Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 23

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  combined heat and power (CHP)
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
Content available remote The laboratory test stand of the ORC micro power plant
EN
The article presents the design and implementation of the laboratory test stand of the micro power plant with an Organic Rankine Cycle (ORC). The test stand was created to research different constructions of micro-turbines operating on a low-boiling agent. The electric power of these micro-turbines is 2-3 [kW]. There are measuring sensors connected to the test stand, which are necessary to collect information about the work of the whole ORC system. This laboratory test stand was built in the Szewalski Institute of Fluid Flow Machinery in Gdansk. The research on the newly constructed test stand were performed and some of the results are shown in this article.
2
Content available remote Low-power turbines for small ORC applications
EN
A possibility of exploiting wasted heat and converting it into electric energy by means of different energy systems becomes more and more popular. The ORC system is one of the ways for small applications, for example, to recover waste heat from engine exhaust gases. The selection of an adequate design of the machine is a key factor to maximize efficiency of the ORC. This paper presents small turbines for power generation applications with particular attention focuses on the progress observed in recent years.
3
Content available remote Gaz składowiskowy jako źródło energii
PL
W artykule przedstawiono polskie doświadczenia związane z energetycznym wykorzystaniem gazu składowiskowego, który zaliczany jest do odnawialnych źródeł energii (OZE). Znaczący wpływ na rozwój rynku zagospodarowania biogazu powstającego na składowiskach odpadów komunalnych miał wprowadzony w Polsce w 2005 roku system certyfikacji energii, który w bezpośredni sposób wspiera finansowo inwestycje polegające na wykorzystaniu gazu składowiskowego do produkcji energii. Ze względu na ustawowe ograniczenia dotyczące ilości materii organicznej kierowanej na składowiska, moc zainstalowana na nich obecnie będzie, według najlepszego scenariusza, utrzymywała się w kolejnych latach na niezmienionym poziomie. W dłuższej perspektywie – zmniejszająca się z roku na rok ilość wytwarzanego przez składowiska biogazu skutkować będzie spadkiem zainstalowanej mocy.
EN
The article presents Polish experience connected with energy projects using landfill gas which belongs to the Renewable Energy Sources (RES). The system of certification, introduced in 2005, which directly, financially supports investment for the usage of landfill gas for energy projects, has had a significant impact on the landfill gas for energy projects development in Poland. Due to the statutory limits set on the amount of organic matter directed to landfills, the power capacity currently installed in landfills will be, according to the best scenario, maintained at the same level in subsequent years. Since the amount of biogas produced by the landfill tends to decrease year after year the amount of biogas produced by the landfill will result in a decrease of the installed power capacity.
PL
W artykule przedstawiono charakterystykę eksploatacyjną układów kogeneracyjnych zasilanych biogazem i gazem ziemnym, zainstalowanych w komunalnej oczyszczalni ścieków. Na podstawie wyników uzyskanych w wybranym roku eksploatacji pokazano zmienność zapotrzebowania i struktury bilansu energii oczyszczalni w poszczególnych miesiącach roku. Wykazano wpływ gospodarki osadowej na wskaźniki zapotrzebowania na energię elektryczną i ciepło. Porównano udziały energii skojarzonej w bilansie energetycznym oczyszczalni stosującej rolnicze wykorzystanie przefermentowanego osadu oraz prowadzącej suszenie osadu przeznaczonego do termicznej utylizacji.
EN
The paper presents operational output of biogas driven and natural gas driven cogeneration units installed at the municipal wastewater treatment plant. The results obtained during the selected year of operation depict variability of energy demand and structure in each month of the year. The paper indicates the influence of sludge disposal on unit electric energy and heat consumption. It compares the participation of combined heat and power in energy balance of the wastewater plant employing agricultural utilization of digested sludge or sludge drying for the purpose of thermal utilization.
