EN
The use of waste heat in many branches of industry is limited due to temperature in the range of 30 to 100°C. One of the methods of using waste heat are devices that implement the Organic Rankine Cycle (ORC). In currently used ORC systems, the heat source temperature is at least 80oC, while the low temperature heat source (usually atmospheric air) has a temperature of 30oC. The work analyzes the influence of the organic fluids properties on the performance of the proposed installation driven by the waste heat and working based on the ORC. The basic operation parameters in nominal conditions were determined for three selected natural refrigerants R290, R600a, R717 and one synthetic R245fa. The condensing temperature 30oC were defined as a nominal value. The research results compare how the generated electric power will change depending on the temperature difference between the temperature of the heat source and the temperature of evaporation. It turns out that for a device with finite dimensions, the maximum power is obtained for a specific evaporation temperature. And this is not the highest temperature that can be achieved. The highest evaporation temperature allows for the highest efficiency of the system, but not the maximum of capacity.
PL
Ekonomiczny konflikt wartości powstaje, gdy celem obniżenia zużycia energii, jako chłodziwo wykorzystujemy wodę. Podłożem tego konfliktu będzie każdorazowo zależność: mniejsze zużycie energii versus zaburzenie naturalnego obiegu wody w przyrodzie.
EN
Following the entry into force of the Regulation (EU) No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing Regulation (EC) No 842/2006, the scope of refrigerants, which have so far been commonly used is very limited. All preferred refrigerants are mostly flammable and explosive, and they include R32, R1234yf, R1234ze, R290 (propane), R600a (isobutane), R717 (ammonia). However, it should be noted that refrigerants such as R32, R1234yf, R1234ze are classified as mildly flammable and has been created for them, in accordance with ISO 817 standard, special group called A2L. It is also worth noting that the new classification moved ammonia to the group B2L - that means is toxic and mildly flammable. The article focuses on defining the conditions in which there is possible to build safely split installation in which the propane is a refrigerant. It turns out that small splits are devices which can be used safely with R290 in most cases.
EN
The paper presents the methodology of the analysis of the cooling system reconstruction in a food cold store under the regulations applicable from the beginning of 2020. They result from the so-called the F-Gas Act concerns the use of refrigerants with a low environmental impact. First, the elements of the existing regulations on the use of refrigerants were discussed. This part of article focus mainly on the F-Gas Act and the regulations it entails. Then, the refrigerants used so far in refrigeration systems were compared with substitutes, which were the only ones that have been approved for use since 2020, thanks to the low GWP index. Their properties are briefly described, along with the benefits (primarily for the environment) of their use. The main part of the work is the analysis of the reconstruction of the cooling system to use an alternative refrigerant. During the work, the construction of the cold storage was analyzed together with the system currently working in analysed location. Then, the heat balance was calculated, thanks to which it was possible to determine the demand for cold. Than, several refrigerants that meet the latest standards and application regulations were selected. Their operating parameters were examined, the possible variants of use were compared in relation to the determined demand for cooling and the most important operational features were summarized.
EN
Corrosion inhibitors in the antifreeze include both inorganic and organic compounds. Organic additives applied in the antifreeze usually form thinner protective coatings. In spite of this fact, it is believed that they protect the exposed surfaces against corrosion more efficiently than fluids with inorganic additives. This work investigates whether the effects on the steel surface occurring due to the antifreeze meet key normative requirements. Microscopic imaging was used to identify the alterations in the surface invisible in the macro scale. The tests aimed to evaluate the potential of the antifreeze intended for combustion engines in the perspective of applying them in HVAC systems.
PL
Inhibitorami korozji w płynach niskokrzepnących mogą być związki nieorganiczne lub organiczne. Dodatki organiczne w płynach niskokrzepnących przeważnie tworzą cieńsze powłoki ochronne, mimo to uznaje się, że skuteczniej zabezpieczają narażone powierzchnie niż płyny z dodatkami nieorganicznymi. W niniejszej pracy zbadano efekty na powierzchni stali pojawiające się pod wpływem płynów niskokrzepnących spełniających kluczowe wymagania normatywne. Zastosowano mikroskopowe obrazowanie, które pozwoliło zidentyfikować zmiany powierzchni niewidoczne w skali makro. Badania miały na celu ocenę potencjału płynów niskokrzepnących do silników spalinowych w perspektywie ich wykorzystania w instalacjach grzewczo-chłodząco-wentylacyjnych.
