Although the multitude benefit of wind power, the randomness of wind speed and the fluctuations of wind power are the most disadvantages of wind energy. So, for more efficiency and better performances, wind rotor must be driven at specific optimal rotational speed under each particular wind speed. Therefore, to extract the maximum power from wind turbine, a Maximum Power Point Tracking (MPPT) controller is required. In this paper, modeling of wind energy conversion system WECS using tip speed ratio (TSR) MPPT controller using PID controller tuned by genetic algorithm is investigated. The wind energy conversion is based on a doubly-fed induction generator (DFIG), which it is controlled by robust sliding mode control technique using a generator of 3.6 MW . The obtained results are presented and analyzed, where the performances of both proposed control strategies (MPPT based PID-GA, sliding mode control) have been shown.
PL
W pracy przedstawiono system energii wiatrowej wykorzystujący sterownik śledzący szcztową prędkość . W sterowniku zastosowano regulator PID strojony z wykorzystaniem algorytmu generycznego. Jako generator wykorzystano układ DFIG sterowany za pośrednictwem sterownika ślizgowego.
PL
W referacie zaprezentowano możliwości sterowania produkcją energii elektrycznej farmy wiatrowej przyłączonej do sieci rozdzielczej 110 kV, na przykładzie elektrowni wiatrowej Kamieńsk o mocy zainstalowanej 30 MW. Na podstawie doświadczeń wynikających z trzyletniego okresu eksploatacji elektrowni przedstawiono szereg trudności ograniczających możliwości zarządzania produkcją i sprzedażą energii elektrycznej. Zaprezentowano systemy stosowane do monitorowania pracy elektrowni wiatrowych oraz systemy wykorzystywane do pomiaru ilości wytwarzanej energii "zielonej" i energii sprzedawanej Operatorowi Systemu Dystrybucyjnego (OSD). Omówiono wpływ rozmaitych czynników o charakterze technicznym na wskaźniki określające dyspozycyjność techniczną oraz produktywność poszczególnych turbin wiatrowych. Sprecyzowano warunki konieczne dla stworzenia możliwości zarządzania energią.
EN
The paper presents the possibilities of controlling electric energy production in a wind power plant, on the example of Kamieńsk wind power plant of 30 MW installed power, connected to 100 kV network. Based on the experience of 3-year period of the power plant exploitation, the series of difficulties is presented, which limits possibilities for the management of energy production and sales. Systems are presented, that are used to monitor the wind power plant operation as well as to measure the amount of produced "green" energy and energy sold to the Distribution System Operator (OSD). The influence of various technical factors on indexes describing the technical availability and productivity of individual wind turbines is discussed. Necessary conditions are specified for creating the possibilities of energy management.
EN
This paper describes two algorithms applied for active and reactive power control in wind turbine driven doubly fed induction generator (DFIG). The first proposed method applies the PI controllers for regulation of DFIG power and the rotor current while the second one utilizes a difference approximation of a given flux derivative. Both algorithms are based on the model description with reference to the stator flux linkage frame. General description of the analyzed methods is delivered and some results of simulations are included.
PL
W artykule przedstawiona jest analiza dwóch algorytmów stosowanych do regulacji mocy czynnej i biernej w elektrowniach wiatrowych z dwustronnie zasilanymi generatorami indukcyjnymi. W pierwszej rozważanej metodzie stosowane są regulatory PI do kontroli mocy i prądu wirnika, podczas gdy w drugiej - całkowanie ciągłe jest aproksymowane za pomocą zależności przyrostowych. W obu algorytmach model maszyny jest zapisany względem układu współrzędnych związanych ze strumieniem stojana. Zamieszczony jest opis rozważanych modeli oraz wyniki przeprowadzonych symulacyjnych testów.
EN
Currently, the use of the doubly-fed induction generators is more and more justified for the aero-generators which develop electric power greater than a few megawatts. These aerogenerators characterized by their variable speed enable to capture the maximum power of the wind and ensure the production of a high quality electric power. The interest of this paper is to control an aero-generator including a doubly-fed induction machine directly connected to the grid at the stator side and via a reversible converter at the rotor site. the state control feedback law is established by considering a third reduced model with stator flux oriented simultaneously assures the dynamic decoupling of the two d-q rotor flux components and eliminates the mechanical transitory oscillations. a neuronal network radial basis function is used to approximate the control law parameters for any varying wind speed and any reactive power being imposed by the power network load flow computation. This control law permits to enhance the robustness stability of the aero-generator for any abrupt fluctuations of the wind speed and to supply the grid at the same time with a high quality of electric power.