The implementation or optimization of the coagulation process requires prior preliminary tests. Standard Jar-Test method is time-consuming, inaccurate and may not work well, especially for the waters characterized by high variability of quality parameters. Zeta Potential Isoelectric Point (IEP) analysis may give fast and precise data on the coagulant type and dose required for maintaining an efficient coagulation process. The research objects included the surface waters taken directly from the Mała Panew and Odra rivers. The zeta potential and set coagulant dose dependence was measured for each sample. Four aluminum-based coagulants with different characteristics were used in this research: aluminum sulfate (Alum), polyaluminum chloride (PAC), dialuminum chloride pantahydroxide (PACl), polyaluminum chloride hydroxide sulfate (PACS). Charge neutralization effectiveness, by means of Zeta Potential IEP analysis, was the basis for the choice of the most effective coagulant doses. The coagulation process efficacy was based on the parameters of the treated water (pH, turbidity, color, alkalinity), reduction of organic matter (Abs254, Total Organic Carbon (TOC), Dissolved Organic Carbon (DOC)) and residual aluminum contamination. The Zeta Potential utility evaluation was based on the DOC reduction.
2
Content available remote Zastosowanie wybranych koagulantów do rozdzielania zawiesin bentonitowych
PL
Przeprowadzono badania koagulacji wodnej zawiesiny bentonitowej. Badania obejmowały pomiar rozkładu wielkości cząstek, analizę chemiczną i fazową przygotowanej zawiesiny, a także określenie zależności między stężeniem zawiesiny a mętnością wraz z wizualnym przedstawieniem otrzymanych wyników. Określono związek pomiędzy dawką koagulantów i ich mieszanin a stężeniem w celu ustalenia, czy mieszanina koagulantów może być bardziej skuteczna w procesie koagulacji. Znajomość zależności między stężeniem zawiesiny a krytycznym stężeniem koagulantów dla zawiesiny bentonitowej może być pomocna przy ustalaniu krytycznego stężenia koagulantu w procesie projektowania wysokosprawnych zbiorników sedymentacyjnych lub w stacjach uzdatniania wody dla zawiesin o podobnym pochodzeniu.
EN
Two com. coagulants were used sep. as well as in mixts. (20–80% by mass) to sep. the suspensions by sedimentation. Relationships between the concn. of solids in the suspension and its turbidity as well as between the dose of coagulant (used alone or as a mixt.) and suspension concn. were det. to improve the coagulation.
PL
Ustalenie dawki optymalnej koagulantów wstępnie zhydrolizowanych wymaga określenia, czy podstawowym celem koagulacji podczas uzdatniania wody jest usunięcie mętności, czy rozpuszczonych związków organicznych. Konieczność ta wynika z faktu, iż w przypadku koagulantów spolimeryzowanych, ze względu na odmienny mechanizm usuwania obu rodzajów zanieczyszczeń, dawka optymalna dla usuwania mętności jest znacznie niższa niż dawka wymagana dla efektywnego usuwania rozpuszczonych zanieczyszczeń organicznych. Zastosowanie zwiększonej dawki umożliwiającej skuteczne usuwanie materii organicznej w oparciu o mechanizm koagulacji wymiatającej wprawdzie nie powoduje wzrostu mętności wody, tak jak to ma miejsce w przypadku reagentów hydrolizujących, jednak prowadzi do wzrostu stężenia glinu resztkowego w postaci drobnych cząstek. Jak pokazały wyniki badań pilotowych, wzrost ten był tym większy, im większy był udział polimerowych form glinu w stosowanym koagulancie.
