Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 18

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  chłodziarka absorpcyjna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Wybrane zagadnienia eksploatacyjne agregatów absorpcyjnych
PL
Opisano zagadnienia eksploatacyjne agregatów absorpcyjnych, przedstawiono chłodziarki absorpcyjne oraz procesy zachodzące w absorberze, zmiany fizykochemiczne zachodzące w układzie oraz sposób wytwarzania wody lodowej. Zaprezentowano zastosowanie urządzeń chłodniczych połączonych kaskadowo w celu osiągnięcia końcowego produktu o określonych parametrach.
EN
Operational problems of absorption chillers in a combined energy and cooling system were reviewed. Absorption chillers and the processes taking place in the absorber, physicochemical changes in the system and the method of producing chilled water were presented. The application of cooling devices connected in a cascade in order to obtain a product with specific parameters was presented.
PL
W artykule opisano różne metody wytwarzania nośników energii na potrzeby obiektów budowlanych. Omówiono źródła zdecentralizowane (rozproszone) oraz układy scentralizowane, w których do produkcji wody lodowej na potrzeby klimatyzacji obiektów wykorzystano, niedociążone w lecie, miejskie systemy ciepłownicze. Opisano konieczne modyfikacje warunków eksploatacji systemów ciepłowniczych oraz graniczną, minimalną wartość zapotrzebowania na moc chłodniczą zapewniające energetyczną i ekologiczną efektywność eksploatacji systemu. Przedstawiono również zarys prac teoretycznych i wdrożeniowych prac wykonanych w tym zakresie w kraju oraz opisano kilka przykładów rozwiązań systemów trójgeneracyjnych.
EN
The article describes different methods of producing energy carriers for building objects. Decentralized (dispersed) sources and centralized systems, in which the city’s district heating systems have been used to produce chilled water for the air conditioning of facilities that are underloaded in summer, are discussed. Necessary modifications to the operating conditions of district heating systems are described, as well as the limit, minimum cooling capacity requirements to ensure energy and environmental efficiency of system operation. An outline of the theoretical and implementation work carried out in this respect in the country has been also presented, and several examples of solutions for tri-generation systems described.
PL
W artykule opisano różne metody wytwarzania nośników energii na potrzeby obiektów budowlanych. Omówiono źródła zdecentralizowane (rozproszone) oraz układy scentralizowane, w których do produkcji wody lodowej na potrzeby klimatyzacji obiektów wykorzystano, niedociążone w lecie, miejskie systemy ciepłownicze. Opisano konieczne modyfikacje warunków eksploatacji systemów ciepłowniczych oraz graniczną, minimalną wartość zapotrzebowania na moc chłodniczą zapewniające energetyczną i ekologiczną efektywność eksploatacji systemu. Przedstawiono również zarys prac teoretycznych i wdrożeniowych prac wykonanych w tym zakresie w kraju oraz opisano kilka przykładów rozwiązań systemów trójgeneracyjnych.
EN
The article describes different methods of producing energy carriers for building objects. Decentralized (dispersed) sources and centralized systems, in which the city’s district heating systems have been used to produce chilled water for the air conditioning of facilities that are underloaded in summer, are discussed. Necessary modifications to the operating conditions of district heating systems are described, as well as the limit, minimum cooling capacity requirements to ensure energy and environmental efficiency of system operation. An outline of the theoretical and implementation work carried out in this respect in the country has been also presented, and several examples of solutions for tri-generation systems described.
PL
W artykule opisano różne metody wytwarzania nośników energii na potrzeby obiektów budowlanych. Omówiono źródła zdecentralizowane (rozproszone) oraz układy scentralizowane, w których do produkcji wody lodowej na potrzeby klimatyzacji obiektów wykorzystano, niedociążone w lecie, miejskie systemy ciepłownicze. Opisano konieczne modyfikacje warunków eksploatacji systemów ciepłowniczych oraz graniczną, minimalną wartość zapotrzebowania na moc chłodniczą zapewniające energetyczną i ekologiczną efektywność eksploatacji systemu. Przedstawiono również zarys prac teoretycznych i wdrożeniowych prac wykonanych w tym zakresie w kraju oraz opisano kilka przykładów rozwiązań systemów trójgeneracyjnych.
