Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  chargeability
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Gradient and Mise-à-la-Masse IP/Resistivity surveys were conducted on a group of 19 boreholes in Eagle’s Nest, Eagle One magmatic sulfide deposit in northern Ontario, Canada. The surveys were conducted as a follow-up to the many drilled boreholes, some of which missed the target. The surveys were intended to map the distribution of the ore mineralization, outline the deposit hosted by mafic and ultramafic rocks and then guide the drilling of new boreholes. Joint Gradient and Mise-à-la-Masse data inversion produced 3D chargeability and conductivity models. The inverted 3D models in turn help delineate the outline of the mineralized zone, and determine the shape, size, strength and economic viability of the deposit. The Gradient array determined the direction of the mineralization with respect to the boreholes, and the Mise-à-la-Masse array examined the highly conductive subsurface bodies and their surroundings. The mapped ore zone shows close similarity to the 0.5 Cu% and 1.05 Ni% iso-surfaces that are produced from core assay result confirming the reliability of the results obtained in this study.
PL
Celem niniejszego artykułu jest zapoznanie środowisk inżynierskich z mechanizmami zagrożeń wybuchowych od elektryczności statycznej w atmosferach potencjalnie wybuchowych. Dla podbudowania postawionych tez i opisów literaturowych tych zjawisk, przeprowadzono serię przykładowych prób i obserwacji z inicjacji wybuchów w komorze wybuchowej, szczególnie przy wygenerowaniu wyładowań elektrostatycznych (ESD). Opisano też jedną z technik zbierania ładunku elektrycznego Q oraz fazy rozwoju wybuchu.
EN
The purpose of this article is to better understand the risks posed by static electricity in potentially explosive atmospheres. Incendivity ability tests were conducted inside a stationary explosive chamber filled with a homogeneous flammable gas mixture with air. An exemplary study of incendivity ability triggered indirectly by not intrinsically propagating brush discharging have been presented. The study was conducted in an area where intrinsic ESD caused the inflammation of the explosive atmosphere.
PL
Niekontrolowana elektryczność statyczna jest poważnym problemem, który od dawna jest postrzegany w wielu gałęziach przemysłu. Ciało człowieka jest podatne na naelektryzowanie. Rozładowanie naelektryzowanego ciała człowieka może wystąpić w trakcie przypadkowego dotknięcia uziemionego elementu przewodzącego. Rozładowaniu naelektryzowanego ciała człowieka do ziemi towarzyszy wytwarzanie bardzo dużej energii [5].
EN
Uncontrolled static electricity is a serious problem, which has long been recognised in many branches of industries. The human body is prone to chargeability. Discharge from the charged human body may occur during accidental touching of a grounded conductive element. Such a discharge is accompanied by the generation of extremely high energy [5].
EN
Most primary explosives are non-conductors, easily accumulate charge when contacting with and separating from other materials, and are sensitive to electrostatic discharge (ESD). In order to reduce the number of accidents caused by ESD initiation of primary explosives, studies on their electrostatic hazards are necessary. This work presents comprehensive experimental results of electrostatic discharge sensitivity and chargeability of tris(carbohydrazide)zinc perchlorate (ZnCP) under different conditions. The influences of the testing conditions, of devices, particle size, ambient temperature and relative humidity on the electrostatic discharge sensitivity and chargeability have been investigated in detail, and the quantitative regression equations obtained.
EN
The purpose of this work was to detect groundwater pollution and to identify the conditions of soil and groundwater near the Urbanowice landfill site using geoelectrical measurements. Presented measurements are preliminary results from tested site and are beginning of continuous monitoring. Contamination outflows detected by resistivity and IP technique show a good correlation with available hydrological data. Contamination plume were found in Eastern part of survey profil.
PL
W artykule przedstawiono metodę polaryzacji wzbudzonej, a w szczególności jej zastosowanie do bezpośredniego wykrywania złóż węglowodorów. Zaprezentowane zostały parametry polaryzacji wzbudzonej, jakie uzyskuje się w pomiarach w domenie czasu i częstotliwości. Przeanalizowana została klasyfikacja skał i minerałów ze względu na parametr polaryzowalności. Przedstawiono pięć przykładów wykorzystania metody polaryzacji wzbudzonej do wykrywania i rozpoznawania złóż węglowodorów przez zagraniczne firmy poszukiwawcze. Omówiona została metodyka prac polowych na obszarze polskich Karpat i zapadliska przedkarpackiego w przypadku zastosowania układu ekwatorialnego i dipolowego układu osiowego. Przeanalizowano mapy rozkładów parametru fazowego uzyskane z pomiarów układem ekwatorialnym w złożach Rudka i Grabownica oraz wykres parametru fazowego wzdłuż profilu przecinającego złoże Rylowa. Sporządzono przekroje trzech parametrów polaryzacji wzbudzonej uzyskane z pomiarów dipolowym układem osiowym, a następnie przeanalizowano je w kompleksie z przekrojami oporności wyinterpretowanymi na podstawie danych CSAMT.
EN
The paper presents the method of induced polarization (IP) and focuses on its application to direct prospecting for hydrocarbon deposits. Induced polarization parameters that are obtained from measurements in time domain and frequency domain are presented. Classification of minerals and rocks based on induced polarization parameter was analyzed. Five examples of application of induced polarization method to discovering and recognizing hydrocarbon deposits by foreign companies were given. Methodology of field works made in Carpathians and Carpathian Foredeep with the use of equatorial and dipole-dipole arrays was described. Maps of phase parameter evaluated from results of equatorial array measurements for Grabownica and Rudka deposits as well as the plot of phase parameter along profile cutting the area of Rylowa deposit were analyzed. Cross-sections of three induced polarization parameters were made and analyzed with CSAMT resistivity sections in the area of Rudka deposit.
EN
Oil contaminations of soils are connected with human activity, for instance military activity. Organic pollution finding is one of environmental protection problems. Our field investigation was carried out to localize oil contaminations with induced polarization method (IP). The studied area is situated in post-Soviet military fuel base. The area is covered by postglacial sediments. Part of selected experimental area was submitted to bioremediation process. IP measurements indicated the relationship between bioremediation area and increase of chargeability effect. Two types of electrodes were used for measurements: stainless steel and non-polarizable ones. The survey results confirmed more accuracy of non-polarizable electrodes for postglacial area conditions. This method could be used to monitor efficacy of bioremediation process of hydrocarbons contaminated soils as well.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.