6
Content available remote The impact of environmentally friendly refrigerants on heat pump efficiency
EN
This paper discusses the issue of heat pump simulation. Lower operating costs can be achieved through good equipment design and appropriate operation. Detailed technical and economic analysis inform the selection of system components with the highest possible efficiency and lower energy demand. The use of systems based on environmentally friendly refrigerants can deliver long product life, which is associated with a shorter payback period for the investment. In addition, smart design processes optimize the performance of equipment. The rapidly increasing share of energy costs in terms of total investment cost is driving innovative solutions and tailor-made solutions to specific operating conditions.
EN
Investigations of refrigerant condensation in pipe minichannels are very challenging and complicated issue. Due to the multitude of influences very important is mathematical and computer modeling. Its allows for performing calculations for many different refrigerants under different flow conditions. A large number of experimental results published in the literature allows for experimental verification of correctness of the models. In this work is presented a mathematical model for calculation of flow resistance during condensation of refrigerants in the pipe minichannel. The model was developed in environment based on conservation equations. The results of calculations were verified by authors own experimental investigations results.
PL
Oleje emulgujące są szeroko stosowane w ubytkowej obróbce metali. Stosuje się je najczęściej w stężeniu 5% v/v. Zawierają olej mineralny lub syntetyczny w ilości 40 - 83%, emulgatory najczęściej wielofunkcyjne w ilości 15 - 60% v/v oraz biocydy i fungicydy w ilości ok. 2% v/v oraz środki antypienne. Na etapie komponowania i oceny technologicznej stosuje się wiele badań, takich jak np. badania fizykochemiczne, technologiczne i trwałościowe. Przedstawiono metody badań chłodziw na etapie komponowania oraz wybrane wskaźniki oceny komponowanego w ITeE koncentratu chłodziwa na bazie oksyetylatów cardanolu. Przedstawiono także kilka metod oceny właściwości smarnych cieczy obróbkowych.
EN
Emulsifying oils are commonly used in the metal-removing machining. They are most often used in the concentration of 5% v/v. Emulsifying oils contains: mineral or synthetic oil in quantity of 40 to 83%, multifunctional emulsifiers in quantity of 15 to 60% v/v, biocides and fungicides in the concentration of approx. 2% v/v and antifoaming agents. At the stage of composing and technological assessment a number of studies are used such as physicochemical, technological and durability The authors present the test methods of coolants at the stage of composing as well as selected evaluation indicators of coolant concentrate composed in ITEe on a basis of cardanol ethoxylates. The paper presents also several methods for assessing of lubricating action of cutting fluids.
9
PL
W artykule opisano ocenę dokładności wymiarowo-kształtowej otworów wierconych wiertłami składanymi z zastosowaniem różnych sposobów doprowadzenia cieczy chłodząco-smarującej.
EN
The article describes evaluation of accuracy dimensionally shaped holes drilled by indexable insert drill using different modes of administration of cutting fluid.
PL
W artykule zostaną omówione warunki i czynniki, które sprzyjają biologicznemu skażeniu chłodziw. Wzrost drobnoustrojów w chłodziwach istotnie obniża ich jakość i może wpływać na parametry wytwarzanych produktów w zakładach przemysłu metalowego. Drobnoustroje i produkty ich rozpadu mogą stanowić zagrożenie dla zdrowia pracowników. W artykule zostaną przedstawione także sposoby zapobiegania skażeniu chłodziw.
EN
The publication will discuss the conditions that are favorable to biological contamination of metalworking fluids. Microbial growth in the coolant significantly lowers their quality and can affect the performance of manufactured products in metal industry plants. Micr oorganisms and their disintegration products may pose a risk to workers’ health. The means how to prevent contamination of metalworking fluids will also be discussed.
11
Content available remote Metodyka projektowania wysokociśnieniowych dysz chłodziwa
PL
W artykule przedstawiono proces projektowania wysokociśnieniowych dysz chłodziwa. Wyszczególniono poszczególne etapy, które należy rozważyć podczas projektowania. Przedstawiono wybrane wyniki symulacji MES przepływu chłodziwa oraz sformułowano na bazie wyników wytyczne pomocne podczas konstrukcji dyszy.
EN
The article presents the design process of high-pressure coolant nozzles. Specified steps that should be considered when designing. Selected results FEM simulation of coolant flow and formulated based on the results helpful guidelines for nozzle design.
