EN
In this paper there are presented some results obtained by open circuit potential and electrochemical impedance spectroscopy measurements from studies performed on the behavior of tribocorrosion on metallic implant biomaterials as: 304L stainless steel, Co/nano-CeO2 nanocomposite layer and Ti6Al4V untreated and oxidized alloy to form a nanoporous TiO2 film. The open circuit potential technique used in measuring the tribocorrosion process provide information on the active or passive behavior of the investigated metallic biomaterial in the biological fluid, before, during friction and after stopping the friction. Thus it clearly show a better behavior of Co/nano-CeO2 nanocomposite coatings as compared with 304L stainless steel to tribocorrosion degradation in Hank solution; as well the better behavior of nanoporous TiO2 film formed annodically on Ti6Al4V alloy surface as compared with untreated alloy to tribocorrosion degradation in artificial saliva Fusayama Meyer. The slight decrease in polarization resistance value resulted from electrochemical impedance spectroscopy measured during friction in the case of the Co/nano-CeO2 nanocomposite layer (four times smaller), compared to 304L stainless steel, whose polarization resistance decreased more than 1000 times during friction shows the higher sensitivity of stainless steel to degradation by tribocorrosion. The same behavior is observed when comparing the polarization resistance of untreated titanium alloy recorded during friction that is about 200 hundred times smaller, while the specific polarization resistance of the oxidized alloy with the nanoporous film of titanium oxide, decreases very little during friction, highlighting the beneficial effect of modifying the titanium alloy by anodic oxidation to increase its resistance to the degradation process by tribocorrosion.
EN
Now, the use of any medical device based on metals or alloys, especially intended for dentistry applications, is impossible without preclinical evaluation of its anticorrosion properties. Today, the use of stainless steels with AISI standardization, with predilection 316L and 321, are preferred for ergonomic reasons due to their high operational reliability and optimal mechanical properties for functionality over time. In this regard, 316L and 321 stainless steels are tested for comparison in the solution that simulates human saliva with different pH. Stainless steel samples were subjected to corrosion in Fusayama-Meyer and Carter-Brugirard saliva. In-situ electrochemical measurements were applied, such as the open circuit potential (OCP) and electrochemical impedance spectroscopy (EIS). The results show that the corrosion resistance of 316L is superior to 321 in saliva solution at both pH values.
EN
The aim of this paper was to study the corrosion behavior of Nickel - Base - Dental Alloys in Ringer biological fluid. The Nickel base alloys are widely used for medical purposes, especially for prosthetic works in the field of dentistry. The applied electrochemical methods used for corrosion investigations are Open Circuit Potential, Linear Polarization during time of immersion in order to calculate the polarization resistance and corrosion rate. Potentiodynamic Polarization diagrams was performed to appreciate the passive domain. Ni-Cr Ugirex alloy show a better corrosion resistance in Ringer solution which will be reflected in a longer life of the dental structures made with this alloy as compared to the Ni-Cr Ducinox alloy, which will result in dental structures with a shorter lifespan. The electrochemical studies has shown that the alloy have a corrosion behavior similar to a passivating alloy, displaying an extensive passivity area due to formation of an oxide film.
EN
The article presents the results of the study on the process of copper electroevolution from the regeneration solutions in one- and two-chamber electrolyzers at different concentrations of sulfuric acid and the solutions of copper chlorides at different concentrations of hydrochloric acid – in a three-chamber electrolyzer. The conditions of electrochemical recovery of heavy metals from acidic and saline solutions were determined. It was shown that the most effective recovery of heavy metal cations from hydrochloric acid solutions occurs in three-chamber electrolyzers. On the basis of the results obtained, a technological scheme of a local plant for treatment of washing water of galvanic industries was proposed.
