EN
In this study, the corrosion performances of ammonium copper quaternary (ACQ) and boric acid (BA) wood preservatives were investigated, with micronized copper quaternary (MCQ) and nano boron (NB) used as reference materials. In the study, Scots pine (Pinus sylvestris L.) wood samples were impregnated according to the full-cell process method with ACQ at 2.4% concentration, BA at 4% and MCQ and NB at 1%. The ACQ- and BA-impregnated samples were then impregnated for a second time using five different water-repellent materials: tall oil, linseed oil, sodium silicate, methyl hydrogen silicone and N'-N-(1,8- naphthalyl)hydroxylamine. Polyethylene glycol (PEG) 600 and aluminum sulfate were introduced as single impregnations in the form of homogeneous mixtures with ACQ and BA. The corrosion properties of the impregnated and control samples, including metal weight loss (MWL) and corrosion depth, were examined. The MWL values of the ACQ-impregnated samples showed an increase compared to the control group. The MWL values of the MCQ-impregnated samples were lower than those of the samples impregnated with ACQ, whilst the MWL values of the BA-impregnated samples were higher than those of the samples impregnated with NB.
EN
Selective Laser Melting (SLM) is a modern manufacturing method with many applications in medicine, aerospace and auto-motive industries. SLM processed materials are characterized by good dimensional accuracy and properties comparable or superior to materials obtained by traditional processing methods. In this paper an SLM process was used to obtain 316L stainless steel parts. This paper presents the microstructure, chemical and phase composition, physicochemical and electrochemical properties of 12 groups of tested samples, differentiated by the SLM processing parameters. Based on the investigation, it can be inferred that the selection of the appropriate SLM parameters is very important to determined final material properties. The samples producedwith the energy density E = 600 J/mm3 were observed to possess optimum properties - a homogeneous structure, density closest to the desired one, good wettability and pitting corrosion resistance.
3
EN
Corrosion is a main problem for longtime exploration of heat exchangers in automotive industry. Proper selection of accelerated corrosion test for newly developed material is a key aspect for aluminum industry. The selection of material based on corrosion test includes test duration, chemical spray composition, temperature and number of cycles. The paper present comparison of old and newly developed accelerated corrosion tests for testing automotive heat exchanger. The accelerated test results are comprised with heat exchanger taken from market after life cycle.
EN
The quality requirements for materials dedicated to medical applications mainly refer to their the impact on the body’s tissues and body fluids. From a technical point of view, this mainly concerns to the corrosive characteristics of materials in media with different aggressiveness. The potential use of Nd-Fe-B bonded composites in restorative medicine is associated with the elimination of a toxic epoxy resin from the composite. The commercial mixtures containing commercial acrylic material polymerizing at different temperatures have been used to consolidate high-coercive Nd-(Fe,Co)-B powders. In this paper, the results of corrosion tests for Nd-(Fe,Co)-B/polymer composites with two types of acrylics polymers have been presented. The electrochemical tests have been carried out in various solutions (sulphate solution acidified to pH = 4 and 6, Ringer solution, phosphate solution acidified to pH = 3 also with the addition of 0.1 M Cl-) to present the spectrum of corrosive media impact on the material. It has been found that the use of low temperature polymer as a binder is more beneficial both in terms of corrosion resistance as well as for technical and economic reasons.
PL
Wymagania jakościowe dla materiałów przeznaczonych do zastosowań medycznych głównie odnoszą się do ich wpływu na tkanki miękkie i płyny ustrojowe. Z technicznego punktu widzenia dotyczy to przede wszystkim korozyjnych właściwości materiałów w mediach o różnej agresywności. Zastosowanie w medycynie naprawczej kompozytów Nd-Fe-B wiązanych polimerem pozwala wyeliminować toksyczną żywicę epoksydową. Dlatego też do konsolidacji proszków Nd-(Fe,Co)-B o wysokiej koercji zastosowano komercyjne mieszanki zawierające PMMA polimeryzujące w różnych temperaturach. W niniejszej pracy przedstawiono wyniki badań korozyjnych dla kompozytów Nd-(Fe,Co)-B/biopolimer z dwoma rodzajami polimerów akrylowych. Aby przedstawić wpływ mediów korozyjnych na materiał przeprowadzono testy elektrochemiczne w różnych roztworach (roztwór siarczanowy zakwaszony do pH = 4 i 6, roztwór Ringera roztwór fosforanowy zakwaszony do pH = 3, również z dodatkiem 0,1 M Cl-). Stwierdzono, że zastosowanie polimeru sieciującego w niskich temperaturach, jako środka wiążącego jest bardziej korzystne zarówno pod względem odporności na korozję, jak i ze względów technicznych i ekonomicznych.
