Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  atomic absorption spectroscopy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper examines the impact of protective equipment used during the COVID-19 pandemic on the environment. The impact of protective face masks on the aquatic environment was analyzed in more detailed way. The amount of protective face masks penetrated into the environment as a result of the COVID-19 pandemic and their role in the increase of plastic and microplastic things in the environment was noted. The aim of the work was to study the migration of a number of metals from disposable protective masks into the aquatic environment in the short term. Using the method of atomic absorption spectroscopy, the value of Cu, Pb, Mn, Zn, Fe in the investigated model systems containing protective disposable face masks was obtained by varying the pH of the aqueous medium. It was found that for manganese, lead and iron there is a permanent (Mn) or temporary (Pb, Fe) excess of these metals in the aquatic environment according to national and European standards. The probable possibility of sorption effects and the need for further research in this direction were noted.
EN
Pylaisia polyantha moss growing near intensive traffic in Geležinis Vilkas street at Vingis Park (Vilnius) was selected as an indicator of environmental pollution. Two models were applied for the study: the Gaussian plume model – for zinc emission from automobiles calculation and mathematical model – for recalculating the zinc emission from transport to zinc concentration in moss. Moss samples were collected during spring, summer and autumn. There were no significant changes in Zn concentrations between these periods. Zn emission dispersion from pollution source was calculated only for one vehicle, in order to reach relationships between environmental conditions and dispersion of Zn emission from vehicle exhaust fumes pipe. It was detected that the concentration of Zn tends to decrease with the distance from the pollution source. It was observed that there was a strong relationship between wind speed and Zn concentration – the slower the wind speed, the higher concentration of zinc in moss.
PL
W niniejszej pracy dokonano analizy wpływu czasu składowania hałd na zawartość wybranych pierwiastków metali ciężkich. Badanym materiałem były dwie hałdy szlamów i osadów pofiltracyjnych z oczyszczania gazów odlotowych, które różniły się czasem składowania. Analizowano je pod kątem wilgotności oraz zawartości cynku, manganu i chromu wykorzystując metodę absorpcyjnej spektroskopii atomowej. Hałda "Dąbrowa Stara", która pochodzi z przełomu roku 2020/2021 wykazała wilgotność na poziomie 39%. Natomiast hałda "Dąbrowa Nowa" została dostarczona we wrześniu 2021 r. i charakteryzowała się wilgotnością 47%. Otrzymane zawartości wody w próbkach zgadzają się z przedziałem otrzymanym przez firmę dla tego rodzaju surowca (30-50%). Badanie zawartości metali ciężkich wykazało największe stężenie cynku ze wszystkich oznaczanych pierwiastków, wyniosło ono dla próbki „Dąbrowa Stara” 17119 [μg/g], a dla próbki „Dąbrowa Nowa” 20385 [μg/g]. Najmniejszą ilość w badanych materiałach stanowił chrom, którego zawartość była nieznaczna. Dla próbki „Dąbrowa Stara” wartość oznaczonego stężenia wyniosła 127 [μg/g], a dla „Dąbrowa Nowa” 150 [μg/g]. Wykazano, że hałda "Dąbrowa Nowa" jest bardziej bogata w cynk, chrom i mangan niż hałda "Dąbrowa Stara". Różnice w zawartościach wykrywanych składników mogły być efektem wymywania ich np. poprzez opady deszczu co było spowodowane różnym czasem składowania obu hałd.
EN
In this publication, the effect of heap storage time on the content of the selected heavy metals was analysed. Two heaps of sludges and filter sludges from waste gas treatment, which differed in storage time, constituted the studied material. They were analyzed for moisture content and zinc, manganese and chromium concentrations using atomic absorption spectroscopy. „Dąbrowa Stara” heap, which dates back to the turn of 2020/2021, showed moisture content of 39%. The „Dąbrowa Nowa” heap, on the other hand, was delivered in September 2021 and had a moisture content of 47%. The obtained water contents in the samples agreed with the range obtained by the company for this type of raw material (30- 50%). The analysis of heavy metal contents showed the highest concentration of zinc of all determined elements, which was 17119 [μg/g] for the sample "Dąbrowa Stara" and 20385 [μg/g] for the sample "Dąbrowa Nowa". Chromium was the least abundant in the studied materials and its content was insignificant. For the sample "Dąbrowa Stara" the value of determined concentration was 127 [μg/g], and for "Dąbrowa Nowa" 150 [μg/g]. It was shown that the „Dąbrowa Nowa” is richer in zinc, chromium and manganese than the „Dąbrowa Stara”. The differences in the contents of the detected components could be the effect of their leaching e.g. by rainfall, which was caused by the different time of storage of the two heaps.