PL
W pracy przedstawiono wpływ powłok wytworzonych w procesie plazmowym PECVD (ang. Plasma Enhanced Chemical Vapour Deposition), z wykorzystaniem plazmy wysokiej częstotliwości (13,56 MHz), na właściwości korozyjne stopu magnezu AZ31 oraz stopu tytanu Ti6Al4V. Na stopie magnezu wykonano powłoki SiO₂ o grubościach 12 nm, 22 nm i 44 nm. Natomiast na stopie tytanu powłokę Si₃N₄ o grubości 400 nm i warstwę hybrydową Si₃N₄/Gr/Si₃N₄/Gr/Si₃N₄/Gr/Si₃N₄/Gr o grubości 200 nm. Właściwości korozyjne badanych powłok określono na podstawie analizy krzywych woltamperometrycznych. Otrzymane wyniki pokazują wzrost odporności korozyjnej badanych stopów w momencie zabezpieczenia ich powierzchni proponowanymi warstwami ochronnymi. W przypadku stopu magnezu, największy spadek wartości gęstości prądu korozji zaobserwowano, dla warstwy SiO₂ o grubości 44 nm a w przypadku stopu tytanu dla warstwy hybrydowej Si₃N₄/Gr/Si₃N₄/Gr/Si₃N₄/Gr/Si₃N₄/Gr o grubości 200 nm.
EN
In this work, the influence of coatings produced in the radio frequency plasma PECVD (Plasma Enhanced Vapor Deposition) on the corrosion properties of magnesium alloy AZ31 and titanium alloy Ti6Al4V, has been reported. At the magnesium alloy surface the silicon dioxide layers with three different thickness: 12 nm, 22 nm and 44nm, was performed. At the titanium alloy surface the silicon nitride layer with the thickness 400 nm and hybrid layer Si₃N₄/Gr/Si₃N₄/Gr/Si₃N₄/Gr/ Si₃N₄/Gr with the thickness 200 nm, were performed. Corrosion properties of investigated coatings was based on analysis of the voltammetric curves. Presented results have shown an increase in corrosion resistance of investigated alloys at the time of protecting their surface with the proposed protective coatings. In the case of magnesium alloy, the largest decrease of corrosion current density was observed for the SiO₂ layer with the thickness 44 nm, and in the case of titanium alloy for the hybrid layer with the thickness 200 nm.
PL
W artykule przedstawiono zasady działania i konstrukcję innowacyjnego samopolaryzującego czujnika elektrochemicznego opartego na komorze Mackeretha do nieinwazyjnego naskórnego pomiaru prężności tlenu w krwi tętniczej. Opisany czujnik przeszedł wstępne pozytywne badania techniczne oraz eksploatacyjno-eksperymentalne i powinien odznaczać się lepszą stabilnością czasową czułości oraz trwałością działania w stosunku do dotychczas stosowanych czujników opartych na metodzie Clarka. Przedstawiony czujnik jest łatwy do zastosowań klinicznych, szczególnie ważnych w monitorowaniu procesu tlenoterapii w komorach hiperbarycznych.
EN
Principle of activation and own design of innovative selfpolarized electrochemical sensor for transcutaneous measuerement of blood oxygen tension, based on Mackereth’s chamber were presented. Preliminary positive technical and experimental studies were performed. The presented sensor should be much better than nowadays transcutaneous blood oxygen sensors based on Clarck method. This sensor is easy to use in clinical application and particularly important for monitoring of oxygen tension during oxygen therapy in hyperbaric chambers.
PL
Zbadano wpływ pH środowiska i obecności białka osocza krwi na właściwości antykorozyjne powłoki ditlenku tytanu TiO2. Powłokę TiO2 o strukturze amorficznej z krystalitami anatazu otrzymywano metodą zol-żel na powierzchni stopu biomedycznego M30NW. Badania korozyjne z wykorzystaniem metod elektrochemicznych przeprowadzono w temperaturze 37°C w roztworze 0.9 % NaCl (sól fizjologiczna) o pH 4.5 oraz 7.4. Wartości pH wybrane do badań pozwoliły przybliżyć 51 warunki naturalnie występujące w środowisku tkankowym (pH=7.4) oraz warunki stanu zapalnego, który może pojawić się w organizmie (pH=4.5). Aby jeszcze lepiej odwzorować środowisko tkankowe, do roztworu soli fizjologicznej dodano albuminę - białko występujące w osoczu krwi w największej ilości. Właściwości antykorozyjne powłoki TiO2 określono w oparciu o wyznaczone wartości potencjału korozyjnego Ecor, oporu polaryzacyjnego Rp, szybkości korozji CR, gęstości prądu w obszarze pasywnym i0.5 oraz potencjałów przebicia Eb i repasywacji Erep. Stwierdzono, że modyfikacja powierzchni stopu M30NW powłoką TiO2 powoduje zwiększenie odporności korozyjnej badanego stopu w roztworach NaCl o pH równym 4.5 i 7.4 - antykorozyjne działanie powłoki TiO2 widoczne jest zarówno w potencjale korozyjnym jak i przy polaryzacji anodowej. Dodatek albuminy ma niejednoznaczny wpływ na antykorozyjne właściwości powłoki TiO2 w potencjale korozyjnym. Natomiast przy polaryzacji anodowej wpływ białka zaznacza się jedynie w roztworze NaCl o pH 4.5 - albumina powoduje istotne zwiększenie potencjału przebicia dla stopu z powłoką TiO2.