EN
The article describes different methods of producing energy carriers for building objects. Decentralized (dispersed) sources and centralized systems, in which the city’s district heating systems have been used to produce chilled water for the air conditioning of facilities that are underloaded in summer, are discussed. Necessary modifications to the operating conditions of district heating systems are described, as well as the limit, minimum cooling capacity requirements to ensure energy and environmental efficiency of system operation. An outline of the theoretical and implementation work carried out in this respect in the country has been also presented, and several examples of solutions for tri-generation systems described.
PL
W artykule zaprezentowano propozycję modernizacji standardowego układu chłodniczego stosowanego powszechnie w krajowym przemyśle mleczarskim za pomocą instalacji bromolitowego agregatu absorpcyjnego. Miejsce instalacji agregatu zostało dobrane w sposób umożliwiający maksymalizację czasu jego pracy, a co za tym idzie efektu ekonomicznego. Rozszerzenie wykorzystywanych źródeł zasilania układu chłodniczego o ciepło pochodzące z lokalnej kotłowni umożliwiło zarówno zwiększenie poziomu bezpieczeństwa całej instalacji, jak i poprawę wskaźników środowiskowych dzięki wykorzystaniu ciepła odpadowego do zasilania agregatu produkującego chłód. Wykorzystanie ciepła odpadowego umożliwiło także osiągnięcie wzorowych wręcz wskaźników ekonomicznej opłacalności inwestycji.
EN
Publication presents proposition of modernization of chilled water production installation working for the purposes of cheese production facility located in Poland with lithium bromite absorption chiller. Absorption chiller connection with existing installation has been selected basing on maximiscition of economic and energetic effect. Cooling source extension by chiller supplied with different energy source allowed irnprovement of safety and reliability of the installation as well as enviromnental impact decrease by avoiding atmospheric emissions. Waste heat utilization led to exemplary economic efficiency of installation.
PL
W pracy przedstawiono problematykę przygotowania ditlenku węgla do transportu i składowania. Wykazano, że najodpowiedniejszą formą transportu ditlenku węgla jest faza ciekła. Przedstawiono podstawy procesu wielostopniowego sprężania z chłodzeniem międzystopniowym. Dokonano analizy wyboru czynnika chłodzącego CO2 , wykazano, że ochłodzenie go do założonego poziomu 20° C wymaga zastosowania urządzenia chłodniczego w postaci chłodziarki absorpcyjnej. Przeprowadzono wielowymiarową optymalizację układów wielostopniowego sprężania z chłodzeniem międzystopniowym, której kryterium była minimalizacja mocy niezbędnej do sprężania, ustalono optymalne parametry ditlenku węgla za każdym stopniem sprężania. Dokonano analizy możliwości wykorzystania ciepła odpadowego z układu międzystopniowego chłodzenia na potrzeby zasilania chłodziarki absorpcyjnej i chłodzenia CO2 na potrzeby transportu. Ustalono, że w każdym z 4 analizowanych układów istnieje możliwość wykorzystania ciepła odpadowego do tego celu. W dwóch przypadkach istnieje możliwość produkcji chłodu na cele przemysłowe lub komercyjne. Rozważono także możliwość wykorzystania ciepła odpadowego dodatkowo w układzie regeneracji wody zasilającej kocioł parowy.
EN
The paper presents the problem of the preparation of carbon dioxide for transport and storage. It has been shown that the most suitable form of carbon dioxide transport is the liquid phase. It shows the base of the process of multi-stage compression with intercooling. An analysis of the choice of refrigerant CO2 , demonstrated that cooling it to a predetermined level of 20° C requires a refrigeration unit in the form of an absorption chiller. Multidimensional optimization systems multistage compression with intercooling was conducted, the criterion of which was to minimize the power required for compression and set optimal parameters of carbon dioxide for each compression ratio. An analysis of the possibilities of using waste heat from the inter-stage cooling needs of the power absorption chiller and cooling CO2 for transport was carried out. It was found that each of the 4 analyzed systems can utilize waste heat for this purpose. In two cases, producing cold for industrial or commercial purposes was also possible. The possibility of using waste heat in a recovery boiler feedwater steam was also considered.