PL
W wyniku zagęszczania osadów ściekowych, ich biologicznej stabilizacji i odwadniania powstają ciecze osadowe. Ciecze osadowe pod względem ilościowym stanowią jedynie kilka procent w ogólnym bilansie ilościowym ścieków. Jednakże ładunek zanieczyszczeń, w tym związków biogennych, jaki jest w nich zawracany do ciągu ściekowego, może stanowić nawet do kilkudziesięciu procent ogólnego ładunku dopływającego do oczyszczalni. Dla prawidłowego funkcjonowania oczyszczalni tak duży ładunek może stanowić zagrożenie. Uwzględniając to, jak ważna jest jakość cieczy osadowych, w artykule przedstawiono wpływ wybranych środków i metod kondycjonowania, takich jak: PIX 113, PIX 123, polielektrolit Zetag 8160, pole ultradźwiękowe oraz łączne ich działanie na właściwości cieczy osadowych. Surowe ciecze osadowe charakteryzowały się bardzo wysokimi stężeniami azotu amonowego (931,5-1508,9 mg N-NH4+/dm3), fosforanów (24,3-89,4 mg PO43–/dm3) oraz związków organicznych oznaczonych jako ChZT (784,0-1856,4 mg O2/dm3). Stwierdzono, że połączone działanie nieorganicznego koagulantu PIX 123 i polielektrolitu pozwoliło na zmniejszenie ilości zawiesin oraz ChZT w cieczach osadowych. W przypadku zawiesiny najlepszy stopień jej zmniejszenia uzyskano przy stosowaniu PIX-u 123. Wynosił on 53,8%. Analizując zmiany ChZT, podobne efekty uzyskano dla PIX-u 123 (43%) oraz metody łączonej (41,6%). Natomiast użycie koagulantu PIX 113 i polielektrolitu Zetag 8160 spowodowało w cieczy osadowej zwiększenie zawiesin ogólnych w odniesieniu do surowych cieczy osadowych. Działanie koagulantu PIX 113 wpłynęło na zmniejszenie wartości ChZT (90%), azotu amonowego (14,9%) i fosforanów (93,8%) w odniesieniu do surowych cieczy osadowych. Najmniej skuteczny okazał się polielektrolit Zetag 8160.
EN
As a result of the thickening, biological stabilization and dewatering of sewage sludge liquids are formed. Quantitatively sludge liquid represents only a few percent of the total volume of wastewater. However, the load of pollutants, including biogenic compounds, which is recycled into sewage path can be up to several dozen percent of the total charge flowing into the wastewater treatment plant (WWTP). For the proper functioning of the WWTP such a large load can pose a threat. The problem of the return of sludge loads is increasingly recognized and being under examination. Considering the importance of the quality of sludge liquid, the influence of selected means and conditioning methods such as PIX 113, PIX 123, polyelectrolyte Zetag 8160, ultrasound field and their effect on the properties of sludge liquids are presented in the publication. Raw sludge liquid was characterized by very high concentrations of ammonium nitrogen (931.5-1508.9 mg N-NH4+/dm3), phosphates (24.3-89.4 mg PO43/dm3) and organic compounds as COD (784.0-1856.4 mg O2/dm3). It was found that the combined action of the inorganic coagulant PIX 123 and polyelectrolyte reduced the suspensions and COD in sludge liquid. In case of suspension the best reduction was achieved when PIX 123 was applied and it was 53.8%. By analyzing COD changes similar effects were observed for PIX 123 (43.0%) and for combined method (41.6%). On the other hand, the use of coagulant PIX 113 and polyelectrolyte Zetag 8160 resulted in increased suspension in the sludge liquid in comparison to raw one. The use of PIX 113 resulted in a decrease of COD (90%), ammonium nitrogen (14.9%) and phosphates (93.8%) in comparison to raw sludge liquid. The least effective in the experiments was Zetag 8160.
EN
The paper presents the research on the possible use of inorganic coagulant and polyelectrolyte for conditioning of sonicated and non-sonicated digested sewage sludge. The digested sewage sludge from mechanical-biological wastewater treatment was analyzed. The effect of PIX 123 and polyelectrolyte Zetag 8160 and their combined effect on sonicated and nonsonicated sludge was determined. Dosing of coagulant to sludge does not create large and durable flocks that can be effectively separated by thickening or dewatering. Then, a good preconditions for creating strong flocs, obtaining a clear effluent, and improving the degree of sludge dewatering are formed. However, it requires to use a suitable polyelectrolyte after coagulation. For sludge samples the following tests were performed: capillary suction time, vacuum filtration, pressure filtration and sludge structure was observed. The suspension and COD content in the sludge liquids were also analyzed. For non-sonicated sludge prepared with Zetag 8160 or PIX 123 a better effect of the CSK decrease was obtained for Zetag 8160. For sonicated sludge PIX 123 was significantly more effective. Both the dose and the chemical used, as well as the sonication time, have a great impact on sludge structure transformation. The applied doses of PIX 123 and Zetag 8160 increased the degree of sludge dewatering, and the combined effect of ultrasonic field, PIX 123 and Zetag 8160 decreased the suspension and COD content in sludge liquids.