EN
In this study we investigated the influence of solution pH and serum protein on the anticorrosion properties of titanium dioxide TiO2 coating. This TiO2 coating with amorphous structure containing crystallites of anatase was obtained by the solgel method on the surface of M30NW biomedical alloy. Corrosion measurements using electrochemical methods were carried out in 0.9 % NaCl (physiological saline) solution at pH of 4.5 and 7.4. The pH values selected for the tests simulate both natural body conditions (pH=7.4) and inflammatory conditions which may occur in the body (pH=4.5). Much better simulation of tissue environment was achieved by adding of albumin – protein found in blood plasma in the greatest amount. Anticorrosion properties of TiO2 coating were determined on the basis of corrosion potential Ecor, polarization resistance Rp, corrosion rate CR, current density in the passive range i0.5 and also breakdown Eb and repasssivation potentials Erep. It was stated that modification of M30NW alloy surface by TiO2 coating cause increase in corrosion resistance of the investigated alloy in NaCl solutions both at pH of 4.5 and 7.4 - anticorrosive effect of TiO2 coating is evident both at corrosion potential and during the anodic polarization. The addition of albumin has an ambiguous effect on the anticorrosion properties of the TiO2 coating at the corrosion potential. Whereas during the anodic polarization the protein effect is visible only in NaCl solution at pH of 4.5 – albumin causes significant increase in the breakdown potential of the alloy coated by TiO2.
PL
W artykule zostały przedstawione elektrochemiczne metody i własnej konstrukcji naskórne czujniki oraz układy elektroniczne do pomiaru prężności tlenu i dwutlenku węgla pO₂ i pCO₂ w krwi tętniczej. Opisano i przedyskutowano wstępne wyniki pomiarów eksperymentalnych pO₂ i pCO₂. Przedstawione czujniki i przyrządy pomiarowe są łatwe do zastosowań klinicznych. Stanowią one ważne narzędzia do monitorowania czynności układu oddechowego i układu krążenia, szczególnie w warunkach intensywnej opieki medycznej, a zwłaszcza w czasie terapii tlenowej w komorach wysokociśnieniowych.
EN
The electrochemical methods and own design of the transcutaneous sensors and electronic instrumentation for measurement of oxygen and tension carbon dioxide (pO₂ and pCO₂) in arterial blood are presented. The preliminary experimental results of pO₂ and pCO₂ measurements are discussed. The presented sensors and instruments are convenient for clinical application. They are very important for monitoring of respiratory and blood circulatory function, particularly in intensive care, anesthesia and during oxygen therapy in hyperbaric chambers.
PL
W pracy przedstawiono wyniki badań wpływu wygrzewania w piecu próżniowym w temperaturach 360°C, 380°C, 400°C, 420°C, 450°C przez okres 330 minut na odporność korozyjną stopu AZ91D. Badania odporności korozyjnej w 0,5M NaCl próbek nie wygrzewanych oraz obrobionych cieplnie przeprowadzono metodami elektrochemicznymi (badania stało- i zmiennoprądowe). Wykonano także badania dyfrakcyjne oraz morfologię powierzchni próbek. Wykazano, że wygrzewanie w piecu próżniowym powoduje zmniejszenie odporności korozyjnej stopu AZ91D.
