EN
Purpose : Exerting axial pressure on the affected lower limb remains one of the most crucial elements of Ilizarov method . Objective was to determine the effects of an early intrahospital rehabilitation on weight bearing during lower extremity lengthening with Ilizarov`s Method. Methods: Study included 15 patients who underwent lower limb lengthening. The patients were tested on the third day after surgery using the pedobarographic platform. The tests were performed four times in the standing position:twice with the support of forearm crutches and twice without crutches. Patients were asked to either remain in the relaxed standing position(two tests) or use the lower limb equipped with Ilizarov apparatus to support the body weight(two tests). Results: In relaxed stance average pressure with forearm crutches was 24.1% for affected limb, as compared to 75.9% for the healthy limb. In test without forearm crutches average pressure for affected limb was 26.1%, as compared to 73.9% for the healthy limb. Patients shifted body weight to the affected limb with forearm crutches on average, at the rate of 53.6% . In test without forearm crutches the affected limb was supporting the body weight at the rate of 48.26%. None of the patients was able to fully support the body weight on the affected leg. Conclusions: In spite of strict physiotherapy regimen,patients are, neither able to equally distribute their body weight between the two lower limbs ,nor to shift their body weight to the limb equipped with Ilizarov apparatus.
EN
We present a new manipulative robotic system with 1 degree of freedom designed for increasing of the knee rehabilitation efficiency in case of patients with the femur distraction osteogenesis with use of Ilizarov apparatus. Based on the conducted analysis of the knee’s anatomy, biomechanical functionality of knee-joint and characteristics of considered medical treatment, overall assumptions concerning robotic assistance in knee rehabilitation process are formulated. Then we propose a simplified kinematic structure based on one rotational fixed axis taking into accountguidelines resulting from specificity of complications following a femur distraction osteogenesis with use of Ilizarov apparatus. The paper presents description of mechanical and measurement system for a considered manipulative robot. The issues regarding patient’s safety while realization of robotic rehabilitation are also discussed. Additionally, motion control and force control design issues are considered and some preliminary experimental results are presented.
PL
W pracy przedstawiono założenia oraz wstępną konstrukcję manipulatora rehabilitacyjnego dla stawu kolanowego. Zaproponowany system będzie wykorzystywany przez chorych w wieku od 6 do 18 lat, u których prowadzone jest wydłużanie kości udowej z zastosowaniem aparatu Ilizarowa. W pracy zamieszczono również wstępne badania, które przeprowadzono przy pomocy systemu Biodex. Polegały one na przeprowadzeniu testów izometrycznych i izotonicznych na pacjentce w wieku 16 lat.
EN
The paper presents the assumptions and design of the knee rehabilitation manipulator. This system will be used by young patient who experenced a lengthening of the femur using the Ilizarov apparatus. Paper presents a preliminary research using the Biodex system. Results consist of isometric and isotonic tests, which was conducted.
PL
Praca prezentuje nietypowe ujęcie problemu wyznaczania sztywności aparatu Ilizarowa zawierającego druty Kirschnera oraz wkręty Schanza. Opracowana metoda obliczeń nie wymaga zastosowania metody elementów skończonych, a jedynie wykonania prostych eksperymentów i obliczeń. Niezbędne w analizie parametry opisujące podatność pierścieni Ilizarowa wyznaczano eksperymentalnie. Istotnym rozwinięciem, w stosunku do wcześniejszych prac jest opracowanie analitycznej metody opisu współpracy pierścieni Ilizarowa z wkrętami Schanza uwzględniającej podatność wszystkich elementów aparatu.
EN
This paper presents an uncommon solution to the problem of acquiring the value of stiffness of the Ilizarow apparatus that consists of Kirschner wires and Schanz screws. The proposed method does not require the application of the Finite Element Method, as the only necessary requirement is the execution of a few basic experiments and calculations. The parameters defining the sensibility of the Ilizarow rings are acquired through the experimental means. A significant improvement in comparison to the earlier works in this field is the derivation of the analytical method for describing the cooperation of Ilizarow rings and the Schanz screws, with regard to the sensibility of all the apparatus’ elements.
PL
W pracy przedstawiono nakładkę do programu ANSYS umożliwiającą prowadzenie szybkich obliczeń jak również optymalizację wybranych układów aparatu Ilizarowa. Praca przedstawia praktyczną realizację idei budowy pakietu obliczeniowego pozwalającego na szybki montaż modelu obliczeniowego układu aparatu Ilizarowa z zespołu przygotowanych, szeroko stosowanych elementów, bazując na dwóch pierścieniach. Aplikacja prowadzi użytkownika przy tworzeniu modelu obliczeniowego aparatu, pozwalając wybrać oczekiwaną opcję oraz zapewnia uzyskanie wyniku - podatności układu w czasie kilku sekund.
EN
This paper treats about a cooperating with ANSYS application, which enables fast analysis and optimization of chosen configurations of Ilizarov apparatus. Idea of an engineering software providing fast modeling, using common elements and basing on two rings is presented. User is carried through designing a model, choosing options and in the end getting results - compliance of the chosen configuration of Ilizarov apparatus in just a few seconds.
