Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 15

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  conducted emission
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Most automotive electronic components can cause electromagnetic interference, that can cause power electronic circuits to become unstable. As per electromagnetic compatibility (EMC) standards, these electronic circuits should meet the specifications which are not achieved under some conditions. In this paper, the conducted emissions (CEs) are generated due to the switching of a buck converter, which often occurs in automotive electronics. The noise source was found to be due to the presence of common mode currents which largely affects the performance of EMC. Two types of filtering techniques were analysed and designed, and the results were compared to find an effective filtering solution to mitigate the effects of CE due to a common mode noise for the frequency range from 150 kHz to 108 MHz according to the International Special Committee on Radio Interference (CISPR25) standard. The capacitive and parasitic impedance were calculated and then used in the simulation. Finally, the simulated and measured results are presented. The noise level can be minimized by as much as 50 dB, which is an efficient noise reduction value.
PL
W artykule przedstawiono problemy związane z pomiarem zaburzeń przewodzonych świetlówek kompaktowych, przy zasilaniu układu pomiarowego napięciem odkształconym. Przedstawiono wyniki badań emisji świetlówek przy napięciu zasilającym odkształconym w granicach dopuszczonych przez normy. Stwierdzono wpływ odkształcenia na wyniki. Zaproponowano postępowanie pozwalające na przeprowadzenie jednoznacznej oceny świetlówek.
EN
The paper presents problems related to the conducted emissions measurement of compact fluorescent lamps when the measuring system is supplied with distorted voltage. The results of tests on the emission of fluorescent lamps at the supply voltage distorted within the limits permitted by the standards are presented. The influence of deformation on the results was found. A procedure has been proposed that would allow an unambiguous assessment of fluorescent lamps.
PL
W artykule przedstawiono charakterystykę stanowiska pomiarowego do badania emisji elektromagnetycznych zaburzeń przewodzonych na portach zasilających EUT. Zaprezentowano metodykę pomiarową, dopuszczalne wartości elektromagnetycznych zaburzeń przewodzonych wg normy PN-EN 50121-3-2 i PN-EN 50121-4. W artykule omówiono wyniki z przeprowadzonych pomiarów oraz zaproponowano metodę eliminacji zakłóceń na porcie wejściowym 24V DC centrali ppoż.
EN
The paper presents the characteristics of the measurement stand for testing the emission of electromagnetic disturbances conducted on EUT ports. Methodology of measurement, acceptable electromagnetic values of conducted disturbances according to PN-EN 50121-3-2 and PN-EN 50121-4 were presented. The article discusses the results of the measurements carried out and the method of interference elimination on the 24V DC input port of the fire protection centre was proposed.
PL
W artykule przedstawiono opis stanowiska pomiarowego do badania emisji elektromagnetycznych zaburzeń przewodzonych na portach zasilających EUT. Zaprezentowano metodykę pomiarową, dopuszczalne wartości elektromagnetycznych zaburzeń przewodzonych wg normy PN-EN 50121-3-2 i PN-EN 50121-4. W artykule omówiono wyniki z przeprowadzonych pomiarów oraz zaproponowano metodę eliminacji zakłóceń na porcie wejściowym 24V DC centrali alarmowej.
EN
The article presents the study of conducted disturbance emission, which was subjected to the alarm control panel on the (+, -) 24V DC power supply ports and the method of elimination of electromagnetic interferences. The measurements were carried out in an accredited testing laboratory on a measurement stand with a standardized configuration of equipment in accordance with the applicable standards in the field of electromagnetic compatibility. During the measurements, exceedances of the limit value at the power terminals were observed. Appropriate steps have been taken to reduce the interference levels by using an appropriate anti-interference filter inside the control panel. Installing the filter in accordance with the manufacturer's instructions allowed to obtain the expected results. The article presents the effects of research in the form of electromagnetic characteristics of conductive disturbances as a function of frequencies recorded on the measuring device.
5
EN
In this work, a low cost EMC – Electromagnetic Compatibility pre-compliance board, based on the conducted emission technique, is proposed as an option to analyze electronic devices used in telecommunications and smart grid network enviroments. In general, as the IC is the major responsible of unintentional emissions and coupling, some specific pre-compliance setup tests are employed to analyze these detrimental effects to the system as a whole. Therefore, an EMC Pre-Compliance Board was designed and built to operate from 150 KHz to 30 MHz. Simulated and experimental results are compared to validate the test setup.
PL
W pracy przedstawiono prosty układ umożliwiający testowanie i poprawę elektrokompatybilności urządzeń telekomunikacyjnych I wyposażenia sieci smart grid. Układ pracuje w zakresie częstotliwości 150 kHz – 30 MHz.
