Corrosion inhibitors in the antifreeze include both inorganic and organic compounds. Organic additives applied in the antifreeze usually form thinner protective coatings. In spite of this fact, it is believed that they protect the exposed surfaces against corrosion more efficiently than fluids with inorganic additives. This work investigates whether the effects on the steel surface occurring due to the antifreeze meet key normative requirements. Microscopic imaging was used to identify the alterations in the surface invisible in the macro scale. The tests aimed to evaluate the potential of the antifreeze intended for combustion engines in the perspective of applying them in HVAC systems.
PL
Inhibitorami korozji w płynach niskokrzepnących mogą być związki nieorganiczne lub organiczne. Dodatki organiczne w płynach niskokrzepnących przeważnie tworzą cieńsze powłoki ochronne, mimo to uznaje się, że skuteczniej zabezpieczają narażone powierzchnie niż płyny z dodatkami nieorganicznymi. W niniejszej pracy zbadano efekty na powierzchni stali pojawiające się pod wpływem płynów niskokrzepnących spełniających kluczowe wymagania normatywne. Zastosowano mikroskopowe obrazowanie, które pozwoliło zidentyfikować zmiany powierzchni niewidoczne w skali makro. Badania miały na celu ocenę potencjału płynów niskokrzepnących do silników spalinowych w perspektywie ich wykorzystania w instalacjach grzewczo-chłodząco-wentylacyjnych.
2
Content available NSS test of structural steel corrosion
EN
Corrosion of structural steel represents one of the most significant degradation effects on the reliability and durability of steel bridges. Relevant data needed for good protection of steel structures can only be reliably derived from long-term measurements. For acceleration of corrosion process, measurement in the corrosion chambers can be utilised. The article summarized the results of experimental measurements of corrosion losses carried out on 30 specimens of structural steel corrosion in the test chamber during 140 days. The environment in the chamber simulates the conditions in which, generally, several-day period in the chamber corresponds to either months or even years of outdoor exploitation. Discussion focused on the results interpretation to corrosion progress in real conditions is given, as well. The obtained measurement data should be used to refine the input data for corrosion maps in Slovakia. The presented results are part of a research project focused on measuring corrosive losses of structural steel in situ and as well as in laboratory conditions.
EN
The following article discusses the problem of durability of girders made of structural steel S355 affected by corrosion. It presents the Polish procedure for calculating the time between failures of steel elements of bridge and durability factors necessary to estimate the impact of corrosion on the durability of steel road bridges. According to the presented procedure, two real bridges of steel structure were analysed. The bridges selected for analysis are located in extremely different corrosive environments in Poland. This bridges were built in different areas of the country which are characterized by different (mountain, urban) aggressiveness of the environment. The objects of the analysis differ in terms of corrosion type occurring on the bearing system. Their age is also different which has a significant impact on their safety. The results obtained allowed to determine the time when, with the existing corrosion damage, failures may occur.
PL
Przeprowadzono badania wpływu zawartości chlorków w cemencie hutniczym na właściwości ochronne otuliny betonowej. Stosowano cement zawierający od 0,085 do 0,5% jonów chlorkowych. Właściwości ochronne otuliny betonowej oceniono na podstawie anodowych krzywych polaryzacji stali w betonie po różnych czasach dojrzewania oraz po karbonatyzacji betonu. Stwierdzono brak wpływu zawartości chlorków w cemencie hutniczym, w badanym zakresie wartości, na korozję stalowego zbrojenia betonu. Otulina nieskarbonatyzowana, nawet przy najwyższej stosowanej zawartości chlorków, wykazała dobre właściwości ochronne w stosunku do zbrojenia. Zbrojenie w otulinie betonowej skarbonatyzowanej ulegało korozji aktywnej.
EN
The investigation of the effect of chloride content in blast furnace slag cement on the protective properties of concrete cover of steel was carried out. Cement containing from 0.085 to 0.5% chloride ion was used. The protective properties of the concreto cover were evaluated based on anodic polarization curves of steel in the concrete after different periods of concrete hardening and carbonation. No effect of chloride content in the cement, over a range of tested values, on the corrosion of steel reinforcement was found. Noncarbonated cover, even at the highest chloride content used, showed a good protection properties for reinforcement. The active corrosion of steel reinforcement in the carbonated concrete was observed.
PL
W artykule opisano badania wpływu czasu na zachowanie ocynkowanej stali zbro-jeniowej w kontakcie z syntetyczną cieczą porową betonu. Przedmiotem badań był gładki pręt zbrojeniowy ze stali gatunku St3S. Pręt poddano procesowi cynkowania ogniowego. Uzyskano powłokę gr. 100 mm. Wyciętą z ocynkowanego pręta próbkę stali zanurzono w roztworze cieczy porowej o pH = 13,4. W ciągu 4 godzin od zanurzenia próbki w roztworze wykonano w układzie trójelektrodowym serię 6 pomiarów metodą elektrochemicznej spektroskopii impedancyjnej.
EN
The article describes a study of the impact of time on the behavior of galvanized reinforcing steel in contact with synthetic concrete pore solution. The object of study was a smooth rebar made of St3S steel grade. Rebar was hot-dip galvanized to obtain coating thickness of 100 mm. A steel sample cut off the galvanized rebar was dipped in synthetic concrete pore solution with pH= 13.4. Within 4 hours of immersion of the sample in the solution, a series of 6 measurements were taken, using electrochemical impedance spectroscopy in a three-electrode system.