EN
This paper presents the influence of annealing in a vacuum furnace at temperatures of 360° C, 380° C, 400° C, 420° C, 450° C for 330 minutes on corrosion resistance of AZ91D alloy. The corrosion resistance of the heat treated samples had been investigated in 0.5 M NaCl by the electrochemical methods (research fixed-and variable-current). The surface morphology and diffraction studies of the samples were performed. It was shown that heat treatment in a vacuum decreases the corrosion resistance of the samples made of AZ91D alloy.
PL
W pracy przedstawiono wpływ azotu, wprowadzonego w obszar między powierzchnią stopu magnezu a powłoką SiO2, na właściwości korozyjne stopu magnezu AZ91. Azot wprowadzany był przed procesem wytworzenia warstwyochronnej za pomocą procesu ultra-płytkiej implantacji z plazmy wysokiej częstotliwości (13,56 MHz) w reaktorze PECVD. Do procesu implantacji wykorzystana została plazma wytworzona w gazach: N2 oraz NH3. Następnie, na każdej zaimplantowanej próbce wytworzono powłokę ochronną za pomocą procesu utleniania plazmowego lub osadzania plazmowego. Uzyskane wyniki zestawione zostały z próbką referencyjną badanego stopu. Właściwości korozyjne wytworzonych powłok określono na podstawie analizy krzywych woltamperometrycznych. Najniższe gęstości prądu korozji otrzymano dla próbki, której powłoka ochronna wykonana została w procesie osadzania plazmowego na powierzchni zaimplantowanej z plazmy wytworzonej w gazie N2 (ikor = 2,36 žA/cm2). Największą odporność na występowanie korozji wżerowej (największa różnica potencjałów: potencjału korozyjnego Ekor i potencjału korozji wżerowej Epit) zaobserwowano dla próbki, której powłoka ochronna wytworzona została przez utlenianie plazmowe wykonywane po procesie implantacji azotu z plazmy powstałej w gazie NH3.
EN
The work shows the influence of nitrogen, incorporated at the interface between the surface of magnesium alloy and SiO2 coating, on corrosion resistance of AZ91 magnesium alloys. Nitrogen was incorporated before the process of manufacture of protective layers by using the ultra-shallow implantation process of the high frequency plasma (13,56 MHz) in the reactor PECVD. During implantation process was used two types of plasma: N2 and NH3. Then, on each implanted sample was formed the protective coating by the plasma oxidation process or plasma deposition process. The obtained results have been compared with the reference sample. The corrosion properties of formed coatings was established on the basis of the analysis of the voltammetric curves. The lowest value of corrosion current density was obtained for the sample with coating formed in the plasma deposition process connected with N2 plasma implantation process (ikor = 2,36 žA/cm2). The lowest value of pitting corrosion (the largest difference of potentials: the potential of corrosion-resistant Ekor and potential of pitting corrosion Epit) was observed for samples,which the coating produced by plasma oxidation process connected with NH3 plasma implantation process.
11
Content available remote Wpływ obróbki cieplnej na odporność korozyjną elektrolitycznych powłok Ni-W
PL
W pracy przedstawiono wyniki badań dotyczących oceny odporności korozyjnej powłok Ni-W, elektroosadzanych na podłożu ze stali węglowej metodą galwanostatyczną, przed i po obróbce cieplnej w powietrzu w temp. 900°C. Odporność na korozję elektrochemiczną badano w 5% roztworze NaCl przy zastosowaniu techniki polaryzacji potencjodynamicznej oraz elektrochemicznej spektroskopii impedancji. Powłoki poddano także ocenie jakościowej w badaniach odporności na działanie obojętnej mgły solnej zgodnie z normą PN-EN ISO 9227:2007. Charakterystykę materiału badań przed i po badaniach korozyjnych przeprowadzono za pomocą skaningowej mikroskopii elektronowej oraz dyfrakcji promieni rentgenowskich. Sugerowaną przyczyną poprawy właściwości ochronnych powłoki Ni-W po obróbce cieplnej jest modyfikacja jej struktury.
EN
This work presents the results of investigations concerning an assessement of corrosion resistance of the Ni-W coatings electrodeposited on a carbon steel substrate using galvanostatic method, before and after heat treatment in air at temp. 900°C. Resistance to electrochemical corrosion was tested in 5% NaCl solution using potentiodynamic polarization technique and electrochemical impedance spectroscopy. The coatings were also subjected to a qualitative assessement in tests of resistance to neutral salt fog effect according to PN-EN ISO 9227:2007 standard. Characteristics of the material under investigation before and after corrosive tests was carried out using scanning electron micrsocopy and X-ray diffraction. Suggested reason for the improvement of protective properties of the Ni-W coating after heat treatment is the modification of its structure.