EN
The study presents issues concerning technical solutions of combined systems of energy generation which can be used primarily in low-level power plants, installed in various types of public utility sites. A detailed description is given of selected ways of powering combined energy generation systems, presenting conceptual outlines of their operation and information on their advantages, disadvantages and applications. The following systems are introduced: gas-steam, back-pressure steam turbine, extraction-condensing steam turbine, gas turbine, gas microturbine, Stirling engine, fuel cells and internal combustion piston engine. Moreover, the study addresses economic aspects of energy generation in combined systems, discussing different methodologies of cost calculation, including the one used by the European Union. The article also gives a detailed review of piston engine combined-system aggregates available in the Polish market. Type series of associated systems designed for low-power appliances are shown, produced by Polish and foreign companies such as Viessmann, Centrum Elektroniki Stosowanej CES, H. Cegielski – Poznań, KWE Technika Energetyczna, TEDOM Poland or the EPS System.
EN
In this article issues concernig the possibility of nuclear power plant (NPP) operation also as a source of heat, which means combined heat and power production, have been described. CHP work is possible and profitable only in those areas where high thermal power demand occurs, which means near city agglomerations such as Warsaw or the Tri-City. Two levels of thermal power delivered to the heating system have been considered. Preliminary technical and economic studies regarding NPP location by Żarnowiec Lake have confirmed the NPP potential to work as a primary source of heat in the heating network system, which would feed the regions of Wejherowo and Gdynia.
PL
Autorzy przedstawili w artykule zagadnienia związane z możliwością pracy elektrowni jądrowej (EJ) również w charakterze źródła ciepła, a więc w warunkach skojarzonego wytwarzania energii elektrycznej oraz ciepła. Praca w skojarzeniu jest możliwa i opłacalna tylko w tych rejonach, w których występuje duże zapotrzebowanie na moc cieplną, a więc w pobliżu aglomeracji miejskich, takich jak np. aglomeracja warszawska czy trójmiejska. Rozpatrzono dwa poziomy mocy cieplnych oddawanych do systemów ciepłowniczych. Wstępne badania techniczne i ekonomiczne dla lokalizacji elektrowni jądrowej nad Jeziorem Żarnowieckim potwierdziły potencjalną możliwość pracy EJ w charakterze podstawowego źródła ciepła w systemie ciepłowniczym, który zasilałby rejon Wejherowa i Gdyni.
PL
W niniejszym artykule przedstawiono zagadnienia związane z możliwością pracy elektrowni jądrowej (EJ) również w charakterze źródła ciepła, a więc w warunkach skojarzonego wytwarzania energii elektrycznej oraz ciepła. Rozpatrzono dwa poziomy mocy cieplnych oddawanych do systemów ciepłowniczych. Przeprowadzone wstępnie badania techniczne i ekonomiczne dla lokalizacji elektrowni jądrowej nad Jeziorem Żarnowieckim potwierdziły potencjalną możliwość pracy EJ w charakterze podstawowego źródła ciepła w systemie ciepłowniczym, który zasilałby rejon Wejherowa i Gdyni.
EN
In this article issues concernig possibility of nuclear power plant's operation also as a source of heat, which means combined heat and power production, have been described. Two levels of thermal power delivered to the heating system have been considered. Preliminary technical and economic studies regarding nuclear power plant's location by Żarnowieckie Lake have confirmed the nuclear power plant's potential to work as a primary source of heat in the heating system, which would feed the regions of Wejherowo and Gdynia.
EN
The paper presents results of analysis of failures of high power induction motors installed in utility power plants and combined heat and power plants.
PL
Przedstawiono wyniki analizy uszkodzeń silników indukcyjnych dużej mocy prądu przemiennego, zainstalowanych w elektrowniach zawodowych i elektrociepłowniach.