EN
Basing on polarization measurements one estimated the course of corrosion processes for reinforcement of concrete samples exposed to the cyclic influence of 3% NaCl solution. It was found that concrete containing 30% of fluidized bed boiler ash in relation to the mass of cement protected steel reinforcement against chloride corrosion better than Portland cement concrete.
EN
This paper presents the results of corrosion resistance tests of structural carbon St3S steel, low alloyed steel containing 5 or 9% Cr and stainless steel H18N11M3 in thermal water saturated with CO2 of Skierniewice thermal installation. The study was conducted using polarization techniques (OCP, LSV) and impedance spectroscopy (EIS). Corrosion of structural steel is determined by cathodic reduction of carbonic acid, a direct product of corrosion is a surface layer of magnetite. In case of high saturation of surface with CO2, diffusion control changes into mixed diffusion-capacitive control associated with the formation of corrosion products layer. Low alloyed chromium steel (P5) covers with more corrosion-resistant layer of corrosion products, and the corrosion rate is controlled by the barrier properties of this film (anodic control). The increase in the content of chromium in low-and medium-chromium steels stimulates the barrier properties of the anodic film. These layers observed at P5 and P91 steel are thick layers of sedimentary type. Proper passivation occurs only in the case of stainless steel H18N11M3.
PL
W pracy przedstawiono wyniki badań odporności korozyjnej węglowej stali konstrukcyjnej St3S, niskostopowych stali zawierających 5 i 9% chromu oraz stali nierdzewnej H18N11M3 w instalacji termalnej Skierniewice w wodzie termalnej nasycanej CO2. Badania prowadzono za pomocą technik polaryzacyjnych (OCP, LSV) oraz spektroskopii impedancyjnej (EIS). Korozja stali konstrukcyjnych determinowana jest katodową redukcją kwasu węglowego, a bezpośrednim produktem korozji jest powierzchniowa warstewka magnetytu. W przypadku dużego nasycenia powierzchni stali w CO2 kontrola dyfuzyjna przechodzi w kontrolę mieszaną dyfuzyjno-pojemnościową związaną z tworzeniem się warstewki produktów korozji. Niskostopowa stal chromowa (P5) tworzy bardziej odporną na korozję warstewkę produktów korozji, a szybkość korozji tej stali kontrolowana jest właściwościami barierowymi tej warstewki (kontrola anodowa). Wzrost zawartości chromu w stalach nisko- i średniochromowych stymuluje właściwości barierowe warstewki anodowej. Warstewki te obserwowane na stali P5 i P91 są grubymi warstewkami typu osadowego. Właściwa pasywacja pojawia się dopiero w przypadku stali H18N11M3.
PL
Beton z racji swej zasadowości (wartość współczynnika pH ? 12) stanowi warstwę ochronną stali zbrojeniowej przed korozją. W wyniku szkodliwego wpływu wody, dwutlenku węgla oraz soli, odczyn alkaiczny ulega obniżeniu. Przy wartości pH=10 (11) beton wykazuje tylko niewielką lub w ogóle żadną aktywność korozyjną stali zbrojeniowej. Zwiększenie się objętości korodującej stali zbrojeniowej (pęcznienie) w następstwie utraty alkaiczności betonu nazywamy karbonatyzacją betonu. W oparciu o wyniki badań stopnia karbonatyzacji betonu elementów żelbetowych zbiornika retencyjnego do głębokości 2,5 cm stwierdzono początek procesu karbonatyzacji szczególnie w strefie falowania wody oraz częściowo w strefie powyżej maksymalnego poziomu piętrzenia wody. Na stopień karbonatyzacji elementów żelbetowych budowli hydrotechnicznych ma istotny wpływ pH wody (śr. pH wody zretencjonowanej w zbiorniku wynosiło od 7,6 - 7,9).
11
Content available remote Stal odporna na korozję w wodach termalnych
PL
Korozja stali jest jednym z głównych problemów w geotermalnych układach grzewczych ze względu na obecność rozpuszczonego CO2 i H2S w wodzie o różnym stopniu mineralizacji. W niniejszej pracy badano szybkość korozji stali w warunkach eksploatacyjnych przy zastosowaniu metody pomiaru oporu polaryzacji oraz metody grawimetrycznej. Szybkość korozji stali maleje od wartości 0,9 mm/rok do 0,02 mm/rok wraz ze wzrostem zawartości chromu od 0 do 11,5% w stali. Do praktycznego zastosowania można polecić stale chromowe z molibdenem (zawierające powyżej 5% Cr).
EN
The presence of dissolved CO2 and H2S in geothermal water is the main of corrosion problem of steel in geothermal plant. In this work the corrosion rate of steels was examined using the linear polarization resistant and gravimetric methods under industrial conditions. Rate of corrosion decreased from 0.9 mm/y to 0.02 mm/y when chromium content in steel grown to 11.5%. Surface analysis of corrosion products was examined by EDX-technique. Chromium alloyed steel (containing over 5% Cr e.g. steel P5 according ASTM A335) with molybdenum we recommended for industrial application.