PL
Analizie poddano przefermentowane osady ściekowe pochodzące z mechaniczno-biologicznej oczyszczalni ścieków. W badaniach określono wpływ koagulantu PIX 123 i polielektrolitu Zetag 8160 oraz łącznego działania tych dwóch związków chemicznych na nienadźwiękawiane i nadźwiękawiane, przefermentowane osady. Dozowanie koagulantu do osadów ściekowych nie powoduje tworzenia się dużych i trwałych flokuł, które można skutecznie oddzielić w procesach zagęszczania czy odwadniania. Tworzą się za to dobre wstępne warunki do powstania silnych kłaczków, poprawy stopnia odwadniania osadów oraz otrzymania klarownego odcieku. Warunkiem jest zastosowanie po koagulancie odpowiedniego polielektrolitu. Dla osadów ściekowych wykonano następujące badania: czasu ssania kapilarnego, filtracji próżniowej, filtracji ciśnieniowej, a także obserwowano ich strukturę. Analizowano również zawartość zawiesiny i ChZT w wodzie nadosadowej. W przypadku osadów nienadźwiękawianych preparowanych Zetagiem 8160 lub PIX 123 lepszy efekt spadku wartości CSK uzyskano dla Zetagu 8160. Natomiast w przypadku osadów nadźwiękawianych zdecydowanie skuteczniejszy okazał się PIX 123. Zarówno dawka, jak i rodzaj zastosowanych środków chemicznych, a także czas sonifikacji mają wpływ na procesy zachodzące w badanych osadach. Zastosowane dawki PIX 123 i Zetagu 8160 wpłynęły na zwiększenie stopnia odwodnienia osadów. Ponadto łączne działanie pola ultradźwiękowego, PIX 123 i Zetagu 8160 pozwoliło na zmniejszenie zawartości zawiesin i ChZT w wodach nadosadowych.
EN
The quality of sludge liquids produced in the processes of mechanical dewatering of sludge depends on the stabilization technology and the kind of device, its proper operation, and an appropriate choice of conditioning chemicals. The article presents the impact of selected conditioning chemicals and methods, such as: PIX 113, PIX 123, Zetag 8160 polyelectrolyte, ultrasonic field, and their combined effect on the properties of sludge liquids. crude sludge liquids were characterized by high concentrations of ammonium nitrogen (931–1,508.9 mg N-NH4 +/dm3), phosphates (24.3–89.4 mg PO4 3–/dm3) and organic compounds referred to as COD (784–1,856 mg O2/dm3). It was found that the combined effect of inorganic coagulant PIX 123 and polyelectrolyte allowed the reduction of suspended solids and COD in sludge liquids. In the case of suspension, the highest reduction (53.8%) was obtained when using PIX 123. With regard to the changes of COD, similar effects were obtained for PIX 123 (43%) and the combined method (41.6%). The use of the PIX 113 coagulant and Zetag 8160 polyelectrolyte increased the ratio of total suspended solids in the sludge liquids in relation to crude sludge liquids. The PIX 113 coagulant led to reducing the values of COD (90%), ammonium nitrogen (14.9%) and phosphates (93.8%) with relation to crude sludge liquids. Zetag 8160 alone proved to be the least effective.