EN
European Union (EU) strategy focuses on limiting the industrial impact on the climate change and increasing EU's energy security. Despite the directive implementation has progressed more slowly than originally planned, member states have introduced support mechanisms to promote CHP technologies. One of the main concepts of CHP generation stays in compliance with EU strategies, which aim to reduce the carbon emission and increase the energy efficiency and sustainability of the European economy. The share of CHP power generation varies considerably across the EU member states, ranging from 49.2% in Denmark to 0% in Malta, the value for Poland is 17.6%. Technical potential for CHP development in Poland remains high. Despite relatively high market share of CHP systems (by EU standards), many new systems may still be constructed, as a lot of heat demand is still covered by heat-only generation systems. This analysis showed that the potential of heat demand in households in urban areas without the CHP is around 1 560 MW, including 570 MW in small scale systems (1-2 MWe). This evaluation is still conservative, as it assumes only potential for systems operating as base load sources all over the year. Moreover it doesn’t take into account existing CHP systems which potentially may be considered as new investment sites. Results indicate that Polish CHP generation market requires support actions which will lead to energy in fuel savings.
PL
Strategia Unii Europejskiej skupia się na ograniczaniu wpływu przemysłu na zmiany klimatu oraz na wzroście bezpieczeństwa energetycznego wspólnoty. Pomimo wolniejszego od zakładanego tempa wdrażania dyrektyw Parlamentu Europejskiego państwa członkowskie stopniowo wdrażają mechanizmy wsparcia kogeneracji energii elektrycznej i ciepła. Realizacja planu wzrostu udziału produkcji energii elektrycznej w kogeneracji przyczynia się do wypełniania celów redukcji emisji dwutlenku węgla, wzrostu efektywności energetycznej oraz zrównoważonego rozwoju gospodarki europejskiej. Udział kogeneracji w poszczególnych państwach członkowskich jest silnie zróżnicowany: od 49,2% w Danii do 0% na Malcie, w Polsce wartość ta wynosi 17,6%. Potencjał techniczny dla rozwoju rynku kogeneracji w Polsce pozostaje wysoki. Pomimo dość wysokiego udziału kogeneracji w rynku energii elektrycznej, w porównaniu do średniej UE27 wiele nowych układów tego typu można jeszcze zbudować, ponieważ duża część zapotrzebowania na ciepło jest zaspokajana z lokalnych ciepłowni. W tej analizie określono potencjał rynku kogeneracji w Polsce na około 1560 MW, w tym około 570 MW w instalacjach o wielkości od 1 do 2 MW. Ta ocena potencjału rynku jest jednak dość konserwatywna ponieważ zakłada rozwiązanie kogeneracyjne dla ciepłowni wyłącznie w podstawie zużycia ciepła, na poziomie zapotrzebowania na ciepłą wodę użytkową. Ponadto nie uwzględnia tej części istniejących układów kogeneracyjnych, które także mogą być miejscem na nowe inwestycje. Wyniki wskazują na to, że wsparcie polskiego systemu kogeneracji będzie skutkowało oszczędnościami energii pierwotnej.
EN
The paper presents thermodynamic analyse of the potential of adopting a power unit to combined heat and power generation. The analyse is based on a mathematical model of a 370MW power unit operating with the Polish Power System. The calculation are performed for the minimum operation of the power units with the capacity from 180 MW and the maximum capacity of 380 MW. Annual heat load duration curve, annual qualitative regulation chart and the Stodola–Flügel turbine passage equation are applied to calculate saturation temperature and steam extraction to heat exchangers. The analyse shows that it is possible to supply a heat demand of medium sized town in every operating condition of the power unit adopted to cogeneration.
PL
W pracy przedstawiono termodynamiczną analizę możliwości przystosowania bloku energetycznego do skojarzonego wytwarzania ciepła i elektryczności. Analizę oparto na modelu matematycznym bloku energetycznego 370 MW pracującego w Polskim Systemie Elektroenergetycznym. Obliczenia przeprowadzono dla pracy z mocą minimalną 180 MW i maksymalną 380 MW. Do obliczeń temperatury nasycenia pary i jej poboru do wymienników ciepłowniczych wykorzystano roczny uporządkowany wykres zapotrzebowania na moc cieplną, wykres regulacji jakościowej oraz równanie przelotowości turbiny Stodoli-Flügla. Analiza pokazała, że możliwe jest zaspokojenie potrzeb cieplnych średniej wielkości miasta przez uciepłowniony blok energetyczny pracujący zgodnie z wymogami KSE.