EN
The influence of the building and mineralization of the new bone tissue in the distraction crevice, on the general decrease of strain levels in telescopic rods, due to the bone structure taking over support of some portion of weight is a very interesting issue. The change of bone rigidity (EA, EJ) from zero up to a normal healthy bone makes such evaluation or further interpretation of results virtually possible. This is possible by observation of drop of strain in telescopic rods when the new bone tissue starts to carry the main load of body mass and muscle force.
8
Content available remote Possibility of using polyamide 6 reinforced by glass fibres for Ilizarov rings
EN
In work presented and estimated possibilities of using a polyamide composite modified by fibers for a rings of Ilizaroy apparatus. It was presented also a results of mechanical tests of rings.
PL
W pracy przedstawiono i oceniono możliwości zastosowania kompozytów PA6 napełnianych włóknami do wytworzenia pierścieni aparatu Ilizarova oraz pokazano wyniki przeprowadzonych badań ich właściwości mechanicznych.
PL
W leczeniu schorzeń narządu ruchu stosuje się coraz częściej stabilizację zewnętrzną w tym metodę Ilizarowa. Metoda Ilizarowa znalazła szerokie zastosowanie w ortopedii. Stosuje się ją w wydłużeniach kończyn, przy skomplikowanych wrodzonych wadach narządu ruchu, w leczeniu złamań i powikłań zrostu kostnego. Wielokrotnie powtarzane badanie rentgenowskie jest konieczne dla oceny przebiegu leczenia. Istotną przeszkodę w tej obserwacji stanowią metalowe elementy stabilizatora uniemożliwiające dokładny wgląd w strukturę kości. Zewnętrzny stabilizator Ilizarowa składa się z różnej średnicy pierścieni mocowanych do kości za pomocą drutów Kirschnera, a następnie połączonych nagwintowanymi prętami, uzupełnionymi w razie konieczności zawiasami. W większości przypadków dwupłaszczyznowe zdjęcia RTG wystarczają do oceny przebiegu leczenia. Jednak w wątpliwych przypadkach, zwłaszcza gdy mamy do czynienia z zaburzeniem zrostu złamanej kości musimy posiłkować się innymi metodami techniki obrazowej. W Klinice i Katedrze Ortopedii AM badaniem z wyboru w takich przypadkach jest Tomografia Komputerowa (TK). Pozwala ona na dokładniejszą prezentację blizny kostnej jednak na ocenę niekorzystnie wpływają elementy metalowe aparatu, szczególnie pierścienie. W klinice i Katedrze Ortopedii AM w przeciągu ostatnich trzech lat wykonano 42 badań TK celem określenia postępu zrostu kostnego. Diagnostyczny wynik uzyskano w 35 Przypadkach, w 7 przypadkach był on wątpliwy z uwagi na bardzo liczne artefakty metalowe.
EN
External stabilization with Ilizarow apparatus widely used method in modern orthopedics. It is indicated in limbs elongation, treatment of complicated congenital limbs malformation as well as in the agement of fractures and synostosis complications. Multiple X-ray examinations are essential for proper monitoring of the treatment. However metal build elements of the device make the appropriate assessment of bone structure very difficult. External stabilizer consists of steel rings of different diameter fastened to the bone by Kirschner's wires and connected to each other by iron rods and hinges. In most cases biplane X-ray examination is sufficient for the monitoring of the treatment. In questionable cases e.g. in patients presenting with disturbances in the umion of the fractured bone additional imaging modalities are required for the correct evaluation. In the Department of Orthopaedics and Traumatology computed tomography (CT) is a method of choics in such cases. CT imaging allows accurate assessment of the bone scar, however the exact evaluation is substantially hampered by steel elements especially the rings of the Ilizarow apparatus. In last three years in our Department we conducted 42 CT scans to evaluate the union of the fractured bones. Images of good quality, allowing the proper diagnosis were obtained in 35 cases. In 7 cases the result was questionable due to extensive artifacts.
PL
W pracy przedstawiono wspomaganą komputerowo metodę pomiaru siły wydłużania kończyn, występującej w prowadnicach aparatu Ilizarowa. Podano idee, ulepszonej metody pomiaru, eliminującej ograniczenia i błędy sposobu stosowanego dotychczas. Zaprezentowano budowę specjalnego czujnika zastosowanego w pomiarach i analizę dokładności wykonywanych pomiarów. Opisano tor pomiarowy i program obsługi pomiarów. Zamieszczono wydruki przykładowych przebiegów zmierzonych wartości.
EN
The paper presents a computer-aided method for measuring the limb lengthening force appearing in the Ilizarov's apparatus sideways. An idea of improved measurement method eliminating deficiencies and errors of the hitherto used manner has been presented. Moreover, a structure of a special measuring element and an analysis of measurement accuracy have been shown. The measuring system and possibilities of tool software have been described. Some example diagrams of measured force values has been inserted.