PL
akość cieczy osadowych powstających w procesach mechanicznego odwadniania osadów zależy od technologii stabilizacji oraz rodzaju urządzenia, prawidłowej jego pracy oraz właściwego doboru środków chemicznych do kondycjonowania. W artykule przedstawiono wpływ wybranych środków i metod kondycjonowania, takich jak: PIX 113, PIX 123, polielektrolit Zetag 8160, pole ultradźwiękowe oraz łączne ich działanie na właściwości cieczy osadowych. Surowe ciecze osadowe charakteryzowały się wysokimi stężeniami azotu amonowego (931,5–1508,9 mg N-NH4 +/dm3), fosforanów (24,3–89,4 mg PO4 3–/dm3) oraz związków organicznych oznaczonych jako ChZT (784,0–1856 mg O2/dm3). Stwierdzono, że połączone działanie nieorganicznego koagulantu PIX 123 i polielektrolitu pozwoliło na zmniejszenie ilości zawiesin oraz ChZT w cieczach osadowych. W przypadku zawiesiny najlepszy stopień jej zmniejszenia uzyskano przy stosowaniu PIX-u 123. Wynosił on 53,8%. Analizując zmiany ChZT, podobne efekty uzyskano dla PIX-u 123 (43%) oraz metody łączonej (41,6%). Natomiast użycie koagulantu PIX 113 i polielektrolitu Zetag 8160 spowodowało w cieczy osadowej zwiększenie zawiesin ogólnych w odniesieniu do surowych cieczy osadowych. Działanie koagulantu PIX 113 wpłynęło na zmniejszenie wartości ChZT (90%), azotu amonowego (14,9%) i fosforanów (93,8%) w odniesieniu do surowych cieczy osadowych. Najmniej skuteczny okazał się polielektrolit Zetag 8160.
EN
A new idea was investigated in this study wherein the use of coagulants was assessed in the wash-off process to simultaneously remove unfixed reactive dyes from fabrics and wash off liquor. At the end of dark shade dyeing (5% owf) with C.I. Reactive Yellow 145, C.I. Reactive Red 194, and C.I. Reactive Black 5, fabrics were subjected to both conventional and new wash-off methods, and comparisons were made. The effectiveness of coagulant wash-off was evaluated in terms of the change in shade, wash fastness, rubbing properties, and colour difference values (ΔL*,ΔC*, Δh* & ΔE*). The colour removal efficiency (%) of liquor was considered as indicative of the removal of unfixed dyes from the fabric. Overall results have shown that the use of alum and MgCl2 coagulants during the wash-off process can achieve up to an 87% reduction in the colour of wash-off liquor, without compromising the colour properties of the dyed substrate.
PL
W pracy przedyskutowano nową koncepcję polegającą na zastosowaniu koagulantów w procesie prania z jednoczesnym usunięciem niezwiązanych barwników reaktywnych z tkanin tekstylnych i płynów pralniczych. Oceniano zmiany odcieni zabarwienia przy barwieniu barwnikami C.I. Reactive Yellow 145, C.I. Reactive Red 194 i C.I. Reactive Black 5; dla porównania materiały barwione poddano tradycyjnemu praniu i obróbce według opracowanej metody. Wyniki badań wykazały, że stosowanie koagulantów ałunu i MgCl2 podczas procesu pralniczego prowadzi do 87% redukcji koloru płynu pralniczego bez równoczesnego wpływu na kolor barwionych tkanin.
PL
Współczesny rozwój gospodarczy, w szczególności rozwój gałęzi przemysłu wobec wodochłonnego, oraz równoczesna potrzeba sprostania rosnącym wymogom ochrony środowiska w istotny sposób przyczyniają się do konieczności poszukiwania nowych technik i technologii oczyszczania ścieków i uzdatniania wody. Ścieki koksownicze zawierają duże ilości zanieczyszczeń organicznych i nieorganicznych, w tym znaczące ładunki azotu atomowego i inhibitorów przemian biologicznych. Niekorzystny skład oraz częste zmiany dynamiki napływu ścieków sprawiają, że są one bardzo trudne do oczyszczania metodami biologicznymi i wymagają niekonwencjonalnych rozwiązań technologicznych oraz zastosowania chemikaliów o uniwersalnych właściwościach. W publikacji odniesiono się do funkcjonowania instalacji oczyszczania ścieków przemysłowych w JSW KOKS S.A. w oddziale Koksowni Przyjaźń. Przedstawiono uniwersalne zastosowanie koagulant PIX-113 oraz cele jego dozowania każdym z trzech etapów mechanicznego, chemicznego i biologicznego oczyszczania ścieków. Analizie zostały poddane okresy stabilnej pracy procesu oczyszczania ścieków oraz pracy w sytuacjach awaryjnych. Przytoczone w publikacji przykłady potwierdzają, że koagulant PIX-113 jest obecnie jednym z najbardziej uniwersalnych preparatów wykorzystywanych w procesach oczyszczania wód i ścieków.