PL
W artykule przedstawiono metodę opłacalnego zastosowania gazu ziemnego w ciepłowniach węglowych. Zasadnicza idea polega na wprowadzeniu układów z silnikami gazowymi do skojarzonego wytwarzania energii elektrycznej i ciepła. Przeprowadzono obliczenia na podstawie danych rzeczywistego systemu ciepłowniczego. Średnia moc cieplna latem wynosi około 5,77 MW. Udział ciepłej wody użytkowej w systemie ciepłowniczym wynosi około 7%. Dzięki dysponowaniu danymi agregatów firmy Jenbacher, analizy wykonano z użyciem tych urządzeń. Jako kryterium optymalności przyjęto prosty czas zwrotu (SPBT - simply pay-back time). Przeprowadzono obliczenia dla 29 wariantów pracy zestawów agregatów o jednakowych wielkościach. Najlepszy wariant charakteryzuje się prostym czasem zwrotu SPBT = 2 lata. Należy zastosować dwa agregaty typu ECOMAX 27 HE o mocy cieplnej 2,457 MW i mocy elektrycznej 2,679 MW. Taki rezultat wskazuje, że kierunek działań jest właściwy. Roczne zużycie gazu wynosi około 9,3 min m-7a, przy jego cenie około 1,35 zł/m3. Najkorzystniejsze rozwiązanie znajduje się w pobliżu mocy cieplnych potrzebnych latem. Pozwala to na znaczne zmniejszenie liczby analizowanych wariantów. Przy przebudowie ciepłowni węglowych na elektrociepłownie należy stosować gazowe bloki siłowniano-ciepłownicze. Należy kontynuować badania z uwzględnieniem kosztów eksploatacyjnych (serwis, amortyzacja).
EN
In the article is description the method of the profitable use of natural gas in coal-boiler stations. The fundamental idea consists in the introduetion of parley with gas-engines to the combined produetion of the power and heat. One carried out calculations on the basis given of the real district heating system. The average heat demand in summer is about 5,77 MW. The participation of the useful hot water in the district heating system is about 7%. Thanks to having at its disposal given of aggregates of the firm of Jenbacher, the analysis performed with the use of these devices. As the criterion of the optimałity one accepted the simply pay-back tirne (SPBT). One carried out calculations for 29 variants of the work of sets of aggregates about equal sizes. The best variant is characterized to simple pay-back time SPBT ~ 2 years. There belongs to apply two aggregates of the type ECOMAX 27 HE about the heat capacity 2,457 MW and the power capacity 2,679 MW. Such result indicates that the direetion of activities is proper. The annual gas consumption amounts about 9,3 millions m3, at his price about 1,35 zloty/m3. Optimum solution is found next door to necessary heat demand in summer. Permits this the considerable diminution of the number of analyzed variants. At the reconstruetion of coal-boiler stations on heat and power generating plants one ought to apply gaseous CHP. One ought to continue research with the regard of operating costses.
PL
W pracy omówiono dotychczasową, trzyletnią eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracującego od końca grudnia 2008 roku w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów zespołu CHP, liczbę rozruchów i jego dyspozycyjność, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne zespołu CHP, bilans energii elektrycznej i ciepła oczyszczalni oraz stopień pokrycia zapotrzebowania oczyszczalni na energię elektryczną i ciepło produkcją własną, jednostkowe zużycie biogazu przez zespół kogeneracyjny, prace serwisowe i awarie zespołu kogeneracyjnego oraz uzyskane efekty ekonomiczne z eksploatacji tego zespołu. Praca jest kontynuacją wcześniejszych publikacji [3, 6, 7, 8, 9] i łącznie z nimi stanowi unikatowe kompendium wiedzy dla przyszłych eksploatatorów biogazowych zespołów CHP w postaci zbioru rzeczywistych danych eksploatacyjnych, jednego z najbardziej reprezentatywnych pod względem mocy elektrycznej (ok. 0,8 MW), biogazowego zespołu kogeracyjnego eksploatowanego w krajowych oczyszczalniach ścieków.