12
Content available remote Zastosowanie zawiesiny lodowej w klimatyzacji
PL
W pracy przedstawiono możliwości zastosowania zawiesiny lodowej w technice klimatyzacyjnej. Zawiesina lodowa jest mieszaniną kryształków lodu i cieczy, którą jest najczęściej woda, lub woda z dodatkiem środka obniżającego jej temperaturę zamarzania. Wytwarzana jest w różnego typu generatorach, z których do najczęściej stosowanych należą mechaniczne generatory skrobakowe. Wykorzystanie zawiesiny lodowej jako nośnika ciepła w systemach klimatyzacyjnych, w stosunku do systemów z wodą lodową wiąże się z wieloma korzyściami, takimi jak: zmniejszenie ilości chłodziwa w układzie, zmniejszenie średnicy rurociągów, zmniejszenie wielkości wymienników ciepła (nawet o 50%), przy zachowaniu takich samych wydajności. Zastosowanie zawiesiny lodowej w klimatyzacji pozwala na obniżenie temperatury powietrza pierwotnego o 5,5 K, co umożliwia redukcję jego strumienia o ponad 40%. Dodatkowym efektem związanym z niższą temperaturą powietrza pierwotnego są lepsze warunki komfortu, dzięki obniżeniu wilgotności względnej powietrza z 60 do 35%. Te efekty mają wpływ na działanie układu regulacji, gdyż przy takim samym obciążeniu cieplnym obiektu możliwe są wyższe nastawy temperatury o około 1,5 K. Podstawową zaletą instalacji z zawiesiną lodową jest możliwość skojarzenia jej z systemem akumulacji ciepła. Pozwala to na ograniczenie szczytowej mocy urządzenia ziębniczego o 50-80%, redukcję o 80% napełnienia instalacji czynnikiem ziębniczym oraz wykorzystanie nocnych taryf energii elektrycznej i zmniejszenie kosztów eksploatacyjnych o 25-50%. Stosując zawiesinę lodową można kilkakrotnie zmniejszyć pojemność zbiornika akumulacyjnego. W pracy omówiono również przykładowe instalacje klimatyzacyjne z zawiesiną lodową kompleksu budynków i kopalni złota.
EN
The paper presents the possibility of using ice slurry in air conditioning. Ice slurry is a mixture of ice crystals and liquid, which is mostly water, or water with the addition of a freezing point lowering agent. It is produced in different types of generators, mostly in mechanical scraped generators. The benefits of using ice slurry as a coolant in air conditioning systems, when compared to systems fed witch ice-cold water, include reducing the amount of coolant in the system, reducing the diameter of the piping, reducing the size of the heat exchangers by up to 50%, while maintaining the same cooling capacity. The use of ice slurry in air conditioning makes it possible to lower primary air temperature by 5,5 K, which enables a reduction of its flux by more than 40%. An additional effect connected with the lower temperature of primary air is the improvement of comfort conditions, which results from reducing the relative humidity of air from 60 to 35%. These effects have an influence on the operation of the regulation system, since, with the same thermal load of a building, it is possible to set higher temperature by circa 1,5 K. The main advantage of ice slurry based installations is the ability to combine them with a thermal storage system. This makes it possible to reduce the peak power of the refrigeration appliance by 50-80%, as well as to reduce the refrigerant level in the installation by 80%, use night electricity tariffs and reduce operating costs by 25 - 50%. Using ice slurry also makes it possible to reduce storage tank capacity several times. The paper also looks at air conditioning systems with ice slurry in a building complex and a gold mine.
EN
The article presents the results of experimental studies of the turning process of the alloy Ti-6Al-4V with high pressure coolant. Microstructures of cutting material for various of tool wear were evaluated. Also used the FEM numerical methods to simulate the process.
PL
W artykule przedstawiono wyniki badań doświadczalnych procesu toczenia stopu Ti-6Al-4V z chłodziwa pod wysokim ciśnieniem. Oceniano mikrostruktury materiału tnącego dla różnych użytych narzędzi. Do symulacji procesu stosowano metody numeryczne MES.