7
PL
Przedstawiono znaczenie rozwoju technologii chłodzenia z wykorzystaniem energii promieniowania słonecznego. Systemy takie z reguły używają dodatkowego źródła ciepła pozwalającego osiągnąć temperaturę efektywnej pracy chłodziarki absorpcyjnej. W tym celu w wielu rozwiązaniach stosowane są dodatkowe źródła ciepła w postaci podgrzewaczy elektrycznych, gazowych i innych czyli używających energię nieodnawialną. W krajach południowych możliwa jest praca systemu chłodniczego wyłącznie w oparciu o energię odnawialną przy wykorzystaniu odpowiednio dużych zestawów kolektorów próżniowych. Jednakże w Polsce instalacje kolektorów słonecznych bazują najczęściej na kolektorach płaskich i nie posiadają tak dużej powierzchni. Dlatego przewidziano układ bazujący na kolektorach płaskich z dogrzewaniem czynnika roboczego w postaci koncentratora promieniowania słonecznego. W pracy przedstawiono opis stanowiska badawczego oraz wybrane wyniki badań pracy takiego hybrydowego układu. Wykonano modelowanie pracy układu hybrydowego w celu opisu temperatury na wyjściu z kolektora dla naturalnej zmienności godzinowej natężenia promieniowania słonecznego oraz dla kilku wybranych prędkości przepływu medium roboczego. Wykazano, że możliwy jest wystarczająco dokładny opis za pomocą uproszczonego modelu matematycznego koncentratora, jednakże wymagana jest znajomość parametrów technicznych koncentratora (m.in. sprawności odbiornika ciepła, sprawności koncentracji promieniowania i inne). W wielu przypadkach praktycznych dokładne określenie tych wielkości może być trudne. Dlatego przeprowadzono analizę czułości modelu na niepewności tych parametrów.
EN
The importance of developing solar cooling technologies was described in the paper. Described system mostly use additional heat source to achieve temperature sufficient for efficient operation of an absorption unit. In this aim, in many of the installation such auxiliary heat sources as: electric, gaseous, etc are applied. This heat source use non-renewable energy. In the countries of the south operation of the system using only renewable energy is possible - it require large areas of evacuated tube collectors. However, in Poland solar installations are mostly smaller and based of flat plate solar collectors. Therefore in this paper we consider system based on flate-plate collectors with heating up of working medium by a solar concentrator. Description of the experimental hybrid installation and selected results for variable medium flow are presented in the paper. It was confirmed that it is possible create sufficiently accurate description of the installation by simplified mathematical model, but it requires knowledge of some technical parameters as: efficiency of the heat receiver, concentrating ratio and others. In many practical cases accurate determination of those parameters is difficult. Appropriate anylysis of sensitivity of those parameters were performed.
PL
W artykule zaprezentowano zastosowanie na dużą skalę w budynkach biurowych chłodziarek absorpcyjnych zasilanych z miejskiej sieci ciepłowniczej z źródła wyposażonego w akumulator ciepła. Analizowano wpływ zainstalowania chłodziarek absorpcyjnych na poprawę efektywności energetycznej dostawy i produkcji ciepła w określonym miejskim systemie ciepłowniczym. Analizę przeprowadzono na bazie danych eksploatacyjnych z zespołu budynków biurowych oraz obliczeń zużycia ciepła przy uwzględnieniu modernizacji węzła cieplnego budynku na węzeł cieplno – chłodniczy produkujący chłód przy pomocy chłodziarek absorpcyjnych. Zaprezentowano także przebiegi średnich dobowych i miesięcznych zapotrzebowań na ciepło do celów ogrzewania oraz produkcji chłodu do celów klimatyzacyjnych i ich wpływ na poprawę efektywności energetycznej miejskiej sieci ciepłowniczej z akumulatorem ciepła zainstalowanym w źródle.
EN
The paper is concerned with the application on large scale of the absorption chillers (AAC), supplied with heat from the District Heating System (DHS) with the Thermal Energy Storage (TES). The absorption chillers transform heat and produce cool for office buildings air conditioning. The analysis was performed based on data from existing office buildings and calculation of thermal energy usage, taking into account the modernization of the office building thermal substation to thermal / cooling one - producing both, heating and cooling capacities. Heating capacity is utilized to produce domestic hot water (d.h.w.) and for central heating (c.h.), while cooling capacity for air conditioning (AC). Curves for daily and monthly average heat demand of the office buildings for heating and cooling purposes and their impact on the DHS with the TES installed in the Combined Heat and Power (CHP) plant were also presented.