EN
The paper discusses three years’ commercial operation to date of the Biogas Cogeneration (CHP) Set driven with the JMS 316 GS-B.LC GE JENBACHER type engine, which has been operating in the WARTA S.A. Sewage Treatment Plant of Czestochowa since the end of December 2008. The analysis covered the CHP Set’s operation and shutdown times, number of start-ups and availability, electric energy and heat generation, and average hourly electric and thermal load; the Sewage Treatment Plant’s electric energy and heat balance and the degree of coverage of its electric energy and heat demand by its own production; the unit biogas consumption by the CHP Set; the service work carried out on, and failures of the CHP Set; and the economic effects gained from the operation of the Set. The study is a continuation of the previous publications [3], [6], [7], [8], [9] and, jointly with them, constitutes a unique compendium of knowledge for future operators of CHP biogas sets in the form of a collection of actual operational data for one of the most representative biogas cogeneration sets operated in domestic sewage plants in terms of electric power (approx. 0.8 MW).
EN
The paper discusses two years' commercial operation of the biogas cogeneration set with a GE JENBACHER engine type JMS 316 GS-B.LC, which was installed at the end of December 2008 at the WARTA S.A. Waste Treatment Plant in Czestochowa. The analysis covered the time of operation and shutdowns, the number of the start-ups of the CHP set, its operation time utilization rate, the generation of electric power and heat, the average hourly electric and thermal load of the CHP set, the electrical energy balance of the WARTA S.A. Waste Treatment Plant in Czestochowa along with the degree of coverage of the Waste Treatment Plant's electrical energy and heat demand by their own production, the Waste Treatment Plant's biogas balance, unit biogas consumption by the CHP set, the servicing of the CHP set, and the economic effects achieved from the operation of the Cogeneration Set.
PL
W pracy omówiono dwuletnią eksploatację przemysłową biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC pracujacego od końca grudnia 2008 roku w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Analizowano czas pracy i postojów, liczbę rozruchów zespołu CHP, stopień jego wykorzystania, produkcję energii elektrycznej i ciepła, średnie godzinowe obciążenie elektryczne i cieplne zespołu CHP, bilans energii elektrycznej oczyszczalni i stopień pokrycia zapotrzebowania oczyszczalni na energię elektryczną i ciepło produkcją własną, bilans biogazu w oczyszczalni, jednostkowe zużycie biogazu przez zespół kogeneracyjny, serwis zespołu kogeneracyjnego oraz uzyskane efekty ekonomiczne z eksploatacji tego zespołu.
EN
The paper presents operational characteristics of start-up and shut-down of a 30kW micro Combined Heat and Power (ž-CHP) system. The main objective of the ž-CHP unit is to introduce the novel concept of a Polymeric Electrolyte Membrane Fuel Cell based CHP (ž-CHP-PEMFC) system able to supply heating (heating and sanitary water), cooling and electricity. Whereas the plant description was provided in the previous paper (Rynek Energii 5(90) 2010), the objectives of this paper are the main aspects of the start-up and shut-down procedures which were performed in situ. The plant is composed of three main units: reformer, CO oxidizer (reactor "water gas shift" and oxidation reactor - "prox"), and PEMFC. The sequence of the start-up procedure is as follows: heating up the reformer and CO oxidizer to a temperature of 700-800°C. A double-fuel burner is used to heat up the reformer. Then composition of the gas leaving the reformer is then checked. The outlet gas from the first part of the reformer (called syngas) contains about 5% CO, which is destructive for fuel cells such as PEM. The maximum acceptable level of CO in fuel for this category of fuel cell is approximately 25ppm. In the second part of the reformer, CO is reduced in catalytic reactions. This is the most difficult and time-consuming process due to the high sensitivity and inertia of the whole cycle. After adjusting some parameters, much time is needed to stabilize the process and check the results of the changes. After achieving the required CO levels in syngas, the control valve can be opened to feed the fuel cell and start production of combined heat and power.