PL
Doświadczenia z wieloletnich okresów eksploatacji instalacji chłodniczych w obiektach użyteczności publicznej w tym instalacji sztucznych lodowisk spowodowały, że w Polsce stosowane są przeważnie chłodziwa, jakimi są wodne roztwory glikoli mono-etylenowego i mono-propylenowego. Popularne przed laty wodne roztwory soli chlorku sodu (NaCl) lub chlorku wapnia (CaCl2), zwane solankami, zostały obecnie praktycznie wyeliminowane ze stosowania w instalacjach chłodniczych w obiektach użyteczności publicznej, ze względu m.in. na swoje silnie korozyjne właściwości. Bazując na doświadczeniach wynikających z projektowania takich instalacji można zauważyć, że w niektórych krajach Europy Zachodniej obecnie staje się coraz bardziej popularny w stosowaniu, znany od dawna jako chłodziwo, wodny roztwór amoniaku. Ocenia się, że w ciągu ostatnich 5 lat zrealizowano w Europie około 50 instalacji mrożeniowych lodowisk, w których zastosowano to chłodziwo. Realizacje te miały miejsce zwłaszcza we Francji, Szwecji i Finlandii. Innym chłodziwem, coraz bardziej popularnym w stosowaniu w niskotemperaturowych instalacjach chłodniczych, staje się solanka: wodny roztwór organicznej soli potasowej (mrówczanu potasu z dodatkiem inhibitorów korozji), stosowany głównie w Finlandii, Szwecji, Danii, Czechach. W Polsce także pojawiają się propozycje wykorzystywania tych chłodziw w instalacjach mrożeniowych lodowisk. W niniejszym artykule dokonano analizy porównawczej dotyczącej właściwości wody amoniakalnej i mrówczanu potasu, jako chłodziw, w celu oszacowania ewentualnych korzyści z ich zastosowania.
EN
In result of the experience from long-term periods of refrigeration systems operation in public buildings, including ice rinks, mono-ethylene and mono-propylene glycol dilutions are nowadays commonly used as coolants for freezing ice rink installations in Poland. Aqueous sodium chloride (NaCl) and calcium chloride dilutions (CaCl2), called brines, popular years ago, have gone out of use in cooling systems in public buildings, owing to – among others – their strong corrosive properties. Basing on the experience in such systems designing, it can be seen that in some Western European countries aqueous ammonia dilution, long known as a coolant, is becoming more and more popular. It is estimated that aqueous ammonia dilution has been used in about fifty ice rink freezing installations constructed in Europe within the last five years, especially in France, Sweden and Finland. Another coolant, which is becoming more and more popular for low temperature refrigeration systems, is brine: aqueous solution of organic potassium salt (potassium formate with addition of corrosion inhibitors) used mainly in Finland, Sweden, Denmark and in the Czech Republic. In Poland there are also suggestions to use these refrigerants in ice rinks refrigeration systems. The paper presents a comparative analysis of the properties of aqueous ammonia dilution and potassium formate, to estimate the potential benefits of their use as a coolant.
15
PL
Stosowanie cieczy chłodząco-smarujących (chłodziw) podczas obróbki skrawaniem stanowi element procesu wytwarzania części metalowych. Zastosowanie chłodziw pozwala na zmniejszenie tarcia pomiędzy narzędziem skrawającym a elementem obrabianym i na wydajne obniżenie temperatury procesu, a dzięki temu na precyzyjną obróbkę spełniającą wysokie wymagania. Wysoka biostabilność używanego chłodziwa jest bardzo istotna i wpływa na jakość wytwarzanego wyrobu. Producenci unowocześniają stale skład cieczy chłodząco-smarujących, tak aby zapewnić zachowanie ich optymalnych parametrów przez długi okres użytkowania.
PL
W pracy przedstawiono modele numeryczne zjawisk cieplnych, przemian fazowych i zjawisk mechanicznych zbudowane na bazie metody elementów skończonych (zadanie 2D). Opracowany model zjawisk mechanicznych daje możliwość symulacji stanu naprężenia w zakresie sprężysto-plastycznym ze wzmocnieniem izotropowym. Makroskopowy model przemian fazowych zbudowano z wykorzystaniem wykresów CTPc dla stali C45. Uwzględniono wpływ prędkości zanurzania do chłodziwa na skład fazowy i naprężenia w hartowanych elementach stalowych.
EN
In the paper numerical models of thermal phenomena, phase transformations and mechanical phenomena built on the basis of the finite element method (two-dimensional tasks) are presented. The model of mechanical phenomena gives the possibility to the simulate the stress in the elastic-plastic range with isotropic hardening. The macroscopic model of the phase transformations was built using the CCT diagrams for the C45 steel. In the paper influence of the rate of immersion on the phase composition and stress state during hardening of steel element have been taken into account.