EN
The growing demand for electricity and declining fossil fuel resources reduce the availability of energy for the future generations, which is a major threat in the context of sustainable development principle. Currently in Europe more than 50% of electricity comes from coal burning thermal plants. According to data from Europe’s Energy Portal such a rapid exploitation of this energy carrier may cause that it will not be available approximately after 2140. Because of this situation, the duty of the present generation is to improve efficiency of energy use and energy production and to enhance the contribution of alternative sources in general energy demand. This is compliant with the sustainable development principle. According to some researcher a huge potential is in field of cooling generation. About 95% of all installed cooling devices are traditional compressor chillers, which are powered by electricity. In this situation absorption chillers appear to be a good alternative. They are thermally activated appliance powered by heat. That’s create a great opportunity to use energy from renewable resources or waste heat from technological processes. Absorption chillers may cooperate with many heat sources. One of the possibility is the creation of solar cooling system powered by solar energy. In this kind of system absorption device use hot water from solar collectors to initiate refrigeration cycle. It is a very interesting solution, because the biggest cooling demand occurs at the same time as the highest solar radiation is available. Moreover, the sun is the biggest source of energy on the Earth. In terms of solar radiation intensity Poland has quite good conditions. The amount of light received every year is between 950–1250kWh/m2. And about 80% of this value accounts for the warm period of the year from April to September. Absorption chillers has much lower coefficient of performance (COP=0,6–1,2) comparing to compressors chillers (COP=3–5). But they consume much less electricity, which is one of the biggest advantages of this technology. In this paper evaluation and comparison of absorption and compressor chillers used for chilled water production for air conditioning purpose are presented. In case of solar absorption cooling, solar energy contribution to cover energy demand is more than 80%. Operation phase of absorption chiller appears to consume less electrical energy (12 596 kWh) than compressor chiller (20 671 kWh), thus the total GHG emission is associated with this unit and is 6 221 kg CO2e for absorption chiller and 10 209 kgCO2e for compressor chiller.
PL
W artykule zaprezentowano ogólną charakterystykę źródeł skojarzonego wytwarzania energii elektrycznej, ciepła i chłodu (trójgeneracja lub CHCP) ze szczególnym naciskiem na wpływ zmiany parametrów pracy chłodziarki absorpcyjnej na pracę całego źródła. Przedstawiono także podstawowe strategie i kryteria optymalizacyjne pracy źródła. Analiza została przeprowadzona bazując na dostępnych materiałach dotyczących wpływu zmiany przykładowych parametrów pracy chłodziarki absorpcyjnej na pracę całego źródła oraz opracowaniach własnych. Przeprowadzono także analizę korzyści związanych z możliwością poprawy sprawności wytwarzania chłodu przez chłodziarkę absorpcyjną pracującą na potrzeby klimatyzacyjne budynku biurowego.
EN
Paper presents an overview of combined heating, cooling and power sources (called trigeneration or CHCP) considering the impact of absorption chiller working parameters change on energy source. Analysis was conducted basing on available data and technical materials on impact of cogeneration and absorption units parameters change. Basic CHCP working strategies with optimization algorithms were presented and preliminary assessment of possibilities of improving absorption chiller efficiency by decreasing cooling water temperature was also conducted.
PL
W artykule przeprowadzono analizę działania chłodziarki absorpcyjnej charakteryzującej się małym zapotrzebowaniem na moc elektryczną. Chłodziarka posiada wbudowane palenisko gazu ziemnego, a cykl chłodniczy realizowany jest dzięki wykorzystaniu energii cieplnej powstałej w procesie spalania gazu. Efekty środowiskowe działania chłodziarki absorpcyjnej zostały porównane z efektami uzyskanymi dla chłodziarki sprężarkowej zasilanej wyłącznie energią elektryczną. Do przeprowadzenia analizy wykorzystano metodologię środowiskowej oceny cyklu życia dla fazy użytkowej systemów. Analiza wykazała, że lepszym rozwiązaniem jest stosowanie chłodziarki absorpcyjna zasialanej gazem ziemnym.
