Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  Krynica
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available Drogi kolejowe 2013
PL
23–25 października 2013 r. w ośrodku rehabilitacyjno-wypoczynkowym Panorama w Krynicy Zdroju odbyła się 17. edycja ogólnopolskiej Konferencji Naukowo-Technicznej Drogi kolejowe 2013.
EN
The lithostratigraphy and biostratigraphy of the Bystrica/Tylicz and Krynica facies zones of the Magura Nappe have been studied in the Beskid Sadecki Range and Lubovnianska Vrchovina (Polish and Slovak parts of the Western Outer Carpathians respectively). The new, Tylicz Zone is established, and the Szczawnica, Zarzecze, Magura and Kremna formations are redefined and described. These formations, spanning over 35 myrs, represent a synorogenic deep-water turbidites depositional system that dominated the southern part of the Magura Basin after the collision of the Alcapa Mega Unit with the Czorsztyn/Oravic ridge. The calcareous nannoplankton zones NP14-NP25 (Middle Eocene to Late Oligocene) and NN1-NN2 (Early Miocene) were recognized.
PL
W artykule przedstawiono budowę geologiczną i warunki hydrogeologiczne rejonu Krynicy oraz klasyfikację hydrochemiczną i chemizm wód podziemnych. Dotyczy to niezagospodarowanych do tej pory ujęć wód słabo zmineralizowanych, jak i mineralnych. Najczęściej są to źródła, które ze względu na swoją wydajność, położenie i wysoką jakość wody mogą być wykorzystane jako ujęcia wód pitnych. Źródła o większej wydajności i zlokalizowane w rejonie zabudowań mieszkalnych mogą służyć do zaopatrzenia ludności w wodę pitną, natomiast położone w rejonie szlaków turystycznych, po odpowiednim zagospodarowaniu, udostępnione dla turystów.
EN
The geologic and hydrogeologic conditions in the Krynica region are presented, and the groundwater chemistry and hydrochemistry classified. This refers to unmanaged intakes of weakly mineralized and mineralized water. Most frequently these are springs, which owing to their yield, location and high quality, can be used as drinking water intakes. High-yield springs, localized close to the human residences, can be used for supplying people with drinking water; springs in the neighbourhood of tourist routes can be used for tourist purposes, after prior adaptations.
PL
W artykule przedstawiono problem ustalenia parametrów eksploatacyjnych dla odwiertu Zuber III w Krynicy, w aspekcie uzyskania wydobycia wody i gazu w sposób ciągły. Przeanalizowano ciśnienia dynamiczne i prędkości przepływu w odwiercie. Przeprowadzono obliczenia komputerowe w celu ustalenia głębokości zapuszczania rur wydobywczych do odwiertu. Obliczenia przeprowadzone zostały dla danych uzyskanych z pomiarów wykonanych w omawianym odwiercie. Z obliczeń tych wynika, że zwiększone opory przepływu w przewodzie wydobywczym mogą być spowodowane zmniejszeniem przekroju na skutek wytrąconego osadu. W pracy, poza sugestią wymiany rur wydobywczych, zaleca się zwiększenie głębokości ich zapuszczenia oraz rozważenie zapuszczenia tych rur o mniejszej średnicy. Zastosowanie zwężki ograniczającej o średnicy 5 mm i zwiększenie głębokości zapuszczenia rur wydobywczych pozwoli na uzyskanie wydobycia w sposób ciągły oraz zwiększenie ilości wydobywanej wody.
EN
The paper gives the problem of setting exploitation parameters for the well Zuber III in Krynica in view of a continuous production of water and gas. Dynamic pressure and flow rates in the well were analysed. Computer calculations were made to establish the depth of tripping of production pipes into the well. Calculations were performed from the data obtained from measurements made in the given well. It follows from the calculations that the increased flow resistivities in the string can be caused by the reduced diameter (scale). It is recommended to replace the production pipes, increase the depth of tripping and possibly apply smaller diameter pipes. The use of a reducing pipe (5 mm in diameter) and increase of depth of tripping should enable one to provide continuous production and increase the volume of the extracted water.
7
Content available remote Wpływ wysypiska komunalnego w Krynicy na jakość wód
EN
The paper is a brief survey of investigation results of municipal refuse storage yard of Krynica town, carried out as part of required evaluation of the influence of investments on surface and underground water reservoirs. The tests were made at three stages: zero monitoring, and them after one and four years of storage yard exploitation. The degree of purity was determined basing on water samples taken from piezometers and surface water courses, with reference to required values given in MOŚZNiL Recommendations.
PL
Prawidłowo zorganizowana gospodarka odpadami powinna przewidywać okresową kontrolę stopnia oddziaływania składowiska na środowisko w trakcie jego eksploatacji jak i też przez pewien czas po rekultywacji (wg UE co najmniej 30 lat).
9
Content available remote Analiza techniczno-ekonomiczna sprężania i skraplania CO2 w Uzdrowisku Krynica
PL
W artykule przedstawiono problem zagospodarowania dwutlenku węgla wydobywanego z odwiertów Zuber w Krynicy. Przeprowadzone zostały obliczenia zużycia energii dla sprężania i skraplania CO2. Rozpatrzono wariantowe rozwiązanie polegające na sprężaniu części gazu do ciśnienia 0,7 MPa i pozostałej ilości CO2 przeznaczonej do skraplania do ciśnienia 8 MPa. W wyniku przeprowadzonej analizy zużycia energii przypadającej na jednostkę sprężanego gazu, przy uwzględnieniu instalacji do odsiarczania tego gazu, zaproponowano inną wersję rozwiązania, w której całość CO2 będzie skraplana, a gaz do rozlewni wód mineralnych oraz do suchych kąpieli doprowadzany będzie po regazacji.
EN
The problem of management of carbon dioxide exploited from the Zuber wells in Krynica is presented. Calculations of energy consumption during compression and liquefaction of CO2, were carried out. An alternative design is discussed based on the partial compression of a gas to the pressure of 0,7 MPa and the compression of the remaining part of CO2, (designed for liquefiction) to the pressure of 8 MPa. As a result of analysis of power consumption per volume unit of the compressed gas, the modification of the existing installation is proposed with consideration of the sulphur removal system. According to this proposition, the whole amount of CO2, will be liquefied. Part of the gas will be transported to the mineral water bottling plant and the rest to the spa installation (dry bath) for further use.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.