12
Content available remote Procesy korozyjne bezołowiowych stopów lutowniczych typu SnZn
PL
Ze względu na właściwości ołowiu i jego związków, które stanowią zagrożenie dla życia ludzkiego i środowiska naturalnego niezbędne jest wytwarzanie i poznanie właściwości nowych stopów lutowniczych nie zawierających w swoim składzie dodatków Pb. W artykule przedstawiono wyniki badań korozyjnych bezołowiowych stopów lutowniczych typu Sn-Zn oraz komercyjnego stopu Sn-Ag-Cu. Właściwości korozyjne określono na podstawie analizy krzywych woltamperometrycznych (krzywe polaryzacji) oraz widm impedancyjnych zarejestrowanych w roztworze Na2SO4 o stężeniu 0,5 M i o pH = 2.
EN
The development of lead-free solders has become an important task for material scientists, mainly due to health and environmental concerns induced by the lead content of conventional solders. The corrosion resistance of the next generation solders is one of the key factors responsible for reliability of solder joints. The paper focuses on the comparative studies of corrosion behaviour of Pb-free solder candidates of binary Sn-Zn systems and commercial alloy Sn-Ag-Cu (SAC305). The tests were done by means of voltametric and electrochemical impedance spectroscopy measurements carried out in the sulfate solution (pH = 2).
PL
W artykule przedstawiono wyniki badań korozyjnych nanokompozytowych powłok typu MoS2Ti oraz MoS2(Ti, W) otrzymywanych metodą rozpylania magnetronowego. Powłoki zostały wytworzone na stopie tytanu Ti-6Al-4V, utwardzonym dyfuzyjnie międzywęzłowymi atomami tlenu do twardości powierzchniowej ok. 33 HRC. Właściwości korozyjne badanych materiałów oszacowano na podstawie analizy krzywych woltamperometrycznych, które zarejestrowano w środowisku 0,5 M NaCl oraz w 0,5 M Na2SO4. W pracy również przedstawiono wyniki badań wykonanych techniką elektronowej mikroskopii skaningowej (SEM). Określono średni współczynnik tarcia oraz współczynnik odporności na zużycie oraz klasę adhezji metodą Daimler-Benz.
EN
The paper presents the study of corrosion properties of nanocomposite coatings MoS2Ti and MoS2(Ti, W) produced by magnetron sputtering method on titanium alloy Ti6Al4V. Corrosion resistances of the coatings were performed by means of voltametric measurements (polarization curves) carried out in the sodium sulfate and sodium chlorate solutions. Surfaces of the coatings were characterized using scanning electron microscopy (SEM). The paper presents the results of tribological tests. Average coefficient of friction and wear resistance were determined. Class of adhesion by Daimler-Benz method were identifi ed.
PL
Metody elektrochemiczne są szeroko stosowane w dziedzinie badań odporności korozyjnej metali i powłok. W artykule omówiono najczęściej stosowane techniki pomiarowe. Podano również przykłady ich zastosowania w oparciu o wyniki ekspertyz przeprowadzonych w Centrum Korozyjnym Instytutu Mechaniki Precyzyjnej.
EN
The electrochemical methods are widely used in the field of corrosion of metals and coatings. In this paper the most commonly used measurement tecYimqu.es are described. Examples of their use in the expertise carried out at Corrosion Centre of the Institute of Precision Mechanics is provided.