EN
In this paper an analysis of absorption chiller performance, characterized by a low demand for electric power, is presented. The absorption chiller is equipped with built-in natural gas combustor. The refrigerant cycle is realized by utilizing thermal energy generated during gas combustion. Environmental effects of absorption chillers performance were compared with the effects obtained for compression refrigerator powered by electricity. For the conducted operation analysis a methodology of environmental life cycle assessment was used. The analysis proved, that better solution is using gas fired absorption chiller.
PL
Koncepcja rozwoju zrównoważonego, mówiąc o konieczności zapewnienia podstawowych potrzeb obecnego i przyszłych pokoleń, odnosi się m.in. do problemu dostępności i wyczerpywalności nośników energii. Coraz większy nacisk kładziony jest na zwiększenie efektywności procesów wytwarzania energii oraz jej zużycia. Istotne znaczenie ma również rozwój technologii korzystających z odnawialnych źródeł energii, których zastosowanie ma spowodować zwolnienie tempa zużycia tradycyjnych, kopalnych nośników energii. Wpływ środowiskowy technologii alternatywnych wiąże się nie tylko z samymi efektami eksploatacyjnymi. Ważne jest tu sprawdzenie potencjalnych wpływów na środowisko w całym cyklu życia danej technologii, poczynając od jej wytworzenia aż do likwidacji. W pracy przeanalizowano efekty zastosowania chłodziarki absorpcyjnej w danym układzie klimatyzacyjnym oraz koszty jej wytworzenia i użytkowania w aspekcie środowiskowym z wykorzystaniem techniki Oceny Cyklu Życia (LCA).
EN
The sustainable development concept, discussing the needs of present and future generations, is inter alia referring to the problem of accessibility and exhaustion of energy carriers. The growing demand for electricity and declining fossil fuel resources reduce the potential availability of energy for the future generations. Therefore, improvement of energy efficiency use and energy production is needed as well as promotion of renewable energy use leading to reduction in consumption of traditional energy carriers. The environmental impact of alternative technologies is not associated with the operational effects only. The potential environmental impacts throughout the lifecycle of the technology must be also assessed - from its manufacture to decommissioning. In this papers an assessment of the absorption chiller performance is presented and the environmental aspects of its manufacture and use are assessed with the technique of Life Cycle Assessment (LCA).
PL
Cynk produkowany jest głównie w procesie pirometalurgicznym wykorzystującym technologię Imperial Smelting Process (ISP). W procesie tym wyróżnia się dwa główne etapy: przygotowanie spieku i przetop redukcyjny spieku w piecu szybowym. Produktem ubocznym procesu wytwarzania cynku jest gaz poredukcyjny z pieca szybowego. Gaz ten zanieczyszczony pyłami ma wartość opałową na poziomie 3 do 3,8 MJ/Nm3. Obecnie gaz ten jest wykorzystywany w na-grzewnicach dmuchu, a jego nadmiarowa ilość jest dopalana i uwalniana do atmosfery. W pracy przedstawiono możliwości zagospodarowania nadmiarowych ilości gazu poredukcyjnego. Poza zwiększeniem zużycia gazu w nagrzewnicach istnieje możliwość wykorzystania go w obiegu turbiny gazowej lub do zasilania stacjonarnych silników wewnętrznego spalania. Ponadto przeanalizowano możliwości produkcji chłodu poprzez zastosowanie absorpcyjnych urządzeń chłodniczych. W artykule przedstawiono szczegółową analizę możliwości wykorzystania gazu z pieca szybowego dla warunków huty cynku.
EN
Zinc is mainly produced in the pirometalurgical process that uses Imperial Smelting Technological Process (ISP). In this process, two main phases can be distinguished: preparation of sinter and reductive fusion of sinter in a shaft furnace. A by-product of zinc production process is low-calorific dust-containing gas from the shaft furnace. The lower heating value of the gas is about 3-3.8 MJ/Nm3. Currently, by-produced gas is commonly used in the blast heaters, and the excess is combusted and released into the atmosphere. The paper presents possibilities of low-calorific by-produced gas utilization to generate both electricity and heat in the gas turbine and internal combustion engines. Moreover the possibility of gas utilization to produce coolness in absorption chillers is presented. The paper presents a detailed analysis of usability of by-produced gas from shaft furnace for zinc smelter conditions.
