Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  dental ceramics
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The strength of the connection between orthodontic brackets and sandblasted dental ceramics was evaluated. The strength of the bracket-ceramics connection was determined in four time intervals. Based on the obtained results, basic statistics were calculated. For the comparative analysis of average values, the following were used: ANOVA analysis of variance and Tukey’s HSD post-hoc test at the significance level of α = 0.05. The statistical analysis performed did not show any influence of the method of surface treatment (with sanding, without sanding) between orthodontic brackets and ceramics. At the same time, it has been shown that with samples storing time in aqueous environment, the quality of the connection decreases significantly, regardless of the surface treatment method used.
PL
Zbadano wytrzymałość połączenia zamków ortodontycznych z ceramiką dentystyczną poddaną piaskowaniu. Wytrzymałość połączenia zamek-ceramika wyznaczono w czterech przedziałach czasowych. Do analizy porównawczej wartości średnich zastosowano m.in. analizę wariancji ANOVA oraz test post - hoc Tukeya HSD na poziomie istotności α = 0,05. Przeprowadzona analiza statystyczna nie wykazała wpływu metody obróbki powierzchni porcelany dentystycznej (z piaskowaniem, bez piaskowania) na jakość połączenia zamków ortodontycznych z ceramiką. Jednocześnie wykazano, że wraz z upływem czasu przechowywania próbek w środowisku wodnym, istotnie zmniejsza się jakość połączenia, niezależnie od stosowanej metody obróbki powierzchni.
PL
Komercyjnie czysty tytan stanowi jeden z czołowych materiałów biointegrujący się z tkankami przyzębia, co wykorzystuje się na co dzień w protetyce stomatologicznej. Wysoka reaktywność z tlenem, niska rozszerzalność termiczna tytanu i zjawisko pasywacji utrudniają obróbkę tytanu, a w szczególności połączenie z materiałami licującymi, jak ceramika stomatologiczna. Analizując obecne w piśmiennictwie doniesienia, opisujące zarówno pozytywny, jak i negatywny wpływ warstwy tlenkowej na połączenie tytan–ceramika, podjęto próbę elektrochemicznego wytworzenia powłok pasywnych z kąpieli zawierającej H2SO4 na komercyjnie czystym tytanie, mogącym stanowić podbudowę koron i mostów protetycznych. Materiały i metody. Tytanowe walce Grade 2 (śr. 20 mm i wys. 5 mm) szlifowano i wypolerowano. Skład stopu określono metodą rentgenowskiej analizy fluorescencyjnej. Próbki podzielono na 3 grupy i poddano oksydacji anodowej w 1M kwasie siarkowym przy stałych napięciach: 120V, 160V, 200V, t=1min. Warstwy tlenkowe poddano badaniu dyfrakcji rentgenowskiej, analizie składu chemicznego oraz obserwacji SEM. Wyniki. Otrzymano warstwy grubości 1 μm do 7,1 μm. W warstwie anodowanej, oprócz tlenku tytanu, występują domieszki siarki. Tezy. Wybór napięcia anodowania wpływa na grubość otrzymanych warstw, co determinuje możliwość praktycznego zastosowania. Warstwy ponad 1 μm mogą ulegać łuszczeniu i pękaniu. Co więcej, zbyt cienkie powłoki wykazują ubytki i nie pokrywają całej powierzchni metalu. Wnioski. Zwiększenie napięcie reakcji nie tylko wpływa na pogrubienie warstwy, ale również na porowatość. Możliwość kontrolowania średnicy porowatości przyłożonym napięciem anodowania może zapewnić poprawę mikroretencji ceramiki stomatologicznej. Biorąc pod uwagę grubość wytworzonych warstw, największe zalety prak-tyczne wydają się mieć powłoki wytworzone pod napięciem 120V.
