Content available Review of X-ray detection systems
EN
The article presents an overview and a classification of X-ray detection methods. The main motivation for its preparation was the need to select a suitable and useful method for detecting signals from a currently developed miniature micro-electro-mechanical system (MEMS) X-ray source. The described methods were divided into passive and active ones, among which can be distinguished: chemical, luminescent, thermo-luminescent, gas ionization, semiconductor, and calorimetric methods. The advantages and drawbacks of each method were underlined, as well as their usefulness for the characterisation of the miniature MEMS X-ray source.
2
Content available remote Przykład wykonania ściany chroniącej przed promieniowaniem rentgenowskim
PL
Artykuł omawia metody wykonania budowlanych osłon przed promieniowaniem, które wykorzystuje się w budowie pomieszczeń diagnostycznych szpitali, przychodni, gabinetów interwencji radiologicznych, sal operacyjnych, placówek medycznych, pomieszczeń przemysłowych i laboratoriów pomiarowych. Zaprezentowane sposoby konstrukcyjnej izolacji przed rozchodzeniem się promieniowania do sąsiadujących pomieszczeń dają gwarancję efektywnej ochrony zdrowia ludzi pracujących lub przebywających w bliskim sąsiedztwie urządzeń, które emitują promieniowanie RTG.
EN
The article discusses methods of building radiation protection, which are used in the construction of diagnostic rooms in hospitals, clinics, radiological intervention rooms, operating theaters, medical facilities, industrial rooms and measurement laboratories. The presented methods of constructional insulation against radiation propagation to neighboring rooms are a guarantee of health protection of people working or staying in close vicinity of devices that emit X-ray radiation.
EN
In this study, the effects of replacing fine aggregate by granulated lead/zinc slag waste (GLZSW) on the thickness of concrete shields against X-ray radiation and on the compressive strength of concrete have been investigated. The fine aggregate was substituted by GLZSW in four percentages: 25%, 50%, 75%, and 100% (by weight). The first aim of the present study was to compare the thicknesses of concretes with GLZSW and control concrete using Lead Equivalent (LE). The second aim was to assess the effects of replacing fine aggregate by GLZSW on the compressive strength of concrete. Results of this study indicated that the compressive strength of mixed concretes increased significantly compared to the control upon replacing fine aggregate by GLZSW; the mixture containing 100% GLZSW had the greatest compressive strength. Further, the inclusion of GLZSW as a substitute for fine aggregate increased the radiation attenuation properties and consequently decreased the thickness of concrete shields in direct proportion to the mixing ratio of GLZSW. The results revealed that concrete mixes containing 100% GLZSW offered the greatest reduction in shield thickness. The study shows that there is a promising future for the use of GLZSW as substitute for fine aggregate in concrete used to shield against X-ray radiation.
4
Content available X-ray analysis of biomass wood briquette structure
EN
The study aims to measure the wood chips flow during the briquetting process by the X-ray image analysis. Scots pine (Pinus sylvestris L.) constituted the used feedstock that has been previously divided, according to the standard, into four (>1.0; 1.1-4.0; 4.1-8.0; 8.1-16.0 mm) groups of fraction. Examination of the X-ray image allows description of the movement of the wood fractions flow after the briquetting process. The correlations between the vertical axis and scattering plane factors were estimated. The correlation coefficient was 0.973 and was almost complete. The calculations were made for the areas of deviations (SD) and the area of scattering planes (DPS). Particular flow irregularities were determined for deviations ranges of individual groups of fractions and were (>1.0)=3.04; (1.1-4.0)=4.08; (4.1-8.0)=6.33 and (8.1-16.0)=7.33 cm2, and for scattering planes they were accordingly e (>1.0)=0.32; (1.1-4.0)=0.72; (4.1-8.0)=0.97 and (8.1-16.0)=1.29 cm2.
PL
Badania miały na celu określenie przepływu frakcji zrębków drzewnych w trakcie brykietowania wykorzystując analizę obrazu zarejestrowaną przy użyciu promieni rentgenowskich. Użytym materiałem była sosna zwyczajna, która uprzednio przygotowano w formie zrębków i sklasyfikowano według normy na czerech grupy frakcji (>1.0, 1.1-4.0, 4.1-8.0 i 8.1-16.0 mm). Analiza obrazu rentgenowskiego pozwoliła na charakterystykę ruchu frakcji surowca w trakcie procesu brykietowania. Zarejestrowany współczynnik korelacji pomiędzy osią pionową i płaszczyzną rozpraszania był prawie pełen i wynosił 0.973.Wykonane obliczenia zostały przeprowadzone dla obszarów rozproszenia przepływu biomasy, na których występowały nieregularności przepływu (SD) i płaszczyzn charakteryzujących powierzchnie rozpraszania (DPS). Określone nieregularności przepływu oszacowano dla poszczególnych grup frakcji na poziomie (>1.0)=3,04; (1.1-4.0)=4,08; (4.1-8.0)=6,33 i (8.1-16.0)=7,33 cm2, zaś dla płaszczyzn rozproszenia wynosiły kolejno (>1.0)=0,32; (1.1-4.0)=0,72; (4.1-8.0)=0,97 i (8.1-16.0)=1,29 cm2.