PL
W artykule przedstawiono wyniki badania odporności korozyjnej kolektorów prądowych akumulatorów ołowiowych. Przebadano sześć typów kratek akumulatorowych różniących się między sobą zarówno metodą wytworzenia jak i składem. Porównano odporność korozyjną kolektorów prądowych wytworzonych metodą odlewania grawitacyjnego, punchingu oraz tzw. metodą cięto-ciągnioną. Badane kolektory prądowe zostały wykonane ze stopów o zróżnicowanym składzie, bazujących na ołowiu oraz dodatkach stopowych. Przeprowadzone badania utleniania elektrochemicznego pozwoliły zaobserwować różnice w zachowaniu kratek akumulatorowych w zależności od zastosowanego składu stopowego oraz metody wytworzenia. Dobrą odporność korozyjną, w warunkach przeprowadzonego testu w stosunku do pozostałych układów, wykazały kratki ołowiowe oznaczone jako F, wykonane techniką punching. Najwyższym średnim ubytkiem masy badanych próbek wykazały się kolektory prądowe oznaczone jako C oraz D, które wykonano techniką grawitacyjną. Nośniki masy płyt dodatnich oznaczone jako B, a wytworzone techniką cięto-ciągnioną, charakteryzowały się dobrą spójnością struktury. W przypadku próbki kratki oznaczonej jako F (punching), stwierdzono znaczne popękania w strukturze.
EN
The article describes results of corrosion tests carried out for lead-acid batteries grids. Six types of grids varying in both production technology and composition were characterized. The differences in their dimensions were noticed. The production technologies the grids were made to were: punching, expanding technology and gravity casting. The studied grids are made of alloys of different composition based on lead and alloys of additives. The electrochemical oxidation indicated some differences in behavior of grids depending on their alloy composition and production technology. The corrosion tests showed that samples marked as "F" with grids made by punching technology had a good corrosion resistance, compared to other ones. The samples marked as "C" and "D" with grids made by gravity casting method showed the highest average mass loss. The sample marked as "B" with positive plates based on grids made by expanding method was characterized as having a good structural coherence. In turn, significant cracking of the structure was noticed for the F sample (punching method).
7
Content available remote Odporność na korozję metalowych blach perforowanych
PL
W artykule przedstawiono podstawowe rodzaje blach perforowanych, stosowane w budownictwie. Zinterpretowano wyniki testów przyspieszonej korozji blach perforowanych stalowych i stalowych ocynkowanych spełniających wymagania PN-EN 10346:2011. W badaniach wykorzystano blachy perforowane zabezpieczone antykorozyjnie metodą lakierowania proszkowego. Wyniki odporności na działanie mgły solnej i wilgotnej atmosfery zawierającej SO2 dowodzą, że lakierowanie proszkowe może stanowić skuteczne zabezpieczenie przed działaniem agresywnego środowiska korozyjnego. Szczególnie nanoszenie powłoki lakierowej w dwóch warstwach pozwala na pokrycie zaostrzonych krawędzi powstałych podczas procesu perforacji.
EN
The paper presents basic types of metal sheets perforated used in constructions. The results of accelerated corrosion tests of galvanized steel and steel perforated sheets meeting the requirements of EN 10346:2011 have been interpreted. In the tests perforated sheets coated with anticorrosive powder coating method were used. Based on the resistance to salt spray and humid atmosphere containing SO2, it has been found that powder coating can provide effective protection against the aggressive corrosive environment. In particular, application of the coating varnish in two layers allows to cover the sharpened edge formed during the perforation process.
PL
W artykule przedstawiono zagadnienie korozyjności armatury wodociągowej oraz zaproponowano metodę oceny pod tym kątem jakości materiałów, adoptując standardy badań korozyjnych w sztucznych atmosferach rozwinięte dla powłok antykorozyjnych. Testy przeprowadzono w mgle solnej o odczynie obojętnym oraz w środowisku kwaśnym. Korozja elementów od różnych producentów postępowała w niejednakowym stopniu, co wynikało z różnej jakości materiałów konstrukcyjnych oraz dokładności pokrycia elementów powłokami ochronnymi, a także odmiennych warunków obchodzenia się z nimi podczas magazynowania i transportu. Zastosowane metody testowe wymagają dopracowania tak, aby warunki badań porównywanych elementów były jak najbardziej podobne, co jest wyzwaniem m.in. ze względu na różne kształty elementów oraz niejednakową grubość powłok ochronnych.