PL
W artykule przedstawiono charakterystykę operacyjną rozruchu i odstawienia mikro elektrociepłowni (ž-CHP) o mocy elektrycznej 30kW z polimerowym ogniwem paliwowym (PEMFC). Głównym celem jednostki ž-CHP jest zabezpieczenie potrzeb termicznych (ogrzewanie oraz ciepła woda użytkowa) i elektrycznych konkretnego obiektu. Szczegółowy opis obiektu został przedstawiony w poprzednim artykule (Rynek Energii 5 (90) 2010). W niniejszym artykule zostały poruszone główne aspekty procedur rozruchu i odstawienia, które były wykonywane podczas testów obiektu. Obiekt składa się z trzech głównych zespołów: reformera parowego metanu, układu redukcji (dopalania) CO i polimerowego ogniwa paliwowego - PEMFC. Procedura rozruchu jest następująca: wygrzewanie reformera i układu dopalania CO do osiągnięcia poziomu temperatury 700-800°C za pomocą dwupaliwowego palnika. Po ustabilizowaniu się temperatury gazu wylotowego z reformera (tzw. gaz syntezowy) należy zbadać zawartość CO, która powinna wynosić około 5%. Jest to wartość, która działa niszcząco na ogniwa paliwowe, takie jak PEM. W przypadku tej kategorii ogniw paliwowych dopuszczalny poziom CO w paliwie wynosi maksymalnie ok. 25ppm. W dalszej części reformera (układzie dopalania) zmniejsza się poziom CO podczas reakcji katalitycznych. Jest to najbardziej trudny i czasochłonny proces ze względu na wysoką czułość i bezwładność całego układu. Po zmianie niektórych parametrów potrzeba dużo czasu aby proces się ustabilizował na tyle, by móc sprawdzić i ocenić skutek tej zmiany. Po osiągnięciu wymaganego poziomu CO w gazie syntezowym można otworzyć zawór zasilający ogniwo paliwowe i zacząć produkować energię elektryczną i cieplną.
PL
W artykule przedstawiono podstawowe europejskie i krajowe uwarunkowania prawne dotyczące odnawialnych źródeł energii. Uwagę skupiono na wykorzystaniu OZE, w tym głównie biomasy w Polsce. Zaprezentowano definicję biomasy, krótką charakterystykę tego paliwa oraz możliwe źródła jego pozyskania. Omówiono proces zgazowania, stosowane gazogeneratory, krótką charakterystykę i specyfikę ich działania oraz kierunki wykorzystania gazu procesowego ze szczególnym uwzględnieniem układów CHP wyposażonych w reaktory zgazowania biomasy. Szczegółowo przedstawiono i omówiono wybrane konstrukcje reaktorów przeznaczonych do zgazowania biomasy opracowane w Polsce. Porównano podstawowe parametry procesu zgazowania dla prezentowanych instalacji. Przedstawiono zalety i wady gazogeneratorów pod kątem ich eksploatacji. Przeanalizowano potencjał rynkowy biomasy w kraju z przeznaczeniem na cele energetyczne. Sprecyzowano i opisano działania, których realizacja wpłynie korzystnie na rozwój energetyki odnawialnej w Polsce.
EN
This paper presents the basic determinations of the European and national legislation concerning Renewable Energy Sources (RES). The attention was focused on the use of RES, including mainly biomass, in Poland. The definition of biomass, a short description of this fuel and the possible sources of acquisition were presented. The process of gasification and gasifiers applied were presented, and a short characteristic and specifics of their operation and directions of the use of process gas with particular emphasis on systems equipped with CHP biomass gasification reactors were described. The selected designs of reactors for biomass gasification developed in Poland were presented and discussed in details. A comparison of the basic parameters of the gasification process for the presented installations was made. Gasifiers' advantages and disadvantages at an angle of their exploitation were presented. The market potential of the biomass in Poland for energetic purposes was analyzed. The activities of which realization will influence the development of renewable energy in Poland were specified and described.