PL
Przez wzgląd na szerokie możliwości wykorzystania i zastosowań urządzeń absorpcyjnych, zwłaszcza w obecnych warunkach ekonomicznych, przedstawiono analizę numeryczną układów, które w sposób skojarzony wytwarzają chłód. Prezentowane analizy uzyskano w toku symulacji komputerowych w oparciu o własny zweryfikowany kod obliczeniowy, bazujący na integralnych równaniach zachowania CFM. Zamieszczono analizy i porównania efektywności pracy układu absorpcyjnego pracującego zarówno w skojarzeniu z urządzeniem sprężarkowym jedno- i dwustopniowym. Zaprezentowano również rzeczywisty przykład nowoczesnego układu skojarzonego, pracującego w KWK Pniówek.
PL
W niniejszej publikacji zostało omówione zastosowanie innowacyjnych technik chłodniczych, a zwłaszcza chłodziarek absorpcyjnych w przemyśle. Techniki te umożliwiają: wykorzystanie energii odpadowej w układach indywidualnych i sprzężonych, chłodzenie powietrza przed sprężaniem, zarówno wstępne jak i międzystopniowe. Wskazano tutaj także na możliwość chłodniczego odwadniania odpadów.
16
PL
W referacie przedstawiono możliwości uzyskiwania podczas natryskowego nakładania powłok malarskich wysokiej jakości wyrobów, przez zastosowanie ogrzewania sprężonego powietrza, eliminując w ten sposób zjawisko wykraplania się wilgoci na powlekanych powierzchniach. Przedstawiono rozwiązania układów przygotowania sprężonego powietrza z wykorzystaniem ciepła odpadowego oraz za pomocą chłodziarki absorpcyjnej. Zastosowanie chłodziarki absorpcyjnej umożliwia nie tylko głębokie ochłodzenie sprężonego powietrza powodując maksymalne wykropIenie wilgoci, ale daje również możliwość wykorzystania ciepła skraplania i absorpcji do ogrzania sprężonego powietrza przed stanowiskami pneumatycznego powlekania.
EN
Using heated compressed air aIIows to get high quaIity surfaces during spray coating. This way lets eliminate humid releasing phenomenon on coated surfaces. The compressed air conditioning lay-outs with using waste heat and an absorption refrigerator is discussed in the article. Using the absorption refrigerator aIIows the compressed air not only to be cooled deeply, which causes maximum humid releasing, but also gives the capability to use the heat of condesation and absorption in order to heat compressed air before the pneumatic coating in the production plant.
EN
This paper describes the development and investigation of three single-effect hot-water driven, solar thermal powered diffusion absorption cooling machines (DACM) each with a design cooling capacity of 2.5 kW. The first DACM prototype showed that the values of COP ranged from 0.10 to 0.20, and the evaporator cooling capacity could reach 1.5 kW. However, the auxiliary gas circulation of the first prototype was not high enough, leading to fast saturation of evaporated ammonia. The second compacted prototype showed stable and continuous temperature and pressure levels. The reached COPs were between 0.2 and 0.45 and the continuous cooling performance was between 1.0 kW and 1.6 kW. A third prototype with marketable dimensions was set up in October 2005. The results showed cooling capacities between 0.7 kW and 3.0 kW. The reached COPs are between 0.12 and 0.38.
PL
W pracy przedstawiono model oraz badania 3 kolejnych prototypów chłodziarki absorpcyjnej wykorzystującej energię słoneczną. Urządzenie posiada moc chłodzenia równą 2,5 kW. Opracowano model w warunkach pracy ustalonej chłodziarki, który wykazuje dobrą zgodność z wynikami badań.
18
Content available remote Using solar energy to supply an absorption chiller
EN
Using solar energy leads to decreasing of electricity consumption and to reduced use of coolants being harmful to the ozone layer. In addition, the use of solar energy for cooling in HVAC systems becomes more and more common. This is possible primarily in sunny climates. The water used for lowering temperature and humidity during the summertime as a rule is cooled with the common compression refrigerators. For this purpose solar collectors with ammonia or lithium-bromide chillers can be used. The desorber of such absorption chiller is supplied with hot water obtained from solar collectors. In this paper a simulation of absorption ammonia chiller powered from solar collectors is presented.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.