EN
In the paper the problem of corrosivity of water fittings was presented and the method of material quality evaluation in this respect was proposed by adopting corrosion test standards in artificial atmospheres for anticorrosion coatings. The tests were carried out in the neutral salt spray and in the acid environment. Corrosion of the elements from different producers developed in a non-uniform way due to different quality of construction materials and accuracy of the anticorrosion coating, as well as unequal way of their handling at storage and transport. The applied test methods require development in order to make the test conditions for compared elements as similar as possible, what is a challenge especially due to different shapes of elements and uneven thickness of protection coatings.
PL
W pracy przedstawiono wyniki badań elektrycznych i odporności korozyjnej ogniw ołowiowych z płytami dodatnimi wytworzonymi z wykorzystaniem odpadowego materiału elektrodowego jako domieszki do masy aktywnej. Do badań użyto nośniki mas aktywnych wykonane metodą ciętociągnioną, ze stopów PbCaSn, na które ręcznie naniesiono pastę dodatnią z różną zawartością masy odpadowej. Przeprowadzone badania pozwoliły zaobserwować różnice w zachowania ogniw w zależności od ilości wprowadzonego materiału odpadowego. Badania elektryczne wykazały, że płyty zawierające 5 i 10% dodatku odpadowej masy aktywnej wykazują pojemności wyższe niż płyty o standardowym składzie. Badania odporności korozyjnej wytworzonych płyt dodatnich z dodatkiem masy odpadowej nie wykazały śladów korozji.
EN
The paper presents electrical and corrosion resistance results of leadacid cells with positive plates produced using waste electrode material as addition to the active mass. The grids used in the study were made of PbCaSn alloy obtained by the expanded metal method. Plates preparation consisted in manual application of the paste with different waste electrode material on the grids. The study shows differences in cells behavior dependent on the amount of the introduced waste material. In addition, positive plates containing 5 and 10% wt. of waste active mass have higher capacity than a plate with standard formulation. Analyses of the produced positive plates containing waste mass that were submitted to a corrosion test showed no signs of corrosion.
PL
W artykule przedstawiono nowo opracowane laboratoryjne stanowisko badawcze przeznaczone do badań korozyjnych, które składa się z pieca grzewczego L/05/12, precyzyjnej wagi laboratoryjnej PS 210/C/2 oraz programatora. Zaprezentowano możliwości badawcze stanowiska oraz wybrane wyniki badań wysokotemperaturowych testów korozyjnych materiałów powłokowych.
EN
The new elaborated laboratory research stand for the corrosion tests was presented. The furnace L/05/12 and the laboratory precision Libra PS 210/C/2 for the basie construction of the stand are used. The research capabilities of the stand and the selected investigation results of experimental high tem­perature corrosion tests of the chosen corrosion resistance coatings were presented.
PL
W pracy przedstawiono wyniki badań odporności korozyjnej powłok cynkowych otrzymanych różnymi technologiami nanoszenia. Określono grubość otrzymanych powłok. Próbki poddano porównawczej próbie korozyjnej w obojętnej mgle solnej chlorku wapnia bez i z dodatkiem inhibitora korozji M-605 PS. Na podstawie wyników badań obliczono zmiany masy próbek i szybkość korozji powłok cynkowych w badanych warunkach. Przedstawiono je w formie graficznej na rysunkach 1÷4. Podczas próby korozyjnej prowadzono oględziny wizualne, które przedstawiono na rysunkach 5 i 6. Na podstawie przeprowadzonych badań stwierdzono, że dodatek inhibitora spowodował znaczne obniżenie szybkości korozji cynku nakładanego metodą zanurzeniową i metodą natrysku cieplnego. Po zastosowaniu inhibitora M-605 PS na powierzchni badanych próbek zaobserwowano mniejsze ilości białego nalotu produktów korozji cynku.
EN
This paper presents the results of the corrosion resistance of zinc coatings obtained by different application techniques. The thickness of the coatings was determined. Samples were subjected to comparative corrosion in a neutral calcium chloride salt spray with and without the addition ofcorrosion inibitor M-605 PS. Based on the test results, the weight change of the samples was calculated and the rate of zinc coatings corrosion in the test conditions was determined. The results are presented in graphical form in Figures 1 to 4. During the corrosion test, a visual inspection was carried out, as shown in Figures 5 and 6. On the basis ofthe test results, it was found that the addition ofthe inhibitor caused a significant reduction in the corrosion rate ofzinc applied by immersion and thermal spray. After applying inhibitor M-605 PS on the surface ofthe samples, minor amounts ofthe white dust ofzinc corrosion products were observed.