EN
Commercially pure titanium is the leading biointegrating material, which is used in everyday dental prosthetics. High reactivity with oxygen, low thermal expansion and passivation impede titanium processing, especially bonding with veneering materials like dental ceramics. After analyzing the literature with view to positive and negative impact of titanium oxide layer on boning strength between titanium and dental ceramics, an attempt was made to fabricate the anodic layers by means of electrochemical oxidation in 1M sulphuric acid on CP-Ti which will subsequently be used as a framework of PFM dental prosthesis. Materials and methods. Grade 2 Titanium cylinders (20 mm diameter, 5 mm high) were grinded and polished. Chemical composition was determined by X-ray fluorescent analysis. Samples were divided into 3 groups and oxidized in 1M sulphuric acid in DC voltage: 120V, 160V, 200V, t=1min. Oxide layers undergone X-ray diffraction examina-tion, chemical composition analysis and SEM observations. Results. Layers of 1 μm to 7,1μm were obtained. Layers is composed not only of titanium oxide but also contains sulphur. Thesis: Selection of anodizing voltage affects layer thickness thus determinates its practical application. Layers over 1μm thick may crack and flake off, furthermore, too thin layers show surface loss and do not cover the entire surface of titanium. Findings: Increased voltage not only results in layer thickening but also affects porosity. Pore size control may contribute to enhanced porcelain microretention. Considering layers thickness and practical application, 120V layers seem to have the most advantages.
3
Content available remote Właściwości ceramiki litowo-silikatowej po obróbce jej powierzchni
PL
Przedstawiono wyniki badania struktury powierzchni ceramiki krzemianu litu wzmocnionej tlenkiem cyrkonu oraz zmian składu chemicznego jej powierzchni po zastosowaniu obróbki strumieniowo-ściernej korundem szlachetnym o wielkości ziaren 50 μm, trawienia kwasem fluorowodorowym oraz kombinacji tych metod. Zastosowane metody znacząco wpłynęły na strukturę powierzchni ceramiki oraz wytrzymałość jej połączenia z materiałem kompozytowym. Wydłużenie czasu trawienia nie wpłynęło znacząco na rozwinięcie badanej powierzchni. Największą wytrzymałość połączenia ceramika-kompozyt uzyskano po piaskowaniu i trawieniu jej powierzchni 9-proc. kwasem fluorowodorowym przez 60 s.
EN
ZrO₂-reinforced Li silicate ceramic surface was treated by sandblasting with air-borne 50 μm Al₂O₃ particles, etching with 9% HF, and by combination of both methods. All treatments resulted in increasing bond strength to composite material. Prolonged HF etching did not change significantly surface morphol. The highest bond strength was achieved after sandblasting with Al₂O₃ and 60 s long HF etching of ceramic surface.
PL
Połączenie podbudowy protetycznej z warstwą porcelany ma znaczący wpływ na jakość uzupełnienia dentystycznego. Rozwój selektywnej laserowej mikro metalurgii proszków, przyczynił się do rozpoczęcia badań tej technologii w dziedzinie techniki dentystycznej. W artykule przedstawiono ocenę wpływu kondycjonowania piaskiem Al2O3 o gradacji: 50μm, 110μm, 250μm, powierzchni spieków przygotowanych laserowo, na klasę połączenia z fazą licującą. Wnioski zostały formułowane na podstawie wyników z przeprowadzonych pomiarów chropowatości i falistości powierzchni spieków laserowych.
EN
The foundation prosthetic connection with a layer of porcelain has a significant impact on the quality of the dental supplement. The development of selective laser micro powders metalurgy, has contributed to the start of the examination of this technology in the field of dental technology. The article presents an impact assessment conditioning sand Al2O3 grit : 50μm, 110 μm, 250 μm, laser- sintered surface prepared, class connection with the phase of the veneering. Proposals were formulated based on the results of the measurements of roughness and waviness floor space laser sintered.
5
Content available Trzypunktowe zginanie próbki z dwutlenku cyrkonu
PL
Celem badania była analiza właściwości mechanicznych materiału Cyrkon Lava, który jest stosowany do wytworzenia koron dentystycznych oraz mostów poprzez proces frezowania. Badania dotyczyły procesu trzypunktowego zginania na maszynie wytrzymałościowej Instron 8874 według normy PN-EN 843-1. Przeprowadzone badania pozwalają wnioskować o wysokiej wytrzymałości na zginanie oraz wpływie obrobionej powierzchni próbki na właściwości mechaniczne.
EN
Aim of this study was to evaluate mechanical properties of Cyrkon Lava material, used in production of dental crowns and bridges in the milling process. Research dealt with the three-point bending in the Instron 8874 testing machine in accordance with the PN-EN 843-1 standard. The research results confirm high flexural strength and the impact of sample surface on mechanical properties.