PL
Wstęp i cel: Badania nad poprawą jakości obrazów uzyskanych z pomiarów na tomografie komputerowym jest zadaniem kluczowym w dzisiejszych czasach. Naukowcy nadal pracują nad wyborem odpowiedniego protokołu skanowania, który umożliwi bezpiecznie i z należytą dokładnością zeskanować ciało pacjenta. Materiał i metody: W artykule scharakteryzowano podstawowe artefakty oraz czynniki wpływające na jakość obrazów tomograficznych. Zastosowano metodę analizy. Wyniki: Wzrost aktywności fotonów i ich oddziaływania z danym środowiskiem, zależy od grubości, gęstości i liczby atomowej obiektu przez który przechodzą. Zmiana wymiarów matrycy oraz obszaru obrazowania (FOV), bezpośrednio wpływa na rozdzielczość przestrzenną i kontrastową danych. Typ budowy tomografu bezpośrednio determinuje czas skanowania, a tym samym wpływa na rozdzielczość czasową. Wniosek: Mimo dużych zmian, komputerowe systemy tomograficzne, nadal bazują na podstawowych zjawiskach wynikających min. z oddziaływania promieniowania rentgenowskiego na dane struktury anatomiczne. Zrozumienie tych zależności leży u podstaw poznania idei pomiaru, a tym samym umiejętnego wyboru protokołu skanowania.
EN
Introduction and aim: Research on improving quality of images obtained from computer tomography measurements is a key tasks in this times. Scientists are still working on selection appropriate scanning protocol that enables secure and accurately scan the patient’s body. Material and methods: The article describes the basic artifacts and factors affecting on quality of topographic images. Analysis method has been used. Results: Activity of photons depends on the thickness, density and atomic number of the object. Changing matrix size and field of view (FOV) directly affects on spatial and contrast resolution. Type of construction-CT directly determines the average scan time and thus affects on temporal resolution. Conclusion: Computer tomography systems still rely on the basic phenomena arising from the influence of X-ray anatomical structure data. To develop and practice the most safe and effective scanning methods, radiologic technologists must first understand the physical principles that make up the foundation of CT.
6
Content available remote Radioterapia powierzchniowa i ortowoltowa
PL
Promieniowanie rentgenowskie w zakresie energii stosowanych w radioterapii powierzchniowej i ortowoltowej jest wytwarzane przez generatory rentgenowskie pracujące w zakresie napięć 50-500 kV (uzyskana energia 50-500 keV). W przypadku zastosowania terapeutycznego przyjmuje się, że dla najwyższych energii promieniowanie wnika na głębokość użyteczną około 4-6 cm. Dawkamaksymalna jest uzyskiwana na powierzchni skóry, dlatego napromienianie to jest użyteczne w leczeniu zmian skóry, tkanek powierzchniowych, żeber, kręgosłupa i kości czaszki. Radioterapia powierzchniowa i ortowoltowa jest doskonałą, nieinwazyjną alternatywą dla chirurgii raka skóry w przypadku zmian umiejscowionych na fałdach nosa, powiek i uszu.
7
Content available remote Historia rentgenodiagnostyki
PL
W połowie lat pięćdziesiątych XIX wieku Heinrich Geisler opracował sposób wtapiania elektrod metalowych w szkło. Angielski fizyk William Crookes zmodyfikował rurkę Geislera tak, aby można było badać właściwości promieni katodowych. Nazwano ją rurką Crookesa. Wilhelm Konrad Roentgen prowadząc intensywne badania nad promieniami katodowymi, 8 listopada 1895 roku odkrył zupełnie nowe promieniowanie, które przenikało przez ludzkie ciało. Po tym odkryciu nastąpił gwałtowny rozwój koncepcji konstrukcji lamp emitujących promieniowanie rentgenowskie. W 1913 roku, dzięki amerykańskiemu fizykowi, Williamowi Davidowi Coolidge’owi, powstała lampa rent­genowska, która na przestrzeni lat jest udoskonalana.
EN
In the mid-fifties of XIX century Heinrich Geisler developed a method of fusing metal electrodes in a glass. A seemingly insignificant experiment has led to a great discovery. Research carried out by the English physicist William Crookes gained a lot of publicity. He modified Geisler’s tube to explore the nature of the cathode rays. It was called Crookes tube. Wilhelm Konrad Roentgen – German physicist who conducted research on cathode rays, 8th November, 1895 discovered new radiation that penetrated through the human body X-ray irradiation. After this discovery, sudden development of X-rays lamps was noticed. In 1913, American physicist, William David Coolidge elaborated device dedicated to this radiation – X-ray tube, which has been improved over the years, until now.