PL
Rury z tworzyw sztucznych mogą być stosowane w instalacjach ogrzewczych pod warunkiem posiadania w swojej strukturze warstwy barierowej, zabezpieczającej skutecznie przed dyfuzją tlenu, zapewniając w ten sposób ochronę stalowych elementów instalacji przed korozją. W artykule opisano budowę nowego stanowiska badawczego oraz metodę pomiaru szybkości przenikania tlenu przez ścianki rur wielowarstwowych w całym zakresie temperatur pracy instalacji ogrzewczych. Wyniki badań wykonanych w tym stanowisku wykazały, że duża część rur z tworzyw sztucznych stosowanych w Polsce w instalacjach ogrzewczych nie jest w dostatecznym stopniu zabezpieczona przed dyfuzją tlenu.
EN
Thermoplastic pipe may be used in the heating systems only if it is produced with additional layer which forms oxygen barrier, protecting against oxygen diffusion and hence, against corrosion of steel. The paper describes the structure of new test stand and the test method for measuring the rate of permeability of oxygen through the wall of multilayer pipes at all temperatures occurring in heating systems. Results of tests show that in Poland a big part of thermoplastic pipes used in heating systems is not properly protected against oxygen diffusion.
13
Content available remote Corrosion tests of refractory materials
EN
The paper is devoted to corrosion tests of various types of refractory materials at the interface with liquid steel and slag. Two evaluation procedures were created for the corrosion test, which consist of various experimental methods - for example: visual evaluation, microanalysis of structure, X-rays phase analysis and fluorescence spectrometry. The first type of corrosion test is aimed on tundish nozzle, which was put to the test in the steel. The second type of corrosion test is aimed on lining in the pouring ladle, which was put to the test in the slag. From, the results it is evident which of the used methods are proper for the evaluation of refractory materials under different conditions.
PL
Niniejsza praca poświęcona jest badaniom korozyjnosci różnego typu materiałów ogniotrwałych na granicy faz pomiędzy stałą ciekłą i żużlem. Opracowano dwie procedury badań korozyjności, które obejmują różne metody doświadczalne - na przykład: ocenę wzrokową, mikroanalizę struktury, rentgenowską analizę fazową oraz spektrometrię fluorescencyjną. Pierwszy rodzaj badań korozyjnosci dotyczy wylewu kadzi pośredniej, który został poddany badaniom w stali. Drugi rodzaj prób korozyjnych służy do badania wyłożenia kadzi odlewniczej, które zostało poddane badaniom w żużlu. Na podstawie wyników stwierdzono, którą z zastosowanych metod należy zastosować do oceny materiałów ogniotrwałych w różnych warunkach.
PL
W artykule przedstawiono wyniki badań odporności korozyjnej powłok otrzymanych metodą indywidualnego zanurzania w kąpieli Zn-5% Al. Przeprowadzono badania parametrów elektrochemicznych procesów korozji oraz przyśpieszone laboratoryjne badania w obojętnej mgle solnej. Przeprowadzono również badania korozyjne w wilgotnej atmosferze zawierającej związki siarki. Ujawniono strukturę oraz określono grubość badanych powłok. Odporność korozyjną powłok Zn-5% Al porównywano z odpornością korozyjną zanurzeniowych powłok cynkowych otrzymywanych w tradycyjnej temperaturze cynkowania oraz w procesie cynkowania wysokotemperaturowego. Otrzymane wyniki pozwoliły określić parametry elektrochemiczne procesu korozji i kinetykę jej przebiegu. Stwierdzono, że badane powłoki Zn-5% Al charakteryzują się znacznie lepszą odpornością korozyjną od powłok cynkowych.
EN
This paper presents the results of investigations on corrosion resistance of coatings obtained by batch hot dip method in Zn-5% Al bath. Electrochemical corrosion measurements on corrosion test in the neutral salt spray was carried out. The sulphur dioxide test with condensation of moisture were also made. The structure and thickness of coatings was determined. Corrosion resistance of Zn-5% Al coatings were compared with corrosion resistance of hot dip coatings obtained in the traditional of the galvanizing temperature and high temperature hot dip process. Results of this investigations permitted us to qualify electrochemical parameters of corrosion process and kinetics of its running. The better corrosion resistance of Zn-5% Al coatings in comparison with Zn coatings have been found.