monitorowania jakości żywości, takie jak zasady dobrej praktyki rolniczej [1, 2], zasady dobrej praktyki produkcyjnej [2, 3], system analizy zagrożeń i krytycznych punktów kontroli (HACCP) [4, 5] system kodów do znakowania żywności [6], ciągle pojawiają się raporty o wybuchach epidemii. Przedmiotem pracy jest projekt głowicy czujnika do zastosowania w podręcznym elektrochemicznym analizatorze do detekcji w czasie rzeczywistym zmiennych środowiskowych z uwzględnieniem patogenicznych mikroorganizmów. Cienkowarstwową międzypalczastą złotą elektrodę (IDE), wykonaną techniką sitodruku, zastosowano jako czujnik do detekcji DNA występującego w żywności patogenu Bacillus cereus. Zastosowanie Polypynole (PPy) jako matrycy immobilizującej i połączenie modyfikowanej za pomocą PPy międzypalczastej mikroelektrody z pomiarami impedancji dało czuły biosensor, który jest zdolny do detekcji DNA. Elektroda IDE wykonana w technologii cienkowarstwowej jest czuła, szybka i tania. Uzyskano elektryczną detekcję 100 pM koncentracji DNA immobilizowanego na zmodyfikowanej przez PPy złotej IDE, o szerokości 400μm.
PL
W pracy przedstawiono prototypowy, laboratoryjny, elektrochemiczny czujnik do oznaczania par benzaldehydu w argonie. Cieczą jonową testowaną jako elektrolit i środowisko reakcji redox była: bis(trifluorometylosulfonylo) i midek 1-butylo, 3-metyloimidazolinowy ([BMIM][Tf₂N]). W pomiarach użyto komercyjnych elektrod firm: DropSens Co. i BVT Technologies. Walidacji poddano dwa parametry metrologiczne czujnika: granicę wykrywalności i czułość.
EN
The paper presents a laboratory prototype of an electrochemical sensor for measurements of benzaldehyde vapor in argon. The following ionic liquid was tested as the electrolyte and redox reaction environment: 1-butyl 3-methylimidazolium bis (trifluoromethanesulfonyl)imide ([BMIM][Tf₂N]). The measurements used commercial electrodes company DropSens Co. and BVT Technologies. Two metrological parameters of the sensor have been subjected to validation: limit of detection and sensitivity.
PL
W artykule przedstawiono wyniki pracy polegającej na wykonaniu przenośnego urządzenia do pomiaru śladowych ilości tlenku węgla. W urządzeniu zastosowano wysokiej klasy, elektrochemiczny czujnik do pomiaru tlenku węgla firmy Figaro oraz mikrokontroler sterujący urządzeniem. Urządzenie posiada możliwość kalibracji oraz odczytu wskazań na lokalnym wyświetlaczu LCD. Przeprowadzono badania czujnika oraz urządzenia w celu weryfikacji poprawności jego działania. Oceniona została niepewność pomiarów wykonywana urządzeniem.
EN
The paper presents the construction of a portable device for measuring low concentration of carbon monoxide. The device uses high-end, an Figaro's electrochemical sensor for measuring carbon monoxide and microprocessor control unit. The device allows to calibrate and read values on the local LCD display. Tests of the device and the sensor were performed. Verified proper operation of the device. The uncertainty of measurement device was assessed.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.