EN
In this paper the basic mechanisms behind conducted emission generation in switch mode power supplies are analyzed. For the analyses a buck converter circuit is used. Separate equivalent models are introduced for differential mode and for common mode noise and the main parameters influencing the emission levels for both modes are identified. A detailed evaluation is performed to show which part of the emission spectrum is affected by a given parameter. Simulation in Matlab is performed to visualize the effect of these parameters on the spectrum. The results of theoretical analysis and simulation are verified experimentally through bench measurements performed on a buck converter.
PL
W artykule przeanalizowano podstawowe mechanizmy powstawania emisji przewodzonej w przetwornicach impulsowych. Do analiz użyty został układ przetwornicy obniżającej napięcie. Wprowadzone zostały osobne układy zastępcze dla składowej różnicowej i składowej wspólnej, a następnie główne parametry wpływające na poziom emisji dla obydwu składowych zostały zidentyfikowane. Przeprowadzona została szczegółowa analiza pokazująca na którą część wyemitowanego widma wpływa dany parametr. W celu zobrazowania wpływu tych parametrów na widmo emisji układy przesymulowano w środowisku Matlab. Rezultaty analizy teoretycznej i symulacji zostały zweryfikowane poprzez pomiary eksperymentalne do których użyta została przetwornica obniżająca napięcie.
7
Content available remote Kompatybilność Elektromagnetyczna urządzeń PLC
PL
W artykule przedstawiono problemy zgodności transmiterów sieciowych (urządzeń PLC) z wymaganiami stawianymi przez normy EMC dla środowiska mieszkalnego. Przedstawiono badania emisji przewodzonych wybranych transmiterów sieciowych dostępnych na rynku. W pracy skoncentrowano się głównie na rozwiązaniu problemów jakie napotykają producenci przy wprowadzaniu wyrobu na rynek.
EN
The article presents compatibility problems of transmitter adaptors (PLC devices) with fulfill the requirements of EMC standards for residential environment. In the paper, the results of conducted emissions measurements of selected transmitter adaptors have been presented. The study focused mainly on solving the problems faced by producers in order to place the product on the market.
PL
W artykule scharakteryzowano specyfikę zakłóceń elektromagnetycznych w aplikacjach kolejowych. Opisano metody analizy zaburzeń elektromagnetycznych generowanych przez pojazdy szynowe. Przykładowe wyniki analiz w dziedzinie czasu i częstotliwości porównano z wynikami analizy czasowo-częstotliwościowej, umożliwiającej identyfikację i lokalizację źródeł zaburzeń w pojazdach szynowych. Wskazano możliwe przyczyny zmian poziomów zaburzeń generowanych przez pojazdy szynowe w czasie eksploatacji.
EN
The paper presents the specific character of electromagnetic interference in railway applications. Methods of analysis of electromagnetic disturbances generated by track vehicles have been described. Exemplary results of analyses in time and frequency domain are compared to the results of time – frequency analysis which enable identification and the localization of disturbances sources in track vehicles. The paper indicates possible reasons of changes of levels of generated disturbances by track vehicles in their life cycle.
EN
The article presents the standards harmonized with the EMC and LVD directives, and procedures leading to the fulfilment of these requirements when designing prototype, research devices. It describes the methods of limiting interferences conducted to the power supply network and ensuring proper impedance grounding. This article also shows the necessity to analyse all the problems which may arise in connection with the EMC and LVD directives at the design stage as well as the need to conduct the designers’ testing during the construction of equipment.
PL
W artykule przedstawiono wymagania, jakie są zawarte w normach zharmonizowanych z dyrektywami EMC oraz LVD, oraz drogi prowadzące do spełnienia tych wymogów w aspekcie projektowania prototypowych urządzeń badawczych. Opisano sposoby eliminacji zakłóceń przewodzonych do sieci zasilającej oraz zapewnienia właściwej impedancji uziemienia. Uzasadniono konieczność przeanalizowania na etapie projektowania problemów wynikających z Dyrektyw EMC i LVD oraz słuszność przeprowadzania badań konstruktorskich z powyższych dyrektyw w trakcie budowy urządzeń.
PL
Przedstawiono wyniki - przeprowadzonych w zakładowym laboratorium EMC - pomiarów emisji przewodowej obwodów zasilania instalacji alarmowych na zgodność z wymaganiami normy EN 55022 (dla urządzeń klasy B), w których nastąpiła zmiana zasilacza AC/AC względem zalecanej przez producenta konfiguracji. Uzyskane wyniki wskazują że stosunkowo niewielkie odstępstwa od zalecanej konfiguracji instalacji skutkują przekroczeniem poziomów emisji przewodowej W takich przypadkach cała instalacja nie będzie spełniała wymagań zasadniczych określonych w dyrektywie EMC w zakresie emisji przewodowej.
EN
The paper presents the results of the conducted emission made in- factory EMC test laboratory. The conducted emission was measurement on wired power circuit alarm systems for compliance with the requirements of EN 55022 (Class B) in which a change power supply AC / AC recommended by the manufacturer's configuration. The results indicate that a relatively small deviation from the recommended system configuration results in conducted emissions exceeding the limit. In such cases, the whole system fails to meet the essential requirements set out in the EMC Directive for emissions.