17
Content available remote Application of Minimal Quantity Lubrication in Gear Hobbing
EN
The results of investigations on application of Minimal Quantity Lubrication (MQL) in gear hobbing are presented in the paper. The experimental stand which allows measurements of cutting forces, Fc, is described. Experiments were carried out for MQL and flood cooling. The influence of the fluid supply methods on tool wear and cutting forces is presented in the paper. The influence of the different workpiece materials is presented, too. The investigations have proved that the using of the MQL method is by all means justified. The results indicate that the hob wear rate is similar for the MQL and for conventional flood cooling. This is also confirmed by the measurements of cutting forces, which values are comparable for both methods.
18
Content available Flow modeling in an intercooler
EN
The paper deals with the numerical modeling of charging air flow and cooling air flow in a charge air intercooler. The intercooler is air/air type and is used for the four stroke compression ignition engine with the total displacement of 7,6 l. The CATIA - CAD (Computer Aided Design) software is used for modeling of the 3D space geometrical model of the intercooler. The preprocessor Gambit is used for the creating of the needed computational mesh and the Fluent - CFD (Computational Fluid Dynamics) software is then used for the simulation itself and the postprocessing. The charge air flow in the intercooler is evaluated through the simulation results. Consequently the places with the maximum values of the velocity magnitudes for the charging air flow and the cooling air flow can be found. The simulation shows that the maximum value of velocity magnitude for the charging air flow is in the area of the intercooler inlet. The maximum value of velocity between the cooling fins is found through the simulation. Through this the information for the optimization of the intercooler can be gained. The purpose of the simulation is to use the low temperatures of charging to obtain more effective energy utilization, the decrease of the environment ecological load compared with the standard solution.
19
Content available remote Powyłączeniowe prądy konwekcyjne w prętach paliwowych reaktora MARIA
PL
W pracy przedstawiono wyniki symulacji obliczeniowych pola temperatury i prędkości chłodziwa wewnątrz prętów paliwowych rektora MARIA po wyłączeniu reaktora. W wyniku istnienia mocy powyłączeniowej w reaktorze jądrowym wydziela się ciepła w ilości wymagającej początkowo pracy pomp chłodziwa, po pewnym czasie natomiast bezpieczne odprowadzanie ciepła powyłączeniowego zapewnia już konwekcja naturalna. Dla tego przypadku, za pomocą kodu FLUENT, wyznaczono rozkłady prędkości i temperatury wody chłodzącej wewnątrz pręta paliwowego o złożonej postaci, a następnie określono maksymalne temperatury wody i paliwa jądrowego, w zależności od aktualnej mocy cieplnej pręta.
EN
Results of numerical calculations of the reactor coolant temperature and velocity field inside MARIA reactor fuel rods after switching off the reactor are presented in the paper. After nuclear reactor shut-down, fission products decay and generate such amount of heat that for some period of time there is necessary to use coolant pumps. Next, after about half an hour, it is possible to use coolant natural convection for safe carrying away after shut-down heat. For this case, coolant velocity and temperature distributions inside the fuel rod of complex form are determined and analyzed as well as the maximal values of water and nuclear fuel temperatures for various values of actual fuel rod heat power. FLUENT computer code is used for this purpose.
20
Content available remote Heat teransfer coefficient for F.E. analysis in the warm forging process
EN
Purpose: The purpose of this paper is to obtain suitable convection and contact heat transfer coefficient for one-time finite element analysis in the warm forging process. Design/methodology/approach: To do this, the temperature of the tool used in the operation was measured with a thermocouple and repeated finite element analysis (FEA) was performed using the experimentally calculated contact at cooling heat transfer coefficient. Also the surface temperature of the active tool was obtained by comparing the measurement and analysis results and finally the contact heat transfer coefficient for one-time FEA was completed by comparing the surface temperature between the repeated FEA and one-time FEA results. Findings: The acceptable convection heat transfer coefficients are from 0.3 to 0.8 N/mm/s/K and the contact heat transfer coefficient of 6-9 N/mm/s/K is appropriate for the warm forging process with flow-type lubrication conditions. Practical implications: A comparison of the temperatures from the repeated and one-time analysis allows an optimum contact heat transfer coefficient for the one time finite element analysis to be determined. Originality/value: several studies have been conducted with diferent conditions such as applied pressure and kind of lubricant, but no research has been conducted concerning the convection heat transfer coefficient in the warm forging process. Also, comparative analysis concerning the reason for difference between experimentally determined contact heat transfer coefficient and practically adapted one has been conducted, yet.