16
Content available Zgazowanie biomasy w układach małej mocy
PL
W artykule zaprezentowano główne założenia polityki energetycznej Unii Europejskiej. Szczególną uwagę zwrócono na odnawialne źródła energii. Przedstawiono biomasę jako paliwo dla układów energetycznych. Omówiono główne grupy klasyfikacji pochodzenia i źródeł biomasy stałej, a także sposoby jej konwersji na energię elektryczną oraz ciepło. Zaprezentowano podstawowe rozwiązania układów zasilanych gazem procesowym wytworzonym w procesie zgazowania. Opisano przykładowo wybrane trzy instalacje energetyczne małej mocy zintegrowane ze zgazowaniem biomasy.
EN
In this paper the main assumptions of the European Union energy policy were presented. The main attention was focused on the Renewable Energy Sources. Biomass as a fuel for the energy systems was described. The main groups of classifications of the origin and sources of solid biomass, as well as the methods of its conversion to electricity and heat were characterized. The main solutions of the systems supplied with the process gas generated in the process of gasification were presented. Three exemplary installations of low power integrated with biomass gasification were described.
PL
W artykule przedstawiono analizę możliwości współ-produkcji energii elektrycznej oraz energii cieplnej na potrzeby centralnego ogrzewania oraz ciepłej wody użytkowej w doświadczalnej mikrosiłowni hybrydowej budowanej w Instytucie Maszy Przepływowych Politechnik Łódzkiej.
EN
The paper presents analysis of abilities of an experimental micro-hybrid power plant, which is building at the Turbomachinery Institute, to cogeneration of electric power and heat energy for central heating and hot water.
EN
The paper presents a summary of twelve months 'commercial operation oj the new biogas cogeneration set with the GE JENBACHER engine, type JMS 316 GS-B.LC, which was installed at the end of December 2008 in the WARTA S.A. Waste Treatment Plant in Częstochowa. The summary of the first six months of operation of this set is discussed in reference [4].
PL
W pracy zaprezentowano podsumowanie dwunastomiesięcznej eksploatacji przemysłowej nowego biogazowego zespołu kogeneracyjnego z silnikiem GE JENBACHER typu JMS 316 GS-B.LC zainstalowanego w końcu grudnia 2008 r. w Oczyszczalni Ścieków WARTA S.A. w Częstochowie. Podsumowanie pierwszych sześciu miesięcy eksploatacji tego zespołu omówiono w [4].
EN
The present paper is the result of the author's research project no. 4 T12D 030 28 on the "Analysis of the actual technical and operational parameters of gas CHP sets" carried out by him in the years 2005-08, and financed by the Ministry of Science and Informatization in Warsaw. The primary scientific objective of the Project was to establish, compare and analyze the actual values of basic technical, operational and economic parameters for different CHP (Combined Heat and Power) sets driven by gas piston engines, operated in Poland. An analysis of the techniques of fuel gas utilization in piston engine-driven cogeneration sets, being currently used (and also likely to be used in the future), finding their application in combined energy management, has been made within the Project, and a review of the operational conditions of a dozen or so CHP sets operated in Poland, fed by biogas, mine gas from hard coal mine demethanization has been carried out. The results of this analysis have been included in the present monograph which, in addition to the review of the conditions of CHP set operation, provides conclusions that have also utility importance, and therefore can well be useful in making the optimal design of a combined energy system consisting of combustion heat- and power-generating sets.
20
Content available remote AI tool for automatic synthesis of CHP systems
EN
Inside the EU countries significant investments are expected in both the electricity production and energy transfers within the next 15 years. Such investments will need the precise decision-making processes, supported with very versatile engineering tools. The major objective of this paper is to propose an application of a new methodology to design power systems in a fully automatic way. The proposed methodology utilizes such artificial intelligence tools like genetic algorithms and expert systems.
first rewind previous Strona / 2 next fast forward last