PL
Zbadano wpływ albuminy i γ-globuliny osocza wołowego na odporność korozyjną stopu biomedycznego M30NW. Pomiary korozyjne z wykorzystaniem metod elektrochemicznych przeprowadzono w odtlenionym buforowanym roztworze 0,9% NaCl o pH równym 7,4. Badania te przeprowadzone zostały w dniu 0 (badania przyspieszone korozji) i w ciągu 84 dni (badania korozji długoczasowej). W badaniach przyspieszonych korozji wyznaczono szereg wielkości charakteryzujących właściwości korozyjne badanego stopu M30NW: potencjał korozyjny Ecor, opór polaryzacyjny Rp, szybkość korozji CR, gęstość prądu w obszarze pasywnym i04 oraz potencjały przebicia Eb i repasywacji Erep. Stwierdzono, że dodatek albuminy i γ-globuliny do buforowanego roztworu 0,9% NaCl powoduje niewielkie pogorszenie odporności korozyjnej stopu M30NW w dniu 0. Pogorszenie tej odporności praktycznie nie zależy od rodzaju i stężenia białek. W badaniach korozji długoczasowej wykonywano pomiary potencjału korozyjnego i charakterystyk Stern-Geary'ego. Na podstawie uzyskanych wyników stwierdzono, że odporność korozyjna stopu M30NW wzrasta we wszystkich roztworach, z tym że w obecności albuminy wzrost ten jest słabszy niż w obecności γ-globuliny.
EN
In this study we investigated the influence of bovine serum albumin and γ-globulin on the corrosion resistance of M30NW biomedical alloy. Corrosion measurements using electrochemical methods were carried out in deoxygenated buffered 0.9% NaCl solution at pH of 7.4. Corrosion tests were performed on day 0 (accelerated corrosion test) and within 84 days (long-term corrosion test). In accelerated corrosion tests numerous parameters characterizing the corrosion properties of investigated M30NW alloy were determined: corrosion potential Ecor, polarization resistance Rp, corrosion rate CR, passive current density i0 4, breakdown potential Eb and repassivation potential Erep. It was stated that addition of albumin and γ-globulin to buffered 0.9% NaCl solution causes a slight deterioration of corrosion resistance of M30NW alloy. The effect practically does not depend on the type and concentration of proteins. In long-term corrosion test were performed measurements of corrosion potential and Stern-Geary's characteristics. Based on obtained results it was stated that corrosion resistance of M30NW alloy increases in all solutions, but in the presence of albumin, the growth is weaker than in the presence of γ-globulin.
PL
Stopy magnezu zaliczane są do grupy metali lekkich o małym ciężarze właściwym i o dużej plastyczności, module sprężystości pozwalające na przenoszenie dużych obciążeń. W celu zwiększenia odporności korozyjnej stopów magnezu bardzo często wykorzystuje się chemiczne oraz fizyczne metody obróbki powierzchni, polegające głównie na wytworzeniu powłok stanowiących barierę pomiędzy metalem, a otaczającym środowiskiem. Powłoki te wykonuje się w celu czasowego zabezpieczenia metalu przed korozją oraz w celu zwiększenia przyczepności powłok malarskich. W pracy przedstawiono wpływ powłok tlenkowych typu SiO2 wytworzonych w różnych procesach na właściwości korozyjne stopu magnezu AZ91. Powłoki wykonano z zastosowaniem procesu chemicznego opartego na zjawisku żelowania typu "zol-żel" oraz w procesie osadzania chemicznego wspomaganego plazmą (PECVD). Właściwości korozyjne badanych materiałów określono na podstawie analizy krzywych woltamperometrycznych. Wykonano również badania mikroskopowe z zastosowaniem technik SEM/EDS. Najlepszymi właściwościami korozyjnymi charakteryzowała się powłoka o grubości 1100 nm wytworzona w procesie PECVD. Jednakże dla wszystkich powłok SiO2 zaobserwowano występowanie korozji wżerowej.
EN
Magnesium alloys are currently considered as light alloys with good weight - strengthratio and good cast ability, weld ability, possibility of high speed milling, recycling ability. However, poor corrosion resistance requires the use of surface treatment. The paper presents the study of corrosion properties of magnesium alloy AZ91 with SiO2 coatings. The coatings were produced in the radio frequency plasma PECVD (Plasma Enhanced Chemical Vapor Deposition) and in sol-gel process. Corrosion resistance of the coatings were performed by means of voltamertic measurements (polarization curves) carried out in sodium chlorate solutions. Surfaces of the coatings were characterized using scanning electron microscopy (SEM). The smallest corrosion current densities for sample AZ91 with PECVD coatings were obtained. However, for all samples with oxide coatings pitting corrosion were obtained.