PL
W artykule przedstawiono możliwości wykorzystania radiologicznej tomografii komputerowej w zakresie defektoskopii układów izolacyjnych. Na przykładzie izolatorów wykonanych z różnych materiałów dielektrycznych stałych pokazano typowe zastosowania tej techniki m. in. do oceny jednorodności i jakości struktury układu izolacyjnego oraz oceny i lokalizacji przyczyn jej uszkodzenia.
EN
The article presents the possibility of using radiological computed tomography in the field of insulation system defectoscopy. On the example of insulators made of different dielectric materials it was shown a typical application of this technique, among others to assess the uniformity and quality of the insulation system structure and evaluation and location of the cause of its damage.
PL
W pracy badano wpływ starzenia na właściwości polimerowego cementu kostnego. Proces starzenia cementu kostnego realizowano poprzez zastosowanie naświetlania promieniami rentgenowskimi oraz moczenia w roztworze Ringera. Przeprowadzono badania statycznego ściskania i zginania zgodnie z wymogami normy ISO 5833 oraz badania zmęczeniowe niskocyklowe. Na podstawie badań zmęczeniowych opracowano krzywe cyklicznego pełzania i charakterystykę dynamicznego modułu sprężystości. Po starzeniu cementu kostnego stwierdzono spadek wytrzymałości na zginanie odpowiednio po naświetlaniu promieniami rtg i moczeniu w roztworze Ringera o 23% i o 32% a modułu sprężystości na zginanie o 20% i o 21%. Wytrzymałość na ściskanie cementu kostnego po promieniowaniu rtg spadła o 4% a po moczeniu w roztworze Ringera wzrosła o 9%. Moduł sprężystości wzrósł o 7% po starzeniu w środowisku wodnym a po promieniowaniu rtg pozostał bez zmian. Zaobserwowano również wpływ starzenia na właściwości lepkosprężyste cementu kostnego po promieniowaniu rtg. Stwierdzono wzrost dynamicznego modułu sprężystości cementu kostnego oraz uzyskanie mniejszych odkształceń podczas pełzania.
EN
The paper describes the research into the influence of ageing on the properties of the polymer surgical cement. The process of ageing of the surgical cement was performed using X-ray radiation and soaking in Ringer’s solution. The studies of static compression and bending in compliance with ISO 5833 requirements and low-cycle fatigue tests were carried out. Based on the fatigue tests performed, the curves of cyclic creep were obtained and characteristics of dynamic elasticity modulus developed. After ageing of the surgical cement, a decrease of bending strength was identified after X-ray radiation and soaking in Ringer’s solution, by 23% and 32% respectively, while the modulus of bending elasticity by 20% and 21%. Compression strength of surgical cement after X-ray radiation decreased by 4%, and increased by 9% after soaking in Ringer’s solution. The modulus of compression elasticity increased by 7% after ageing in a wet environment, while after X-ray radiation it remained almost unchanged. Also, the influence of ageing on viscoelastic properties of surgical cement after X-ray radiation was observed. A decrease in the dynamic elasticity modulus of surgical cement was identified, while the deformations obtained during creep were smaller.
PL
Wdrażane u nas w kraju normy europejskie PN-EN np. z zakresu badań nieniszczących metodami radiologicznymi często są krytykowane przez specjalistów zarówno pod względem merytorycznym ale także i tematyczno-organizacyjnym. Jednakże ze względu na wymóg wiernego ich tłumaczenia na język polski, a także z powodu braku aktywnego udziału naszych specjalistów przy tworzeniu nowych norm (po wejściu Polski do Unii Europejskiej) normy te zostają formalnie wprowadzane w naszym kraju, nie zawsze spełniając właściwą sobie funkcję. Autor nin iejszego referatu chciałby wyraźnie podkreślić, iż stosowane w przeszłości polskie normy PN były pod tym względem wielokrotnie bardziej wartościowe niż obecne normy PN-EN. Na bazie tylko jednego terminu - promieniowanie X - ujętego w normie terminologicznej "PN-EN 1330-03 Badania nieniszczące. Terminologia. Terminy stosowane w radiograficznych badaniach przemysłowych" autor chciałby przedstawić problemy związane z definicjami niektórych pojęć w zakresie np. terminologii.