EN
Modern economic development, especially the progress of high water-absorbing branch of industry together with simultaneous need to fulfill growing environmental standards significantly contribute to the need of searching new techniques and technologies of wastewater treatment and water purification. Cock plant wastewater contain high quantity of organic to its unfavorable composition as well as frequent changes of inflow dynamics the cock plant wastewater is very difficult to treat with biological methods and requires alternative technological solutions and use chemicals with wide range of applications. This paper refers to the performance of industrial wastewater treatment plant system in the Przyjazn Coc Plant unit of JSW KOKS S.A. General-purpose application of PIX-113 coagulant and purposes of its dosage in each of three of mechanic, chemical and biological stages of wastewater treatment process were presented. Periods of stable work of wastewater treatment as well periods of emergency situations were analyzed. Instances described in this paper prove that PIX-113 coagulant is one the most all-purpose preparation used to wastewater and water treatment.
EN
Pre-hydrolysed coagulants are usually more effective in comparison to hydrolysing coagulants e.g. aluminium sulphate. They are particularly well suited at low temperatures and at low alkalinity of raw water. However, despite many advantages resulting from the use of this group of reagents there is a problem of residual alu-minium in the form of fine particles, which have a very negative effect on subsequent unit processes.
EN
The activated sludge method is most frequently used at the stage of biological waste water treatment. The main reason for improper sludge sedimentation is the excessive growth of filamentous bacteria leading to disturbances in technological processes of sewage treatment plants, such as formation of swollen, flowing out sludge, foam transforming in to a thick surface scum, which consequently contributes to a decrease in the effectiveness of removing pollutions from sewage. There is a growing tendency to make attempts aiming at optimizing the chemical methods used to eliminate filamentous bacteria which often constitute a factor limiting proliferation of those bacteria. Accordingly, research was undertaken to estimate the effect of some iron and aluminum coagulants and oxidizing compounds (chlorine dioxide and sodium hypochlorite) on the elimination of filamentous bacteria in the activated sludge in the aspect of sewage treatment effectiveness. Activated sludge was collected from the mechanical and biological sewage treatment plant situated in the Kuyavian-Pomeranian voivodeship. The study was carried out using a laboratory biological reactor graduated to reflect the technological parameters of the sewage treatment plant. Analyses involved determination of physicochemical parameters (total suspensions, sludge volumetric index, sludge density index) and the microscopic evaluation of activated sludge (floc parameters, the composition of microfauna, the Sludge Biotic Index, the quantitative and species composition of filamentous bacteria). At the next stage of the experiment, water solution of iron chloride, water solution of polyaluminum chloride, chlorine dioxide and sodium hypochlorite were proportioned to the activated sludge. At the same time, samples of activated sludge were analyzed without chemical reagents. After a week, the effect of applied reagents on the quantitative and species composition of filamentous bacteria and the other components of activated sludge biocenosis was evaluated. It was proved that activated sludge subjected to analyses was characterized by poor sedimentation properties, resulted from the excessive proliferation of filamentous bacteria of which the most numerous, dominant group was the species Microthrix parvicella. Best effects of filamentous bacteria elimination were recorded after the use of aluminum coagulant, which selectively affected filamentous microorganisms, effectively limiting their excessive proliferation and at the same time not exerting the negative impact on the other organisms of activated sludge. The preparation affected favorable values of the Sludge Biotic Index, which did not substantially differ from that parameter in the control sample. Polyaluminum chlorite caused elimination of the bacteria Sphaerotilus natans and a considerable decrease in the numbers of type 0041micro-organisms. At the same time that preparation contributed to improving sedimentation properties of activated sludge flocs, as a result of which the volumetric index values were decreased in successive research samples, whereas the density index increased. The applied sodium hypochlorite contributed to the elimination of filamentous bacteria, and at the same time it slightly decreased the other parameters of activated sludge. It was indicated that chlorine dioxide contributed to a considerable decrease in diversity of activated sludge microfauna, causing a decrease in the number of crawling ciliates on the flocs and sedentary forms of those macroorganisms. Moreover an increase in the number of bacteriocidal free-floating protozoa and small flagellates resulted in a substantial decrease in the IBO value. The highest doses of reagent caused impoverishment of the biocenosis, which resulted in a decrease in the biotic index values by 7 units in relation to the control sample, activated sludge in those samples was qualified as IV class of sludge quality. The best effects in filamentous bacteria elimination were recorded after the use of aluminum preparation and chlorine compounds (chlorine dioxide, sodium hypochlorite).