PL
W pracy przedstawiono wyniki oznaczenia zawartości wybranych metali ciężkich w pięciu preparatach kolagenowych metodą atomowej spektrometrii absorpcyjnej (AAS). Śladowe ilości arsenu w dwóch pierwszych próbkach oraz brak innych toksycznych metali ciężkich, tj. chromu, kadmu, ołowiu i rtęci we wszystkich badanych próbkach kolagenowych pozwala na bezpieczne ich stosowanie w rolnictwie. Obecność cynku i miedzi w tych preparatach może przyczynić się do poprawy kiełkowania otoczkowanych preparatami kolagenowymi nasion rzepaku.
EN
The paper presents the results of determining the content of selected heavy metals in five collagen preparations by atomic absorption spectrometry (AAS). Trace amounts of arsenic in the first two samples and the absence of other toxic heavy metals, i.e. chromium, cadmium, lead and mercury in all collagen samples tested allow their safe use in agriculture. The presence of zinc and copper in these preparations may contribute to the improvement of germination of rapeseed coated with collagen preparations.
PL
Pomimo rosnącego zainteresowania metodami analitycznymi opartymi na użyciu cieczy jonowych ich sprzężenie wraz z techniką mikroekstrakcji do pojedynczej kropli nie osiągnęło zadowalającej popularności oraz akceptacji ze strony środowiska naukowego.
6
PL
Praca dotyczy oznaczania zawartości metali ciężkich takich jak ołów i kadm w warstwie wierzchniej i spodniej gleby. Próbki analizowanej gleby pochodzą z obszarów przemysłowych zlokalizowanych niedaleko Olkusza w województwie małopolskim. Jako metodę oznaczenia wspomnianych wyżej metali zastosowano woltamperometrię stripingową różnicową oraz atomową spektroskopię absorpcyjną. Dodatkowo zbadano zależność pomiędzy zawartością ołowiu, a pH gleby. Główny cel pracy to analiza zawartości ołowiu i kadmu w pionowym profilu przekroju gleby i skorelowanie uzyskanych wartości stężeń z pH gleby.
EN
This work concerns the study of heavy metals such as lead and cadmium in the top and bottom layers of the soil. The samples come from industrial areas located near Olkusz in the Małopolska. Concentrations of the selected elements were determined with stripping voltammetry and atomic absorption spectroscopy. In addition, the relationship between the lead concentration and pH of the collected soil samples was examined. The main objective was to compare the concentration of heavy metals in the soil profile and to correlate it with the soil pH value.
PL
W pracy przedstawiono wyniki oznaczenia zawartości wybranych metali w kolagenowych preparatach handlowych metodą atomowej spektrometrii absorpcyjnej (AAS). Pierwiastki wykryte w analizowanych preparatach to: Ca, Fe, Mg, Zn. Najwyższe stężenia wapnia odnotowano dla próbki kolagenu odmiany 3W (K3W (1518,71 mg/kg)). Stężenie tego pierwiastka było o połowę niższe w próbce kolagen 3 (K3-717,95 mg/kg) i kolagen odmiany 2 (K2-677,13 mg/kg). Próbki kolagenu odmiany 3 (K3-194,98 mg/kg) oraz kolagenu odmiany 5 (K5-178,57 mg/kg) odznaczały się najwyższym stężeniem magnezu. Największą zawartość żelaza oznaczono w próbce kolagenu odmiany 5 (K5-187,35 mg/kg), a najwyższą zawartość cynku oznaczono w kolagenu odmiany 3W (K3W-59,50 mg/kg). Metale określane jako składniki bioaktywne: Ca, Mg, Zn mają duży wpływ na zdrowie i piękno skóry. W przebadanych próbkach preparatów kolagenowych nie wykryto natomiast następujących metali: Ag, Al, Ba, Cd, Cr, Cu, Li, Mn, Ni, Pb.