PL
W artykule przedstawiono rozwiązania zespołów funkcjonalnych komory próżniowej, umożliwiąjace realizację złożonych procesów badawczych i technologicznych, którym towarzyszy emisja promieniowania rentgenowskiego, oraz sposoby zapobiegania emisji szkodliwego promieniowania do otoczenia. Zaprezentowano szczególne warunki pracy tych zespołów oraz przykładowe konstrukcje opracowane, wykonane i wdrożone w Instytucie Technologii Eksploatacji - PIB.
EN
The paper presents design of functional units of the test chamber, protecting from X-ray radiation. The units make it possible to safely perform complex research and technological processes inside, which are a source of X-ray radiation. Particular attention has been put in the paper to operating conditions of these units and examples of designs elaborated, manufactured and implemented at ITeE-PIB.
PL
Wiązka promieni rentgenowskich przenikając przez materię ulega osłabieniu poprzez zjawisko pochłaniania lub rozpraszania. Zdolność ośrodka do osłabiania promieniowania rentgenowskiego charakteryzuje współczynnik absorpcji masowej µ*. Współczynnik ten jest wielkością addytywną i znając skład chemiczny danej substancji można go obliczyć teoretycznie. W przypadku próbek skalnych o bardzo skomplikowanym składzie chemicznym prościej jest jednak wyznaczyć go doświadczalnie. Współczynnik absorpcji masowej wykorzystywany jest w rentgenowskiej analizie ilościowej oraz do szacowania fotoelektrycznego współczynnika absorpcji Pe. Badania przeprowadzono dla 96 próbek mioceńskich (piaskowców i iłowców) z dwóch otworów Jasionka-4 i Chałupki Dębniańskie-3. Uzyskane wartości współczynnika absorpcji masowej zawierają się w przedziałach: 39-50 cm2/g dla piaskowców i 45-51 cm2/g dla iłowców. Wąski przedział wartości µ* dla iłowców wiąże się z małym zróżnicowaniem ich składu mineralnego. Piaskowce wykazują znacznie większe zróżnicowanie pod tym względem, szczególnie, jeżeli chodzi o stopień zailenia oraz zawartość kalcytu. Wydaje się również, że ten drugi czynnik ma największe znaczenie, o czym świadczy fakt, że najwyższe wartości µ* otrzymano dla piaskowców wapnistych.
EN
The mass absorption coefficient µ* is a characteristic feature of the given mineral and defines its ability to weaken the X-ray radiation. This coefficient can be calculated from the chemical composition, but it is easier to measure it directly. The paper describes the method of measurement and as the example the results obtained for the Miocene rocks from the two boreholes: Jasionka-4 and Chałupki Dębniańskie-3, from the Carpathian Foredeep are shown. The mass absorption coefficient is used in X-ray quantitative analysis and for calculating the photoelectric absorption coefficient Pe.
PL
Opisano wyniki eksperymentalne otrzymane w trakcie pomiarów emisji promieniowania rentgenowskiego oraz strumieni jonów w koaksjalnym akceleratorze IPD plazmy impulsowej. Wykazano istnienie zsynchronizowanych w czasie wiązek jonowych i emisji rentgenowskiej, świadczących o występowaniu zjawiska wielokrotnego zaciskania się sznura plazmy.
EN
Experimental results obtained for IPD coaxial accelerator of impulse plasma are presented. Existence of synchronized X-ray emissions and ion beams has been proved. These results are evidence of repeated pinching of plasma column.
15
Content available remote Tomografia rentgenowska
PL
Praca zawiera ogólną charakterystykę tomografii rentgenowskiej. W pracy przedstawiono podstawy fizyczne i matematyczne tomografii rentgenowskiej. Omówiono zagadnienie rekonstrukcji obrazu z projekcji. Zastosowanie tomografii rentgenowskiej zaprezentowano na przykładzie obrazowej diagnostyki medycznej. Omówiono budowę tomografu rentgenowskiego.
EN
This work presents a review of X-ray computer tomography. Physical and mathematical principles are presented. Image reconstruction from projection is discussed. Medical imaging diagnostics is presented as an example of X-ray tomography application. Construction of CT scanner is discussed.
16
Content available remote Analiza ilościowa składu pierwiastkowego na mikroanalizatorze rentgenowskim
PL
W referacie przedstawiono metody analizy ilościowej składu pierwiastkowego na mikroanalizatorze rentgenowskim. Omówiono zalety i wady stosowanych w Zakładzie Tribologii metod mikroanalizy. Przedstawiono wyniki badań przeprowadzonych na mikroanalizatorze Voyager 3050 firmy Noran Instruments z zastosowaniem procedur "wzorcowych" i "bezwzorcowych".
EN
The authors presents methods of X-ray quantitative analysis of elemental composition using energy dispersive spectrometer Voyager 3050 (Noran Instruments-USA). Two methods of quantitative analysis, i.e. standard and standardless were employed and the results are compared. Both virtues and drawbacks of the methods are pointed out.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.