PL
W pracy przedstawiono wpływ powłok SiO2 wytworzonych w procesie plazmowym PECVD (Plasma Enhanced Chemical Vapour Deposition), z wykorzystaniem plazmy wysokiej częstotliwości (13,56 MHz), na właściwości korozyjne stopów magnezu AZ31, AZ32, AZ91. Na każdym ze stopów Mg wykonano powłoki SiO2 o trzech grubościach: 12, 22 i 44 nm. Właściwości korozyjne badanych powłok określono na podstawie analizy krzywych woltamperometrycznych. Uzyskane wyniki pokazują wzrost odporności korozyjnej stopów magnezu, wraz ze wzrostem grubości osadzonej powłoki tlenkowej. Największy spadek wartości gęstości prądu korozyjnego zaobserwowano dla stopu AZ91 z powłoką tlenkową o grubości 44 nm. Dla pozostałych stopów magnezu wartości gęstości prądu korozyjnego, dla tej powłoki, również spadają ale w znacznie mniejszym stopniu. We wszystkich przypadkach natomiast tj. dla czystych stopów jak i dla stopów wraz z powłoką tlenkową zaobserwowano występowanie korozji wżerowej.
EN
In this work, the influence of SiO2coatings produced in the radio frequency plasma PECVD (Plasma Enhanced Chemical Vapor Deposition) on the corrosion properties of magnesium alloys AZ31, AZ32 and AZ91, has been reported. At each Mg alloy the SiO2 coatings with three different thicknesses: 12, 22 and 44 nm, was performed. Corrosion properties of investigated coatings was based on analysis of the voltammetric curves. Presented results have shown an increase in corrosion resistance of magnesium alloys, with increasing thickness of the deposited oxide film. The largest decrease of corrosion current was observed for the AZ91 alloy coated with an oxide thickness of 44 nm. For other values of magnesium alloys corrosion current decreased but in a much lesser extent. In all cases, for pure alloys and for alloys with the oxide coating was observed pitting corrosion.
PL
W pracy przedstawiono zmiany odporności korozyjnej powłok SiO2 wytworzonych w procesie plazmowym PECVD (Plasma Enhanced Chemical Vapour Deposition), z wykorzystaniem plazmy wysokiej częstotliwości (13,56 MHz), pod wpływem wprowadzenia do ich objętości azotu. Badaniom poddane zostały dwa stopy magnezu AZ32 i AZ91. Na każdym ze stopów Mg wykonano powłokę SiO2 o grubości 1000 nm, oraz powłoki SiOxNy (tlenkoazotek) o grubościach 60 nm i 500 nm. Uzyskane wyniki zestawione zostały z próbkami referencyjnymi wymienionych stopów. Właściwości korozyjne badanych powłok określono na podstawie analizy krzywych woltamperometrycznych. Uzyskane wyniki pokazują, że wprowadzenie azotu do objętości cienkiej warstwy plazmowo wytworzonej SiO2, czyli wytworzenie warstwy SiOxNy poprawia odporność korozyjną obu badanych stopów magnezu. Przy znacznie mniejszej grubości powłoki SiOxNy w stosunku do grubości powłoki tlenkowej SiO2 uzyskano zbliżone spadki gęstości prądu korozyjnego.
EN
In this work, the effect of nitrogen introduction into the bulk of SiO2 coatings produced in the radio frequency plasma PECVD (Plasma Enhanced Chemical Vapor Deposition) on the corrosion properties of magnesium alloys AZ32 and AZ91, has been reported. At each Mg alloys the SiO2 coating with thicknesses 1000 nm and the SiOxNy coatings with thicknesses 60 nm and 500 nm, was performed. Corrosion properties of investigated coatings was based on analysis of the voltammetric curves. The results show that the introduction of nitrogen into the bulk of plasma produced a thin layer of SiO2, which produce SiOxNy layer with thickness it improves the corrosion resistance of both studies Mg alloys. A similar decrease in corrosion current density was observed for SiOxNy film thickness of 500 nm and SiO2 film thickness of 1000 nm. The obtained results show that the introduction of nitrogen into the bulk of SiO2 layer improves its the corrosion resistance. For a thinner (500 nm) SiOxNy layer is observed similar decline the corrosion current density as for the oxide film with thickness 1000 nm.