PL
Przedstawiono wyniki badań laboratoryjnych mających na celu ocenę możliwości zagospodarowania osadów powstających w zakładach wodociągowych w oczyszczalniach ścieków komunalnych. W tym celu wykonano analizę składu osadów pochodzących z układów oczyszczania wód powierzchniowych w Krakowie, z uwzględnieniem specyfiki osadów pokoagulacyjnych i osadów z wód popłucznych. Próbki tych osadów wykorzystano w testach laboratoryjnych do strącania związków fosforu w ściekach komunalnych i przefermentowanych osadach ściekowych pochodzących z krakowskich oczyszczalni. Wyznaczone dawki badanych osadów wskazują na znacznie większe możliwości praktycznego wykorzystania osadów pokoagulacyjnych niż osadów z wód popłucznych. Uzyskane w tym zakresie rezultaty były korzystne zwłaszcza w przypadku ścieków komunalnych i wskazują na możliwość ograniczenia zużycia klasycznych koagulantów stosowanych do strącania związków fosforu. W badaniach stwierdzono także usuwanie siarczków ze ścieków. Uzyskane wyniki wskazują na celowość rozważenia możliwości wykorzystania osadów z klarowania wody zarówno w samych oczyszczalniach ścieków, jak i przez ich wprowadzenie bezpośrednio do strumienia ścieków w sieci kanalizacyjnej. Dalsze prace w tym zakresie, oprócz pogłębienia wiedzy o mechanizmach badanego procesu, powinny koncentrować się na ocenie ewentualnych negatywnych skutków związanych na przykład ze zwiększeniem masy osadów kierowanych do dalszej przeróbki, a także na ocenie aspektów ekonomicznych i eksploatacyjnych tego procesu.
EN
The results of laboratory studies aimed at an assessment of possibilities for utilization of water treatment sludge produced in municipal plants were presented. For this purpose, content analysis was performed for the sludge coming from surface water treatment systems of Krakow, taking account of post-coagulation sludge and filter backwash sludge specifics. The sludge samples were used in the laboratory tests for phosphorus precipitation in municipal sewage and digested sewage sludge from Krakow treatment plants. The amounts of sludge tested indicated much wider possibilities for management of the post-coagulation compared to the backwash sludge. The results were clearly beneficial especially in case of the municipal sludge and pointed to a possible reduction in the amount of commercial coagulants applied to phosphorus precipitation. Additionally, sulfide removal from the sludge was noted. The study results indicate that it is purposeful to consider the possibility of utilization of sludge from water clarification, both in treatment plants alone and by introducing it directly into the sludge stream in a sewer system. Further studies should, beside extending the knowledge on the mechanisms of studied processes, focus on the evaluation of potential adverse effects related to e.g. increase in the amount of sludge directed for further processing as well as on the assessment of economic and operating aspects of the process.