PL
W artykule przedstawiono metodykę badań, układy pomiarowe i wyniki przeprowadzo-nych analiz dotyczących pracy separacyjnego transformatora przeciwszumowego w warunkach niskiej jakości energii elektrycznej i transformacji odkształconego prądu i napięcia o częstotliwości podstawowej 50 Hz i zadanym udziale wyższych harmonicznych. Wyniki pomiarów wskazują, że badany transformator, w analizowanych warunkach, powoduje dodatkowy wzrost zaburzeń przewodzonych, w efekcie czego napięcie wtórne jest bardziej odkształcone niż pierwotne.
EN
The paper presents the research methodology, measurement systems, and the results of analysis of the Noise Protection Transformer operation in conditions of low power quality and transformation of distorted current and voltage of the fundamental frequency of 50 Hz and a specified content of the higher harmonics. The measurement results indicate that tested transformer in analyzed conditions cause additional increase of the conductive disturbances level and as a result secondary voltage is more distorted than the supplying voltage from the power network.
12
Content available Emisja zaburzeń przewodzonych zasilaczy impulsowych
PL
Artykuł prezentuje wyniki pomiarów emisji zaburzeń przewodzonych w obwodzie zasilania prototypu specjalizowanego zasilacza impulsowego przeznaczonego do ładowania baterii akumulatorów. Na początku artykułu opisano stanowisko i układ pomiarowy wraz z aparaturą. W dalszej części podane są wyniki pomiarów, po czym opisano sposób redukcji poziomu emitowanych zaburzeń na przyłączu zasilania do poziomu akceptowalnego przez normę [2].
EN
This paper presents the results of conducted emission measurements disturbances at the mains port of switching power supplies designed to charge the battery pack. At the beginning of this paper describes conducted disturbances measurements set-up. In the next are measurement results, and describes methods reduce the level of disturbance at the mains port to an acceptable level by the standard [2].
PL
Przedstawiono wyniki pracy nad indukcyjnym systemem grzewczym, w którym w szczególności uwzględniono problemy minimalizacji zaburzeń elektromagnetycznych wprowadzanych w czasie pracy do sieci zasilającej. W pracy przedstawiono i opisano zastosowany układ indukcyjnego systemu grzejnego oraz przedstawiono uzyskane wyniki badań rozwijanej konstrukcji i zalecenia konstrukcyjne.
EN
The results are presents of work on the induction heating system, which in particular includes the minimization problems of electromagnetic disturbances introduced during work to the mains. The paper presents and describes used the system and presents the results of research and some construction recommendations.
PL
Artykuł dotyczy problemów kompatybilności elektromagnetycznej współczesnych urządzeń informatycznych. Szczególną uwagę zwrócono na emisje niepożądane, które są produktem ubocznym, wytwarzanym w sposób niezamierzony podczas realizacji podstawowych funkcji urządzenia. W artykule przedstawiono metodologię pomiaru emisyjności przewodzonej na zaciskach zasilania urządzeń informatycznych zgodnie z normą PN-EN 55022:2006 w zakresie częstotliwości 0,15...30 MHz oraz metodologię pomiaru emisyjności promieniowanej urządzeń informatycznych zgodnie z normą PN-EN 55022:2006 w zakresie częstotliwości od 30 MHz do 6000 MHz. Zaprezentowano również wyniki pomiarów przeprowadzonych na określonej liczbie próbek składających się z jednostek centralnych PC wraz z klawiaturami oraz myszami, produkowanych w latach 2007-2009 oraz dokonano ich analizy.
EN
The article concerns problems of electromagnetic compatibility of contemporary IT devices. Particular attention was paid to undesirable emissions, which are by-products generated unintentionally during realization of basic functions of device. In the article the methodology of measuring conducted emission on supply terminals of IT devices according to he PN-EN 55022:2006 standard in the frequency range from 0.15 MHz to 30 MHz has been presented as well as the methodology of measuring radiated emissivity of IT devices in accordance with the norm: PN-EN 55022:2006 in the frequency range from 30 MHz to 6000 MHz. Also the results of measurements conducted on particular number of central processing units have been demonstrated along with key-boards and mice produced in the years 2007-2009 and next their analysis has been made.
15
PL
Celem niniejszego artykułu było opracowanie narzędzia do obserwacji charakteru zaburzeń przewodzonych emitowanych przez badane urządzenia, przy wykorzystaniu wyjścia częstotliwości pośredniej odbiornika pomiarowego. Zadanie to zostało zrealizowane przy wykorzystaniu graficznego środowiska programowania LabView.
EN
The aim of this work was to create an application dedicated to analyze the character of conducted disturbances by use of intermediate frequency output of the receiver. To perform it the LabView programming environment was chosen – a versatile tool with a graphical programming language.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.