PL
Uzupełnienia protetyczne na podbudowie metalicznej z licowaną ceramiką w obecnej protetyce stomatologicznej są najpopularniejszą i najchętniej wykorzystywaną kombinacją materiałów. Połączenie metal- ceramika zyskało ogromną popularność przy wykonywaniu koron, mostów ze względu nie tylko na walory estetyczne, poprzez ceramikę, ale przede wszystkim dzięki uzyskaniu własności wytrzymałościowych przez wykonanie metalowej podbudowy, osadzonej bezpośrednio na oszlifowane kikuty zębów czy implanty. Połączenie obu materiałów nie zawsze jest idealne. Uzupełnienie często nie wykazują żadnych nieprawidłowości w przypadku obserwacji zewnętrznej. Nie oznacza to, iż w obszarze chemicznego połączenia tych materiałów nie ma swoistych, mikroskopijnych wad. Praca przedstawia typy wad w obszarze styku dwóch różnych faz materiałów protetycznych oraz określa co mogą spowodować.
EN
Metallic porcelain veneered dental restorations are currently the most commonly chosen type of restoration in the dental profession. The use of ceramics fused to metal has gained wide popularity when choosing a material suitable for making dental crowns and bridges not only for aesthetic reasons, but more importantly due to the strength properties of the metallic substructure when placed on the previously grinded dental stump. The process of fusing dental ceramic to the metallic substructure does not always prove to be a success. Metal-ceramic dental restorations do not always exhibit flaws visible to the eye on the outer surface; often the metal-ceramic fusing process creates microscopic flaws. This thesis presents the different kinds of flaws which can occur when bonding two different kinds of prosthetic materials together and the outcome we can expect as a result.
PL
W branży techniki dentystycznej pojawiła się nowa technologia CAD/CAM wykonawstwa pełnoceramicznych koron i mostów. Na rynku materiałów dla techniki dentystycznej dostępnych jest kilkanaście systemów pełnoceramicznych oferujących materiały do wykonania ceramicznej podbudowy i licowania. System Cercon Smart Ceramics firmy DeguDent składa się z ceramiki cyrkonowej przeznaczonej na podbudowy i porcelany skaleniowej stosowanej do licowania tych podbudów. W pracy przedstawiono charakter struktury połączenia tych materiałów, a także sprawdzono czy porcelana innego producenta może być stosowana zamiennie z porcelaną zalecaną w systemie Cercon.
EN
The purpose of thesis is characterizing connection between cercon base materials and covering porcelain and checking which forces (mechanical or chemical) are responsible too linkage materials. At the second part of thesis is described preparation samples of materials to research. Executed observations on optical microscope Zeiss M1m Imager and scanning electron microscope FEI E-SEM XL30 with X EDAX GEMINI 4000. Got results of qualitative and quantitative analyses which have showed character of materials connection. Researched materials Cercon Base, Cercon Ceram Kiss and Lava Ceram are compatible for each other.
PL
W pracy przedstawiono rezultaty badań powłok przejściowych SiO2-TiO2 nanoszonych na podłoże tytanowe metodą zol-żel oraz napalanej niskotopliwej porcelany dentystycznej Triceram. Analizowano mikrostrukturę połączenia powłok zol-żel i wykonano badania przyczepności warstwy ceramicznej w oparciu o normę PN-EN ISO 9693. Na postawie przeprowadzonych badań stwierdzono, że zastosowanie powłok przejściowych zol-żel pomiędzy metalem podłoża: tytanem i jego stopem Ti6Al4V ELI a porcelaną dentystyczną powoduje wzrost wytrzymałości połączenia od 25% do 28% w porównaniu do metalu bazowego poddanego jedynie konwencjonalnej obróbce-piaskowania. Uzyskany układ kompozytowy metal - powłoka pośrednia zol-żel-porcelana spełnia wymagania jakościowe stawiane implantom stomatologicznym umożliwiając podniesienie ich jakości, trwałości i wytrzymałości i może być stosowany w laboratoriach stomatologicznych.
EN
In this work the results of the study of SiO2-TiO2 intermediate coatings on titanium substrate, produced by sol-gel method and low-fusing Triceram dental porcelain were presented. The microstructure of joint sol-gel coatings and adhesion tests of ceramic coatings according to PN-EN ISO 9693 standards were examined. The above studies led to the conclusion that the application of sol-gel intermediate coatings between metal substrate: titanium and Ti6Al4V ELI alloy and dental porcelain cause the increase of bond strength of metal-porcelain joint from 25% to 28% in comparison with metal substrate after sand blasting conventional treatment. The obtained metal - intermediate coating sol-gel - porcelain composite structure met the qualitative demands of dental implants enabling increasing their quality, durability and strength and may be used in the dental laboratories.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.