PL
Przedstawiono wyniki badań dotyczące oczyszczania filtratu z gnojowicy świńskiej przy użyciu dostępnych w handlu koagulantów na bazie chlorku poliglinu, glinianu sodu oraz siarczanu(VI) żelaza(III). Filtrat użyty w eksperymencie otrzymano w wyniku obróbki fizykochemicznej gnojowicy, a następnie jej rozdziału metodą filtracji ciśnieniowej. Stwierdzono, że koagulanty zawierające glin są skuteczniejsze od koagulanta zawierającego żelazo w usuwaniu mętności badanego filtratu, gdyż zastosowane w dawce 0,125% obj. powodowały obniżenie mętności o ok. 97%. Pod względem zmniejszenia parametru ChZT (o ok. 67,5%) oraz barwy (o ok. 89%) najskuteczniejszym spośród testowanych reagentów okazał się koagulant na bazie siarczanu(VI) żelaza(III) odpowiednio w dawce 0,25% obj. i 0,275% obj.
EN
Polyaluminium chloride, Al₂(SO₄)₃ and Fe₂(SO₄)₃ coagulants were added (up to 0.8% by vol.) to pig slurry filtrate to coagulate suspended org. mater, remove turbidity and color as well as decrease the chem. O₂ demand. The Al-contg. coagulants were more efficient than the Fe-contg. one. Use of lowest dose of Al-based coagulants (0.125% by vol.) resulted in a decrease in turbidity by 97%, decrease in chem. O₂ demand by 67.5% and decrease in color intensity by about 89%.
PL
Badania dotyczyły wpływu nieorganicznych koagulantów i polielektrolitów oraz łącznego działania tych dwóch związków na nadźwiękawiane, przefermentowane osady. Do kondycjonowania osadów wykorzystano: koagulant PIX 123 oraz polielektrolit Zetag 8160. Dla niepreparowanych i preparowanych osadów wykonano następujące badania: czas ssania kapilarnego, filtrację próżniową, obserwacje struktury oraz pomiar zawiesiny i ChZT w wodzie nadosadowej. Na podstawie testu CSK dobrano dawki PIX-u 123 oraz dawki polielektrolitu. Badania wykazały, że zastosowanie oddzielne PIX-u 123 i Zetagu 8160 oraz łącznego ich działania powoduje spadek wartości CSK, poprawia parametry opisujące proces filtacji próżniowej oraz wykorzystanie PIX-u 123 łącznie ze stałą dawką Zetagu 8160 zmniejsza zawartość zawiesiny i ChZT w wodach nadosadowych.
EN
The study focused on the effects of inorganic coagulants and polyelectrolytes use and its both impact on sonicated digested sewage sludge. For sludge conditioning coagulant PIX 123 and polyelectrolyte Zetag 8160 were used. For untreated and prepared sludges the following tests were done: capillary suction time, vacuum filtration, structure observation and measurement of the suspension and COD in supernatant sludge. On the basis of the CST tests doses of PIX 123 and a dose of Zetag 8160 were chosen. The results have shown that the use of PIX 123 and Zetag 8160 and their combination causes a decrease in the value of CST, improves parameters of vacuum filtration. The usage of PIX 123 together with a fixed dose of Zetag 8160 reduces suspended solids and COD in the supernatant sludge.
PL
W artykule omówiono metody i środki, które są stosowane do ograniczenia nadmiernego rozwoju mikroorganizmów nitkowatych, i co się z tym wiąże zjawiska puchnięcia występującego przy oczyszczaniu ścieków osadem czynnym.
EN
In this article there are discussed methods and means which are used to limit excessive growth of filamentous microorganisms what entails with phenomenon of bulking occurring in sewage treatment with activated sludge process.