EN
The paper presents the results of the determination of the content of selected metals in collagen commercial preparations by atomic absorption spectrometry (AAS). The elements detected in the analyzed preparations are: Ca, Fe, Mg, Zn. The highest calcium concentrations were recorded for the 3W collagen sample (K3W (1518.71 mg/kg), the concentration of the element was half as high in the collagen 3 sample (K3-777.95 mg/kg) and collagen 2 (K2-677.13 mg/kg). Samples of collagen variety 3 (K3-194.98 mg/kg) and collagen strain 5 (K5-178.57 mg/kg) were characterized by the highest concentration of magnesium, the highest content of iron was determined in the sample of collagen 5 (K5 -187.35 mg/kg), and the highest zinc content was determined in collagen of the 3W variant (K3W-59.50 mg/kg). Metals referred to as bioactive components: Ca, Mg, Zn have a big impact on the health and beauty of the skin. The following metals were not detected in the tested collagen preparations: Ag, Al, Ba, Cd, Cr, Cu, Li, Mn, Ni, Pb.
PL
W artykule scharakteryzowano metodę absorpcyjnej spektrometrii atomowej wykorzystującą automatyczny analizator rtęci AMA 254 jako jedną z technik pomiarowych zawartości rtęci. Zwrócono szczególną uwagę na zasadę działania analizatora rtęci AMA 254, jego precyzję oraz granicę oznaczalności stosowanego urządzenia. Dokonano szereg pomiarów materiału odniesienia, zwalidowano metodę, a następnie oznaczono zawartość rtęci w wielu surowcach stosowanych w przemyśle budowlanym. Porównano otrzymane wyniki z obowiązującymi aktami prawnymi oraz z danymi dostępnymi w literaturze.
EN
The article describes the method of atomic absorption spectrometry using an automatic mercury analyzer AMA 254 as one of the techniques of measuring the mercury content. Special attention is paid to the mercury analyzer AMA 254 principle of operation, its precision, and the analyzer limits of quantification. There have been a series of the reference material measurements, Methods was validated. Then many raw materials and products used in the construction industry was analyzed for mercury content. We compared these results with the prevailing laws and the data available in the literature.
PL
Ze względu na ogromną toksyczność rtęci oraz zagrożenia wynikające z występowania jej związków w środowisku, niezwykle ważne jest wybranie odpowiedniej procedury analitycznej, która umożliwiałaby oznaczenie bardzo niskich stężeń rtęci w próbkach paliw.
EN
Lead is an important constituent widely used in different industrial processes. For evaluation of workers’ exposure to trace toxic metal of Pb (II), solid-phase extraction (SPE) was optimized. SPE using mini columns filled with XAD-4 resin was developed with regard to sample pH, ligand concentration, loading flow rate, elution solvent, sample volume, elution volume, the amount of resins, and sample matrix interferences. Lead ions were retained on a solid sorbent and then eluted, followed by a simple determination of analytes with flame atomic absorption spectrometery. The obtained recoveries of metal ions were greater than 92%. This method was validated with 3 different pools of spiked urine samples; it showed a good reproducibility over 6 consecutive days as well as 6 within-day experiments. This optimized method can be considered successful in simplifying sample preparation for a trace residue analysis of lead in different matrices when evaluating occupational and environmental exposures is required.
13
Content available remote Determination of wear products in oils by atomic absorption spectroscopy (AAS)
EN
Direct involvement of lubricants in contact processes inside tribological systems with a basic task to stop direct interaction between surfaces of elements gives them a special role from the aspect of maintenance. This role is even more important if we know that lubricants are information carriers on overall condition of the system where special attention is paid to the processes effecting functionality, reliability, and durability. The importance of this information is particularly noticeable during monitoring and system diagnostics because the analysis of oil can detect signs of potential problems leading to failure and allow an insight into the effects of lubricants on system functioning. The paper shows the analysis of atomic absorption spectroscopy method (AAS) and an overview of test results regarding concentration of wear products in transmission and motor oils during synchronization to durability system tests.
PL
Olej smarowy w styku tribologicznym nie tylko oddziela powierzchnie elementów węzła tarcia, ale także jest nośnikiem ważnych informacji. Jest to szczególnie istotne podczas monitorowania i diagnozowania systemu, ponieważ dzięki analizie stanu oleju można wykryć symptomy potencjalnych problemów, a w konsekwencji zapobiec nieprawidłowościom w funkcjonowaniu systemu tribologicznego. W pracy omówiono wyniki badań AAS zawartości cząstek zużycia wolejach przekładniowych i silnikowych podczas testów zużyciowych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.