PL
Szereg okresowych aplikacji sekwencji środków kondycjonujących koagulant - polielektrolit przyniósł wyraźne korzyści w redukcji uwodnienia osadów ściekowych. Zastosowanie odpowiednich dawek koagulantu żelazowego przed kondycjonowaniem osadów polimerem okazało się skutecznym rozwiązaniem problemów z zagęszczaniem i odwadnianiem różnego rodzaju osadów ściekowych. Określona wiedza, przede wszystkim o charakterze aplikacyjnym, w zakresie dualnej metody kondycjonowania, pozwala na stwierdzenie, że koagulant mineralny występuje jako początkowy destabilizator powodujący wydajną dehydratację cząstek, natomiast polielektrolit uznano przede wszystkim za środek flokujący i sieciujący. Pełnowartościowa niezawodność i skuteczność proponowanego sposobu kondycjonowania osadów wymaga jednak optymalizacji. Szczególnie na obecnym etapie prób wdrożeniowych brakuje wytycznych uwzględniających wszystkie istotne parametry i zmienne technologiczne. Prowadzone w tym zakresie badania mają na celu rozpoznanie problemów w kondycjonowaniu osadów koagulantem nieorganicznym i polielektrolitem oraz za proponowanie potencjalnych rozwiązań. Finalnie oczekuje się uzyskania modelu mechanizmu działania układu koagulant - polimer, a w dalszej kolejności wydania rekomendacji dla dualnej metody kondycjonowania osadów ściekowych. Można jednak tę metodę zdecydowanie zalecić już teraz, zwłaszcza w sytuacjach problemów eksploatacyjnych w ciągu gospodarki osadowej.
PL
Stacja Uzdatniania Wody "Odra" jest jednym z trzech obiektów uzdatniających wodę na potrzeby miejscowości Świnoujście. Została zlokalizowana w prawobrzeżnej części miasta. Obiekt uzdatnia wodę pochodzącą z ujęć czwartorzędowych, z tym że część to zasoby dobrej jakości - tzw. ujęcie "Wydmy ", druga część to zasoby bardzo złej jakości - ujęcie roboczo nazywane w ten sam sposób jak ZUW, czyli "Odra".
PL
Zasadowość nie może być jednoznacznym kryterium oceny koagulantów wstępnie zhydrolizowanych w aspekcie ich efektywności. Wzrost zasadowości tylko do pewnej wartości powoduje wzrost udziału polimerycznych form glinu. Określenie zależności między zasadowością koagulantów spolimeryzowanych a udziałem tridekamerów Al₁₃ jest możliwe tylko dla grupy koagulantów produkowanych wg jednej ściśle określonej metody, a w przypadku komercyjnych produktów takie informacje są niedostępne.
EN
Six prehydrolyzed com. Al polychlorides of various basicity were analyzed for content of polymeric Al forms by ferronometry to det. the relationship between basicity and content of high polymerized Al forms. The basicity was not found to be unambiguous criterion for assessing pre-hydrolyzed coagulants in terms of their effectiveness.
PL
Oceniono efektywność destabilizacji zużytych emulsyjnych cieczy obróbkowych metodą koagulacji. W procesie wykorzystano sole glinu i żelaza oraz kationowe polielektrolity organiczne. Skuteczność procesu oceniano poprzez badanie zmian chemicznego zapotrzebowania tlenu oraz jakości odzyskanej fazy wodnej. Stwierdzono, że ze względu na różnorodność składu chemicznego cieczy i procesów obróbkowych oraz związane z tym zmiany eksploatacyjne cieczy wybór jednego najefektywniejszego składnika koagulującego jest trudny. Destabilizacja zużytych cieczy obróbkowych metodą koagulacji powinna być poprzedzona przeprowadzeniem wstępnych prób deemulgacji za pomocą kilku wybranych produktów.
EN
The effectiveness of destabilization of used emulsion cutting fluids by means of coagulation method was estimated. In the process aluminium and iron salts as well as organic polyelectrolytes were used. The effectiveness was evaluated by examining the changes in chemical oxygen demand and the quality of the recovered aqueous phase. It was proved that due to diversity of chemical composition of cutting fluids and machining processes and related changes, the choice of the one the most effective coagulant is difficult. Destabilization of used cutting fluids by coagulation should be preceded by conducting preliminary tests with a few selected products.
20
Content available remote Nowe metody rekultywacji wód powierzchniowych na przykładzie jezior w Polsce
PL
Przegląd i analiza najnowszych metod rekultywacji jezior. Zastosowanie koagulantów PAX i PIX oraz Phoslock. Porównanie efektywności działania tych koagulantów.
EN
Review and analysis of newest methods for reclamation of lakes. Application of PAX, PIX and Phoslock coagulants and comparison of its efficiency.